Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Detection of Critical Surface Features in PTLs and GDLs for Improved Device Performance and Manufacturing Reliability

High points, or features that protrude above the surface of the material, on porous transport layers (PTLs) and gas diffusion layers (GDLs) can be critical features that may affect the manufacturing process and the performance of the device containing the feature. High points on PTLs and GDLs may stress the membrane of a polymer electrolyte membrane (PEM) during lamination and cell operation of a PEM electrolyzer or fuel cell. Additionally, high points on GDLs may impact the reliability of the manufacturing process. Thus, understanding these critical features and developing procedures to detect them are a key part of developing quality control techniques for PTLs and GDLs. This work evaluates the effectiveness of the Keyence VR6200 benchtop-scale structured light optical profilometer for detection of surface protrusions on PTLs and GDLs. Standard testing procedures for detecting and measuring high points were created for use on both material types. These procedures were evaluated using Gage Repeatability and Reproducibility (Gage R&R), where the repeatability, reproducibility, and effectiveness of the system to detect and measure high points were quantified. We have shown with high statistical power that the system is very effective in detection and measurement of high points, with Gage R&R contributions measured to be 2.2% and 3.6% for PTLs and GDLs, respectively.

36 MATERIALS SCIENCE↗

WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-206-02: ACR Ultrasound Accreditation: Requirements and Pitfalls

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Molecular cloning and characterization of a novel isoform of the non-canonical poly(A) polymerase PAPD7

Highlights: ► So far, only an enzymatically inactive isoform of PAPD7 was reported. ► The novel isoform: PAPD7 l shows robust nucleotidyl transferase activity. ► The newly identified amino terminal region is required for the activity. ► PAPD7 l localizes to the nucleoplasm. ► The N terminal region identified is also required for the nuclear localization. - Abstract: Non-canonical poly(A) polymerases (ncPAPs) catalyze the addition of poly(A) tail to the 3′ end of RNA to play pivotal roles in the regulation of gene expression and also in quality control. Here we identified a novel isoform of the 7th member of ncPAPs: PAPD7 (PAPD7 l), which contains 230 extra amino acids at the amino terminus of the previously identified PAPD7 (PAPD7 s). In sharp contrast to the inactive PAPD7 s, PAPD7 l showed robust nucleotidyl transferase activity when tethered to an RNA. A region required for the activity was localized to 187–219 aa, and this region was also required for the nuclear retention of PAPD7 l. Western blot analysis revealed that 94 kDa band (corresponding to PAPD7 l) but not 62 kDa band (corresponding to PAPD7 s) detected by PAPD7 antibody was specifically depleted by treatment with PAPD7 siRNA in both HeLa and U2OS cells. These results suggest that PAPD7 l is the major and active isoform of PAPD7 expressed in cells.

60 APPLIED LIFE SCIENCES↗

TRACING COLD H I GAS IN NEARBY, LOW-MASS GALAXIES

We analyze line-of-sight atomic hydrogen (H I) line profiles of 31 nearby, low-mass galaxies selected from the Very Large Array-ACS Nearby Galaxy Survey Treasury (VLA-ANGST) and The H I Nearby Galaxy Survey (THINGS) to trace regions containing cold (T {approx}< 1400 K) H I from observations with a uniform linear scale of 200 pc beam{sup -1}. Our galaxy sample spans four orders of magnitude in total H I mass and nine magnitudes in M{sub B} . We fit single and multiple component functions to each spectrum to isolate the cold, neutral medium given by a low-dispersion (<6 km s{sup -1}) component of the spectrum. Most H I spectra are adequately fit by a single Gaussian with a dispersion of 8-12 km s{sup -1}. Cold H I is found in 23 of 27 ({approx}85%) galaxies after a reduction of the sample size due to quality-control cuts. The cold H I contributes {approx}20% of the total line-of-sight flux when found with warm H I. Spectra best fit by a single Gaussian, but dominated by cold H I emission (i.e., have velocity dispersions of <6 km s{sup -1}), are found primarily beyond the optical radius of the host galaxy. The cold H I is typically found in localized regions and is generally not coincident with the very highest surface density peaks of the global H I distribution (which are usually areas of recent star formation). We find a lower limit for the mass fraction of cold-to-total H I gas of only a few percent in each galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Laser photothermal radiometric instrumentation for fast in-line industrial steel hardness inspection and case depth measurements

A contact-free, nondestructive laser photothermal radiometric instrumentation technique was developed to meet industrial demand for on-line steel hardness inspection and quality control. A series of industrial steel samples, flat or curvilinear, with different effective hardness case depths ranging between 0.21 and 1.78 mm were measured. The results demonstrated that three measurement parameters (metrics) extracted from fast swept-sine photothermal excitation and measurements, namely, the phase minimum frequency fmin, the peak or trough frequency width W, and the area S, are complementary for evaluating widely different ranges of hardness case depth: fmin is most suitable for large case depths, and W and S for small case depths. It was also found that laser beam angular inclination with respect to the surface plane of the sample strongly affects hardness measurement resolution and that the phase frequency maximum is more reliable than the amplitude maximum for laser beam focusing on the sample surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-AB-206-03: Workshop

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimizing a Small RNAseq Analysis Pipeline for NASA GeneLab Using Open-Source Tools and Libraries

Small RNA sequencing (small RNAseq) is a powerful tool for studying the regulation of gene expression in various organisms. Small RNAseq has been leveraged in space biology research to study how expression of small RNAs, e.g. micro RNAs (miRNAs), small interfering RNAs (siRNAs), and piwi-interacting RNAs (piRNAs), change upon exposure to the space environment. NASA GeneLab currently hosts small RNAseq raw data derived from space-relevant experiments on the Open Science Data Repository (OSDR). To maximize the accessibility of these data to the scientific community, in addition to hosting raw data, which is only interpretable by bioinformaticians, GeneLab plans to process all small RNAseq datasets and make those processed data available to the scientific community via the OSDR. In this study, we present the development of the GeneLab standardized pipeline for processing small RNAseq datasets. Using human, plant, and synthetic small RNAseq datasets, we interrogate various open-source software and publicly available databases to evaluate their accuracy and reproducibility in each step of the pipeline. For quality control and adapter detection and trimming, we evaluated TrimGalore!, FASTX, SeqKit, and DNApi methods to optimize alignment to reference genomes. We compared BWA, Bowtie, and Bowtie2 to determine the optimal alignment tool. For each alignment tool we also assessed various reference databases, including Ensembl reference genomes and different types of small RNA reference databases, including genome, hairpin, and miRNA references from the miRbase and MirGeneDB databases. To quantify the aligned data, we compared SAMtools, HTSeq, and RSEM for counting alignment events from each alignment tool used. Finally, we evaluated various tools, including DESeq2 and EdgeR, for data normalization and subsequent differential expression analysis. We will present the results from our comparative analyses for each pipeline step and propose a consensus pipeline for processing small RNAseq data derived from various organisms exposed to the space environment.

SmallRNAseq, NASA GeneLab, quality control, adapte↗

Examination of a Size-Change Test for Photovoltaic Encapsulation Materials (Presentation)

We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International Electrotechnical Commission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sand substrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/- 5C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). The test procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/- 5% between laboratories.

14 SOLAR ENERGY↗

INITIAL DATA RELEASE OF THE KEPLER-INT SURVEY

This paper describes the first data release of the Kepler-INT Survey (KIS) that covers a 116 deg{sup 2} region of the Cygnus and Lyra constellations. The Kepler field is the target of the most intensive search for transiting planets to date. Despite the fact that the Kepler mission provides superior time-series photometry, with an enormous impact on all areas of stellar variability, its field lacks optical photometry complete to the confusion limit of the Kepler instrument necessary for selecting various classes of targets. For this reason, we follow the observing strategy and data reduction method used in the IPHAS and UVEX galactic plane surveys in order to produce a deep optical survey of the Kepler field. This initial release concerns data taken between 2011 May and August, using the Isaac Newton Telescope on the island of La Palma. Four broadband filters were used, U, g, r, i, as well as one narrowband one, H{alpha}, reaching down to a 10{sigma} limit of {approx}20th mag in the Vega system. Observations covering {approx}50 deg{sup 2}, thus about half of the field, passed our quality control thresholds and constitute this first data release. We derive a global photometric calibration by placing the KIS magnitudes as close as possible to the Kepler Input Catalog (KIC) photometry. The initial data release catalog containing around 6 million sources from all the good photometric fields is available for download from the KIS Web site (www.astro.warwick.ac.uk/research/kis/) as well as via MAST (KIS magnitudes can be retrieved using the MAST enhanced target search page http://archive.stsci.edu/kepler/kepler{sub f}ov/search.php and also via Casjobs at MAST Web site http://mastweb.stsci.edu/kplrcasjobs/).

79 ASTRONOMY AND ASTROPHYSICS↗

Solid state dosimeters used in medical physics 'A review'

Many solid-state detectors have been successfully used to perform the quality control and in vivo dosimetry in medical physics, both in diagnostic radiology and radiotherapy, as they have high sensitivity in a small volume; most of them do not require electrical connection and have dosimetric characteristics of interest such as: good accuracy and reproducibility, as well as a response independent of the energy of radiation, some of them. For this reason, the selection of an appropriate detector for use in medical physics must take into account the energy mass absorption coefficient relative to water for photon sources and the mass stopping power relative to water for beta emitters and electron beams in the energy range of interest in medical physics, as well as the effective atomic number of materials that constitute them. This paper presents a review of the dosimetric characteristics of the solid state dosimeters most suitable for use in medical physics.

61 RADIATION PROTECTION AND DOSIMETRY↗

A widefield fluorescence microscope with a linear image sensor for image cytometry of biospecimens: Considerations for image quality optimization

Linear image sensors have been widely used in numerous research and industry applications to provide continuous imaging of moving objects. Here, we present a widefield fluorescence microscope with a linear image sensor used to image translating objects for image cytometry. First, a calibration curve was characterized for a custom microfluidic chamber over a span of volumetric pump rates. Image data were also acquired using 15 μm fluorescent polystyrene spheres on a slide with a motorized translation stage in order to match linear translation speed with line exposure periods to preserve the image aspect ratio. Aspect ratios were then calculated after imaging to ensure quality control of image data. Fluorescent beads were imaged in suspension flowing through the microfluidics chamber being pumped by a mechanical syringe pump at 16 μl min{sup −1} with a line exposure period of 150 μs. The line period was selected to acquire images of fluorescent beads with a 40 dB signal-to-background ratio. A motorized translation stage was then used to transport conventional glass slides of stained cellular biospecimens. Whole blood collected from healthy volunteers was stained with 0.02% (w/v) proflavine hemisulfate was imaged to highlight leukocyte morphology with a 1.56 mm × 1.28 mm field of view (1540 ms total acquisition time). Oral squamous cells were also collected from healthy volunteers and stained with 0.01% (w/v) proflavine hemisulfate to demonstrate quantifiable subcellular features and an average nuclear to cytoplasmic ratio of 0.03 (n = 75), with a resolution of 0.31 μm pixels{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-421: Failure Mode and Effects Analysis (FMEA) of Xoft Electronic Brachytherapy for the Treatment of Superficial Skin Cancers

Purpose: To perform a failure mode and effects analysis (FMEA) of the process for treating superficial skin cancers with the Xoft Axxent electronic brachytherapy (eBx) system, given the recent introduction of expanded quality control (QC) initiatives at our institution. Methods: A process map was developed listing all steps in superficial treatments with Xoft eBx, from the initial patient consult to the completion of the treatment course. The process map guided the FMEA to identify the failure modes for each step in the treatment workflow and assign Risk Priority Numbers (RPN), calculated as the product of the failure mode’s probability of occurrence (O), severity (S) and lack of detectability (D). FMEA was done with and without the inclusion of recent QC initiatives such as increased staffing, physics oversight, standardized source calibration, treatment planning and documentation. The failure modes with the highest RPNs were identified and contrasted before and after introduction of the QC initiatives. Results: Based on the FMEA, the failure modes with the highest RPN were related to source calibration, treatment planning, and patient setup/treatment delivery (Fig. 1). The introduction of additional physics oversight, standardized planning and safety initiatives such as checklists and time-outs reduced the RPNs of these failure modes. High-risk failure modes that could be mitigated with improved hardware and software interlocks were identified. Conclusion: The FMEA analysis identified the steps in the treatment process presenting the highest risk. The introduction of enhanced QC initiatives mitigated the risk of some of these failure modes by decreasing their probability of occurrence and increasing their detectability. This analysis demonstrates the importance of well-designed QC policies, procedures and oversight in a Xoft eBx programme for treatment of superficial skin cancers. Unresolved high risk failure modes highlight the need for non-procedural quality initiatives such as improved planning software and more robust hardware interlock systems.

60 APPLIED LIFE SCIENCES↗

Formation of distinct inclusion bodies by inhibition of ubiquitin-proteasome and autophagy-lysosome pathways

Research highlights: {yields} Distinct inclusion bodies are developed by inhibition of UPP and ALP. {yields} The inclusion bodies differ in morphology, localization and formation process. {yields} The inclusion bodies are distinguishable by the localization of TSC2. {yields} Inhibition of both UPP and ALP simultaneously induces those inclusion bodies. -- Abstract: Accumulation of misfolded proteins is caused by the impairment of protein quality control systems, such as ubiquitin-proteasome pathway (UPP) and autophagy-lysosome pathway (ALP). In this study, the formation of inclusion bodies was examined after the blockade of UPP and/or ALP in A549 cells. UPP inhibition induced a single and large inclusion body localized in microtubule-organizing center. Interestingly, however, ALP inhibition generated dispersed small inclusion bodies in the cytoplasm. Tuberous sclerosis complex 2 was selectively accumulated in the inclusion bodies of UPP-inhibited cells, but not those of ALP-inhibited cells. Blockade of transcription and translation entirely inhibited the formation of inclusion body induced by UPP inhibition, but partially by ALP inhibition. Moreover, the simultaneous inhibition of two protein catabolic pathways independently developed two distinct inclusion bodies within a single cell. These findings clearly demonstrated that dysfunction of each catabolic pathway induced formation and accumulation of unique inclusion bodies on the basis of morphology, localization and formation process in A549 cells.

60 APPLIED LIFE SCIENCES↗

A comprehensive review of the lipid cubic phase or in meso method for crystallizing membrane and soluble proteins and complexes

A comprehensive and up-to-date review of the lipid cubic phase or in meso method for crystallizing membrane and soluble proteins and complexes is reported. Recent applications of the method for in situ serial crystallography at X-ray free-electron lasers and synchrotrons are described. The lipid cubic phase or in meso method is a robust approach for crystallizing membrane proteins for structure determination. The uptake of the method is such that it is experiencing what can only be described as explosive growth. This timely, comprehensive and up-to-date review introduces the reader to the practice of in meso crystallogenesis, to the associated challenges and to their solutions. A model of how crystallization comes about mechanistically is presented for a more rational approach to crystallization. The possible involvement of the lamellar and inverted hexagonal phases in crystallogenesis and the application of the method to water-soluble, monotopic and lipid-anchored proteins are addressed. How to set up trials manually and automatically with a robot is introduced with reference to open-access online videos that provide a practical guide to all aspects of the method. These range from protein reconstitution to crystal harvesting from the hosting mesophase, which is noted for its viscosity and stickiness. The sponge phase, as an alternative medium in which to perform crystallization, is described. The compatibility of the method with additive lipids, detergents, precipitant-screen components and materials carried along with the protein such as denaturants and reducing agents is considered. The powerful host and additive lipid-screening strategies are described along with how samples that have low protein concentration and cell-free expressed protein can be used. Assaying the protein reconstituted in the bilayer of the cubic phase for function is an important element of quality control and is detailed. Host lipid design for crystallization at low temperatures and for large proteins and complexes is outlined. Experimental phasing by heavy-atom derivatization, soaking or co-crystallization is routine and the approaches that have been implemented to date are described. An overview and a breakdown by family and function of the close to 200 published structures that have been obtained using in meso-grown crystals are given. Recommendations for conducting the screening process to give a more productive outcome are summarized. The fact that the in meso method also works with soluble proteins should not be overlooked. Recent applications of the method for in situ serial crystallography at X-ray free-electron lasers and synchrotrons are described. The review ends with a view to the future and to the bright prospects for the method, which continues to contribute to our understanding of the molecular mechanisms of some of nature’s most valued proteinaceous robots.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-H-207B-00: MRgRT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-02: MR-Driven RT Planning

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗