Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Cancellation of RF Coupler-Induced Emittance Due to Astigmatism

It is well-known that the electron beam quality required for applications such as FEL’s and ultra-fast electron diffraction can be degraded by the asymmetric fields introduced by the RF couplers of superconducting linacs. This effect is especially troublesome in the injector where the low energy beam from the gun is captured into the first high gradient accelerator section. Unfortunately modifying the established cavity design is expensive and time consuming, especially considering that only one or two sections are needed for an injector. Instead, it is important to analyze the coupler fields to understand their characteristics and help find less costly solutions for their cancellation and mitigation. This paper finds the RF coupler-induced emittance for short bunches is mostly due to the transverse spatial sloping or tilt of the field, rather than the field’s time-dependence. It is shown that the distorting effects of the coupler can be canceled with a static (DC) quadrupole lens rotated about the z-axis.

43 PARTICLE ACCELERATORS↗

The Design of the Parallel Box Cavity with New Radial RF Coupler Design

The design of a E/H parallel cavity has been described. It has been designed with the RF simulation program HFSS. HFSS has been very successfully been used to design and fabricate the Orthogonal E/H box cavity. The main reason for this design choice is to move the RF coupling aperture to surface of minimum electric field gradient. It is suspected that this change will remove the damaged observed in the coupling area experimentally observed in the LBL Pillbox cavity. Another reason for this change is that it corresponds to the location of the coupling aperture in a future real experimental cooling channel. Also, with this design the coupling factor to the cavity can be made adjustable externally, a very useful feature.

43 PARTICLE ACCELERATORS↗

Adaptive compensation of Lorentz force detuning in superconducting RF cavities

Here, the Lorentz force can dynamically detune pulsed Superconducting RF cavities and considerable additional RF power can be required to maintain the accelerating gradient if no effort is made to compensate. Fermilab has developed an adaptive compensation system for cavities in the Horizontal Test Stand, in the SRF Accelerator Test Facility, and for the proposed Project X.

43 PARTICLE ACCELERATORS↗

Direct Measurement of Backstreaming Ions from the Axis 2 Septum Dump and RF Generation

The DARHT-II accelerator produces a 2-kA, 17-MeV beam in a 1600-ns pulse. After exiting the accelerator, the pulse is sliced into four short pulses by a kicker and quadrupole septum and then transported for several meters to a high Z material target for conversion to x-rays for radiography. The un-kicked beam is diverted to a graphite dump. The interaction of this beam with the dump produces ions that propagate back to the target beamline and affect the beam properties. Coupling of the electron beam and ions to the beam dump vacuum chamber can also produce significant amounts of radiofrequency fields (RF) that disrupt the beam transport to the target. This requires a change in the nominal tune in order to minimize the heating of the carbon beam dump and suppress desorption of ions. Initially, ions are generated through stimulated desorption and ionization of the monolayers of water vapor stuck to the beam dump surface. These ions propagate upstream at high speeds and act as an electrostatic focusing lens by reducing the beam space charge. As the beam size on the dump decreases, the dump is sufficiently heated so that a surface plasma is formed and much greater quantities of ions are generated through temperature limited thermionic emission. The interaction of these ions with the beam creates RF which causes significant disruption of the beam. The results of a 3D PIC simulation show that ions can propagate back to the target beam line in about 500 ns. A beam position monitor (BPM) located just upstream of the septum was modified to include four capacitive pickups in addition to four of the usual inductive pickups. The inductive and capacitive pickups provide a measure of the beam current. The capacitive pickups are very sensitive to low velocity ions. As ions from the beam dump pass through the BPM the inductive and capacitive pickup will record two different measures of the beam current. Initial results from this BPM will be discussed along with other measurements which indicate the presence of backstreaming ions.

43 PARTICLE ACCELERATORS↗

Compact, Tunable RF Cavities

Compact RF cavities that tune rapidly over various frequency ranges are being developed using an innovative design with orthogonally biased ferrite or garnet cores for fast frequency tuning and liquid dielectric to adjust the frequency range and to control the core temperature. We describe mathematical and physical models of RF cavities suitable for FFAG and other applications as well as first measurements of candidate ferrite and dielectric materials. The first uses of the new cavity concept will be for improvements to the 8 GeV Fermilab Booster synchrotron.

43 PARTICLE ACCELERATORS↗

DIRECT OBSERVATIONS OF SUBMICROPULSE ELECTRON-BEAM EFFECTS FROM SHORT-RANGE WAKEFIELDS IN TESLA-TYPE SUPERCONDUCTING RF CAVITIES

Experiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then used a vertical corrector between the two cavities to steer the beam off axis at an angle into CC2. A Hamamatsu synchroscan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 4 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is 5 times l arger than the observed HOM-driven centroid oscillation within the macropulse, and it is consistent with a calculated short-range wakefield effect using ASTRA simulations.

43 PARTICLE ACCELERATORS↗

Non-RF Chain of Custody Item Monitor (CoCIM) Development Report

The Chain of Custody Item Monitor (CoCIM) developed by Sandia National Laboratories is one of the most mature and well-studied active seals for use in containment applications for arms control treaty verification and international nuclear safeguards. However, its typical design includes wireless communications provided by a radio frequency (RF) transmitter and receiver. While this provides flexibility of movement for many applications, it is unnecessary and undesired for some treaty verification applications. This report details the design and construction of two variants of the CoCIM that remove the RF transmission capability in favor of directly connected wired and short-range infrared communications, as well as a new coordinator that is used to interface the CoCIM to a computer, and new interface software that is simplified for a likely inspection use case.

42 ENGINEERING↗

Energy gain in a two-gap RF cavity

Velocity of a deeply non-relativistic particle can change during its acceleration inside an RF cavity significantly enough to cause a deviation of the energy gain from a linear model. This paper derives formulae for corrections to the energy gain in a two-gap RF cavity calculated by taking into account this velocity change in the next approximation. Then, the results are compared with direct particle tracking of an HWR cavity used at the PIP2IT test accelerator. The formulae significantly extend the range of parameters where analytical calculations work with a good accuracy. The approach is applied to two aspects of cavity phasing.

43 PARTICLE ACCELERATORS↗

NB film engineering with energetic condensation for tailored RF behavior

The different processes involved in energetic condensation are exploited in ECR (electron cyclotron resonance) generated plasma deposition and HiPIMS to tailor SRF film growth in sequential steps. The resulting Nb/Cu films display high quality material and show promise of high RF performance. The residual and flux induced surface resistance contributing factors are investigated with RF measurements at different temperatures and frequencies coupled with film material and superconducting properties characterization with various microscopy and magnetometry techniques. Results show that the manipulation of the interface, film nucleation and growth allows to tailor fundamental properties of the material to minimize surface resistance and field dependent losses.

Valente-Feliciano, Anne-Marie↗

Understanding the field and frequency dependence of rf loss in SRF cavities

SRF cavities subjected to heat treatment below 200 °C in the presence of nitrogen showed an improvement in quality factor while maintaining an accelerating gradient above 25 MV/m. Here, we report the rf performance of several single-cell superconducting radio frequency cavities with frequency ranging from 0.75 - 3.0 GHz subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 - 175 oC for 24 - 48 hours in low partial pressure of ultra-pure nitrogen gas. The improvement in Q? with Q-rise was observed when nitrogen gas was injected ~300 °C during the furnace treatment. The surface modification was confirmed by the change in electronic mean free path and near surface elemental analysis by SIMS. The field dependence of the rf losses is strongly correlated to the cavity frequency. The analysis of experimental data with available theoretical models as well as comparison with similar study on high temperature nitrogen doped cavities will be presented.

Ciovati, Gianluigi↗

GRIDDED RF GUN DESIGN FOR SRF LINAC APPLICATIONS

The thermionic gridded gun is described which gener-ates short electron bunches for further acceleration in a Nb3Sn conduction cooled SRF linac. The gun is built into the first cavity of the 250 keV injector [1] for the 20 kW, 10 MeV, 1.3 GHz CW conduction cooled one-cavity linac. The beam current is 2 mA. The RF gun design is presented as well as the results of perveance measure-ments, which are in a good agreement with the design parameters. The design of the RF resonator of the gun is presented also. The beam generated by the gun is matched to the injector to provide lack of current inter-ception in the SRF cavity.

Gonin, I.↗

High Linearity RF Circuits in CMOS Platforms (CRADA Final Report)

The goal of this CRADA was to understand high linearity silicon-on-insulator (SOI) radio frequency switches. The first direction investigated was high linearity RF mixers as these components are composed of a network of switches. During the course of the investigation, it was determined that while the SOI RF switches were effective in the application in mixers and produced state of the art performance, the use of SOI for mixers is not economically feasible because the technology only worked with advanced CMOS nodes <65nm which can have an NRE cost (from lithography masks) in excess of $\$$500,000.

42 ENGINEERING↗

Development of an FGPA-Based Cavity Simulator for Testing RF Controls

LLRF is used to precisely control the amplitude and phase of the RF field in cavities. Often times, access to test the control algorithms with RF equipment, especially in the presence of beam, is limited or beyond reach. In such cases, testing must be done through computer modeling or simulations. Computer modeling is often too slow and difficult to interface with the LLRF hardware. Analog or digital cavity simulators are preferred as they allow for interaction with the LLRF controls platform in real-time, and compared to their analog counterparts, FPGA-based digital cavity simulators allow for a more adjustable and sophisticated implementation. The newly developed FPGA-based cavity simulator includes the cavity electrical model, the cavity mechanical model including Lorentz Force Detuning and microphonics, an amplifier model which can simulate real amplifier nonlinearities, and a beam model. The simulator has been validated using measurements from BNL’s CeC 704 MHz 5-cell SRF cryomodule.

43 PARTICLE ACCELERATORS↗

Automated RF Phase Adjustment for Beam Stabilization in the Fermilab Linac

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally cor- rected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift correction, employing a prototype-based classification approach. Our model utilizes a 34-dimensional feature set (RF settings and BPM readings) and leverages a 7x27 response matrix for system modeling. To overcome limited real-world data, we generate synthetic data, enhancing model training and generalizability. Custom loss functions, including a sur- rogate energy-consistent loss and a temporal smoothness constraint, ensure physically plausible drift predictions. The goal is a robust system for autonomous phase adjustments, ensuring stable beam acceleration and reduced manual intervention.

Chichili, R. R. [U. Illinois, Chicago]↗

RHIC performance with 56 MHz RF and gold ion beams pre-cooled at lower energy

Presently there is an R&D ERL under construction at Collider-Accelerator Department (CAD) at BNL with its commissioning scheduled for FY09-10 [1]. The use of this full energy 21 MeV ERL in RHIC tunnel was recently proposed for a Proof-of-Principle demonstration of Coherent Electron Cooling of gold ions at 40 GeV/nucleon [2]. The purpose of this Note is to summarize numerical studies aimed at understanding the potential improvement of RHIC luminosity by using this R&D ERL for pre-cooling of Au ion beams with conventional electron cooling system at 40 GeV/nucleon. The constraints were such that electron beam parameters should be close to those expected from R&D ERL. Additionally, the cooling section in RHIC should not require major RHIC modification. As a result of these studies it was found that pre-cooling of gold ion at about 40 GeV/nucleon approximately doubles the average store luminosity of RHIC at top energy of 100 GeV/nucleon compared to the expected luminosity improvement with 56MHz RF upgrade [3, 4]. Significant luminosity improvement may be also gained on top of future expected luminosity performance with combined upgrades of 56MHz RF and all-plane stochastic cooling system with present beam parameters [5]. The electron beam parameters needed for such pre-cooling (see Table 1) are close to those expected from the R&D ERL which is presently under construction at BNL. With electron beam parameters from Table 1 it takes about 20 minutes to cool the transverse emittance of gold ions by a factor of two at 40 GeV/nucleon. Similar studies were done for protons as well. However, it was found that the electron beam parameters needed for pre-cooling of protons would require a significant upgrade of the present injector of the R&D ERL. Thus, discussion about protons is omitted from the present Note.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Buffer Chemical Polishing and RF Testing of the 56 MHz SRF Cavity

The 56 MHz cavity presents a unique challenge in preparing it for RF testing prior to construction of the cryomodule. This challenge arises due to the physical dimensions and subsequent weight of the cavity, and is further complicated by the coaxial geometry, and the need to properly chemically etch and high pressure rinse the entire inner surface prior to RF testing. To the best of my knowledge, this is the largest all niobium SRF cavity to be chemically etched and subsequently tested in a vertical dewar at 4K, and these processes will be the topic of this technical note.

43 PARTICLE ACCELERATORS↗

Linear Gain for the Microbunching Instability in an RF Compressor

Velocity (or rf) compression has been suggested as a technique for bunch compression complementary to the more established technique involving magnetic chicanes and represents an important research item being investigated at the SPARC test facility. One of the aspects of this technique still not sufficiently understood is its possible impact on the microbunching instability. The purpose of this report is to present the analytical framework for investigating this instability in rf compressors. We use methods similar to those successfully applied to magnetic compressors and derive some integral equations yielding the gain for the instability in linear approximation. The focus here is on the derivation of the relevant equations. Although examples of solutions to these equations are provided we defer a more comprehensive discussion of their implication to a future report. The present study is part of a larger effort for a more comprehensive investigation that eventually will include macroparticle simulations and experiments.

43 PARTICLE ACCELERATORS↗