Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

BioMass PDU Electrical Design Study UPDATE

The BioMass Process Demonstration Unit (PDU) electrical system is used for the power distribution and control of the many motors and process required loads. Study requirements include a complete system analysis and equipment evaluation, which includes conductor sizing, transformer sizing, breaker and fuse sizing, short-circuit analysis, load-flow analysis, protective-device coordination, arc-flash-hazard analysis, and a multi-state code and grounding review.

09 BIOMASS FUELS↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of internal transport barriers in magnetically confined tokamak burning plasmas

The initiation, termination, and control of internal transport barriers associated with E × B flow shear near local minima of magnetic shear are examined for burning plasmas to determine if the positive feedback loops between profiles, instability, transport, and flow shear operate in regimes with fusion self-heating. A five-field transport model for the evolution of profiles of density, ion and electron temperature, ion and electron fluctuations, and radial electric field is utilized to examine the efficacy of controls associated with external inputs of heat and particles, including neutral beam injection, RF, pellets, and gas puffing. The response of the plasma to these inputs is studied in the presence of self-heating. The latter is affected by the external inputs and their modification of profiles and is, therefore, not an external control. Provided sufficient external power is applied, internal transport barriers can be created and controlled, both in ion and electron channels. Barrier control is sensitive to the locations of power deposition and pellet ablation, as well as temporal sequencing of external inputs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The pre-conceptual design of the nuclear island of ASTRID

The CEA is involved in a substantial effort on the ASTRID (Advanced Sodium Technological Reactor for Industrial Demonstration) pre-conceptual design in cooperation with EDF, as experienced Sodium-cooled Fast Reactor (SFR) operator, AREVA, as experienced SFR Nuclear Island engineering company and components designer, ALSTOM POWER as energy conversion system designer and COMEX NUCLEAIRE as mechanical systems designer. The CEA is looking for other partnerships, in France and abroad. The ASTRID preliminary design is based on a sodium-cooled pool reactor of 1500 MWth generating about 600 MWe, which is required to guarantee the representativeness of the reactor core and the main components with regard to future commercial reactors. ASTRID lifetime target is 60 years. Two Energy Conversion Systems are studied in parallel until the end of 2012: Rankine steam cycle or Brayton gas based energy conversion cycle. ASTRID design is guided by the following major objectives: improved safety, simplification of structures, improved In Service Inspection and Repair (ISIR), improved manufacturing conditions for cost reduction and increased quality, reduction of risks related to sodium fires and water/sodium reaction, and improved robustness against external hazards. The core is supported by a diagrid, which lay on a strong back to transfer the weight to the main vessel. AREVA is involved in a substantial effort in order to improve the core support structure in particular regarding the ISIR and the connection to primary pump. In the preliminary design, the primary system is formed by the main vessel and the upper closure comprising the reactor roof, two rotating plugs - used for fuel handling - and the components plugs located in the roof penetrations. The Above Core Structure deflects the sodium flow in the hot pool and provides support to core instrumentation and guidance of the control rod drive mechanisms. The number of the major components in the main vessel, primary pumps, Intermediate Heat Exchangers, and Decay Heat Exchangers are now under consideration. Under normal conditions, power release is achieved using the steam/water plant (in case of Rankine steam cycle) or the gas plant (in case of Brayton gas cycle). The diverse design and operating modes of Decay Heat Removal systems provide protection against common cause failures. A Decay Heat Removal system through the reactor vault is in particular studied with the objective to complement Direct Reactor Cooling systems. At this stage of the studies, the secondary system comprises four independent sodium loops (two and three sodium loops configurations are also investigated). Each loop includes one mechanical pump (or a large capacity Annular Linear Induction Electromagnetic Pump), and three modular Steam Generator Units characterized by once through straight tube units with a ferritic tube bundle; nevertheless, helical coil steam generator with tubes made of Alloy 800, and inverted type steam generator with a ferritic tube bundle are also investigated. The limited power of each modular Steam Generator Unit allows the whole secondary loop to withstand a large water/sodium reaction consecutive to the postulated simultaneous rupture of all the heat exchange tubes of one module. The arrangement of the components is based on the 'Regain' concept, in which the secondary pump is situated at a low level in the circuit; conventional arrangement, as SUPERPHENIX type, is a back-up option. Alternative arrangements based on gas cycles are also studied together with Na-gas heat exchanger design. This paper presents a status of the ASTRID pre-conceptual design. The most promising options are highlighted as well as less risky and back-up options. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stainless Steel 18-10 CO2 Laser Welding And Plasma Diagnostics

The welding of materials by CO2 laser took significant considerations in industry, for the reason of the quality of the carried out weldings, and for other many advantages, but the automation of the welding operation requires a control system in real time. The operation of welding is an operation of interaction between the radiation (laser), and the matter (welded part), which is characterized by the vaporization of the matter, formation of the keyhole in material, and appearance of plasma over the material. This study relates to the relation between the welding (molten material) and the plasma which is formed on material. The light emitted by plasma during laser welding was recorded by an OMA detector (Optical Multichannel Analyzer) over a wavelength width of 450 A ring . The analysis of this light allows to determine the composition of this plasma, its dimensions, and the state of its energy according to the laser parameters. The welded material is the stainless steel 18-10, it was found that the intensity of the light emitted by plasma depends on laser power, the welding speed, the flow rate of assist gas. The relation between the plasma and the state of the bead were analyzed for on-line monitoring welding.

36 MATERIALS SCIENCE↗

ADX: a high field, high power density, advanced divertor and RF tokamak

The MIT Plasma Science and Fusion Center and collaborators are proposing a high-performance Advanced Divertor and RF tokamak eXperiment (ADX) – a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to next step devices: fusion nuclear science facility (FNSF), fusion pilot plant (FPP), and/or demonstration power plant (DEMO). This high field (≥ 6.5 tesla, 1.5 MA), high power density facility (P/S ~ 1.5 MW/m2) will test innovative divertor ideas, including an ‘X-point target divertor’ concept, at the required performance parameters – reactor-level boundary plasma pressures, magnetic field strengths and parallel heat flux densities entering into the divertor region – while simultaneously producing high performance core plasma conditions that are prototypical of a reactor: equilibrated electrons and ions, regimes with low or no torque, and no fueling from external heating and current drive systems. Equally important, the experimental platform will test innovative concepts for lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators with the unprecedented ability to deploy launch structures both on the lowmagnetic- field side and the high-magnetic-field side – the latter being a location where energetic plasma-material interactions can be controlled and favorable RF wave physics leads to efficient current drive, current profile control, heating and flow drive. This triple combination – advanced divertors, advanced RF actuators, reactor-prototypical core plasma conditions – will enable ADX to explore enhanced core confinement physics, such as made possible by reversed central shear, using only the types of external drive systems that are considered viable for a fusion power plant. Such an integrated demonstration of high-performance core-divertor operation with steady state sustainment would pave the way toward an attractive pilot plant, as envisioned in the ARC concept (Affordable, Robust, Compact) [B. N. Sorbom, et al., submitted to Fusion Engineering Design, 2014] that makes use of high-temperature superconductor technology – a high-field (9.25 tesla) tokamak the size of the Joint European Torus that produces 270 MW of net electricity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Simulation of a Sub-Critical Coal Fired Power Plant

In order to address the demanding operating conditions for remaining coal-fired power plants, a dynamic model and a suite of tools have been developed for studying load cycling and to find optimization opportunities. A sub-critical steam cycle power plant was modeled in a flow-sheet modeling tool, APROS™. The model represented the firing system, economizer, evaporator, superheat, and reheat systems. Four loads from 100% TMCR to 25% TMCR were calibrated and tested such that low-to-high cycling could be studied. The model was run through various load cycles; one of which is presented here. This modeling is a prototype for general use in developing cutting edge controls products and for maximizing economic, low-emissions, and efficient operation of the existing coal power fleet.

Braun, Timothy↗

Modelling and assessing the near-wake representation and turbulence behaviour of control-oriented wake models

Due to the interaction between the wake of an upstream turbine on a downstream turbine, power losses and increased fatigue loads occur. By yawing the upstream turbine with regard to the wind direction, one can potentially reduce the power losses of the downstream turbine and reduce the fatigue loads. The evolution of the wake depends on the pressure gradient within the near-wake region and the turbulent kinetic energy and must be incorporated in existing wake steering algorithms to provide an accurate estimation of the wake flow. This paper will show a first approach to implement a near-wake model and a turbulence model in the curled wake model within the controls-oriented framework FLORIS. The near-wake model is based on an analytical expression of the velocity profile to model the pressure gradient. Furthermore, two turbulence models are incorporated within the curled wake model based on a Gaussian-distribution and a mixing length formulation. The adapted curled wake model is then assessed with the measurement data acquired in the wind tunnel at ForWind – University of Oldenburg. The evaluation of the models show good agreement for the velocity deficit and representation of the near-wake region. Furthermore, the turbulent kinetic energy behaved as expected in comparison to other work, showing a ring of high turbulent kinetic energy at non-yawed condition which is deflected to a curled shape at large yaw angles with the turbulence model based on a mixing length formulation.

FLORIS↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Scale‐Dependent Influence of Permafrost on Riverbank Erosion Rates

Abstract Whether permafrost systematically alters the rate of riverbank erosion is a fundamental geomorphic question with significant importance to infrastructure, water quality, and biogeochemistry of high‐latitude watersheds. For over four decades, this question has remained unanswered due to a lack of data. Using remotely sensed imagery, we addressed this knowledge gap by quantifying riverbank erosion rates across the Arctic and subarctic. To compare these rates to non‐permafrost rivers, we assembled a global data set of published riverbank erosion rates. We found that erosion rates in rivers influenced by permafrost are on average nine times lower than non‐permafrost systems; erosion rate differences increase up to 40 times for the largest rivers. To test alternative hypotheses for the observed erosion rate difference, we examined differences in total water yield and erosional efficiency between these rivers and non‐permafrost rivers. Neither of these factors nor differences in river sediment loads provided compelling alternative explanations, leading us to conclude that permafrost limits riverbank erosion rates. This conclusion was supported by field investigations of rates and patterns of erosion along three rivers flowing through discontinuous permafrost in Alaska. Our results show that permafrost limits maximum bank erosion rates on rivers with stream powers greater than 900 Wm −1 . On smaller rivers, however, hydrology rather than thaw rate may be the dominant control on bank erosion. Our findings suggest that Arctic warming and hydrological changes should increase bank erosion rates on large rivers but may reduce rates on rivers with drainage areas less than a few thousand km 2 .

54 ENVIRONMENTAL SCIENCES↗

Gradient-Based Multi-Area Distribution System State Estimation

The increasing distributed and renewable energy resources and controllable devices in distribution systems make fast distribution system state estimation (DSSE) crucial in system monitoring and control. We consider a large multi-phase distribution system and formulate DSSE as a weighted least squares (WLS) problem. We divide the large distribution system into smaller areas of subtree structure, and by jointly exploring the linearized power flow model and the network topology, we propose a gradient-based multi-area algorithm to exactly and efficiently solve the WLS problem. The proposed algorithm enables distributed and parallel computation of the state estimation problem without compromising any performance. Numerical results on a 4,521-node test feeder show that the designed algorithm features fast convergence and accurate estimation results. Comparison with traditional Gauss-Newton method shows that the proposed method has much better performance in distribution systems with a limited amount of reliable measurement. The real-time implementation of the algorithm tracks time-varying system states with high accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Control Design for a Marine Hydrokinetic Cycloturbine Vehicle

Abstract Marine Hydrokinetic (MHK) cycloturbines generate sustainable power by exploiting tidal currents. By powering the turbines and using pitching foils for control, a vehicle comprised of MHK cycloturbines also has the ability to station keep and maneuver. The vehicle consists of four counter-rotating cycloturbines, with hydrofoils oriented perpendicular to the flow in a paddlewheel configuration. Lift and drag generated from these foils sum together to produce thrust. An experimentally tuned simulation model that solves the six-degrees-of-freedom rigid body equations of motion for the MHK vehicle subject to hydrodynamic, hydrostatic, and propulsive forces is used to aid the design of vehicle controllers. Global feedback controllers are initially designed by applying classical control methods to an approximate linear model of the system dynamics. A higher performing nonlinear controller is designed using the nonlinear dynamic inversion (NDI) method. NDI accounts for the nonlinearities of the MHK system and therefore is suitable for a wide range of operating conditions. The response of the classical and NDI controllers to speed, depth, roll, pitch, and yaw commands are evaluated and compared in simulation. The classical controller outperforms the NDI controller for small amplitude maneuvers, although the degradation with NDI is minor. However, in the nonlinear operating regime the NDI controller outperforms the classical controller and the classical controller exhibits instability.

Automation & Control Systems↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Scaling up of Membrane Modules Leveraging Dimensional Analysis

In the current analysis, we study the separation performance using membrane modules through dimensional analysis (DA). We formulate the main process equations to identify relevant dimensionless numbers inherent in the physics. In particular, we identify that the critical step in the separation process is mass transfer through the selective layer. Remarkably, the dimensionless feed flow (DFfeed) emerges as a crucial factor in describing this process. Not only does DFfeed directly appear in the governing equations, but it also holds a physical significance associated with the time scales for the mass transfer across the feed side and through the selective layer. Regarding the output performance variables, we consider the recovery, stage cut, productivity and purity. In this context, we profit from experimental data and CFD simulations to evaluate the separation performance of the modules when varying the input flowrate, the scale of the module, and the CO2 permeance. These datasets enable us to establish correlations between performance metrics and the dimensionless feed flow. Using simple power functions of DFfeed, we obtain R2 coefficients exceeding 0.99, indicating the accuracy of the correlations built in the present work. In the future, we wish to use DA to understand key transport mechanisms, predict and control module performance, and challenge the universality of these findings by testing various gas separations across different membrane modules beyond our case study.

Pedrozo, Hector A.↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); soft open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CYCLE MODELING AND OPTIMIZATION OF AN INTEGRALLY GEARED sCO2 COMPANDER

This paper presents the selection of a system configuration and off-design control method for an integrally geared compander based on cycle modeling and optimization. The goal of the cycle modeling was to determine a cycle configuration that would reach an efficiency of 50% at design conditions and to optimize off-design control to maintain high efficiencies. The compander is being developed for use in a concentrated solar power supercritical carbon dioxide power plant with expected turbine inlet temperatures of 705°C and utilizing dry cooling leading to compressor inlet temperature varying between 35°C and 55°C. The compander is unique as it consists of eight turbomachinery stages on four pinions all being driven by a single bull gear. The separate stages offer the opportunity to consider a variety of flow splits and cycle configurations including intercooling and multiple stages of reheat. Cycle modeling was conducted in two stages: on-design and off-design. On-design modeling was simulated with all components operating at their design point. This was used to compare the performance of different cycle configurations and design temperatures. Off-design modeling was then performed to investigate the temperature dependence of the cycle efficiency and power output and to develop a control strategy. Strategies considered and discussed include: turbine bypass, compressor recycle, inlet guide vanes, and inventory control. To determine the best operating conditions for each configuration and control strategy, a genetic algorithm was implemented to optimize the cycle performance across the range of operating temperatures being considered. The final selection of cycle configuration, design temperature and control strategy is also presented.

bennett, jeffrey↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗