Search NASA⌕ Search

SEARCH · Search NASA

Results for “Robustness analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis

Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results were compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of airframe/engine interactions in integrated flight and propulsion control

An analysis framework for the assessment of dynamic cross-coupling between airframe and engine systems from the perspective of integrated flight/propulsion control is presented. This analysis involves to determining the significance of the interactions with respect to deterioration in stability robustness and performance, as well as critical frequency ranges where problems may occur due to these interactions. The analysis illustrated here investigates both the airframe's effects on the engine control loops and the engine's effects on the airframe control loops in two case studies. The second case study involves a multi-input/multi-output analysis of the airframe. Sensitivity studies are performed on critical interactions to examine the degradations in the system's stability robustness and performance. Magnitudes of the interactions required to cause instabilities, as well as the frequencies at which the instabilities occur are recorded. Finally, the analysis framework is expanded to include control laws which contain cross-feeds between the airframe and engine systems.

Schierman, John D.↗

A versatile machine learning workflow for high-throughput analysis of supported metal catalyst particles

Accurate and efficient characterization of nanoparticles (NPs), particularly regarding particle size distribution, is essential for advancing our understanding of their structure-property relationship and facilitating their design for various applications. In this study, we introduce a novel two-stage artificial intelligence (AI)-driven workflow for NP analysis that leverages prompt engineering techniques from state-of-the-art single-stage object detection and large-scale vision transformer (ViT) architectures. This methodology is applied to transmission electron microscopy (TEM) and scanning TEM (STEM) images of heterogeneous catalysts, enabling high-resolution, high-throughput analysis of particle size distributions for supported metal catalyst NPs. The model's performance in detecting and segmenting NPs is validated across diverse heterogeneous catalyst systems, including various metals (Ru, Cu, PtCo, and Pt), supports (silica (SiO 2 ), γ-alumina (γ-Al 2 O 3 ), and carbon black), and particle diameter size distributions with mean and standard deviations ranging from 1.6 ± 0.2 nm to 9.7 ± 4.6 nm. The proposed machine learning (ML) methodology achieved an average F1 overlap score of 0.91 ± 0.01 and demonstrated the ability to disentangle overlapping NPs anchored on catalytic support materials. The segmentation accuracy is further validated using the Hausdorff distance and robust Hausdorff distance metrics, with the 90th percent of the robust Hausdorff distance showing errors within 0.4 ± 0.1 nm to 1.4 ± 0.6 nm. In conclusion, our AI-assisted NP analysis workflow demonstrates robust generalization across diverse datasets and can be readily applied to similar NP segmentation tasks without requiring costly model retraining.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New free-wake analysis of rotorcraft hover performance using influence coefficients

Free-wake analyses of helicopter rotor wakes in hover using time stepping have been shown to encounter instabilities which preclude convergence to valid free-vortex solutions for rotor-wake geometries. Previous work has demonstrated that these convergence difficulties can be overcome by implementing a new free-wake analysis method based on the use of influence coefficients. The present paper reviews this approach and documents its incorporation into a hover performance analysis called Evaluation of Hover Performance using Influence Coefficients (EHPIC). The technical principles underlying the EHPIC code are described with emphasis on steps taken to develop the single-filament wake models used in previous work into a multifilament wake valid for realistic hover performance predictions. The coupling of the wake model to a lifting surface loads analysis is described, and sample problems are solved that illustrate the robustness of the method. Performance calculations are also undertaken for hover to illustrate the utility of EHPIC in the analysis of rotorcraft performance.

Quackenbush, Todd R.↗

Performance Evaluation of an Intelligent Sensor Platform for Radiation Monitoring Applications

Accurate, rugged, and reliable radiation detection systems are important for area and environmental monitoring applications. The desire for spectroscopic capability has increased in monitoring aspects of the nuclear fuel cycle to provide fast characterization of the radiation profile of a situation, such as the planned or unplanned release of material. The reduction or elimination of having to conduct sampling for laboratory analysis can result in significant cost savings for an industry, government agency, or regulatory body. A new system, comprised of a NaI:Tl scintillator and a G-M tube, has been designed and tested, taking into account the following end-user requirements: ease-of-use, capability to network and supervise multiple units, compact form factor, low power consumption, versatility, and stability. The detector sizes were selected to accommodate a dose rate up to 1 Sv/hr. Several algorithms and analysis routines have been developed to incorporate these key needs without sacrificing on accuracy, dynamic range, nuclide identification, and sensitivity. This presentation will introduce the major hardware and software components of the platform, as well as the user interface and data analysis workflow. Key features of the hardware include an environmentally robust housing, low power signal processing electronics, patented LED-based gain stabilization, and an embedded processor for unattended instrument management and data analysis. New and improved algorithms for determining scintillator gamma dose rates, total integrated dose, and nuclide identification will be introduced. The two detector elements were modeled with MCNP and validated experimentally. The results of the radiological testing shall be presented including energy resolution, throughput, dose response, and minimum detectable activities. The dose response has been evaluated in simulations and with measurements to ensure accurate response with respect to energy spectrum of the dose field and direction of the incident radiation. Spectroscopy evaluations, such as nuclide detection probability and false alarm rates, were performed and comparisons to existing algorithms shall also be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revisiting the ODE Method for Recursive Algorithms: Fast Convergence Using Quasi Stochastic Approximation

Several decades ago, Profs. Sean Meyn and Lei Guo were postdoctoral fellows at ANU, where they shared interest in recursive algorithms. It seems fitting to celebrate Lei Guo's 60th birthday with a review of the ODE Method and its recent evolution. The method has been regarded as a technique for algorithm analysis. It is argued that this viewpoint is backwards: The original stochastic approximation method was surely motivated by an ODE, and tools for analysis came much later (based on establishing robustness of Euler approximations). The paper presents a brief survey of recent research in machine learning that shows the power of algorithm design in continuous time, following by careful approximation to obtain a practical recursive algorithm. While these methods are usually presented in a stochastic setting, this is not a prerequisite. In fact, recent theory shows that rates of convergence can be dramatically accelerated by applying techniques inspired by quasi Monte-Carlo. Subject to conditions, the optimal rate of convergence can be obtained by applying the averaging technique of Polyak and Ruppert. The conditions are not universal, but theory suggests alternatives to achieve acceleration. The theory is illustrated with applications to gradient-free optimization, and policy gradient algorithms for reinforcement learning.

learning and adaptive systems in artificial intell↗

Clumping index estimation with 30°-tilted cameras in row crops: Evaluation of methods and segment size effects

The clumping index (CI) quantifies the spatial distribution of foliage elements and is essential for accurately estimating the plant area index (PAI), canopy radiative transfer, and photosynthesis. Traditionally, the finite-length averaging method (LX), the gap size distribution method (CC), and a combined approach of CC and LX (CLX) have been applied to instruments like TRAC and digital hemispherical photography to estimate CI. However, a comprehensive evaluation of these methods in row crops remains limited, especially regarding the influence of segment size on CI. Meanwhile, digital cameras offer a cost-effective and user-friendly solution for canopy measurements in row crops, yet their application in this context remains underexplored. In this study, we employed a new approach using a 30°-tilted digital camera to estimate CI in corn and soybean fields, applying the LX, CC, and CLX methods. We systematically assessed the performance of these three methods by combining field measurements in real-world fields with simulations using the LESS 3D radiative transfer model. Our results showed that CLX applied to the whole image and 45° segment offered accurate estimation of CI (bias within ±0.1, RMSE < 0.2) and PAI (bias within ±0.4, RMSE < 1) in real-world fields and LESS simulations. The accuracy of the LX method was highly sensitive to segment size, with the best performance observed at the 15° segment (PAI bias within ±0.4). In contrast, the CC method remained stable across different segment sizes, and its performance was generally comparable to that of LX, except at the 15° segment. Across view zenith angles, CI derived from CC generally showed a continuous increase, while those from LX and CLX followed a rising trend at small zenith angles but began to decline at 68°, likely due to an increasing proportion of no-gap segments. Seasonally, LX tended to show decreasing CI during early growth stages but increased as the canopy matured, whereas CC and CLX showed gradually increasing CI before plateauing at peak PAI. The 30°-tilted camera effectively captured CI variations across different angles and growth stages, making it a practical and robust instrument for row crop canopy structure analysis. Furthermore, applying these CI methods to digital cameras offers a low-cost and accessible CI estimation alternative, improving canopy structure monitoring accuracy in row crops.

30°-tilted camera↗

Ensemble cure kinetics network (ECK-Net): A method to derive cure kinetics of thermosetting resin

This paper introduces an Ensemble Cure Kinetics Network (ECK-Net), a neural network (NN)–based framework for modeling the cure kinetics of thermosetting resins within a phenomenological context. ECK-Net replaces traditional analytic models, which require extensive chemical insight and multiple isothermal/non-isothermal experiments, with a data-driven surrogate that maps nonlinear relationships between temperature, degree of cure, and reaction rate from differential scanning calorimetry data. The proposed approach predicts input-dependent kinetic coefficients of a generalized nth-order reaction equation rather than reaction rates directly, enabling a single unified model to represent various epoxy systems without relying on iso-conversional analysis or predefined functional forms. To ensure robustness, multiple independently trained networks under different random initializations are blended through an ensemble strategy, effectively mitigating the stochastic variability inherent to neural networks. The framework is validated using experimental datasets from multiple resin systems, including aerospace-grade materials (Toray 3900-2, Cycom 5320-1, and Hexcel 8552) and a windmill-grade resin (RIMR 035c). The model accurately reproduces the temporal evolution of the degree of cure under manufacturers’ recommended cure cycles across all tested resins systems, yielding Pearson’s correlation coefficients of 0.992, 0.994, 0.993, 0.997, respectively. To demonstrate process-level applicability, the trained network was implemented within the Abaqus environment to simulate out-of-autoclave (OOA) curing process of the CFRP panel composed of Toray T830H-6K/3900-2D prepreg. The simulation results showed excellent agreement with experimental temperature response (maximum peak temperature, simulation: 189.6 °C, experiment: 188.5 °C) and the final degree of cure (simulation: 0.948, experiment: 0.960 ± 0.013), confirming ECK-Net’s capability as a reliable alternative to conventional cure kinetics modeling methods.

Composite curing↗

Many-Body Benchmark of Electronic Charge and Spin Densities for Li 1–x NiO 2

Accurate benchmarks are particularly important for highly correlated oxides as mean-field approximations often fail to describe the subtle balance of charge transfer and magnetism in these materials with an accuracy comparable to experimental needs. Here we present accurate diffusion Monte Carlo (DMC) results of the electronic charge and spin densities for the tunable highly correlated oxide Li 1–x NiO 2 for x = 0, 1/2, and 1. To enable quantitative comparisons, we introduce a robust density-partitioning scheme, extending Voronoi analysis to assign atomic charges from spatially noisy DMC densities. We then benchmark common approximations used in density functional theory (DFT). Comparison against DMC shows that r 2 SCAN delivers the most balanced performance across charge, spin, and radial density descriptors, nearly reproducing DMC results for LiNiO 2 and apical Ni sites in Li 0.5 NiO 2 . Hybrid functionals (PBE0, SCAN0) perform unexpectedly poorly, and PBE + U + V yields inconsistent trends between charge and spin densities. Therefore, the r 2 SCAN functional minimizes errors relative to DMC while capturing the variable valence of the Ni ion and also retaining the computational efficiency of DFT for large-scale simulations of the tunable structural and electronic phases of Li1−xNiO2. Our study highlights the importance of accurate benchmarking of the fundamental quantities involved in DFT to select appropriate DFT approximations in order to advance the predictive modeling of charge-transfer-driven phenomena in correlated electron systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and validation of a mathematical model of heart rate response to fluid perturbation

Physiological closed-loop controlled (PCLC) medical devices monitor and automatically adjust the patient’s condition by using physiological variables as feedback, ideally with minimal human intervention to achieve the target levels set by a clinician. PCLC devices present a challenge when it comes to evaluating their performance, where conducting large clinical trials can be expensive. Virtual physiological patients simulated by validated mathematical models can be utilized to obtain preclinical evidence of safety and assess the performance of the PCLC medical device during normal and worst-case conditions that are unlikely to happen in a limited clinical trial. A physiological variable that plays a major role during fluid resuscitation is heart rate (HR). For in silico assessment of PCLC medical devices regarding fluid perturbation, there is currently no mathematical model of HR validated in terms of its predictive capability performance. This paper develops and validates a mathematical model of HR response using data collected from sheep subjects undergoing hemorrhage and fluid infusion. The model proved to be accurate in estimating the HR response to fluid perturbation, where averaged between 21 calibration datasets, the fitting performance showed a normalized root mean square error (NRMSE) of 7.41 ± 2.8%. The model was also evaluated in terms of model predictive capability performance via a leave-one-out procedure (21 subjects) and an independent validation dataset (6 subjects). Two different virtual cohort generation tools were used in each validation analysis. The generated envelope of virtual subjects robustly met the defined acceptance criteria, in which 95% of the testing datasets presented simulated HR patterns that were within a deviation of 50% from the observed data. In addition, out of 16000 and 18522 simulated subjects for the leave one-out and independent datasets, the model was able to generate at least one virtual subject that was close to the real subject within an error margin of 9.56 ± 3.15% and 11.1 ± 1.22% NRMSE, respectively. In conclusion, the model can generate valid virtual HR physiological responses to fluid perturbation and be incorporated into future non-clinical simulated testing setups for assessing PCLC devices intended for fluid resuscitation.

59 BASIC BIOLOGICAL SCIENCES↗

Ensemble voting-based fault classification and location identification for a distribution system with microgrids using smart meter measurements

This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Growing ordered and stable nanostructures on polyhedral nanocrystals

Using both theoretical analysis and phase field simulation, we reveal robust and facile self-assembly routes, which allow the growth of different stable and ordered nanostructures on various polyhedral nanocrystals (NCs) heteroepitaxially. Our studies show that by increasing the NC's size, transitions from formal growth to ordered quantum dots on the facets and further to ordered quantum dots on the corners take place. The predicted morphologies and their transitions are in excellent agreement with existing widely scattered experimental results. Our study presents a facile and potentially practical route for mass-producing hybrid NCs with well-defined size, shape, composition, and architecture.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving neutrino-nuclei interaction models: Recommendations and case studies on Peelle’s Pertinent Puzzle

Improving the modeling of neutrino-nuclei interactions using data-driven methods is crucial for high-precision neutrino oscillation experiments. This paper investigates Peelle’s Pertinent Puzzle (PPP) in the context of neutrino measurements, a longstanding challenge to fitting theoretical models to experimental data. Inconsistencies in data-model comparisons hinder efforts to enhance the accuracy and reliability of model predictions. We analyze various sources contributing to these inconsistencies and propose strategies to address them, supported by practical case studies. We advocate for incorporating model fitting exercises as a standard practice in cross section publications to enhance the robustness of results. We use a common analysis framework to explore PPP-related challenges with MicroBooNE and T2K data in an unified manner. Our findings offer valuable insights for improving the accuracy and reliability of neutrino-nuclei interaction models, particularly by systematically tuning models using data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark Energy Survey Year 6 results: Redshift calibration of the MagLim++ lens sample

In this work, we derive and calibrate the redshift distribution of the MagLim++ lens galaxy sample used in the Dark Energy Survey Year 6 (DES Y6) 3 x 2pt cosmology analysis. The 3 x 2pt analysis combines galaxy clustering from the lens galaxy sample and weak gravitational lensing. The redshift distributions are inferred using the SOMPZ method - a Self-Organizing Map framework that combines deep-field multi-band photometry, wide-field data, and a synthetic source injection ( B alrog) catalog. Key improvements over the DES Year 3 (Y3) calibration include a noise-weighted SOM metric, an expanded Balrog catalogue, and an improved scheme for propagating systematic uncertainties, which allows us to generate O(10 8 ) redshift realizations that collectively span the dominant sources of uncertainty. These realizations are then combined with independent clustering-redshift measurements via importance sampling. The resulting calibration achieves typical uncertainties on the mean redshift of 1-2%, corresponding to a 20-30% average reduction relative to DES Y3. We compress the n(z) uncertainties into a small number of orthogonal modes for use in cosmological inference. Marginalizing over these modes leads to only a minor degradation in cosmological constraints. Here, this analysis establishes the MagLim++ sample as a robust lens sample for precision cosmology with DES Y6 and provides a scalable framework for future surveys.

dark energy↗

First observations of solar halo gamma rays over a full solar cycle

We analyze 15 years of Fermi-LAT data and produce a detailed model of the Sun’s inverse-Compton scattering emission (solar halo), which is powered by interactions between ambient cosmic-ray electrons and positrons with sunlight. By developing a novel analysis method to analyze moving sources, we robustly detect the solar halo at energies between 31.6 MeV and 100 GeV, and angular extensions up to 45° from the Sun, providing new insight into spatial regions where there are no direct measurements of the Galactic cosmic-ray flux. The large statistical significance of our signal allows us to subdivide the data and provide the first 𝛾-ray probes into the time variation and azimuthal asymmetry of the solar modulation potential, finding time-dependent changes in solar modulation both parallel and perpendicular to the ecliptic plane. Our results are consistent with (but with independent uncertainties from) local cosmic-ray measurements, unlocking new probes into astrophysical processes near the solar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-BRD-06: Variation in Dynamic Positron Emission Tomography Imaging of Tumor Hypoxia in Early Stage Non-Small Cell Lung Cancer Patients Undergoing Stereotactic Body Radiotherapy

Purpose: Tumor hypoxia is correlated with treatment failure. To date, there are no published studies investigating hypoxia in non-small cell lung cancer (NSCLC) patients undergoing SBRT. We aim to use 18F-fluoromisonidazole (18F-FMISO) positron emission tomography (PET) imaging to non-invasively quantify the tumor hypoxic volume (HV), to elucidate potential roles of reoxygenation and tumor vascular response at high doses, and to identify an optimal prognostic imaging time-point. Methods: SBRT-eligible patients with NSCLC tumors >1cm were prospectively enrolled in an IRB-approved study. Computed Tomography and dynamic PET images (0–120min, 150–180min, and 210–240min post-injection) were acquired using a Siemens BiographmCT PET/CT scanner. 18F-FMISO PET was performed on a single patient at 3 different time points around a single SBRT delivery of 18 Gy and HVs were compared using a tumor-to-blood ratio (TBR)>1.2 and rate of influx (Ki)>0.0015 (Patlak). Results: Results from our first patient showed substantial temporal changes in HV following SBRT. Using a TBR threshold >1.2 and summed images 210–240min, the HVs were 19%, 31% and 13% of total tumor volume on day 0, 2 (48 hours post-SBRT), and 4 (96 hours post-SBRT). The absolute volume of hypoxia increased by nearly a factor of 2 after 18 Gy and then decreased almost to baseline 96 hours later. Selected imaging timepoints resulted in temporal changes in HV quantification obtained with TBR. Ki, calculated using 4-hour dynamic data, evaluated HVs as 22%, 75% and 21%, respectively. Conclusions: ith the results of only one patient, this novel pilot study highlights the potential benefit of 18F-FMISO PET imaging as results indicate substantial temporal changes in tumor HV post-SBRT. Analysis suggests that TBR is not a robust parameter for accurate HV quantification and heavily influenced by imaging timepoint selection. Kinetic modeling parameters are more sensitive and may aid in future treatment individualization based on patient-specific biological information.

60 APPLIED LIFE SCIENCES↗

SU-E-J-122: The CBCT Dose Calculation Using a Patient Specific CBCT Number to Mass Density Conversion Curve Based On a Novel Image Registration and Organ Mapping Method in Head-And-Neck Radiation Therapy

Purpose: To develop a CBCT HU correction method using a patient specific HU to mass density conversion curve based on a novel image registration and organ mapping method for head-and-neck radiation therapy. Methods: There are three steps to generate a patient specific CBCT HU to mass density conversion curve. First, we developed a novel robust image registration method based on sparseness analysis to register the planning CT (PCT) and the CBCT. Second, a novel organ mapping method was developed to transfer the organs at risk (OAR) contours from the PCT to the CBCT and corresponding mean HU values of each OAR were measured in both the PCT and CBCT volumes. Third, a set of PCT and CBCT HU to mass density conversion curves were created based on the mean HU values of OARs and the corresponding mass density of the OAR in the PCT. Then, we compared our proposed conversion curve with the traditional Catphan phantom based CBCT HU to mass density calibration curve. Both curves were input into the treatment planning system (TPS) for dose calculation. Last, the PTV and OAR doses, DVH and dose distributions of CBCT plans are compared to the original treatment plan. Results: One head-and-neck cases which contained a pair of PCT and CBCT was used. The dose differences between the PCT and CBCT plans using the proposed method are −1.33% for the mean PTV, 0.06% for PTV D95%, and −0.56% for the left neck. The dose differences between plans of PCT and CBCT corrected using the CATPhan based method are −4.39% for mean PTV, 4.07% for PTV D95%, and −2.01% for the left neck. Conclusion: The proposed CBCT HU correction method achieves better agreement with the original treatment plan compared to the traditional CATPhan based calibration method.

60 APPLIED LIFE SCIENCES↗