Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Whitestone Poncelet RISEC Project Final Technical Report

This report covers the development of the Poncelet Kinetics RHK100 Prototype. The work was completed by Hasz Consulting, LLC; CE2 Engineers, LLC; Energetic Drives, LLC; and Applied Power and Control all operating as subcontractors to Whitestone Power and Communications during the year from October 1, 2010 to September 23, 2011. As designed, the prototype is run-of-river instream energy conversion (RISEC) system. The design is principally a three-stage undershot water wheel arranged according to the method of General Poncelet. The power train consists of an epicyclic transmission coupled to a permanent magnet generator. The electronic controls system governs the speed of the wheel and rectifies the power signal to enable the system to be integrated with infinite grid infrastructures, to operate in parallel in finite grid applications with other small power productions sources or to operate in stand-alone mode on demand.

13 HYDRO ENERGY↗

An Integrated Framework for Risk Assessment of High Safety Significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants: Methodology and Demonstration

This report documents the activities performed by Idaho National Laboratory (INL) during Fiscal Year (FY) 2022 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) risk assessment project. In FY 2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a technical basis to support effective and secure DI&C technologies for digital upgrades/designs. A framework was proposed for this strategy, which aims to (1) provide a best-estimate, risk-informed capability to quantitatively and accurately estimate the risk impact of plant modernization, considering the introduction of high safety-significant safety-related (HSSSR) DI&C systems, (2) support and supplement existing risk-informed DI&C design guides by providing quantitative risk information and evidence, (3) offer a capability of design architecture evaluation of various DI&C systems, (4) assure the long-term safety and reliability of HSSSR DI&C systems, and (5) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals, the framework provides a means to address relevant technical issues by: (1) defining a risk-informed analysis process for DI&C upgrade, that integrates hazard analysis, reliability analysis, and consequence analysis, (2) applying risk-informed tools to address common cause failures (CCFs) and quantify corresponding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the component level, system level, and plant level, and (4) providing insights and suggestions on designs to manage the risks, thus to support the development and deployment of advanced DI&C technologies on nuclear power plant (NPPs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operation and control of hybrid HVDC system with LCC and full-bridge MMC connected in parallel

In this study, a new kind of hybrid high-voltage direct current (HVDC) system is proposed. Each terminal of the proposed system consists of one line commutated converter (LCC) and one full-bridge modular multilevel converter (FB-MMC). The LCC and FB-MMC are connected in parallel so that they can share the same transmission line. The active–reactive power capability of the hybrid HVDC system is extended compared with the conventional LCC-HVDC system, and power reversal control without power interruption can be achieved by the coordination control of LCC and FB-MMC. Besides, the proposed hybrid HVDC system is capable of handling DC fault, because both LCC and FB-MMC have DC fault blocking capability. Moreover, the power rating of FB-MMC can be designed to low value while keeping the bulk-power transmission capability of LCC. A two-terminal bipolar hybrid HVDC system is built in PSCAD/EMTDC. The simulation results verify the effectiveness and feasibility of the proposed hybrid topology and corresponding control strategies.

42 ENGINEERING↗

Electrified vehicle DC power conversion with distributed control

An electrified vehicle has a battery pack comprising series-connected battery units providing a main voltage. To supply a lower voltage bus equally from all battery units, a plurality of DC/DC converters are powered by respective units and have their outputs in parallel. A central module has an outer loop controller generating a target current to regulate the bus voltage to a predetermined voltage and has an allocator distributing the target current into a plurality of allocated current commands according to respective states of charge of the battery units. A plurality of local controllers each adjusts a current of a respective DC/DC converter. Each local controller receives a respective allocated current command as a respective feedforward control variable. Each local controller uses an error between the bus voltage and the predetermined voltage to be integrated as a respective feedback control variable only when the error is above a threshold.

33 ADVANCED PROPULSION SYSTEMS↗

Robust PID Control Against Nonlinear Uncertainties in Modern Power Systems with Microgrids

This paper investigates the problem of robust PID control for nonlinear power systems with uncertainties. In this paper, we analyze the challenges posed by nonlinearities and uncertainties in power systems, as well as the limitations of traditional linearization methods. On this basis, a PID control design method is proposed, which utilizes only the Lipschitz constant information of the nonlinear uncertainties to achieve global stability control for the power systems. The paper provides a rigorous mathematical foundation to demonstrate the effectiveness and robustness of the controller. Finally, simulation studies are conducted to validate and evaluate the performance of the proposed model, algorithm, and controller design.

Yuan, Shuo↗

Angle Droop Design for Grid-Forming Inverters Considering Impacts of Virtual Impedance Control

Grid-forming inverters (GFMs) based on active power-frequency droop control and reactive power-voltage droop control have been developed in recent years, which can generate voltage and frequency references for islanded power systems or microgrids to improve system-wide synchronization and power-sharing capability. It is known that the control delays in GFMs may cause system harmonic instability. To eliminate this issue, virtual impedance techniques are normally adopted. This paper gives a comprehensive examination of the impacts of virtual impedance control block Z v in GFMs on system stability. It is revealed that although Z v is effective in eliminating system harmonic stability, it may ruin system synchronization stability as a side effect. To compensate for the negative impacts caused by Z v , an active power-angle control block is added into the conventional droop control. Design criteria are also proposed accordingly to ensure system stability over the entire frequency range. Simulations and experimental testing are conducted to validate the analysis and the proposed design guidelines. It can be concluded that the Z v control-caused grid-synchronization instability issues can be eliminated with an appropriate active power-angle droop design.

Kong, Le↗

Impacts of Voltage-Based Grid Support Functions on Energy Production of PV Customers

This paper presents the impact of inverter grid- support functions (GSFs) on photovoltaic (PV) customer energy production on a real distribution feeder in Oahu, HI. These autonomous GSFs based on local voltage measurements are good alternatives to increase PV hosting capacity. However, these functions can result in PV energy curtailment to the customer, and this study addresses the concerns about the impact of inverter GSFs through detailed quasi-static time series (QSTS) simulations. It proposes four metrics: maximum and average GSF curtailment, average increased generation and average net generation change, to assess the impact of a given control on PV systems located on customer sites. It was found that curtailment of PV production is negligible for customers where peak voltage is within ANSI C84.1 range. A reliable relationship between curtailment and peak customer voltage is demonstrated, suggesting that peak voltage could be used as an indicator of customer curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Performance Computing - Power Application Programming Interface Specification Version 2.0.

Measuring and controlling the power and energy consumption of high performance computing systems by various components in the software stack is an active research area. Implementations in lower level software layers are beginning to emerge in some production systems, which is very welcome. To be most effective, a portable interface to measurement and control features would significantly facilitate participation by all levels of the software stack. We present a proposal for a standard power Application Programming Interface (API) that endeavors to cover the entire software space, from generic hardware interfaces to the input from the computer facility manager.

97 MATHEMATICS AND COMPUTING↗

DESIGN AND TESTING OF A DIGITAL REGULATOR FOR FERMILAB MAGNET POWER SYSTEMS

In this thesis, the design of a digitally controlled DC power system for testing conventional and superconducting magnets is proposed. The designed PID controller performances have been tested by the 30kA test stand for superconducting magnets, Vertical Magnet Test Facility (VMTF), which is hosted at the Fermilab Magnet Test Facility (MTF). The system is implemented on a National Instruments CompactRIO and both real-time and FPGA targets are programmed. A full 24-bit PID algorithm is coded and successfully tested by a manual tuning approach. An automated tuning algorithm is then introduced. As it will be shown by simulation and experimental results, the proposed system meets all design specifications. The current loop stability is up to 14 times better than the existing regulator and a control accuracy less than 4 ppm is achieved. Shorted-bus tests of the PID regulator have been successfully performed on the VMTF power system. In order to test the generalization capability of the designed system towards different types of magnets, the system has been easily adapted to and tested on the 10kA conventional magnet test stand (Stand C at Fermilab). As shown by experimental results, the designed PID controller features really high performancesin terms of steady-state accuracy and effectiveness of the tuning algorithm.

43 PARTICLE ACCELERATORS↗

Power Electronics for Electrolyzer Applications to Enable Grid Services

The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.

energy transitions↗

High Performance Computing - Power Application Programming Interface Specification Version 1.4

Measuring and controlling the power and energy consumption of high performance computing systems by various components in the software stack is an active research area [13, 3, 5, 10, 4, 21, 19, 16, 7, 17, 20, 18, 11, 1, 6, 14, 12]. Implementations in lower level software layers are beginning to emerge in some production systems, which is very welcome. To be most effective, a portable interface to measurement and control features would significantly facilitate participation by all levels of the software stack. We present a proposal for a standard power Application Programming Interface (API) that endeavors to cover the entire software space, from generic hardware interfaces to the input from the computer facility manager.

97 MATHEMATICS AND COMPUTING↗

Frequency Control Support of a Doubly-Fed Induction Generator Based on the Torque Limit

This paper proposes a torque limit-based inertial control scheme of a doubly-fed induction generator (DFIG) that supports the frequency control of a power system. If a frequency deviation occurs, the proposed scheme aims to release a large amount of kinetic energy (KE) stored in the rotating masses of a DFIG to raise the frequency nadir (FN). Upon detecting the event, the scheme instantly increases its output to the torque limit and then reduces the output with the rotor speed so that it converges to the stable operating range. To restore the rotor speed while causing a small second frequency dip (SFD), after the rotor speed converges the power reference is reduced by a small amount and maintained until it meets the reference for maximum power point tracking control. The test results demonstrate that the scheme can improve the FN and maximum rate of change of frequency while causing a small SFD in any wind conditions and in a power system that has a high penetration of wind power, and thus the scheme helps maintain the required level of system reliability. The scheme releases the KE from 2.9 times to 3.7 times the Hydro-Quebec requirement depending on the power reference.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vulnerability Detection Methodology for a Digital Signal Processor Micro-Controller at Edge Level Distributed Energy Resource Controller

Integration of renewable energy and energy storage based Distributed Energy Resource (DER) assets to the grid has seen an upsurge over the past few decades. Traditionally, energy would be generated at a thermal or nuclear power plant and then transmitted over long distance through the transmission grid and then supply to the customers at the distribution grid. Modern renewable energy based DER assets have brought energy production at the edge of distribution grid, which has made the grid vulnerable to cyber intrusion as the power flow controllers for such DER assets are now distributed across the grid from distribution level to transmission level. This paper discusses the vulnerability posed by such power flow controllers of DER assets and demonstrates a detection methodology for unauthorized access and manipulation of system configuration for Digital Signal Processor based Microcontrollers. Experimental results proving efficacy of the methodology have been shown in paper.

Bhowmik, Pankaj↗

CONSIDERATIONS FOR THE TREATMENT OF COMPUTERIZED PROCEDURES IN HUMAN RELIABILITY ANALYSIS

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES, PART TWO: APPLICABILITY OF CURRENT METHODS

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no U.S. nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

99 GENERAL AND MISCELLANEOUS↗

Current Human Reliability Analysis Methods Applied to Computerized Procedures

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room (Fink et al., 2009). Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of enhanced ease of use and easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

99 GENERAL AND MISCELLANEOUS↗

Note: A new regulation method of stable operation of high power cathode ion source

The hot cathode ion source will tend to be unstable when operated with high power and long pulse. In order to achieve stable operation, a new regulation method based on the arc power (discharge power) feedback control was designed and tested on the hot cathode ion source test bed with arc discharge and beam extraction. The results show that the new regulation method can achieve stable arc discharge and beam extraction. It verifies the success of feedback control of arc source with arc power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗