At least 811 records · Page 45

Multidimensional resonance raman spectroscopy by six-wave mixing in the deep UV

Two-dimensional (2D) resonance Raman spectroscopies hold great potential for uncovering photoinduced relaxation processes in molecules but are not yet widely applied because of technical challenges. Here, we describe a newly developed 2D resonance Raman experiment operational at the third-harmonic of a Titanium-Sapphire laser. High-sensitivity and rapid data acquisition are achieved by combining spectral interferometry with a background-free (six-pulse) laser beam geometry. The third-harmonic laser pulses are generated in a filament produced by the fundamental and second-harmonic pulses in neon gas at pressures up to 35 atm. The capabilities of the setup are demonstrated by probing ground-state wavepacket motions in triiodide. The information provided by the experiment is explored with two different representations of the signal. In one representation, Fourier transforms are carried out with respect to the two experimentally controlled delay times to obtain a 2D Raman spectrum. Further insights are derived in a second representation by dispersing the signal pulse in a spectrometer. It is shown that, as in traditional pump-probe experiments, the six-wave mixing signal spectrum encodes the wavepacket's position by way of the (time-evolving) emission frequency. Anharmonicity additionally induces dynamics in the vibrational resonance frequency. In all cases, the experimental signals are compared to model calculations based on a cumulant expansion approach. This study suggests that multi-dimensional resonance Raman spectroscopies conducted on systems with Franck-Condon active modes are fairly immune to many of the technical issues that challenge off-resonant 2D Raman spectroscopies (e.g., third-order cascades) and photon-echo experiments in the deep UV (e.g., coherence spikes). The development of higher-order nonlinear spectroscopies operational in the deep UV is motivated by studies of biological systems and elementary organic photochemistries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An innovative Yb-based ultrafast deep ultraviolet source for time-resolved photoemission experiments

Time- and angle-resolved photoemission spectroscopy is a powerful technique to study ultrafast electronic dynamics in solids. Here, an innovative optical setup based on a 100-kHz Yb laser source is presented. Exploiting non-collinear optical parametric amplification and sum-frequency generation, ultrashort pump (hν = 1.82 eV) and ultraviolet probe (hν = 6.05 eV) pulses are generated. Overall temporal and instrumental energy resolutions of, respectively, 85 fs and 50 meV are obtained. Time- and angle-resolved measurements on BiTeI semiconductor are presented to show the capabilities of the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double Optical Gating of High-Order Harmonic Generation with Carrier-Envelope Phase Stabilized Lasers

We demonstrated a novel optical switch to control the high-order harmonic generation process so that single attosecond pulses can be generated with multiple-cycle pulses. The technique combines two powerful optical gating methods: polarization gating and two-color gating. An extreme ultraviolet supercontinuum supporting 130 as was generated with neon gas using 9 fs laser pulses. We discovered a unique dependence of the harmonic spectra on the carrier-envelope phase of the laser fields, which repeats every 2{pi} radians.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal generation of spatially coherent soft X-ray isolated attosecond pulses in a gas-filled waveguide using two-color synthesized laser pulses

Here, we numerically demonstrate the generation of intense, low-divergence soft X-ray isolated attosecond pulses in a gas-filled hollow waveguide using synthesized few-cycle two-color laser waveforms. The waveform is a superposition of a fundamental and its second harmonic optimized such that highest harmonic yields are emitted from each atom. We then optimize the gas pressure and the length and radius of the waveguide such that bright coherent high-order harmonics with angular divergence smaller than 1 mrad are generated, for photon energy from the extreme ultraviolet to soft X-rays. By selecting a proper spectral range enhanced isolated attosecond pulses are generated. We study how dynamic phase matching caused by the interplay among waveguide mode, neutral atomic dispersion, and plasma effect is achieved at the optimal macroscopic conditions, by performing time-frequency analysis and by analyzing the evolution of the driving laser’s electric field during the propagation. Our results, when combined with the on-going push of high-repetition-rate lasers (sub- to few MHz’s) may eventually lead to the generation of high-flux, low-divergence soft X-ray tabletop isolated attosecond pulses for applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-pulsing 10{sup 4} A cm{sup -2} current density discharges in dielectric barrier Al/Al{sub 2}O{sub 3} microplasma devices

Excitation of Al/Al{sub 2}O{sub 3} microplasma devices with 50 {mu}s, 800 V pulses produces, in Ar/H{sub 2} gas mixtures at 600 Torr, {approx}6 A current pulses with a duration of {approx}30 ns. Corresponding to peak current and power densities of {approx}10{sup 4} A/cm{sup 2} and {approx}2.5 GW/cm{sup 3}, respectively, these pulses are generated in a 10 {mu}s burst in which the voltage self-pulses at a repetition frequency of {approx}3 MHz. Analysis of the H{sub {alpha}}, H{sub {beta}}, and Ar II emission line profiles yields a plasma density of {approx}10{sup 17} cm{sup -3}, and the emission of O IV ions suggests the presence of energetic electrons. Images of the microplasma indicate that the plasma is initiated by surface flashover and extends {approx}200 {mu}m outside the microcavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Double-shot MeV electron diffraction and microscopy

Here in this paper, we study by numerical simulations a time-resolved MeV electron scattering mode where two consecutive electron pulses are used to capture the evolution of a material sample on 10 ps time scales. The two electron pulses are generated by illuminating a photocathode in a radiofrequency photogun by two short laser pulses with adjustable delay. A streak camera/deflecting cavity is used after the sample to project the two electron bunches on two well separated regions of the detector screen. By using sufficiently short pulses, the 2D spatial information from each snapshot can be preserved. This “double-shot” technique enables the efficient capture of irreversible dynamics in both diffraction and imaging modes. Finally, in this work, we demonstrate both modes in start-to-end simulations of the UCLA Pegasus MeV microscope column.

36 MATERIALS SCIENCE↗

Voltage and Current Response Characteristics of PMU Device by PCI Simulation

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of power system will be affected directly and greatly. As new electronic devices in power system, their immunity to electromagnetic pulse (EMP) events needs to be studied. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. A non-uniform transmission line model is established to eliminate the impact of fixture in the de-embedding process. Then circuit of pulse current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) simulation. Results shows the characteristics of port impedance, voltage and current waveforms. The relation between port impedance and the waveforms is discussed.

Zhang, Liang↗

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

Phasor Measurement Units (PMUs) are critical for the Wide Area Measurement System (WAMS), especially for real-time grid monitoring, disturbance location, and situation awareness. Once they are damaged, the stable operation of the power system will be affected directly and greatly. Therefore, it is urgent and necessary to study their immunity to electromagnetic pulse (EMP) events. In this paper, an effective impedance measurement scheme is proposed for port impedance measurement of PMU. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then circuit of pulsed current generator is established to generate damping sinusoid and double exponential wave applied to the port. Finally, by using measured impedance as a load of the generator, the voltage and current responses of different ports are calculated in the pulsed current injection (PCI) testing simulation. Results show that common-mode impedance is large and differential mode impedance is small. The critical condition will appear in the common mode for voltage and differential mode for current.

Zhang, Liang↗

High harmonic generation in graphene quantum dots

Abstract We study theoretically the generation of high harmonics in disk graphene quantum dots placed in linearly polarized short pulse. The quantum dots (QD) are described within an effective model of the Dirac type and the length gauge was used to describe the interaction of quantum dots with an optical pulse. The generated radiation spectra of graphene quantum dots can be controlled by varying the quantum dot size, i.e. its radius. With increasing the quantum dot radius, the intensities of low harmonics mainly decrease, while the cutoff frequency increases. The sensitivity of the cutoff frequency to the QD size increases with the intensity of the pulse.

Physics↗

Temporal development of ion beam mean charge state in pulsed vacuum arc ion sources

Vacuum arc ion sources, commonly also known as 'Mevva' ion sources, are used to generate intense pulsed metal ion beams. It is known that the mean charge state of the ion beam lies between 1 and 4, depending on cathode material, arc current, arc pulse duration, presence or absence of magnetic field at the cathode, as well as background gas pressure. A characteristic of the vacuum arc ion beam is a significant decrease in ion charge state throughout the pulse. This decrease can be observed up to a few milliseconds, until a ''noisy'' steady-state value is established. Since the extraction voltage is constant, a decrease in the ion charge state has a proportional impact on the average ion beam energy. This paper presents results of detailed investigations of the influence of arc parameters on the temporal development of the ion beam mean charge state for a wide range of cathode materials. It is shown that for fixed pulse duration, the charge state decrease can be reduced by lower arc current, higher pulse repetition rate, and reduction of the distance between cathode and extraction region. The latter effect may be associated with charge exchange processes in the discharge plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MeV proton beams generated by 3 mJ ultrafast laser pulses at 0.5 kHz

Well-collimated proton beams are generated from bulk glass along the target normal direction by tightly focused 55 fs, 3 mJ pulses from a laser operating at 0.5 kHz repetition rate. Proton beams with energies of >265 keV have an emission angle of about 16 deg. full width at half maximum. Spectral measurements indicate proton energies exceeding 0.5 MeV with a flux of 3.2x10{sup 9} s{sup -1} sr{sup -1} and the flux of measured protons with energies of greater than 90 keV is 8.5x10{sup 11} s{sup -1} sr{sup -1} on center.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

R&D100: LED Pulser

A Sandia National Laboratories' light emitting diode (LED) driver is generating light pulses with shorter duration higher repetition frequency and higher brightness than anything on the market. The Sandia LED Pulser uses custom electronic circuitry to drive high-power LEDs to generate short, bright, high frequency light pulses. A single device can emit up to four different colors - each with independent pulse timing - crucial for light-beam forming in many optical applications and is more economical than current light sources such as lasers.

36 MATERIALS SCIENCE↗

Plasma electron source for the generation of wide-aperture pulsed beam at forevacuum pressures

This article reports on design and application of wide-aperture pulsed beam source, based on hollow cathode discharge. The source is intended for electron beam generation in pressure range 2-15 Pa. Multi-aperture extraction system, used in a source, provided beam cross-section uniformity of 10% on diameter 40 mm. The limiting values of the current density, pulse duration, and accelerating voltage are 350 mA/cm{sup 2}, 250 {mu}s, and 10 kV, respectively. These parameters are sufficient for surface modification of various materials, including non-conducting matters.

43 PARTICLE ACCELERATORS↗

Noise Radar Approach for Interrogating SAW Sensors Using Software Defined Radio

Passive, wireless surface acoustic wave (SAW) sensor systems can be approached from a radar perspective, where the SAW device is thought of as a cooperative target. Here, this paper investigates the use of a commercial-off-the-shelf software defined radio to interrogate wireless SAW sensors with a randomly generated interrogation pulse. The USRP B200mini is utilized as the transceiver platform with custom field-programmable gate array (FPGA) modifications to generate the random interrogation waveform and provide synchronization and buffering to the received signal. Each transmit sample bit in the FPGA is fed by an independent linear-feedback shift register, which generates pseudo-random I and Q samples for the interrogation pulse. An RF daughterboard has also been developed and integrated with the B200mini to increase the transmit power, provide filtering of the RF signals, and switch a signal antenna between the transmit and receive channels. Radio control and matched filter correlator post-processing are accomplished using Python. Design and implementation details for the FPGA modifications, RF daughterboard, and post-processing are discussed. Lastly, the system is demonstrated by wirelessly interrogating SAW temperature sensors at 915 MHz.

47 OTHER INSTRUMENTATION↗

Study of laser produced plasma in a longitudinal magnetic field

In this work, laser produced plasma embedded in a longitudinal magnetic field was studied using a 1 MA pulsed power generator coupled with a 50 TW laser. Half turn coil loads with an internal diameter of 2.5–3.5 mm generate a 50–70 T axial magnetic field near the load. A subpicosecond laser pulse with an intensity of 10 18 –10 19 W/cm 2 irradiates a thin Si foil target in the magnetic field of the coil load. A laser produced plasma plume collimates within the longitudinal field to a narrow jet 0.2–0.3 mm in diameter with a length of 3–4 mm and an electron plasma density of (0.2–1) × 10 20 cm ₋3 on the jet axis. The jet propagates with a velocity of 160–200 km/s in general agreement with magnetohydrodynamic simulations. X-ray spectral measurements demonstrate an increase in the plasma electron density resulting from the magnetic confinement of the jet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An overview of magneto-inertial fusion on the Z Machine at Sandia National Laboratories

We present an overview of the magneto-inertial fusion (MIF) concept MagLIF (Magnetized Liner Inertial Fusion) pursued at Sandia National Laboratories and review some of the most prominent results since the initial experiments in 2013. In MagLIF, a centimeter-scale beryllium tube or "liner" is filled with a fusion fuel, axially pre-magnetized, laser pre-heated, and finally imploded using up to 20 MA from the Z machine. All of these elements are necessary to generate a thermonuclear plasma: laser preheating raises the initial temperature of the fuel, the electrical current implodes the liner and quasi-adiabatically compresses the fuel via the Lorentz force, and the axial magnetic field limits thermal conduction from the hot plasma to the cold liner walls during the implosion. MagLIF is the first MIF concept to demonstrate fusion relevant temperatures, significant fusion production (>10^13 primary DD neutron yield), and magnetic trapping of charged fusion particles. On a 60 MA next-generation pulsed-power machine, two-dimensional simulations suggest that MagLIF has the potential to generate multi-MJ yields with significant self-heating, a long-term goal of the US Stockpile Stewardship Program. At currents exceeding 65 MA, the high gains required for fusion energy could be achievable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffusion Models to Construct a First Principles Multipole-Based Cable Braid Model for Conducting Wires in the Time Domain

We describe here diffusion models apt to construct a multipole-based, cable braid time domain model for conducting wires. Implementation details of both a ladder network valid for time-domain signals with all frequency content and an approximate single-stage circuit valid for low-frequency dominated time signals (such as electromagnetic pulses) are reported. This time domain model can be leveraged to treat system-generated electromagnetic pulse events, as well as used to further confirm the correctness of the multipole-based, cable braid frequency domain model.

42 ENGINEERING↗

Preliminary Analysis of Damage to MPFDs Caused by Reactor Pulses

The need for next-generation, accident-tolerant fuels has generated significant interest in the restart of domestic fuels testing at the Transient Reactor Test (TREAT) facility. The TREAT reactor is designed to produce large, transient fluxes that replicate the effects of a wide variety of accident conditions on an irradiated fuel sample. Peak powers generated during short pulses approach 20 GW with a neutron flux of approximately 10{sup 17} n cm{sup -2} s{sup -1}. As part of the restart effort, new vehicle designs are being explored for sample irradiation, including the Static Environment Rodlet Transient Test Apparatus (SERTTA) and variants. As part of the SERTTA designs, micro-pocket fission detectors (MPFDs) are being explored for localized flux measurements before, during, and after transient operations. These detectors are also being considered as part of future, core-wide instrumentation for the TREAT reactor. However, the high fluxes associated with the pulses in the TREAT core present certain thermodynamic concerns given their intensity and the amount of energy they will release within the MPFDs within such a short amount of time. Assuming each fission that occurs in a MPFD results in a fission fragment depositing 85 MeV of energy in the substrate on average and each MPFD has 0.5 μg of natural uranium deposited on it, a 100 ms long pulse in the TREAT reactor at 1017 n cm{sup -2} s{sup -1} flux will produce approximately 4.6 x 10{sup 6} fissions in an MPFD. This pulse deposits 6.3 x 10{sup -5} J in the substrate over a 100 ms duration. That amount of energy is sufficient to melt roughly 33% of the Pt under the UO{sub 2} deposition or a circular spot with a diameter of approximately 860 μm. Of course, the above estimate makes a number of simplifying assumptions and ignores heat transfer, but does serve to illustrate the point that this rapid heating effect could be detrimental to the integrity and life of these in-core MPFDs. To study how these layers are affected by large transient neutron fluxes, five samples were prepared, pre-analyzed, and then subjected to a pulse in the central thimble of the Kansas State University TRIGA Mark II reactor to a peak power of 1.58 GW. After being allowed to decay to safer radiation levels, the sample substrates and coatings were inspected using scanning electron microscopy (SEM) to identify any changes to their surface morphology. Indeed, certain changes were found and are discussed in greater detail in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗