Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Hollow cathode heater development for the Space Station plasma contactor

A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.

Soulas, George C.↗

TROPIX Power System Architecture

This document contains results obtained in the process of performing a power system definition study of the TROPIX power management and distribution system (PMAD). Requirements derived from the PMADs interaction with other spacecraft systems are discussed first. Since the design is dependent on the performance of the photovoltaics, there is a comprehensive discussion of the appropriate models for cells and arrays. A trade study of the array operating voltage and its effect on array bus mass is also presented. A system architecture is developed which makes use of a combination of high efficiency switching power convertors and analog regulators. Mass and volume estimates are presented for all subsystems.

Manner, David B.↗

Evaluation of solar thermal power plants using economic and performance simulations

An energy cost analysis is presented for central receiver power plants with thermal storage and point focusing power plants with electrical storage. The present approach is based on optimizing the size of the plant to give the minimum energy cost (in mills/kWe hr) of an annual plant energy production. The optimization is done by considering the trade-off between the collector field size and the storage capacity for a given engine size. The energy cost is determined by the plant cost and performance. The performance is estimated by simulating the behavior of the plant under typical weather conditions. Plant capital and operational costs are estimated based on the size and performance of different components. This methodology is translated into computer programs for automatic and consistent evaluation.

El-Gabawali, N.↗

Resilience Design Patterns - A Structured Approach to Resilience at Extreme Scale (version 1.1)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest the prevalence of very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Therefore the resilience challenge for extreme-scale HPC systems requires management of various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. Also, due to practical limits on power consumption in HPC systems future systems are likely to embrace innovative architectures, increasing the levels of hardware and software complexities. As a result the techniques that seek to improve resilience must navigate the complex trade-off space between resilience and the overheads to power consumption and performance. While the HPC community has developed various resilience solutions, application-level techniques as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods and metrics to investigate and evaluate resilience holistically in HPC systems that consider impact scope, handling coverage, and performance & power efficiency across the system stack. Additionally, few of the current approaches are portable to newer architectures and software environments that will be deployed on future systems. In this document, we develop a structured approach to the management of HPC resilience using the concept of resilience-based design patterns. A design pattern is a general repeatable solution to a commonly occurring problem. We identify the commonly occurring problems and solutions used to deal with faults, errors and failures in HPC systems. Each established solution is described in the form of a pattern that addresses concrete problems in the design of resilient systems. The complete catalog of resilience design patterns provides designers with reusable design elements. We also define a framework that enhances a designer's understanding of the important constraints and opportunities for the design patterns to be implemented and deployed at various layers of the system stack. This design framework may be used to establish mechanisms and interfaces to coordinate flexible fault management across hardware and software components. The framework also supports optimization of the cost-benefit trade-offs among performance, resilience, and power consumption. The overall goal of this work is to enable a systematic methodology for the design and evaluation of resilience technologies in extreme-scale HPC systems that keep scientific applications running to a correct solution in a timely and cost-efficient manner in spite of frequent faults, errors, and failures of various types.

97 MATHEMATICS AND COMPUTING↗

Low-Power CO2 Compression Technology

Presently, the most feasible processes for extracting oxygen from the Martian atmosphere either require or are much more efficient if the atmospheric CO2 feed is provided at pressures well above the Martian ambient. Electrical power for performing the desired compression is likely to be an extremely limited resource on the Mars surface. Even if "cheap" nuclear power is available at a central site/launch facility where rocket propellent and oxidant are manufactured, life support applications needing oxygen production capabilities, such as rovers, portable life support, and remote or independent exploration stations, will benefit from extremely low-power atmospheric compression technology, such as the one discussed here. Our experiments show the potential of one very low-power approach to performing CO2 compression that uses the Mars diurnal temperature cycle to drive a heat engine. The 1 kg compressor has been tested over an extended period in a Mars environmental simulation chamber that mimics the composition, pressure, and temperature cycles that can occur on the Martian surface. The simple design, which has very few moving parts and can easily be scaled to larger or smaller sizes, produces a CO2 stream at a rate of 100 g/ day at a quality and pressure suitable for a variety of oxygen production processes.

Finn, John E.↗

Radial scale effect on the performance of low-power cylindrical Hall plasma thrusters

Investigation of the radial scale effect on low-power cylindrical Hall thrusters has been undertaken by comparing the thrusters with three different channel diameters of 28, 40, and 50 mm. The investigation found that both the anode efficiency and the thrust of the larger thruster are higher as the anode power is raised. On the other hand, higher current and propellant utilizations are achieved for the smaller thruster, which is due to higher neutral density and better electron confinement. The large plume angle of the small cylindrical Hall thruster causes thrust loss, resulting in the reduction of anode efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review and Future Perspective of Central Receiver Design and Performance

Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.

14 SOLAR ENERGY↗

Resilience Design Patterns: A Structured Approach to Resilience at Extreme Scale (V.2.0)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest the prevalence of very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Therefore, the resilience challenge for extreme-scale HPC systems requires coordination between various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. Also, due to practical limits on power consumption in future HPC systems, they are likely to embrace innovative architectures, increasing the levels of hardware and software complexities. Therefore, the techniques that seek to improve resilience must navigate the complex trade-off space between resilience and the overheads to power consumption and performance. While the HPC community has developed various resilience solutions, application-level techniques as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods to integrate the various HPC resilience techniques into composite solutions, nor are there methods to holistically evaluate the adequacy and efficacy of such solutions in terms of their protection coverage, and their performance & power efficiency characteristics. Additionally, few implementations of current resilience solutions are portable to newer architectures and software environments that will be deployed on future systems. We developed a new structured approach to the management of HPC resilience using the concept of resilience-based design patterns. In general, a design pattern is a repeatable solution to a commonly occurring problem. We identified the well-known solutions that are commonly used to deal with faults, errors and failures in HPC systems. In the initial design patterns specification (version 1.0), we described the various solutions, which address specific problems in the design of resilient HPC environments, in the form of patterns. Each pattern describes a problem caused by a fault, error or failure event in an HPC environment, and then describes the core of the solution of the problem in such a way that this solution may be adapted to different systems and implemented at different layers of the system stack. The catalog of these resilience design patterns provides designers with a collection of design elements. To construct complete resilience solutions using combinations of various patterns, we defined a framework that enhances HPC designers' understanding of the important constraints and the opportunities for the design patterns to be implemented and deployed at various layers of the system stack. The design framework is also useful for establishing interfaces and mechanisms to coordinate flexible fault management across hardware and software components, as well as to consider the trade-off between performance, resilience, and power consumption when constructing a solution. The resilience design patterns specification version 1.1 included more detailed explanations of the pattern solutions, the context in which the patterns are applicable, and the implications for hardware or software design. It also provided several additional examples and detailed case studies to demonstrate the use of patterns to build realistic solutions. In version 1.2 of the specification document, we have improved the pattern descriptions, including graphical representations of the pattern components. These improvements are largely based on critical comments, feedback and suggestions received from pattern experts and readers of the previous versions of the specification. The pattern classification has been modified to further clarify the relationships between pattern categories. This version of the specification also introduces a pattern language for resilience design patterns. The pattern language presents the patterns in the catalog as a network, revealing the relations among the resilience patterns. The language provides designers with the means to explore alternative techniques for handling a specific fault model that may have different efficiency and complexity characteristics. Using the pattern language also enables the design and implementation of comprehensive resilience solutions as a set of interconnected resilience patterns that can be instantiated across layers of the system stack. The overall goal of this work is to provide hardware and software designers, as well as the users and operators of HPC systems, a systematic methodology for the design and evaluation of resilience technologies in HPC systems that keep scientific applications running to a correct solution in a timely and cost-efficient manner despite frequent faults, errors, and failures of various types. Version 2.0 expands the resilience design pattern classification and catalog to include self-stabilization patterns and reliability, availability and performance models for each structural pattern.

97 MATHEMATICS AND COMPUTING↗

The Effects of Arcing Ejecta on Space Suit Materials from ISS RPCM Hot Mate/Demate During EVA

Onboard ISS, taking systems off-line when powering down to perform servicing on Remote Power Control Modules (RPCMs) introduces operational risk. An investigation lead by the NASA Engineering and Safety Center (NESC) was performed by a multi-center team to assess the safety of performing on-orbit replacement of RPCMs without powering down. This investigation revealed the potential for molten metal particulate generation in the event of an arcing occurrence. As RPCM replacement can be performed outside ISS during an Extra Vehicular Activity (EVA), it is necessary to assess the effects of this molten metal ejecta contact with the Extravehicular Mobility Unit (EMU) Space Suit Assembly (SSA) during an arcing event. A test was devised to mimic arcing ejecta contact with samples representing various SSA cross-sections. Four areas of the SSA were chosen for test to represent the majority of the SSA cross-sections. Testing was conducted by the University of California, Riverside that generated the molten metal particles, included varying composition, size and temperature, and dropped them onto the surface of the various SSA cross-sections. Exposed SSA materials were then evaluated for degree of damage, penetration, and thermal conductance through the cross-section by ILC Dover. Results showed that the SSA Glove is most susceptible to damage from arcing events. This data will be used to make risk management decisions for future RPCM servicing operations. This testing also demonstrated the durability of the SSA design and materials to exposure to extreme environments

Linda S Hewes↗

The Effects of Arcing Ejecta on Space Suit Materials from ISS RPCM Hot Mate/Demate During EVA

Onboard ISS, taking systems off-line when powering down to perform servicing on Remote Power Control Modules (RPCMs) introduces operational risk. An investigation lead by the NASA Engineering and Safety Center (NESC) was performed by a multi-center team to assess the safety of performing on-orbit replacement of RPCMs without powering down. This investigation revealed the potential for molten metal particulate generation in the event of an arcing occurrence. As RPCM replacement can be performed outside ISS during an Extra Vehicular Activity (EVA), it is necessary to assess the effects of this molten metal ejecta contact with the Extravehicular Mobility Unit (EMU) Space Suit Assembly (SSA) during an arcing event. A test was devised to mimic arcing ejecta contact with samples representing various SSA cross-sections. Four areas of the SSA were chosen for test to represent the majority of the SSA cross-sections. Testing was conducted by the University of California, Riverside that generated the molten metal particles, included varying composition, size and temperature, and dropped them onto the surface of the various SSA cross-sections. Exposed SSA materials were then evaluated for degree of damage, penetration, and thermal conductance through the cross-section by ILC Dover. Results showed that the SSA Glove is most susceptible to damage from arcing events. This data will be used to make risk management decisions for future RPCM servicing operations. This testing also demonstrated the durability of the SSA design and materials to exposure to extreme environments.

Linda S. Hewes↗

Surface Temperature Effect on Convective Heat Transfer Coefficients for Jet Impingement Cooling of Electric Machines with Automatic Transmission Fluid: Preprint

In this study, the results of NREL's continued work on experimental characterization of the thermal performance of free-surface jets of automatic transmission fluid impinged on a heated target surface are presented. The measured heat transfer coefficients are useful for understanding factors influencing performance of driveline fluid-based cooling systems for electric machines and help designers in developing high-performance, power-dense and reliable machines. Experiments were carried out for different fluid and target surface temperatures (50 degrees C, 70 degrees C, and 90 degrees C for the fluid and 90 degrees C, 100 degrees C, 110 degrees C, and 120 degrees C for the target surface). Impinging jet velocities (0.5 m/s to 7.5 m/s) and the jet position on the target surface (center versus edge) were also varied. The impinging angle was kept at 90 degrees relative to the target surface. It was found that higher target surface temperature increased heat transfer coefficients, namely, increasing surface temperature from 90 degrees C to 120 degrees C enhanced heat transfer coefficient values at higher impinged jet velocities (7.5 m/s) by up to 15%.

33 ADVANCED PROPULSION SYSTEMS↗

A Study of Large Scale Power Extraction and Insertion on Turbofan Performance and Stability

This describes the effects of turbofan power extraction and insertion (augmentation) on engine performance and stability. The purpose of this paper is to present how power augmentation affects a dual spool gas turbine engine cycle where the engine will also be required to provide thrust. The goals for the paper are to describe effective limits of power augmentation and offer strategies, utilizing spool choice and variable geometries, to maximize augmentation effect. While Analysis is general, two potential uses are explored: Power extraction for electrified aircraft propulsion and power insertion for thrust assist. Results of the paper show it is possible to extract over 20% (at 85% max thrust) and gain roughly 12% of maximum thrust through power insertion.

Gas Turbine engines↗

Performance characteristics and output power stability of a multichannel fibre laser

The effect of the density and number of spectral channels on the output power stability in a multichannel cw laser has been studied theoretically and experimentally. In our calculations, we used a model in which the interaction between channels due to gain medium saturation was determined by channel frequency spacing-dependent cross-saturation coefficients. The key features of lasing have been analysed and illustrated by the examples of three-, five- and nine-channel lasers. It has been shown that, at a given excess of the pump power over threshold, the channel powers can be equalised by introducing additional losses into the highest power channels. At a sufficiently high channel density, raising the pump power then leads to termination of lasing in the even channels. As the number of channels increases, the laser system retains its stability, but the time needed for the transition to a steady state increases sharply. In our experiments, we used an erbium-doped fibre laser whose design ensured independent control over the powers of up to 40 spectral channels anchored on the telecommunication frequency grid. Our experimental data are in qualitative agreement with the calculation results. In particular, a long-term relative instability less than 3 dB was only observed at a number of channels less than seven and channel frequency spacings above 400 GHz. Instability was shown to increase with an increase in the number and density of channels. (control of laser radiation parameters)

42 ENGINEERING↗

Test Results of Selected Commercial DC/DC Converters under Cryogenic Temperatures - A Digest

DC/DC converters are widely used in space power systems in the areas of power management and distribution, signal conditioning, and motor control. Design of DC/DC converters to survive cryogenic temperatures will improve the power system performance, simplify design, and reduce development and launch costs. In this work, the performance of nine COTS modular, low-tomedium power DC/DC converters was investigated under cryogenic temperatures. The converters were evaluated in terms of their output regulation, efficiency, and input and output currents. At a given temperature, these properties were obtained at various input voltages and at different load levels. A summary on the performance of the tested converters was given. More comprehensive testing and in-depth analysis of performance under long-term exposure to extreme temperatures are deemed necessary to establish the suitability of these and other devices for use in the harsh environment of space exploration missions.

Patterson, Richard↗

SPSP Phase III Recruiting, Selecting, and Developing Secure Power Systems Professionals: Individual and Team Performance Guidelines

The pending retirement of significant numbers of power system experts and a continuing trend of increasing complexity in modern power systems prompted the U.S. Department of Energy (DOE) to establish the three-phase Secure Power Systems Professional (SPSP) project. The project developed resources for job definition and competency analysis along with tools to guide assessment and curriculum design and to help identify and develop required knowledge, skills, and abilities in technical and operational aspects of power systems cybersecurity. The Secure Power Systems Professional Phase III final report was released last year which an appendix of Individual and Team Performance Guidelines. This new report is that appendix broken out as a standalone document to assist utilities in recruiting and developing Secure Power Systems Professionals at their site. Individual/Team Performance Guidelines were developed for each of the four job roles: the secure power systems engineer, incident responder, intrusion analyst, and security operator. They enable an “at-a-glance” view of the multidisciplinary and collaborative nature of SPSP job roles, for which skill sets were studied and then mapped to stories of critical incidents or vignettes. This afforded an enumeration of tasks required of each job role to effectively perform responsibilities and to meet bestpractice goals for that operation. Assignment of these tasks among the job roles, either as an individual responsibility or a collaborative responsibility, was validated during a job performance model analysis. The analysis identified 13 master vignettes from the collection of critical incident stories, many of which shared a common set of job responsibilities and tasks that were grouped into four vignette categories according to the task requirement for effective response to each event.

24 POWER TRANSMISSION AND DISTRIBUTION↗