Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Target Characterization and Follow-Up Observations in Support of the Kepler Mission

A variety of experiments were carried out to investigate the number and characteristics of the stars to be included in the Kepler Input Catalog. One result of this work was the proposal that the 2MASS Catalog of astrometry and photometry in the infrared be used as the primary source for the initial selection of candidate target stars, because this would naturally decrease the number of unsuitable hot blue stars and would also increase the number of desirable solar-type dwarf stars. Another advantage of the 2MASS catalogue is that the stellar positions have more than adequate astrometric accuracy for the Kepler target selection. The original plan reported in the Concept Study Report was to use the parallaxes and multi-band photometry from the FAME mission to provide the information needed for reliable separation of giants and dwarfs. As a result of NASA's withdrawal of support for FAME an alternate approach was needed. In November 2002 we proposed to the Kepler Science Team that a ground-based multi-band photometric survey could help alleviate the loss of the FAME data. The Science Team supported this proposal strongly, and we undertook a survey of possible facilities for such a survey. We concluded that the SAO's 4Shooter CCD camera on the 1.2-m telescope at the Whipple Observatory on Mount Hopkins, Arizona, showed promise for this work.

Latham, David W.↗

Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

semiconductor lasers↗

A Discussion of Oxygen Recovery Definitions and Key Performance Parameters for Closed-Loop Atmosphere Revitalization Life Support Technology Development

Over the last 55 years, NASA has evolved life support for crewed space exploration vehicles from simple resupply during Project Mercury to the complex and highly integrated system of systems aboard the International Space Station. As NASA targets exploration destinations farther from low Earth orbit and mission durations of 500 to 1000 days, life support systems must evolve to meet new requirements. In addition to having more robust, reliable, and maintainable hardware, limiting resupply becomes critical for managing mission logistics and cost. Supplying a crew with the basics of food, water, and oxygen become more challenging as the destination ventures further from Earth. Aboard ISS the Atmosphere Revitalization Subsystem (ARS) supplies the crew's oxygen demand by electrolyzing water. This approach makes water a primary logistics commodity that must be managed carefully. Chemical reduction of metabolic carbon dioxide (CO2) provides a method of recycling oxygen thereby reducing the net ARS water demand and therefore minimizing logistics needs. Multiple methods have been proposed to achieve this recovery and have been reported in the literature. However, depending on the architecture and the technology approach, "oxygen recovery" can be defined in various ways. This discontinuity makes it difficult to compare technologies directly. In an effort to clarify community discussions of Oxygen Recovery, we propose specific definitions and describe the methodology used to arrive at those definitions. Additionally, we discuss key performance parameters for Oxygen Recovery technology development including challenges with comparisons to state-of-the-art.

Abney, Morgan B.↗

Methane Trace-Gas Sensing Enabled by Silicon Photonic Integration

Fugitive methane leaks occurring during extraction at typical natural gas wells have an adverse environmental impact due to the methane’s large radiative forcing, in addition to reducing the producer’s overall efficiency and cost. Mitigation of these concerns can benefit from cost-effective sensor nodes, performing reliable, rapid and continuous tracking of methane emissions. The efficacy of laser spectroscopy has been widely demonstrated in both environmental and medical applications due to its sensitivity and specificity to the target analyte. However, the present cost and lack of manufacturing scalability of traditional free-space optical systems can limit their viability for deployment in economical wide-area sensor networks. This presentation will review the development and performance of a cost-effective silicon photonic trace gas sensing platform that leverages silicon photonic waveguide and packaging technologies to perform on-chip evanescent field spectroscopy of methane.

03 NATURAL GAS↗

Increased Plutonium-238 Production via High Flux Isotope Reactor Permanent Beryllium Reflector Redesign

Irradiation of 237Np-bearing targets in the permanent beryllium reflector (PBR) of Oak Ridge National Laboratory’s (ORNL) High Flux Isotope Reactor (HFIR) results in high-purity 238Pu that can be used as a reliable power source for deep space and planetary National Aeronautics and Space Administration missions. However, HFIR’s 238Pu production capability is constrained by the available irradiation volume in its PBR. In preparation for the HFIR beryllium change-out in 2023, ORNL staff have redesigned the PBR to include six additional irradiation sites, be more versatile with respect to irradiation and scattering experiments, and enhance its thermal-structural performance. The new PBR design offers large potential increases in annual 238Pu production at ORNL.

Chandler, David↗

Assessment of fission product yields data needs in nuclear reactor applications

Studies on the build-up of fission products in fast reactors have been performed, with particular emphasis on the effects related to the physics of the nuclear fission process. Fission product yields, which are required for burn-up calculations, depend on the proton and neutron number of the target nucleus as well as on the incident neutron energy. Evaluated nuclear data on fission product yields are available for all relevant target nuclides in reactor applications. However, the description of their energy dependence in evaluated data is still rather rudimentary, which is due to the lack of experimental fast fission data and reliable physical models. Additionally, physics studies of evaluated JEFF-3.1.1 fission yields data have shown potential improvements, especially for various fast fission data sets of this evaluation. In recent years, important progress in the understanding of the fission process has been made, and advanced model codes are currently being developed. This paper deals with the semi-empirical approach to the description of the fission process, which is used in the GEF code being developed by K.-H. Schmidt and B. Jurado on behalf of the OECD Nuclear Energy Agency, and with results from the corresponding author's diploma thesis. An extended version of the GEF code, supporting the calculation of spectrum weighted fission product yields, has been developed. It has been applied to the calculation of fission product yields in the fission rate spectra of a MOX fuelled sodium-cooled fast reactor. Important results are compared to JEFF-3.1.1 data and discussed in this paper. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High heat flux Langmuir probe array for the DIII-D divertor plates

Two modular arrays of Langmuir probes designed to handle a heat flux of up to 25 MW/m{sup 2} for 10 s exposures have been installed in the lower divertor target plates of the DIII-D tokamak. The 20 pyrolytic graphite probe tips have more than three times higher thermal conductivity and 16 times larger mass than the original DIII-D isotropic graphite probes. The probe tips have a fixed 12.5 deg. surface angle to distribute the heat flux more uniformly than the previous 6 mm diameter domed collectors and a symmetric 'rooftop' design to allow operation with reversed toroidal magnetic field. A large spring-loaded contact area improves heat conduction from each probe tip through a ceramic insulator into a cooled graphite divertor floor tile. The probe tips, brazed to molybdenum foil to ensure good electrical contact, are mounted in a ceramic tray for electrical isolation and reliable cable connections. The new probes are located 1.5 cm radially apart in a staggered arrangement near the entrance to the lower divertor pumping baffle and are linearly spaced 3 cm apart on the shelf above the in-vessel cryopump. Typical target plate profiles of J{sub sat}, T{sub e}, and V{sub f} with 4 mm spatial resolution are shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliable vision-guided grasping

Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems, such as tracking, in that the distance from the target is a relevant servo parameter. The methodology described in this paper is hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent,' and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

Nicewarner, Keith E.↗

Target Station Design for the Mu2e Experiment

The Mu2e experiment at Fermilab is devoted to search for the conversion of a negative muon into an electron in the field of a nucleus without emission of neutrinos. One of the main parts of the Mu2e experimental setup is its Target Station in which negative pions are generated in interactions of the 8-GeV primary proton beam with a tungsten target. A large-aperture 5-T superconducting production solenoid (PS) enhances pion collection, and an S-shaped transport solenoid (TS) delivers muons and pions to the Mu2e detector. The heat and radiation shield (HRS) protects the PS and the first TS coils. A beam dump absorbs the spent beam. In order for the PS superconducting magnet to operate reliably the sophisticated HRS was designed and optimized for performance and cost. The beam dump was designed to absorb the spent beam and maintaining its temperature and air activation in the hall at the allowable level. Comprehensive MARS15 simulations have been carried out to optimize all the parts while maximizing muon yield. Results of simulations of critical radiation quantities and their implications on the overall Target Station design and integration will be reported.

43 PARTICLE ACCELERATORS↗

Computer Modeling and Simulation: Increasing Reliability by Disentangling Verification and Validation

Verification and validation (V&V) of computer codes and models used in simulations are two aspects of the scientific practice of high importance that recently have been discussed widely by philosophers of science. While verification is predominantly associated with the correctness of the way a model is represented by a computer code or algorithm, validation more often refers to the model’s relation to the real world and its intended use. Because complex simulations are generally opaque to a practitioner, the Duhem problem can arise with verification and validation due to their entanglement; such an entanglement makes it impossible to distinguish whether a coding error or the model’s general inadequacy to its target should be blamed in the case of a failure. I argue that a clear distinction between computer modeling and simulation has to be made to disentangle verification and validation. Drawing on that distinction, I suggest to associate modeling with verification and simulation, which shares common epistemic strategies with experimentation, with validation. To explain the reasons for their entanglement in practice, I propose a Weberian ideal–typical model of modeling and simulation as roles in practice. I examine an approach to mitigate the Duhem problem for verification and validation that is generally applicable in practice and is based on differences in epistemic strategies and scopes. Based on this analysis, I suggest two strategies to increase the reliability of simulation results, namely, avoiding alterations of verified models at the validation stage as well as performing simulations of the same target system using two or more different models. In response to Winsberg’s claim that verification and validation are entangled I argue that deploying the methodology proposed in this work it is possible to mitigate inseparability of V&V in many if not all domains where modeling and simulation are used.

97 MATHEMATICS AND COMPUTING↗

Reliable vision-guided grasping

Automated assembly of truss structures in space requires vision-guided servoing for grasping a strut when its position and orientation are uncertain. This paper presents a methodology for efficient and robust vision-guided robot grasping alignment. The vision-guided grasping problem is related to vision-guided 'docking' problems. It differs from other hand-in-eye visual servoing problems such as tracking in that the distance from the target is a relevant servo parameter. The methodology described in this paper is a hierarchy of levels in which the vision/robot interface is decreasingly 'intelligent', and increasingly fast. Speed is achieved primarily by information reduction. This reduction exploits the use of region-of-interest windows in the image plane and feature motion prediction. These reductions invariably require stringent assumptions about the image. Therefore, at a higher level, these assumptions are verified using slower, more reliable methods. This hierarchy provides for robust error recovery in that when a lower-level routine fails, the next-higher routine will be called and so on. A working system is described which visually aligns a robot to grasp a cylindrical strut. The system uses a single camera mounted on the end effector of a robot and requires only crude calibration parameters. The grasping procedure is fast and reliable, with a multi-level error recovery system.

Nicewarner, Keith E.↗

Visible - Near Infrared Spectral Indices for Mapping Mineralogy and Chemistry with OSIRIS-REx

The primary objective of the Origins, Spectral Interpretation, Resource Identification, SecurityRegolith Explorer (OSIRIS-REx) mission is to return to Earth a pristine sample of carbonaceous material from the primitive asteroid (101955) Bennu. To support compositional mapping as part of sample site selection and characterization, we tested 95 spectral parameters on visible to near infrared laboratory reflectance data of minerals and carbonaceous meteorites to find which of these parameters reliably identified spectral features of interest. Most spectral parameters had high positive detection rates when used on spectra of pure, single component materials. The meteorite spectra have fewer and weaker absorption features and, as a result, fewer detections with the spectral parameters. Parameters targeting absorptions at 0.7 and 2.7 – 3 µm, which arise due to hydrated minerals, were most successful for the meteorites. Based on these results, we have identified a set of 17 parameters that are most likely to be useful at Bennu and spectral analogs. These parameters detect olivines, pyroxenes, carbonates, water/OH-bearing minerals, serpentines, ferric minerals, and organics. Particle size and albedo are known to affect band depth but had a negligible impact on parameter accuracy. The effect of instrument-like noise added to the laboratory spectra can result in more false positive detections, but these exhibit large errors. Our study has determined the prioritization of spectral parameters used for OSIRISREx spectral analysis and mapping and informs the reliability of all parameter-derived data products.

Hannah H Kaplan↗

Kepler-22b: A 2.4 EARTH-RADIUS PLANET IN THE HABITABLE ZONE OF A SUN-LIKE STAR

A search of the time-series photometry from NASA's Kepler spacecraft reveals a transiting planet candidate orbiting the 11th magnitude G5 dwarf KIC 10593626 with a period of 290 days. The characteristics of the host star are well constrained by high-resolution spectroscopy combined with an asteroseismic analysis of the Kepler photometry, leading to an estimated mass and radius of 0.970 {+-} 0.060 M{sub Sun} and 0.979 {+-} 0.020 R{sub Sun }. The depth of 492 {+-} 10 ppm for the three observed transits yields a radius of 2.38 {+-} 0.13 Re for the planet. The system passes a battery of tests for false positives, including reconnaissance spectroscopy, high-resolution imaging, and centroid motion. A full BLENDER analysis provides further validation of the planet interpretation by showing that contamination of the target by an eclipsing system would rarely mimic the observed shape of the transits. The final validation of the planet is provided by 16 radial velocities (RVs) obtained with the High Resolution Echelle Spectrometer on Keck I over a one-year span. Although the velocities do not lead to a reliable orbit and mass determination, they are able to constrain the mass to a 3{sigma} upper limit of 124 M{sub Circled-Plus }, safely in the regime of planetary masses, thus earning the designation Kepler-22b. The radiative equilibrium temperature is 262 K for a planet in Kepler-22b's orbit. Although there is no evidence that Kepler-22b is a rocky planet, it is the first confirmed planet with a measured radius to orbit in the habitable zone of any star other than the Sun.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstruction of implanted marker trajectories from cone-beam CT projection images using interdimensional correlation modeling

Purpose: Cone-beam CT (CBCT) is a widely used imaging modality for image-guided radiotherapy. Most vendors provide CBCT systems that are mounted on a linac gantry. Thus, CBCT can be used to estimate the actual 3-dimensional (3D) position of moving respiratory targets in the thoracic/abdominal region using 2D projection images. The authors have developed a method for estimating the 3D trajectory of respiratory-induced target motion from CBCT projection images using interdimensional correlation modeling. Methods: Because the superior–inferior (SI) motion of a target can be easily analyzed on projection images of a gantry-mounted CBCT system, the authors investigated the interdimensional correlation of the SI motion with left–right and anterior–posterior (AP) movements while the gantry is rotating. A simple linear model and a state-augmented model were implemented and applied to the interdimensional correlation analysis, and their performance was compared. The parameters of the interdimensional correlation models were determined by least-square estimation of the 2D error between the actual and estimated projected target position. The method was validated using 160 3D tumor trajectories from 46 thoracic/abdominal cancer patients obtained during CyberKnife treatment. The authors’ simulations assumed two application scenarios: (1) retrospective estimation for the purpose of moving tumor setup used just after volumetric matching with CBCT; and (2) on-the-fly estimation for the purpose of real-time target position estimation during gating or tracking delivery, either for full-rotation volumetric-modulated arc therapy (VMAT) in 60 s or a stationary six-field intensity-modulated radiation therapy (IMRT) with a beam delivery time of 20 s. Results: For the retrospective CBCT simulations, the mean 3D root-mean-square error (RMSE) for all 4893 trajectory segments was 0.41 mm (simple linear model) and 0.35 mm (state-augmented model). In the on-the-fly simulations, prior projections over more than 60° appear to be necessary for reliable estimations. The mean 3D RMSE during beam delivery after the simple linear model had established with a prior 90° projection data was 0.42 mm for VMAT and 0.45 mm for IMRT. Conclusions: The proposed method does not require any internal/external correlation or statistical modeling to estimate the target trajectory and can be used for both retrospective image-guided radiotherapy with CBCT projection images and real-time target position monitoring for respiratory gating or tracking.

60 APPLIED LIFE SCIENCES↗

Visible-near Infrared Spectral Indices for Mapping Mineralogy and Chemistry with OSIRIS-Rex

The primary objective of the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission is to return to Eartha pristine sample of carbonaceous material from the primitive asteroid (101955) Bennu. To support compositional mapping of Bennu as part of sample site selection and characterization, we tested 95 spectral indices on visible to near infrared laboratory reflectance data from minerals and carbonaceous meteorites. Our aim was to determine which indices reliably identify spectral features of interest. Most spectral indices had high positive detection rates when applied to spectra of pure, single-component materials. The meteorite spectra have fewer and weaker absorption features and, as a result, fewer detections with the spectral indices. Indices targeting absorptions at 0.7 and 2.7–3lm, which are attributable to hydrated minerals, were most successful for the meteorites. Based on these results, we identified a set of 17 indices that are most likely to be useful at Bennu. These indices detect olivines, pyroxenes, carbonates, water/OH-bearing minerals, serpentines, ferric minerals, and organics. Particle size and albedo are known to affect band depth but had a negligible impact on interpretive success with spectral indices. Preliminary analysis of the disk-integrated Bennu spectrum with these indices is consistent with expectations given the observed absorption near 3lm. Our study prioritizes spectral indices to be used for OSIRIS-REx spectral analysis and mapping and informs the reliability of all index-derived data products, including a science value map for sample site selection.

Hannah H. Kaplan↗

Visible–near infrared spectral indices for mapping mineralogy and chemistry with OSIRIS-REx

The primary objective of the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission is to return to Earth a pristine sample of carbonaceous material from the primitive asteroid (101955) Bennu. To support compositional mapping of Bennu as part of sample site selection and characterization, we tested 95 spectral indices on visible to near infrared laboratory reflectance data from minerals and carbonaceous meteorites. Our aim was to determine which indices reliably identify spectral features of interest. Most spectral indices had high positive detection rates when applied to spectra of pure, single-component materials. The meteorite spectra have fewer and weaker absorption features and, as a result, fewer detections with the spectral indices. Indices targeting absorptions at 0.7 and 2.7–3 µm, which are attributable to hydrated minerals, were most successful for the meteorites. Based on these results, we identified a set of 17 indices that are most likely to be useful at Bennu. These indices detect olivines, pyroxenes, carbonates, water/OH-bearing minerals, serpentines, ferric minerals, and organics. Particle size and albedo are known to affect band depth but had a negligible impact on interpretive success with spectral indices. Preliminary analysis of the disk-integrated Bennu spectrum with these indices is consistent with expectations given the observed absorption near 3 lm. Our study prioritizes spectral indices to be used for OSIRIS-REx spectral analysis and mapping and informs the reliability of all index-derived data products, including a science value map for sample site selection.

Hannah H. Kaplan↗

Single-shot divergence measurements of a laser-generated relativistic electron beam

The relativistic electron transport induced by an ultraintense picosecond laser is experimentally investigated using an x-ray two-dimensional imaging system. Previous studies of the electron beam divergence [R. B. Stephens et al. Phys. Rev. E 69, 066414 (2004), for instance] were based on an x-ray imaging of a fluorescence layer buried at different depths in the target along the propagation axis. This technique required several shots to be able to deduce the divergence of the beam. Other experiments produced single-shot images in a one-dimensional geometry. The present paper describes a new target design producing a single-shot, two-dimensional image of the electrons propagating in the target. Several characteristics of the electron beam are extracted and discussed and Monte Carlo simulations provide a good understanding of the observed beam shape. The proposed design has proven to be efficient, reliable, and promising for further similar studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗