Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

Objective assessment of image quality and dose reduction in CT iterative reconstruction

Purpose: Iterative reconstruction (IR) algorithms have the potential to reduce radiation dose in CT diagnostic imaging. As these algorithms become available on the market, a standardizable method of quantifying the dose reduction that a particular IR method can achieve would be valuable. Such a method would assist manufacturers in making promotional claims about dose reduction, buyers in comparing different devices, physicists in independently validating the claims, and the United States Food and Drug Administration in regulating the labeling of CT devices. However, the nonlinear nature of commercially available IR algorithms poses challenges to objectively assessing image quality, a necessary step in establishing the amount of dose reduction that a given IR algorithm can achieve without compromising that image quality. This review paper seeks to consolidate information relevant to objectively assessing the quality of CT IR images, and thereby measuring the level of dose reduction that a given IR algorithm can achieve. Methods: The authors discuss task-based methods for assessing the quality of CT IR images and evaluating dose reduction. Results: The authors explain and review recent literature on signal detection and localization tasks in CT IR image quality assessment, the design of an appropriate phantom for these tasks, possible choices of observers (including human and model observers), and methods of evaluating observer performance. Conclusions: Standardizing the measurement of dose reduction is a problem of broad interest to the CT community and to public health. A necessary step in the process is the objective assessment of CT image quality, for which various task-based methods may be suitable. This paper attempts to consolidate recent literature that is relevant to the development and implementation of task-based methods for the assessment of CT IR image quality.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-01: A Fast Yet Sensitive EPID-Based Real-Time Treatment Verification System

Purpose: To create a real-time EPID-based treatment verification system which robustly detects treatment delivery and patient attenuation variations. Methods: Treatment plan DICOM files sent to the record-and-verify system are captured and utilized to predict EPID images for each planned control point using a modified GPU-based digitally reconstructed radiograph algorithm which accounts for the patient attenuation, source energy fluence, source size effects, and MLC attenuation. The DICOM and predicted images are utilized by our C++ treatment verification software which compares EPID acquired 1024×768 resolution frames acquired at ∼8.5hz from Varian Truebeam™ system. To maximize detection sensitivity, image comparisons determine (1) if radiation exists outside of the desired treatment field; (2) if radiation is lacking inside the treatment field; (3) if translations, rotations, and magnifications of the image are within tolerance. Acquisition was tested with known test fields and prior patient fields. Error detection was tested in real-time and utilizing images acquired during treatment with another system. Results: The computational time of the prediction algorithms, for a patient plan with 350 control points and 60×60×42cm^3 CT volume, is 2–3minutes on CPU and <27 seconds on GPU for 1024×768 images. The verification software requires a maximum of ∼9ms and ∼19ms for 512×384 and 1024×768 resolution images, respectively, to perform image analysis and dosimetric validations. Typical variations in geometric parameters between reference and the measured images are 0.32°for gantry rotation, 1.006 for scaling factor, and 0.67mm for translation. For excess out-of-field/missing in-field fluence, with masks extending 1mm (at isocenter) from the detected aperture edge, the average total in-field area missing EPID fluence was 1.5mm2 the out-of-field excess EPID fluence was 8mm^2, both below error tolerances. Conclusion: A real-time verification software, with EPID images prediction algorithm, was developed. The system is capable of performing verifications between frames acquisitions and identifying source(s) of any out-of-tolerance variations. This work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Chemical Composition Analysis for X-Ray Transport Container Scans

It is important for national security to control the movement of dangerous or strategically cargo such as explosives, radioactive materials, rare and precious metals. This control can be provided by scanning transport containers by gamma rays. In this report the existing technique for scanning (dual energy method) is considered and the alternative method based on measuring the energy distribution of gamma rays is proposed. For estimation perspectives of the proposing method, the corresponding simulation was conducted by using the GEANT4 toolkit. The example of the algorithm of reconstruction the chemical composition of the scanned object is also considered. In addition the experiment for estimation energy resolution of the detector based on a scintillation crystal BGO and SiPM was carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Primary track recovery in high-definition gas time projection chambers

Abstract We develop and validate a new algorithm called primary track recovery () that effectively deconvolves known physics and detector effects from nuclear recoil tracks in gas time projection chambers (TPCs) with high-resolution readout. This gives access to the primary track charge, length, and vector direction (helping to resolve the “head-tail” ambiguity). Additionally, provides a measurement of the transverse and longitudinal diffusion widths, which can be used to determine the absolute position of tracks in the drift direction for detector fiducialization. Using simulated helium recoils in an atmospheric pressure TPC with a 70:30 mixture of $$\hbox {He:CO}_2$$ He:CO 2 we compare the performance of to traditional methods for all key track variables. We find that the algorithm reduces reconstruction errors, including those caused by charge integration, for tracks with mean length-to-width ratios 1.4 and above, corresponding to recoil energies of 20 keV and above in the studied TPCs. We show that improves on existing methods for head-tail disambiguation, particularly for highly inclined tracks, and improves the determination of the absolute position of recoils on the drift axis via transverse diffusion. We find that can partially recover charge structure integrated out by the detector in the z direction, but that its determination of energy and length have worse resolution compared to existing methods. We use experimental data to qualitatively verify these findings and discuss implications for future directional detectors at the low-energy frontier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating Implementations of the Immersed Boundary Method in the Weather Research and Forecasting Model

The terrain-following coordinate system used by many atmospheric models can cause numerical instabilities due to discretization errors as resolved terrain slopes increase and the grid becomes highly skewed. The immersed boundary (IB) method, which does not require the grid to conform to the terrain, has been shown to alleviate these errors, and has been used successfully for high-resolution atmospheric simulations over steep terrain, including vertical building surfaces. Since many previous applications of IB methods to atmospheric models have used very fine grid resolution (5 m or less), the present study seeks to evaluate IB method performance over a range of grid resolutions and aspect ratios. Two classes of IB algorithms, velocity reconstruction and shear stress reconstruction, are tested within the common framework of the Weather Research and Forecasting (WRF) Model. Performance is evaluated in two test cases, one with flat terrain and the other with the topography of Askervein Hill, both under neutrally stratified conditions. WRF-IB results are compared to similarity theory, observations, and native WRF results. Despite sensitivity to the location at which the IB intersects the model grid, the velocity reconstruction IB method shows consistent performance when used with a hybrid RANS/LES surface scheme. The shear stress reconstruction IB method is not sensitive to the grid intersection, but is less consistent and near-surface velocity errors can occur at coarse resolutions. This study represents an initial investigation of IB method variability across grid resolutions in WRF. Future work will focus on improving IB method performance at intermediate to coarse resolutions.

54 ENVIRONMENTAL SCIENCES↗

Self-potential monitoring of a salt plume

Nonintrusively monitoring the spread of contaminants in real time with a geophysical method is an important task in hydrogeophysics. We have developed a sandbox experiment showing that the self-potential method can locate both the source of leakage and the front of a contaminant plume. We monitored the leakage of a plume of salty water from a hole at the bottom of a small tank located at the top of a main sandbox. Initially, the sand was saturated by tap water. At a given time, a hole was opened at the bottom of the tank, allowing the salty water to migrate by diffusion and buoyancy-driven flow in the main sandbox. The bottom of the sandbox contained a network of 32 nonpolarizing silver-silver chloride electrodes with amplifiers, connected to a multichannel voltmeter. The self-potential response associated withthe migration of the salt plume in the sandbox was recorded over time. A self-potential anomaly was observed with amplitude varying from a few millivolts at the start of the leak to a few tens of millivolts after a few minutes. The self-potential data were inverted using a time-lapse tomographic algorithm to reconstruct the position of the volumetric source current density over time. A positive volumetric source current density was associated with the position of the leak at the bottom of the leaking tank, whereas a negative volumetric source current density was associated with the salinity front moving down inside the sandbox. These poles were well reproduced by performing a finite-element simulation of the problem. Using this information, we estimated the speed of the salt plume sinking inside the sandbox. Therefore, the self-potential method can be used to track, in real time, the position of the front of a contaminant plume in a porous material.

54 ENVIRONMENTAL SCIENCES↗

Efficient compressive and Bayesian characterization of biphoton frequency spectra

Frequency-bin qudits constitute a promising tool for quantum information processing, but their high dimensionality can make for tedious characterization measurements. Here we introduce and compare compressive sensing and Bayesian mean estimation for recovering the spectral correlations of entangled photon pairs. Using a conventional compressive sensing algorithm, we reconstruct joint spectra with up to a 26-fold reduction in measurement time compared to the equivalent raster scan. Applying a custom Bayesian model to the same data, we then additionally realize reliable and consistent quantification of uncertainty. Finally, these efficient methods of biphoton characterization should advance our ability to use the high degree of parallelism and complexity afforded by frequency-bin encoding.

42 ENGINEERING↗

Space-Charge and Other Effects in Fermilab Booster and IOTA Rings’ Ionization Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At low beam intensities, initial velocities of the secondaries to collect (ions or electrons) result in the IPM profile smearing. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs, describe an effective algorithm to reconstruct the beam sizes from the measured IPM profiles and apply it to the Fermilab 8 GeV proton Booster and 70 MeV/c IOTA ring IPMs.

Shiltsev, Vladimir D.↗

Space-Charge Effects in Ionization Beam Profile Monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

Shiltsev, Vladimir D.↗

Proceedings of RIKEN BNL Research Center Workshop: The Definition of Jets in a Large Background

Jets, the collimated spray of particles produced by a high momentum quark or gluon, have been a key observable in high-energy particle and heavy ion physics. While in general, observables should be clearly defined with the same definition used in both theory and experiment, this has always been challenging for measurements of jets. Since the fragmentation of partons into final state hadrons is not calculable perturbatively and final state particles cannot be assigned unambiguously to particular partons, jet definitions rely on algorithms to reconstruct jets and select which particles are clustered into which jet. Defining a jet is particularly challenging when the jets are surrounded by particles from a high multiplicity underlying event such as those in heavy ion collisions, high luminosity proton-proton or electron-ion collisions. The community currently faces similar issues regarding jet definitions to those faced in particle physics in the preceding decades.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Solutions for Radiation Transport in Stochastic Media with Inhomogeneous Material Statistics

Accurately solving implicit Monte Carlo (IMC) thermal photon transport problems with mixed material cells is important in realistic applications. The production IMC package at LLNL treats mixed material cells arising from ALE remap and hydrodynamics using the same approximate model. The new Imp IMC thermal photon transport package currently under development has both a material interface reconstruction (MIR) algorithm and a Levermore-Pomraning (LP) stochastic medium algorithm for treating mixed material cells. Existing stochastic medium algorithms for treating mixed material cells in IMC lack a complete theoretical basis. The IMC LP algorithm implementation has been demonstrated to reproduce published deterministic LP solutions for the particular case of spatially homogeneous material statistics. Realistic simulations will include spatially inhomogeneous material statistics (material mean chord lengths). In a previous investigation, the LP-model for transport in binary stochastic media in rod geometry was generalized to accommodate spatially varying material chord lengths, i.e., the mixing statistics were allowed to be nonhomogeneous. Analytical solutions were obtained and used to produce a verifi cation suite for the Imp IMC Levermore-Pomraning implementation for different spatial variations of the chord lengths. However, the accuracy of the LP model when the mixing statistics are nonhomogeneous has not been assessed and leaves open the question of whether local accuracy is improved or further degraded when chord lengths are not uniform. This shortcoming is rectifi ed here by developing benchmark analytic solutions for transport in binary Markovian stochastic mixtures in rod geometry with nonhomogeneous mixing statistics, using spatially varying chord lengths considered in the previous investigation based on the LP model. Methods for sampling a nonhomogeneous Poisson process (NHPP) are first described and used to construct individual realizations of the binary mixtures in rod geometry. Analytic solutions are then obtained for the forward and backward directed fluxes on a given realization, now viewed as a deterministic medium with alternating layers of the two materials with known interface locations. Finally, material averaged scalar fluxes are obtained using these sampling schemes with spatially linear and quadratic chord lengths and used to assess the accuracy of the previously obtained LP-model results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

Fine Structure in 3C 120 and 3C 84

Seven epochs of very long baseline radio interferometric observations of the Seyfert galaxies 3C 120 and 3C 84, at 3.8-cm wave length using stations at Westford, Massachusetts, Goldstone, California, Green Bank, West Virginia, and Onsala, Sweden, have been analyzed for source structure. An algorithm for reconstructing the brightness distribution of a spatially confined source from fringe amplitude and so called closure phase data has been developed and successfully applied to artificially generated test data and to data on the above mentioned sources. Over the two year time period of observation, 3C 120 was observed to consist of a double source showing apparent super relativistic expansion and separation velocities. The total flux changes comprising one outburst can be attributed to one of these components. 3C 84 showed much slower changes, evidently involving flux density changes in individual stationary components rather than relative motion.

Hutton, L. K.↗

Methods of using closure phases in radio aperture synthesis

A simple iterative algorithm for reconstructing the images of compact radio sources from very-long-baseline interferometry (VLBI) measurements of visibility amplitudes and 'closure' phases is described. The method makes efficient use of redundant sampling of spatial frequencies by making a global solution of phase 'closure' equations for a complete set of observations.

Rogers, A. E. E.↗

Pneumatic distortion compensation for aircraft surface pressure sensing devices

In this paper a technique of compensating for pneumatic distortion in aircraft surface pressure sensing devices is developed. The compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Typically, most of the distortion occurs within the pneumatic tubing used to transmit pressure impulses from the surface of the aircraft to the measurement transducer. This paper develops a second-order distortion model that accurately describes the behavior of the primary wave harmonic of the pneumatic tubing. The model is expressed in state-variable form and is coupled with standard results from minimum-variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data. Covariance selection and filter-tuning examples are presented. Results presented verify that, given appropriate covariance magnitudes, the algorithms accurately reconstruct surface pressure values from remotely sensed pressure measurements.

Whitmore, Stephen A.↗

Colliding Winds and Tomography of O-Type Binaries

This grant was awarded in support of an observational study with the NASA IUE Observatory during the 15th episode (1992), and it subsequently also supported our continuing work in 16th (1994) and 18th (1995) episodes. The project involved the study of FUV spectra of massive spectroscopic binary systems containing hot stars of spectral type O. We applied a Doppler tomography algorithm to reconstruct the individual component UV spectra of stars in order to obtain improved estimates of the temperature, gravity, UV intensity ratio, and projected rotational velocity for stars in each system, and to make a preliminary survey for abundance anomalies through comparison with standard spectra. We also investigated the orbital phase-related variations in the UV stellar wind lines to probe the geometries of wind-wind collisions in these systems. The project directly supported two Ph.D. dissertations at Georgia State University (by Penny and Thaller), and we are grateful for this support. No inventions were made in the performance of this work. Detailed results are summarized in the abstracts listed in the following section.

Gies, Dougles R.↗

Spatial Modulation Improves Performance in CTIS

Suitably formulated spatial modulation of a scene imaged by a computed-tomography imaging spectrometer (CTIS) has been found to be useful as a means of improving the imaging performance of the CTIS. As used here, "spatial modulation" signifies the imposition of additional, artificial structure on a scene from within the CTIS optics. The basic principles of a CTIS were described in "Improvements in Computed- Tomography Imaging Spectrometry" (NPO-20561) NASA Tech Briefs, Vol. 24, No. 12 (December 2000), page 38 and "All-Reflective Computed-Tomography Imaging Spectrometers" (NPO-20836), NASA Tech Briefs, Vol. 26, No. 11 (November 2002), page 7a. To recapitulate: A CTIS offers capabilities for imaging a scene with spatial, spectral, and temporal resolution. The spectral disperser in a CTIS is a two-dimensional diffraction grating. It is positioned between two relay lenses (or on one of two relay mirrors) in a video imaging system. If the disperser were removed, the system would produce ordinary images of the scene in its field of view. In the presence of the grating, the image on the focal plane of the system contains both spectral and spatial information because the multiple diffraction orders of the grating give rise to multiple, spectrally dispersed images of the scene. By use of algorithms adapted from computed tomography, the image on the focal plane can be processed into an image cube a three-dimensional collection of data on the image intensity as a function of the two spatial dimensions (x and y) in the scene and of wavelength (lambda). Thus, both spectrally and spatially resolved information on the scene at a given instant of time can be obtained, without scanning, from a single snapshot; this is what makes the CTIS such a potentially powerful tool for spatially, spectrally, and temporally resolved imaging. A CTIS performs poorly in imaging some types of scenes in particular, scenes that contain little spatial or spectral variation. The computed spectra of such scenes tend to approximate correct values to within acceptably small errors near the edges of the field of view but to be poor approximations away from the edges. The additional structure imposed on a scene according to the present method enables the CTIS algorithms to reconstruct acceptable approximations of the spectral data throughout the scene.

Bearman, Gregory H.↗