At least 811 records · Page 45

Unbalanced Nested Random Effects Estimation of Variance Components

To investigate the contributing factors of variance in the measurement of an iodine 127 (127I) sample, we implement a nested random effects analysis of variance (ANOVA). Historically, the reported uncertainty on a measurement of 127I has been obtained by methods of forward uncertainty propagation because there is typically only one replicate of a given sample for which to estimate the uncertainty. When samples are processed there are several types of quality control (QC) standards analyzed along-side the unknown samples with two to five replicates for each. Assuming the variance observed in these replicate QC standards is representative of that of the unknown samples, we use these data in a nested random effects ANOVA to estimate the total uncertainty of a measurement. We demonstrate this approach with two sets of measurements from Idaho National Laboratory and compare the results with the forward uncertainty propagation approach. Variance component estimates for the coarsest level of the nesting structure were most imprecise because replicates were most limited at these levels. We find that the results largely agree between forward propagation and ANOVA, and the greatest contributors of variance are due to instrument variation and chemical processing, with human processing being among the smallest contributors. This analysis provides reassurance that the reported uncertainties using forward propagation are reasonable and the process is well controlled. We propose a future designed experiment to increase replicates at the coarsest level of the hierarchy to improve estimates of these variance components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Analysis of Radial and Random Microstructures of Mesophase Pitch Carbon Fibers

Carbon fibers (CF) with radial and random microstructures are produced. Here, these fibers are subjected to identical treatment before being mechanically tested and analyzed with Weibull analysis, with the results revealing a statistically significant difference in tensile strengths of 2.23 GPa for random CF and 1.69 GPa for radial CF. Raman mapping probed the crystalline structure perpendicular to the fiber axis and found a uniform structure, while wide‐angle X‐ray diffraction showed a significant difference of 7.5 Å in the crystallites’ basal lengths parallel to the fiber. Small‐angle X‐ray scattering is completed parallel to the fiber for the first time. A cross‐section Guinier plot of the 1D azimuthal integration is generated assuming symmetric scattering, and the parallel scatterers are found to have a similar length scale to the crystallite's length, validating the testing method. Finally, transmission electron microscopy is completed on the longitudinal cross‐section of each fiber. The radial carbon fiber is found to have a core–shell structure, as evidenced further by fast Fourier transform images. Through all studies, it is shown that the structure developed during mesophase pitch spinning altered the microstructure, thus impacting the mechanical properties, confirming a direct relationship between processing, structure, and properties.

Scherschel, Alexander [Univ. of Virginia, Charlott↗

Random Alloyed versus Intermetallic Nanoparticles: A Comparison of Electrocatalytic Performance

As synthetic methods advance for metal nanoparticles, more rigorous studies of structure–function relationships can be made. Many electrocatalytic processes depend on the size, shape, and composition of the nanocatalysts. Here, the properties and electrocatalytic behavior of random alloyed and intermetallic nanoparticles are compared. Beginning with an introduction of metallic nanoparticles for catalysis and the unique features of bimetallic compositions, the discussion transitions to case studies of nanoscale electrocatalysts where direct comparisons of alloy and intermetallic compositions are undertaken for methanol electrooxidation, formic acid electrooxidation, the oxygen reduction reaction, and the electroreduction of carbon dioxide (CO2). Design and synthesis strategies for random alloyed and intermetallic nanoparticles are discussed, with an emphasis on Pt–M and Cu–M compositions as model systems. The differences in catalytic performance between alloys and intermetallic nanoparticles are highlighted in order to provide an outlook for future electrocatalyst design.

36 MATERIALS SCIENCE↗

Random Polymerization Strategy Leads to a Family of Donor Polymers Enabling Well‐Controlled Morphology and Multiple Cases of High‐Performance Organic Solar Cells

Abstract Developing high‐performance donor polymers is important for nonfullerene organic solar cells (NF‐OSCs), as state‐of‐the‐art nonfullerene acceptors can only perform well if they are coupled with a matching donor with suitable energy levels. However, there are very limited choices of donor polymers for NF‐OSCs, and the most commonly used ones are polymers named PM6 and PM7, which suffer from several problems. First, the performance of these polymers (particularly PM7) relies on precise control of their molecular weights. Also, their optimal morphology is extremely sensitive to any structural modification. In this work, a family of donor polymers is developed based on a random polymerization strategy. These polymers can achieve well‐controlled morphology and high‐performance with a variety of chemical structures and molecular weights. The polymer donors are D–A1–D–A2‐type random copolymers in which the D and A1 units are monomers originating from PM6 or PM7, while the A2 unit comprises an electron‐deficient core flanked by two thiophene rings with branched alkyl chains. Consequently, multiple cases of highly efficient NF‐OSCs are achieved with efficiencies between 16.0% and 17.1%. As the electron‐deficient cores can be changed to many other structural units, the strategy can easily expand the choices of high‐performance donor polymers for NF‐OSCs.

Liang, Jiaen↗

A Facile Method to Fine‐Tune Polymer Aggregation Properties and Blend Morphology of Polymer Solar Cells Using Donor Polymers with Randomly Distributed Alkyl Chains

Abstract The device performance of polymer solar cells (PSCs) is strongly dependent on the blend morphology. One of the strategies for improving PSC performance is side‐chain engineering, which plays an important role in controlling the aggregation properties of the polymers and thus the domain crystallinity/purity of the donor–acceptor blends. In particular, for a family of high‐performance donor polymers with strong temperature‐dependent aggregation properties, the device performances are very sensitive to the size of alkyl chains, and the best device performance can only be achieved with an optimized odd‐numbered alkyl chain. However, the synthetic route of odd‐numbered alkyl chains is costly and complicated, which makes it difficult for large‐scale synthesis. Here, this study presents a facile method to optimize the aggregation properties and blend morphology by employing donor polymers with a mixture of two even‐numbered, randomly distributed alkyl chains. In a model polymer system, this study suggests that the structural and electronic properties of the random polymers comprising a mixture of 2‐octyldodecyl and 2‐decyltetradecyl alkyl chains can be systematically tuned by varying the mixing ratio, and a high power conversion efficiency (11.1%) can be achieved. This approach promotes the scalability of donor polymers and thus facilitates the commercialization of PSCs.

Yao, Huatong↗

Formation of Amorphous Carbon Multi‐Walled Nanotubes from Random Initial Configurations

Amorphous carbon nanotubes (a‐CNT) with up to four walls and sizes ranging from 200 to 3200 atoms have been simulated, starting from initial random configurations and using the Gaussian Approximation Potential. The important variables (like density, height, and diameter) required to successfully simulate a‐CNTs were predicted with the machine learning random forest technique. The width of the a‐CNT models ranged between 0.55–2 nm with an average inter‐wall spacing of 0.31 nm. The topological defects in a‐CNTs were analyzed and new defect configurations were observed. The electronic density of states and localization in these phases were discussed and delocalized electrons in the π subspace were identified as an important factor for inter‐layer cohesion. Spatial projection of the electronic conductivity favors axial transport along connecting hexagons, while non‐hexagonal parts of the network either hinder or bifurcate the electronic transport. A vibrational density of states was calculated and is potentially an experimentally comparable fingerprint of the material. The appearance of a low‐frequency radial breathing mode was discussed and the thermal conductivity at 300 K was estimated using the Green‐Kubo formula.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complex Langevin simulation of a random matrix model at nonzero chemical potential

In this study we test the complex Langevin algorithm for numerical simulations of a random matrix model of QCD with a first order phase transition to a phase of finite baryon density. We observe that a naive implementation of the algorithm leads to phase quenched results, which were also derived analytically in this article. We test several fixes for the convergence issues of the algorithm, in particular the method of gauge cooling, the shifted representation, the deformation technique and reweighted complex Langevin, but only the latter method reproduces the correct analytical results in the region where the quark mass is inside the domain of the eigenvalues. In order to shed more light on the issues of the methods we also apply them to a similar random matrix model with a milder sign problem and no phase transition, and in that case gauge cooling solves the convergence problems as was shown before in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AdS 3 gravity and random CFT

We compute the path integral of three-dimensional gravity with negative cosmological constant on spaces which are topologically a torus times an interval. These are Euclidean wormholes, which smoothly interpolate between two asymptotically Euclidean AdS 3 regions with torus boundary. From our results we obtain the spectral correlations between BTZ black hole microstates near threshold, as well as extract the spectral form factor at fixed momentum, which has linear growth in time with small fluctuations around it. The low-energy limit of these correlations is precisely that of a double-scaled random matrix ensemble with Virasoro symmetry. Our findings suggest that if pure three-dimensional gravity has a holographic dual, then the dual is an ensemble which generalizes random matrix theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pain in percutaneous liver core-needle biopsy: a randomized trial comparing the intercostal and subcostal approaches

Purpose: Effective pain control during and after percutaneous core needle liver biopsy is important with regard to ethical considerations and patient comfort. In this randomized double-blind study, we compared post-biopsy pain in the patients undergoing liver core-needle biopsy using either subcostal or intercostal approaches. Methods: All patients referred for ultrasound-guided CNLB between July 2017 and January 2018 to our interventional radiology department were randomized into two groups. Biopsy was performed through intercostal approach in the first group and through subcostal approach in the second group. The intensity of pain 0, 2, and 4 h after the procedure was compared in two groups using a 100-mm visual analogue scale. All biopsies were performed without procedural IV sedation. If patients’ discomfort demanded administration of IV analgesics during or after the procedure, then the patients were excluded from the study. Results: In patients without routine procedural IV sedation, there was no significant difference in the pain level between the intercostal and subcostal groups immediately after the procedure (p = 0.055), but we found a significant difference in the pain level between the two groups 2 (7.5 mm, p = 0.001) and 4 (2 mm, p = 0.001) h after the procedure. Conclusion: The minimum amount of change in the VAS score that is considered clinically important is 13 mm on a 100-mm scale. Pain differences at 2 and 4 h in the two groups in this study were statistically but not clinically significant. Therefore, the authors suggest the use of subcostal route for ultrasound-guided liver biopsy whenever possible, but the results do not warrant the routine use of post-procedure analgesics in whom biopsy is performed via intercostal route.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Randomized Comparison of Chemoembolization with Doxorubicin-Eluting Beads and Bland Embolization with BeadBlock for Hepatocellular Carcinoma

The purpose of this study was to evaluate the added role of a chemotherapeutic in transarterial chemoembolization (TACE) of intermediate-stage hepatocellular carcinoma (HCC). The issue is of major importance since, as suggested by recent evidence, hypoxia or incomplete devascularization of the tumor is a potent stimulator of angiogenesis, and there are not many papers supplying level one evidence confirming the value of a chemotherapeutic. The hypothesis was that since drug-eluting bead (DEB)-TACE is standardized and reproducible, a comparison with bland TACE can readily reveal the potential value of the chemotherapeutic. Two groups were randomized in this prospective study: group A (n = 41) was treated with doxorubicin DEB-TACE, and group B (n = 43) with bland embolization. Patients were randomized for tumor diameter. Patients were embolized at set time intervals (2 months), with a maximum of three embolizations. Tumor response was evaluated using the EASL criteria and {alpha}-fetoprotein levels. At 6 months a complete response was seen in 11 patients (26.8%) in the DEB-TACE group and in 6 patients (14%) in the bland embolization group; a partial response was achieved in 19 patients (46.3%) and 18 (41.9%) patients in the DEB-TACE and bland embolization groups, respectively. Recurrences at 9 and 12 months were higher for bland embolization (78.3% vs. 45.7%) at 12 months. Time to progression (TTP) was longer for the DEB-TACE group (42.4 {+-} 9.5 and 36.2 {+-} 9.0 weeks), at a statistically significant level (p = 0.008). In conclusion, DEB-TACE presents a better local response, fewer recurrences, and a longer TTP than bland embolization with BeadBlock. However, survival benefit and bland embolization with smaller particles must be addressed in future papers to better assess the clinical value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Angioplasty or Primary Stenting for Infrapopliteal Lesions: Results of a Prospective Randomized Trial

Excellent results with small stents in coronary arteries have led endovascular therapists to their use in infrapopliteal vessels. However, to date no level I evidence exists to recommend primary stenting over infrapopliteal angioplasty alone. The aim of this randomized single-center trial was to compare their 1-year outcome. A total of 38 limbs in 35 patients with critical limb ischemia were randomized to angioplasty (22 pts) or primary stenting (16 pts). Target lesions were infrapopliteal occluded (36) or stenotic (20) lesions ranging from <2 to >15 cm in length. The mean age was 72 years. At 12 months, there was no statistical difference in survival (angioplasty, 69.3%; primary stenting, 74.7%), in limb salvage (angioplasty, 90%; primary stenting, 91.7%), or in primary and secondary patency (angioplasty, 66 and 79.5%; primary stenting, 56 and 64%) between the groups Renal insufficiency was the only significant negative predicting factor for limb salvage in both groups. In conclusion, the 1-year results for both groups were broadly similar. Stenting has its place in infrapopliteal angioplasty if the procedure is jeopardized by a dissection or recoil, but our results do not support primary stenting in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of the Efficacy of the Embolic Agents Acrylamido Polyvinyl Alcohol Microspheres and Tris-Acryl Gelatin Microspheres for Uterine Artery Embolization for Leiomyomas: A Prospective Randomized Controlled Trial

Objective: To evaluate the efficacy of acrylamido polyvinyl alcohol microspheres (a-PVAM) as an embolic agent for uterine artery embolization (UAE) compared with Tris-acryl gelatin microspheres (TAGM).Design, Setting, ParticipantsProspective randomized double-blind noninferiority trial. Conducted at two sites both with regional UAE practices. Forty-six women with symptomatic leiomyomas.InterventionUAE procedure was performed with either of the two embolic agents. Either 700-900-{mu}m a-PVAM or 500-700-{mu}m TAGM was used.Main Outcome MeasuresChanges in leiomyoma perfusion, overall uterine volume, and dominant leiomyomas volume measured by contrast-enhanced magnetic resonance imaging at 1 week, 3 months, and 6 months after UAE by a reader blinded to the embolic agent used. Changes in Uterine Fibroid Symptoms and Quality of Life questionnaire scores were measured at 3, 6, and 12 months after UAE. Results: Forty-six patients were randomized and treated under the study protocol (a-PVAM n = 22, TAGM n = 24). There were no procedure-related complications. Two patients were excluded from analysis (one technical failure of the procedure, one withdrawal from study). Successful (>90%) leiomyoma devascularization was observed in 81% of subjects at 1 week after UAE, 97% at 3 months after UAE, and 95% at 6 months after UAE. No significant differences were observed in 14 of 15 outcome measurements, consistent with noninferiority. TAGM was slightly superior to a-PVAM on one comparison (overall quality of life at 3 months after UAE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of Two Different n-Butyl-2-Cyanoacrylates for the Embolization of Varicoceles: A Prospective, Randomized, Blinded Study

Purpose: This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles. Methods: A total of 112 insufficient spermatic veins (left-sided, n = 84; right-sided, n = 28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n = 54; Histoacryl, Braun, Germany) or NBCA-MS (n = 58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test. Results: Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n = 54/54, 100% vs. NBCA-MS, n = 54/57, 94.7%; P = 0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n = 45/54, 83.3% vs. NBCA-MS, n = 41/58, 70.7%; P = 0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n = 25/54, 46.3% vs. NBCA-MS, n = 29/58, 50%; P = 0.71). No glue-related complications were noted. Conclusions: NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutting-Balloon Angioplasty Versus Balloon Angioplasty as Treatment for Short Atherosclerotic Lesions in the Superficial Femoral Artery: Randomized Controlled Trial

Purpose: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial. Material and Methods: The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short ({<=}5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle-brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis. Results: In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 {+-} 0.11 versus 0.82 {+-} 0.12, respectively (p = 0.039), at 12 months. Conclusion: Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Comparison of Selective Internal Radiotherapy (SIRT) Versus Drug-Eluting Bead Transarterial Chemoembolization (DEB-TACE) for the Treatment of Hepatocellular Carcinoma

PurposeTo prospectively compare SIRT and DEB-TACE for treating hepatocellular carcinoma (HCC).MethodsFrom 04/2010–07/2012, 24 patients with histologically proven unresectable N0, M0 HCCs were randomized 1:1 to receive SIRT or DEB-TACE. SIRT could be repeated once in case of recurrence; while, TACE was repeated every 6 weeks until no viable tumor tissue was detected by MRI or contraindications prohibited further treatment. Patients were followed-up by MRI every 3 months; the final evaluation was 05/2013.ResultsBoth groups were comparable in demographics (SIRT: 8males/4females, mean age 72 ± 7 years; TACE: 10males/2females, mean age 71 ± 9 years), initial tumor load (1 patient ≥25 % in each group), and BCLC (Barcelona Clinic Liver Cancer) stage (SIRT: 12×B; TACE 1×A, 11×B). Median progression-free survival (PFS) was 180 days for SIRT versus 216 days for TACE patients (p = 0.6193) with a median TTP of 371 days versus 336 days, respectively (p = 0.5764). Median OS was 592 days for SIRT versus 788 days for TACE patients (p = 0.9271). Seven patients died in each group. Causes of death were liver failure (n = 4 SIRT group), tumor progression (n = 4 TACE group), cardiovascular events, and inconclusive (n = 1 in each group).ConclusionsNo significant differences were found in median PFS, OS, and TTP. The lower rate of tumor progression in the SIRT group was nullified by a greater incidence of liver failure. This pilot study is the first prospective randomized trial comparing SIRT and TACE for treating HCC, and results can be used for sample size calculations of future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging to Guide Thoracic Endovascular Aortic Repair (TEVAR): A Randomized Comparison of Two Methods, 2D/3D Versus 3D/3D Image Fusion

Purpose: To compare the accuracy of two-dimensional (2D) versus three-dimensional (3D) image fusion for thoracic endovascular aortic repair (TEVAR) image guidance. Materials and Methods: Between December 2016 and March 2018, all eligible patients who underwent TEVAR were prospectively included in a single-center study. Image fusion methods (2D/3D or 3D/3D) were randomly assigned to guide each TEVAR and compared in terms of accuracy, dose area product (DAP), volume of contrast medium injected, fluoroscopy time and procedure time. Results: Thirty-two patients were prospectively included; 18 underwent 2D/3D and 14 underwent 3D/3D TEVAR. The 3D/3D method allowed more accurate positioning of the aortic mask on top of the fluoroscopic images (proximal landing zone error vector: 1.7 ± 3.3 mm) than was achieved by the 2D/3D method (6.1 ± 6.1 mm; p = 0.03). The 3D/3D image fusion method was associated with significantly lower DAP than the 2D/3D method (50.5 ± 30.1 Gy cm{sup 2} for 3D/3D vs. 99.5 ± 79.1 Gy cm{sup 2} for 2D/3D; p = 0.03). The volume of contrast medium injected was significantly lower for the 3D/3D method than for the 2D/3D method (50.6 ± 22.9 ml vs. 98.4 ± 47.9 ml; p = 0.002). Conclusion: Higher image fusion accuracy and lower contrast volume and irradiation dose were observed for 3D/3D image fusion than for 2D/3D during TEVAR. Level of Evidence: II, Randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Randomized Freeway Stent Study: Drug-Eluting Balloons Outperform Standard Balloon Angioplasty for Postdilatation of Nitinol Stents in the SFA and PI Segment

Purpose: The prospective randomized multicenter Freeway study evaluated the possible hemodynamic and clinical benefits of primary stent insertion followed by percutaneous transluminal angioplasty (PTA) with drug-eluting balloons (DEB) over post-stent insertion PTA with standard balloons in the treatment of symptomatic femoropopliteal arteriosclerotic lesions. Methods: In total, 204 patients in 13 centers in Germany and Austria were enrolled and randomized to primary stenting followed by either FREEWAY™ drug-eluting balloon or standard PTA balloon angioplasty. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 6 months; the secondary endpoints include TLR rate at 12 months and primary patency, shift in Rutherford classification, ankle–brachial index (ABI) and major adverse events (MAE) at 6 and 12 months. Lesion characteristics and vessel patency were analyzed by an independent and blinded corelab. Results: At 6-month and 12-month follow-up, TLR rate was lower in the DEB arm compared to standard PTA but did not reach statistical significance (4.1% vs. 9.0% p = 0.234 and 7.9% vs. 17.7% p = 0.064, respectively). Primary patency was significantly better for patients treated with the DEB at 6 months (90.3% vs. 69.8% p = 0.001) and 12 months (77.4% vs. 61.0% p = 0.027). Improvement in Rutherford classifications was likewise significantly better for patients in the DEB group at 6 (94.9% vs. 84.3% p = 0.027) and 12 months (95.5% vs. 79.9% p = 0.003). The percentage of patients with an improved ABI of 1.0–1.2 was significantly higher in the DEB group compared to the PTA group at 6 months (55.3% vs. 35.3%; p = 0.015) but without significant difference at 12 months (48.2% vs. 32.9%; p = 0.055). At 6 months, rate of major adverse events (MAE) was 1% in both arms, and at 12 months 2.2% for the DEB and 3.8% for the PTA group. Conclusion: The Freeway Stent Study shows that the usage of DEB as a restenosis prophylaxis seems to be safe and feasible. The 12-month follow-up results give a clear sign in favor of the DEB group.

62 RADIOLOGY AND NUCLEAR MEDICINE↗