Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Time-resolved quantitative multiphase interferometric imaging of a highly focused ultrasound pulse

Interferometric imaging is a well-established method to image phase objects by mixing the image wavefront with a reference one on a CCD camera. It has also been applied to fast transient phenomena, mostly through the analysis of single interferograms. It is shown that, for repetitive phenomena, multiphase acquisition brings significant advantages. A 1MHz focused sound field emitted by a hemispherical piezotransducer in water is imaged as an example. Quantitative image analysis provides high resolution sound field profiles. Pressure at focus determined by this method agrees with measurements from a fiber-optic probe hydrophone. This confirms that multiphase interferometric imaging can indeed provide quantitative measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluorescence lifetime measurements using photon pair correlations generated via spontaneous parametric down conversion (SPDC)

We have used photon pair correlations generated via spontaneous parametric downconversion (SPDC) to measure the fluorescence lifetime of the organic dye rhodamine 6 G, demonstrating that fluorescence lifetime measurements can be achieved using a continuous wave (CW) laser, without pulsed or modulated lasers. Our entangled photon method, quantum fluorescence lifetime (Q-FL) measurements, uses one photon to excite fluorescence and the resulting fluorescence photon is timed and referenced to the arrival time of the other entangled photon. Thus, we can exploit the short timescale of photon pair correlations to conduct experiments that are typically carried out with pulsed lasers and we show that the inherent timing of the photons is fast enough to resolve the nanosecond scale fluorescence lifetime of the sample. This measurement paves the way towards using the time correlations of entangled photons for fluorescence imaging; capitalizing on the presence of fast, sub-100 ps correlations that have not been demonstrated classically.

Eshun, Audrey (ORCID:0000000167697082)↗

Single-shot measurement of the nonlinear refractive index of air at 92 µm with a picosecond terawatt CO 2 laser

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a welldefined, high-quality beam from a comparatively nonuniform quasi-flat-top beam which is typical for highpeak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, yielding n 2 = 3.0 × 10 -23 m 2 /W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

43 PARTICLE ACCELERATORS↗

Internal Magnetic Field, Temperature and Density Measurements on Magnetized HED plasmas using Pulsed Polarimetry

The goals were to collaborate with the MSX project and make the MSX platform reliable with a performance where pulsed polarimetry would be capable of adding a useful measurement and then to achieve a first measurement using pulsed polarimetry. The MSX platform (outside of laser blow off plasmas adjacent to magnetic fields which are low beta) is the only device that can generate high-beta magnetized collisionless supercritical shocks, and with a large spatial size of ~10 cm. Creating shocks at high Mach numbers and investigating the dynamics of the shocks was the main goal of the project. The MSX shocks scale to astrophysical magnetized shocks and potentially throw light on the generation of highly energetic particles via a mechanism like the Fermi process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C. Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers. Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C. Mixtures of Fe 2 O 3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm. Copper oxides did not yield suitable signals at elevated temperatures. The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Comparative Study for Pressure Gain Combustion-Gas Turbine System Performance in NGCC Configurations

The Department of Energy (DOE) has a goal to increase natural gas combined cycle (NGCC) plant efficiency to greater than 70 percent on a lower heating value (LHV) basis. Improvement in gas turbine (GT) efficiency is key achieving this goal. While many of the traditional improvement methods (higher firing temperature, advanced materials, improved cooling methods, etc.) may increase current GT and NGCC efficiencies incrementally, combining these traditional advancements with breakthrough technologies such as pressure gain combustion (PGC) may provide significant system efficiency gains. PGC is a combustion process that results in a net pressure increase across the combustor (up to pressure ratio of 2.2) rather than the traditional (<5%) pressure drop. There are multiple PGC technologies being developed that create the pressure rise phenomena, including resonant pulse combustors (RPCs), pulse detonation engines (PDEs), wave rotor combustor (WRC) engines and rotating detonation engines (RDEs). In this study, scoping analyses of PGC concepts applied to NGCC power plants were performed by combining simplified analytical models for the RPC, PDE, WRC, and RDE types of pressure gain processes with a GT model to evaluate impacts of using each of the PGC technologies on key GT performance parameters. Sensitivity analyses were also performed. Ultimately, the PGC technologies were found to have the potential to increase simple cycle efficiency by 4–6 percent (absolute) and NGCC efficiency by 2–3 percent (absolute) based on the results of the current study.

03 NATURAL GAS↗

Uncertainty Quantification of Monolithic Tungsten Target Block Fatigue

The current STS spallation target design consists of 21 water cooled, tantalum clad, monolithic tungsten blocks. The target wheel assembly rotates such that each target block receives a direct proton pulse every 1.4 seconds (21 blocks / 15 Hz pulses). The quasi-steady heating induced by the repetitive beam pulses creates a significant mean stress distribution in the target. On top of this, the rapid energy deposition from a proton pulse induces dynamic stress waves that are of the same order of magnitude as the mean stresses. Over the design goal of 5,000 operational hours per year for a decade, each target must withstand over 130 million repetitions of these dynamic stress events. The fatigue life prediction of the target blocks is a complex sequence of simulations that depend upon a set of input parameters. For the tungsten block, the end goal is the fatigue factor-of-safety (FOS). This study documents a new structural analysis routine using software available to U.S. national laboratories (e.g. CUBIT, Sierra Multiphysics, Dakota) that enables more rapid target fatigue analysis. The increased throughput is amenable to parameter sensitivity and uncertainty quantification (UQ) studies. A set of input parameters (ultimate strength, fatigue strength, density, elastic modulus, Poisson’s ratio, thermal conductivity, coefficient of thermal expansion, specific heat, flow rate) with expected ranges are documented based on literature data, recent experimental testing, and engineering judgement. UQ bounds the resulting fatigue FOS at [0.5, 3.4] using epistemic interval analysis. These bounds are expected to be wider due to model effects (discretization) and beam effects (focus, offset) that were not included. Parameter sensitivity underscores the importance of ultimate strength and fatigue strength of irradiated tungsten on the fatigue calculations.

43 PARTICLE ACCELERATORS↗

High-Peak-Power Long-Wave Infrared Lasers with CO2 Amplifiers

Long-wave infrared (LWIR) picosecond pulses with multi-terawatt peak power have recently become available for advanced high-energy physics and material research. Multi-joule pulse energy is achieved in an LWIR laser system via amplification of a microjoule seed pulse with high-pressure, mixed-isotope CO 2 amplifiers. A chirped-pulse amplification (CPA) scheme is employed in such a laser to reduce the nonlinear interaction between the optical field and the transmissive elements of the system. Presently, a research and development effort is underway towards an even higher LWIR peak power that is required, for instance, for promising particle acceleration schemes. The required boost of the peak power can be achieved by reducing the pulse duration to fractions of a picosecond. For this purpose, the possibility of reducing the gain narrowing in the laser amplifiers and post-compression techniques are being studied. Another direction in research is aimed at the increased throughput (i.e., repetition rate), efficiency, and reliability of LWIR laser systems. The transition from a traditional electric-discharge pumping to an optical pumping scheme for CO 2 amplifiers is expected to improve the robustness of high-peak-power LWIR lasers, making them suitable for broad implementation in scientific laboratory, industrial, and clinical environments.

43 PARTICLE ACCELERATORS↗

GSFC short pulse radar, JONSWAP-75

In September 1975, the Goddard Space Flight Center operated a short pulse radar during ocean wave measuring experiments off the coast of West Germany in the North Sea. The experiment was part of JONSWAP-75. The radar system and operations during the experiment are described along with examples of data.

Levine, D. M.↗

Test apparatus for locating shorts during assembly of electrical buses

A test apparatus is described for locating electrical shorts that is especially suited for use while an electrical circuit is being fabricated or assembled. A ring counter derives input pulses from a square wave oscillator. The outputs of the counter are fed through transistors to an array of light emitting diodes. Each diode is connected to an electrical conductor, such as a bus bar, that is to be tested. In the absence of a short between the electrical conductors the diodes are sequentially illuminated. When a short occurs, a comparator/multivibrator circuit triggers an alarm and stops the oscillator and the sequential energization of the diodes. The two diodes that remain illuminated identify the electrical conductors that are shorted.

Deboo, G. J.↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Results of an exploration of the relationship between ultrasonic attenuation and fatigue survivability of graphite fiber epoxy composites fabricated under different cure conditions are reported. A total of 9 27 x 40 cm eight-ply graphite epoxy laminated specimens were formed, and fatigue tests were run on five partial samples at 73.5 N varying at 30 Hz, with tests ending at a 1.27 cm deflection. A pulsed oscillator generated sinusoidal waves and transducers recorded the passage of the ultrasonic waves for display on oscilloscopes. Cure pressures ranged from 0.52-0.85 MPa and cure temperatures were in the 150-200 C interval. Ultrasonic through-transmission at 4 MHz was performed prior to and during fatigue testing. The minimum void volume fraction occurred at 175 C and 0.86 MPa. The flexural stiffness decreased with the number of fatigue cycles past 10,000, when the attenuation also increased. Correlations were found between the 4.0 MHz signal attenuation and the void volume fraction, and between the number of fatigue cycles to failure and the 4.0 MHz signal attenuation.

Williams, J. H., Jr.↗

On the interaction between the quasi-2-day wave and the mean flow

Studies of the quasi-2-day wave show that it is a summertime phenomenon. Long-term measurement of the winds in the 60 to 100 km height range at Adelaide show that the wave appears in the late December but that the peak amplitudes are not reached until mid-January. In the summer of 1983 to 1984 the main phase of the wave appeared as a pulse in mid-January which lasted about 7 cycles (14 days). Little or no amplification with height was observed; peak amplitudes were about 60 m/s for the meridional and 20 m/s for the zonal component. Coincident with the onset of the pulse, a temporary but substantial change occurred throughout a deep layer of the upper mesosphere over a period of about 3 days. A change of more than 10 m/s occurred in the northward flow while the change in the zonal flow (about 30 m/s westward) actually caused a reversal of the prevailing zonal circulation.

Craig, R. L.↗

Temporal sensitivity

Human visual temporal sensitivity is examined. The stimuli used to measure temporal sensitivity are described and the linear systems theory is reviewed in terms of temporal sensitivity. A working model which represents temporal sensitivity is proposed. The visibility of a number of temporal wave forms, sinusoids, rectangular pulses, and pulse pairs, is analyzed. The relation between spatial and temporal effects is studied. Temporal variations induced by image motion and the effects of light adaptation on temporal sensitivity are considered.

Watson, Andrew B.↗

Dendritic sidebranching in the three-dimensional symmetric model in the presence of noise

The time-dependent behavior of sidebranching deformations in the three-dimensional symmetric model of dendritic solidification is studied within a WKB approximation. Localized wave packets generated by pulses in the neighborhood of the tip are found to grow in amplitude and to spread and stretch as they move down the sides of the dendrite. This behavior is shown to imply that noise in the solidifying medium is selectively amplified in such a way as to produce a fluctuating train of sidebranches in qualitative agreement with experimental observations. A rough estimate indicates that purely thermal noise is probably not quite strong enough to fit the data.

Langer, J. S.↗

Direct solar-pumped iodine laser amplifier

The optimum conditions of a solar pumped iodine laser are found in this research for the case of a continuous wave operation and a pulsed operation. The optimum product of the pressure(p) inside the laser tube and the tube diameter(d) was pd=40 approx. 50 torr-cm on the contrary to the case of a high intensity flashlamp pumped iodine laser where the optimum value of the product is known to be pd=150 torr-cm. The pressure-diameter product is less than 1/3 of that of the high power iodine laser. During the research period, various laser materials were also studied for solar pumping. Among the laser materials, Nd:YAG is found to have the lowest laser threshold pumping intensity of about 200 solar constant. The Rhodamine 6G was also tested as the solar pumped laser material. The threshold pumping power was measured to be about 20,000 solar constant. The amplification experiment for a continuously pumped iodine laser amplifier was performed using Vortek solar simulator and the amplification factors were measured for single pass amplification and triple pass amplification of the 15 cm long amplifier tube. The amplification of 5 was obtained for the triple pass amplification.

Han, Kwang S.↗

Atmospheric aerosol and Doppler lidar studies

Experimental and theoretical studies were performed of atmospheric aerosol backscatter and atmospheric dynamics with Doppler lidar as a primary tool. Activities include field and laboratory measurement and analysis efforts. The primary focus of activities related to understanding aerosol backscatter is the GLObal Backscatter Experiment (GLOBE) program. GLOBE is a multi-element effort designed toward developing a global aerosol model to describe tropospheric clean background backscatter conditions that Laser Atmospheric Wind Sounder (LAWS) is likely to encounter. Two survey missions were designed and flown in the NASA DC-8 in November 1989 and May to June 1990 over the remote Pacific Ocean, a region where backscatter values are low and where LAWS wind measurements could make a major contribution. The instrument complement consisted of pulsed and continuous-wave (CW) CO2 gas and solid state lidars measuring aerosol backscatter, optical particle counters measuring aerosol concentration, size distribution, and chemical composition, a filter/impactor system collecting aerosol samples for subsequent analysis, and integrating nephelometers measuring visible scattering coefficients. The GLOBE instrument package and survey missions were carefully planned to achieve complementary measurements under clean background backscatter conditions.

Rothermel, Jeff↗