Search NASA⌕ Search

SEARCH · Search NASA

Results for “Return Period”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Optical fiber sensors for damage analysis in aerospace materials

Under this grant, fiber optic sensors were investigated for use in the nondestructive evaluation of aging aircraft. Specifically, optical fiber sensors for detection and location of impacts on a surface, and for detection of corrosion in metals were developed. The use of neural networks was investigated for determining impact location by processing the output of a network of fiberoptic strain sensors distributed on a surface. This approach employs triangulation to determine location by comparing the arrival times at several sensors, of the acoustic signal generated by the impact. For this study, a neural network simulator running on a personal computer was used to train a network using a back-propagation algorithm. Fiber optic extrinsic Fabry-Perot interferometer (EFPI) strain sensors are attached to or embedded in the surface, so that stress waves emanating from an impact can be detected. The ability of the network to determine impact location by time-or-arrival of acoustic signals was assessed by comparing network outputs with actual experimental results using impacts on a panel instrumented with optical fiber sensors. Using the neural network to process the sensor outputs, the impact location can be inferred to centimeter range accuracy directly from the arrival time data. In addition, the network can be trained to determine impact location, regardless of material anisotropy. Results demonstrate that a back-propagation network identifies impact location for an anisotropic graphite/bismaleimide plate with the same accuracy as that for an isotropic aluminum plate. Two different approaches were investigated for the development of fiber optic sensors for corrosion detection in metals, both utilizing optical fiber sensors with metal coatings. In the first approach, an extrinsic Fabry-Perot interferometric fiber optic strain sensor was placed under tensile stress, and while in the resulting strained position, a thick coating of metal was applied. Due to an increase in the quantity of material, the sensor does not return to its original position upon removal of the applied stress, and some residual strain is maintained within the sensor element. As the metal thickness decreases due to corrosion, this strain is released, providing the sensing mechanism for corrosion detection. In the second approach, photosensitive optical fibers with long period Bragg gratings in the core were coated with metal. The Bragg gratings serve to couple core modes at discrete wavelengths to cladding modes. Since cladding modes interact with the metal coating surrounding the fiber cladding, the specific wavelengths coupled from core to cladding depend on the refractive index of the metal coating. Therefore, as the metal corrodes, the resulting change in index of the coating may be measured by measuring the change in wavelength of the coupled mode. Results demonstrate that both approaches can be successfully used to track the loss in metal coating on the optical fiber sensors due to corrosion.

Schindler, Paul↗

On the existence of debris clouds in the Space Station orbit: Final results of the EuroMir 1995 impact detector

A flight experiment flown onboard the Mir space station as a part of the Euromir 95 mission is considered. The aim of the experiment was to develop a greater understanding of the effects of the space environment on materials. In addition to the active enumeration of particle impacts and trajectories, the aim was to capture hypervelocity particles for their return to earth. Postflight measurements were performed to determine the flux density, diameters and subsequent effects on various optical thermal control and structural materials. Sensors actively measured the atomic oxygen flux, the contamination depostion and their effects during the mission. Two clouds of small particles were detected during a period of 100 days onboard Mir. It is concluded that the measured momenta of these particles suggests that their size and velocity are such that they cause damage to optics and thermal control surfaces.

Maag, Carl R.↗

Magnetic Dipole Inflation with Cascaded ARC and Applications to Mini-Magnetospheric Plasma Propulsion

Mini-Magnetospheric Plasma Propulsion (M2P2) seeks to create a plasma-inflated magnetic bubble capable of intercepting significant thrust from the solar wind for the purposes of high speed, high efficiency spacecraft propulsion. Previous laboratory experiments into the M2P2 concept have primarily used helicon plasma sources to inflate the dipole magnetic field. The work presented here uses an alternative plasma source, the cascaded arc, in a geometry similar to that used in previous helicon experiments. Time resolved measurements of the equatorial plasma density have been conducted and the results are discussed. The equatorial plasma density transitions from an initially asymmetric configuration early in the shot to a quasisymmetric configuration during plasma production, and then returns to an asymmetric configuration when the source is shut off. The exact reasons for these changes in configuration are unknown, but convection of the loaded flux tube is suspected. The diffusion time was found to be an order of magnitude longer than the Bohm diffusion time for the period of time after the plasma source was shut off. The data collected indicate the plasma has an electron temperature of approximately 11 eV, an order of magnitude hotter than plasmas generated by cascaded arcs operating under different conditions. In addition, indirect evidence suggests that the plasma has a beta of order unity in the source region.

Giersch, L.↗

Horizontal vestibuloocular reflex evoked by high-acceleration rotations in the squirrel monkey. II. Responses after canal plugging

The horizontal angular vestibuloocular reflex (VOR) evoked by high-frequency, high-acceleration rotations was studied in four squirrel monkeys after unilateral plugging of the three semicircular canals. During the period (1-4 days) that animals were kept in darkness after plugging, the gain during steps of acceleration (3, 000 degrees /s(2), peak velocity = 150 degrees /s) was 0.61 +/- 0.14 (mean +/- SD) for contralesional rotations and 0.33 +/- 0.03 for ipsilesional rotations. Within 18-24 h after animals were returned to light, the VOR gain for contralesional rotations increased to 0. 88 +/- 0.05, whereas there was only a slight increase in the gain for ipsilesional rotations to 0.37 +/- 0.07. A symmetrical increase in the gain measured at the plateau of head velocity was noted after animals were returned to light. The latency of the VOR was 8.2 +/- 0. 4 ms for ipsilesional and 7.1 +/- 0.3 ms for contralesional rotations. The VOR evoked by sinusoidal rotations of 0.5-15 Hz, +/-20 degrees /s had no significant half-cycle asymmetries. The recovery of gain for these responses after plugging was greater at lower than at higher frequencies. Responses to rotations at higher velocities for frequencies >/=4 Hz showed an increase in contralesional half-cycle gain, whereas ipsilesional half-cycle gain was unchanged. A residual response that appeared to be canal and not otolith mediated was noted after plugging of all six semicircular canals. This response increased with frequency to reach a gain of 0.23 +/- 0.03 at 15 Hz, resembling that predicted based on a reduction of the dominant time constant of the canal to 32 ms after plugging. A model incorporating linear and nonlinear pathways was used to simulate the data. The coefficients of this model were determined from data in animals with intact vestibular function. Selective increases in the gain for the linear and nonlinear pathways predicted the changes in recovery observed after canal plugging. An increase in gain of the linear pathway accounted for the recovery in VOR gain for both responses at the velocity plateau of the steps of acceleration and for the sinusoidal rotations at lower peak velocities. The increase in gain for contralesional responses to steps of acceleration and sinusoidal rotations at higher frequencies and velocities was due to an increase in the gain of the nonlinear pathway. This pathway was driven into inhibitory cutoff at low velocities and therefore made no contribution for rotations toward the ipsilesional side.

NASA Discipline Developmental Biology↗

Application of Vacuum Swing Adsorption for Carbon Dioxide and Water Vapor Removal from Manned Spacecraft Atmospheres

In NASA's Vision for Space Exploration (Bush, 2004), (Griffin, 2007), humans will once again travel beyond the confines of earth's gravity, this time to remain there for extended periods. These forays will place unprecedented demands on launch systems. They must not only blast out of earth's gravity well as during the Apollo moon missions, but also liftoff the supplies needed to sustain a larger crew over much longer periods. Thus all spacecraft systems, including those for the separation of metabolic carbon dioxide and water from a crewed vehicle, must be minimized with respect to mass, power, and volume. Emphasis is also placed on system robustness both to minimize replacement parts and ensure crew safety when a quick return to earth is not possible. For short-term phases of manned space exploration, such as transit from the earth to the moon, venting of metabolic carbon dioxide and water to space is more efficient than the inclusion of large recycling systems on the spacecraft. The baseline system for the Orion spacecraft is an amine-based vacuum swing system (Smith, Perry et aI., 2006). As part of the development of an alternative approach, a sorbent-based CO2 and H2O removal system (Knox, Adams et aI., 2006), subscale testing was conducted to evaluate potential performance improvements obtainable by recuperating the heat of adsorption to aid in vacuum desorption. This bed design is shown in Figure 1, is depicted here with a lattice structure instead of reticulated foam for heat transfer. The slot widths are approximately 1.2 mm wide and 8.5 mm long. Bed depth is approximately 4.7 mm. Headers (not shown) were produced by the stereo lithography apparatus at MSFC.

Knox, J.↗

Engineered Structured Sorbents for the Adsorption of Carbon Dioxide and Water Vapor from Manned Spacecraft Atmospheres: Applications and Modeling 2007/2008

In NASA s Vision for Space Exploration, humans will once again travel beyond the confines of earth s gravity, this time to remain there for extended periods. These forays will place unprecedented demands on launch systems. They must not only blast out of earth s gravity well as during the Apollo moon missions, but also launch the supplies needed to sustain a larger crew over much longer periods. Thus all spacecraft systems, including those for the separation of metabolic carbon dioxide and water from a crewed vehicle, must be minimized with respect to mass, power, and volume. Emphasis is also placed on system robustness both to minimize replacement parts and ensure crew safety when a quick return to earth is not possible. This paper describes efforts to improve on typical packed beds of sorbent pellets by making use of structured sorbents and alternate bed configurations to improve system efficiency and reliability. The development efforts described offer a complimentary approach combining testing of subscale systems and multiphysics computer simulations to characterize the regenerative heating substrates and evaluation of engineered structured sorbent geometries. Mass transfer, heat transfer, and fluid dynamics are included in the transient simulations.

Knox, James C.↗

Validation of a Manually Oscillating Chair for In-The-Field Assessment of Dynamic Visual Acuity on Crewmembers Within Hours of Returning From Long-Duration Spaceflight

Long-duration spaceflight results in sensorimotor adaptations, which cause functional deficits during gravitational transitions, such as landing on a planetary surface after long-duration microgravity exposure. Both the vestibular system and the central nervous system are affected by gravitational transitions. These systems are responsible for coordinating head and eye movements via the vestibulo-ocular reflex (VOR) and go through an adaptation period upon exposure to microgravity. Consequently, they must also re-adapt to Earth's gravitational environment upon landing. This re-adaptation causes decrements in gaze control and dynamic visual acuity, with crewmembers reporting oscillopsia and blurred vision caused by retinal slip, or the inability to keep an image focused on their retina. This is thought to drive motion sickness symptoms experienced by most crewmembers following landing. Retinal slip can be estimated by dynamic visual acuity (DVA); visual acuity while in motion. Previously, DVA has been assessed in the laboratory where subjects walked at 6.4 km/hr on a motorized treadmill. Using this method, Peters et al. (2011) found that DVA is worsened in astronauts by an average of 0.75 eye-chart lines one day after landing. However, it is believed that re-adaptation occurs quickly and that DVA might be worse immediately upon re-exposure to a gravitational environment. Since many crewmembers are unable to walk safely upon landing, it was necessary to develop a method for replicating the vertical head movements associated with walking. In addition, the use of a chair to imitate the head displacement caused by walking isolates eye-head interactions without allowing for trunk and lower-body compensation, as seen with treadmill walking (Mulavara & Bloomberg 2003). Therefore, a modality for assessing DVA in the field within a few hours of landing was developed. In this study, we validated the ability of a manually operated oscillating chair to reproduce the oscillatory frequency of walking on a treadmill. Healthy non-astronaut subjects (n=14) participated in one test session and completed three static (seated) and three dynamic (walking/oscillated) visual acuity tests. DVA was assessed using a motorized treadmill, an automated oscillating chair, and a manually operated chair, both developed in the Neuroscience Laboratory at JSC. The automated chair was motor-driven and set to oscillate vertically at 2 Hz with a vertical displacement of +/- 5 cm to simulate vertical translation while walking. The manually operated chair was oscillated vertically by a test operator to the beat of a metronome at 120 beats/min (2 Hz) and a vertical displacement of approximately +/- 5 cm. As the subject was oscillated, they were asked to discern the direction gap of Landolt-C optotypes of varying sizes and verbally reported the direction while an operator recorded their response using a gamepad. Subjects were outfitted with accelerometers (sampling rate = 128 Hz) on their head, trunk and lumbar spine. A fast Fourier transform was performed on the vertical trunk acceleration to compare the peak and spread of the distribution of oscillation frequencies for each oscillating condition. The spread of the frequency distribution for the manual chair was not significantly different from either the treadmill or the automated chair. However, all three conditions had similar non-zero standard error values, suggesting a variance in head movement frequency which may affect DVA. The average oscillation frequency of the manual chair (1.85 Hz) was significantly different (α=0.05) from that of treadmill walking (2.24 Hz), but not significantly different from that of the automated chair (1.85 Hz) and all three conditions had small standard errors (SEM = 0.04, 0.06, and 0.08 Hz for manual, treadmill, and automated respectively). This implies that both chairs oscillate at a frequency below that of treadmill walking, but are comparable to each other and reproducible across sessions. Additionally, DVA scores did not vary significantly across conditions. The smaller spread values of the oscillating chairs' frequencies indicated mitigation of variation induced by locomotor strategies, which enables better examination of the issue of VOR adaptation. Furthermore, due to the deconditioned state of crewmembers in the initial hours after landing, it is easier to transport a manual bouncing chair into the field and safer to perform a vision test while seated in a chair versus walking on a treadmill. Therefore, the manually oscillating chair has been deemed to meet and exceed the DVA testing capabilities previously obtained by treadmill walking.

Kreutzberg, G. A.↗

SAGE III ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2π steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the ight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

SAGE III/ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2pi steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the flight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

Neural Network Based Optimal Control: Resilience to Missed Thrust Events for Long Duration Transfers

A growing number of spacecraft are continuing to adopt new and more efficient forms of in-space propulsion. One shared characteristic of these high-efficiency propulsion techniques is their limited thrust capabilities. This requires them to thrust continuously for long periods of time, making the spacecraft susceptible to potential missed thrust events. This work demonstrates how neural networks can autonomously correct for missed thrust events during a low-thrust long-duration transfer trajectory. The research applies and tests the developed method to au- tonomously correct a Mars return trajectory. Additionally, methods for improving the response of neural networks to missed thrust events are presented and further investigated.

Laipert, Frank E.↗

Control Mechanisms for Self‐Sealing in Activated Clay‐Rich Faults Through Controlled Hydraulic Injection Experiment

Abstract In a high‐pressure injection fault activation experiment conducted at the Mont Terri underground research laboratory in Switzerland, the transmissivity of the Opalinus Clay fault significantly increased due to opening and shearing. The fluid injection, spanning a few hours, generated a 10 m radius fault activation patch. Subsequent pressure pulse tests conducted bi‐weekly for a year revealed the gradual return of fault transmissivity to its initial state. The study utilized fluid pressure decay analysis, optical fiber monitoring, continuous active source seismic measurements and borehole displacement sensors for measuring fault displacements. The fault zone exhibited a dilation of approximately 1.4 mm, associated with both normal and tangential movements during activation, resulting in a sudden transmissivity increase from 1 × 10 −12 to 3.2 × 10 −7 m 2 /s. Early post‐activation, transient compaction and the subsequent slow compaction were observed, transitioning to an extension regime. The pressure pulse tests demonstrated a rapid transmissivity drop by more than two orders of magnitude within the first 10 days, followed by a gradual and less pronounced decrease. Plastic shear and compaction dominated the transmissivity evolution until 70 days after injection ended, followed by a period where additional factors, such as clay mineral swelling, influenced the behavior. Extrapolation suggested a sealing process taking at least 50 years after the initial activation. Plain Language Summary A field‐scale fault activation experiment offers valuable insights into the elasto‐plastic processes governing the sealing of shale faults. The experiment reveals a rapid increase in the fault's transmissivity by approximately five orders of magnitude during activation. Subsequent observations show a gradual transmissivity decrease by about three orders of magnitude post‐activation, with slow long‐term plastic shear and compaction of the fault competing against secondary processes, notably clay mineral swelling. All conceptual models employed to interpret these field data converge on the estimation that the fault's return to its initial low transmissivity state would require a minimum of 50 years. Key Points High‐pressure injection fault activation experiment at the Mont Terri underground research laboratory Continuous transmissivity measurements record self‐sealing inside a clay‐rich fault zone Transmissivity undergoes a phase of domination by slow plastic compaction and shearing during the initial post‐activation period, with mineral swelling exerting its influence over the long term

Guglielmi, Yves↗

The Viking seismic experiment

A three-axis short-period seismometer is now operating on Mars in the Utopia Planitia region. The noise background correlates well with wind gusts. Although no quakes have been detected in the first 60 days of observation, it is premature to draw any conclusions about the seismicity of Mars. The instrument is expected to return data for at least 2 years.

Anderson, D. L.↗

Echocardiographic evaluation of Space Shuttle crewmembers

Echocardiographic measurements of left ventricular volume were obtained from 17 members of four Space Shuttle crews before and after 5- to 8-day space flights. Measurements obtained 1 h after landing indicated increases in the heart rate (HR), mean arterial pressure, and systemic vascular resistance values. On the other hand, the end-diastolic volume index (EDVI) fell 17 ml/sq m, and the stroke volume index (SVI) fell 15 ml/sq m. Measurements taken 1-2 weeks later demonstrated that the HR values returned to normal, but the EDVI and SVI values remained significantly below preflight levels, despite the ability of the subjects to ambulate and exercise. The results indicate that a space flight induces significant changes in heart volume affecting the left-ventricle function. It is suggested that the prolonged recovery period is related to the high level of aerobic conditioning in these subjects.

Bungo, M. W.↗

Overview of the Environmental Control and Life Support System (ECLSS) Testing At MSFC

Previously, almost all water used by the crew during space flight has been transported from earth or generated in-flight as a by-product of fuel cells. Additionally, this water has been stored and used for relatively short periods. To achieve the United States' commitment to a permanent manned presence in space, more innovative techniques are demanded. Over 20,000 pounds of water and large quantities of air would have to be transported to the International Space Station (ISS) every 90 days with a corresponding amount of waste returned to earth, for an 8-person crew. This approach results in prohibitive logistics costs, and necessitates near complete recovery and recycling of water. The potential hazards associated with long-term reuse of reclaimed water and revitalized air resulted in the recognition that additional characterization of closed-loop systems and products is essential. Integrated physical/chemical systems have been designed, assembled, and operated to provide air and potable water meeting ISS quality specifications. The purpose of the Environmental Control and Life Support System (ECLSS) test program at NASA's Marshall Space Flight Center is to conduct research related to the performance of the ISS and its Environmental Control components. The ECLSS Test Program encompasses the Water Recovery Test (WRT), the Integrated Air Revitalization Test (IART), and Life Testing, which permits ECLSS design evaluation. These subsystems revitalize air and reclaim waste waters representative of those to be generated on-orbit. This paper provides an overview of MSFC's 1997 ECLSS testing. Specific tests include: the Stage 10 Water Recovery Test; the Contaminant Injection Test; the Performance Enhancement Test and Life Testing of the Four Bed Molecular Sieve; the Oxygen Generator Assembly Life Test; and the ISS Water Distribution Biofilm Life Test.

Traweek, Mary S.↗

Low Impact Docking System (LIDS)

Since 1996, NASA has been developing a docking system that will simplify operations and reduce risks associated with mating spacecraft. This effort has focused on developing and testing an original, reconfigurable, active, closed-loop, force-feedback controlled docking system using modern technologies. The primary objective of this effort has been to design a docking interface that is tunable to the unique performance requirements for all types of mating operations (i.e. docking and berthing, autonomous and piloted rendezvous, and in-space assembly of vehicles, modules and structures). The docking system must also support the transfer of crew, cargo, power, fluid, and data. As a result of the past 10 years of docking system advancement, the Low Impact Docking System or LIDS was developed. The current LIDS design incorporates the lessons learned and development experiences from both previous and existing docking systems. LIDS feasibility was established through multiple iterations of prototype hardware development and testing. Benefits of LIDS include safe, low impact mating operations, more effective and flexible mission implementation with an anytime/anywhere mating capability, system level redundancy, and a more affordable and sustainable mission architecture with reduced mission and life cycle costs. In 1996 the LIDS project, then known as the Advanced Docking Berthing System (ADBS) project, launched a four year developmental period. At the end of the four years, the team had built a prototype of the soft-capture hardware and verified the control system that will be used to control the soft-capture system. In 2001, the LIDS team was tasked to work with the X- 38 Crew Return Vehicle (CRV) project and build its first Engineering Development Unit (EDU).

LaBauve, Tobie E.↗

Trace Oxygen Measurements of Asteroid Sample Storage Desiccators

The Astromaterials Curation facility at the NASA Johnson Space Center is currently curating more than 120 g of carbonaceous asteroid Bennu material as well as over 500 mg of asteroid Ryugu [1 and 2]. These astromaterials are stored in isolating desiccators and gloveboxes under a continuous purge of pure (<1 ppm O 2 ) gaseous nitrogen. The oxygen and moisture concentrations in our OSIRIS-REx sample processing gloveboxes are continuously monitored via integrated sensors; however, our sample storage desiccators lack integrated oxygen and humidity sensors. In previous studies, we used PreSens Fibox 4 trace oxygen meters and optochemical PSt9 spot sensors to measure the oxygen concentrations in candidate asteroid sample containers that had been sealed in nitrogen; we determined that Eagle stainless steel containers inhibit the ingress of external oxygen for several weeks [3]. This optochemical sensor technology allowed us to take precise, contactless measurements within a trace range of 0 to 200 ppmv O 2 . The effectiveness of the trace oxygen sensors in our container experiments inspired us to utilize them to assess the performance of our desiccators that previously lacked trace oxygen monitoring. In this study, our goal was to determine the quality of the nitrogen purge in the isolating desiccator under normal operating conditions by measuring the trace oxygen content. Utilizing optochemical sensor technology, we determined how long the oxygen concentration takes to reach an equilibrium in the desiccator; that is, determine the rate at which the oxygen diffusion into the desiccator equals the rate at which oxygen diffuses out of the desiccator via N2 purge. Additionally, we wanted to determine the oxygen concentration at this equilibrium, the state in which our desiccators are in during normal operating conditions. We tested a custom three chamber desiccator manufactured by Germfree using a PSt9 trace oxygen sensor spot that was mounted into a ¼” National Pipe Tapered (NPT) metal flow-through cell and attached it to the desiccator exhaust. The desiccator consists of top, middle, and bottom isolating chambers. The top chamber door was opened for several minutes to simulate a sample exchange, it was sealed, and then purged ~15 Standard Cubic Feet per Hour (SCFH). Oxygen measurements were automatically recorded via the Fibox 4 trace oxygen meter in 5-minute intervals over the course of a 24-hour period. Our results indicate the desiccator reached an equilibrium value of 10-15 ppm O 2 after ~5 hours (Fig. 1). This data allows us to explore standards for purging and exchange protocols that can be applied to similar types of desiccators in Hayabusa2, OSIRIS-REx, and for sample return collections. The assessment of the internal gaseous compositions of desiccators also allows us to share with the community the N 2 environment in which many of our asteroid samples and hardware are securely curated. Future measurements will include other nitrogen flow rates and measuring the trace oxygen concentration as a function of time for the levels of the previous commercial desiccator in which the Hayabusa2 sample collection was stored. We will also analyze how long the desiccators hold N2 after being disconnected from their N2 source, an extended measurement for sample security reassurance.

Curation↗

A Novel Fiber-Bragg-Grating-Based Unique Identifier for Use in Tags and Seals

Tags and seals are important tools used in safeguards regimes for the control of nuclear materials. Vital to a successful tag or seal is the ability to securely, uniquely, and positively distinguish it from others of the same kind. This allows one to validate that items entered into an inspection regime to which the tag or seal is affixed are as claimed. We are developing a new type of unique identifier (UID) for such applications that is based on fiber-Bragg grating (FBG) technology. The index of refraction of the core glass of a fiber optic can be locally and permanently altered if sensitized fibers are exposed to intense ultraviolet light. This can be used to create index modulations with a regular periodicity comparable to the wavelengths of light with which the fiber is used. If broadband illumination is sent down the fiber, any light that is in resonance with the modulations will be reflected back to the input end of the fiber where it can be detected. The shape of the returned spectrum can be set by the modulation pattern written into the fiber’s core. We take advantage of these properties to create a compact UID that contains several FBGs potted into a monolithic body. By connecting the UID to an optical interrogator, the complex spectral return can be uniquely identified with a short measurement, providing a robust identification. As a device based on narrowband spectral returns, FBGs are inherently radiation tolerant, making them ideal for use with nuclear materials. Further, they can be read out remotely via a long fiber optic or locally via brief connection to a portable optical interrogator. Because the spectral signature of FBGs is sensitive to external mechanical perturbations, we are exploring the ability to reversibly alter the signature obtained from the UID by applying controlled mechanical forces with a simple device. Such a “key” will allow different stakeholders to obtain their own unique signature from the device, providing a new level of surety to safeguards inspections.

Ziock, Klaus-Peter↗

NASA's Rodent Research Project on ISS: Validation of a New Platform for Conducting Biomedical and Basic Research into the Consequences of Long Duration Habitation in Space

Rodent research has played a key role in advancing biomedical discoveries both on Earth and in space. The National Research Counsel’s Decadal survey(1) emphasized the importance of expanding NASAs life sciences research to perform long duration, rodent experiments on the International Space Station (ISS). To accomplish this objective, flight hardware, operations, and science capabilities were developed at NASA ARC to support both commercial and government-sponsored rodent research.Rodent Research-1 (RR-1) was the first mission in which animals were delivered and maintained in the ISS for a long duration mission in modified Animal Enclosure Module hardware. Both RR validation and commercial science objectives were pursued on the RR-1 mission. Adult female mice (20 total Flight, FLT) were launched Sept 21, 2014 in RR hardware within a Dragon Capsule (SpaceX4), then after 4 days in transit, were transferred for habitation on the ISS for 17 days (commercial) or 33 days (validation), when animals were euthanized and select tissues recovered on orbit. Various controls groups consisted of: 1) Basal mice from the same cohorts as FLT mice, but tissues were recovered at time of launch, 2) Vivarium (VIV) were housed in standard cages 3) Ground Controls (GC) were housed in flight hardware within an environmental chamber at Kennedy Space Center. The health and behavior of all mice on the ISS were monitored by video feed on a daily basis. Mice were euthanized by injection of Euthasol, then either fast frozen intact or dissected to preserve livers (fast frozen) and spleens (RNAlater). Samples were stored at ≤ -80˚C until their return to Earth for later analyses.Hardware performed nominally throughout the mission and the planned in-flight science operations were completed successfully. FLT mice appeared generally more physically active on orbit than respective GC groups. After 33 days on the ISS, mean body weights of FLT mice did not differ from GC, with both groups showing a 6% rise compared to time of launch, while VIV mice showed an 8% rise over the same period. Importantly, there were no significant differences in body weights between groups at the end of 33 days on the ISS, providing an indication that the RR hardware supported the health of the mice both on Earth and in space. Based on the preliminary data obtained from the livers and spleens of mice after 17 days on the ISS, purified RNA was of high quality (RIN values of spleen: FLT=9.48 +0.40, GC=9.28 +0.44, n=5/group); therefore, RNA quality from samples retrieved on orbit was acceptable for even the most demanding transcriptomic analyses. In addition, liver enzyme activity levels (units/mg protein) of FLT mice (after 17d on ISS) and all control mice were similar in magnitude to samples that were optimally prepared by freezing in liquid nitrogen in the laboratory (enzymes analyzed included catalase, glutathione reductase and glyceraldehyde-3-phosphate dehydrogenase). Validation analyses still in progress include behavior and tissue biochemistries, as well as optimization of science return by post-flight recovery of tissues for biospecimen sharing and global expression analyses.Together, these preliminary findings demonstrate new capability for supporting long duration rodent research on the ISS to achieve both basic science and biomedical objectives.

Globus, R. K.↗