Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHUTDOWN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Water NSTF Design, Instrumentation, and Test Planning

The following report serves as a formal introduction to the water-based Natural convection Shutdown heat removal Test Facility (NSTF) program at Argonne. Since 2005, this US Department of Energy (DOE) sponsored program has conducted large scale experimental testing to generate high-quality and traceable validation data for guiding design decisions of the Reactor Cavity Cooling System (RCCS) concept for advanced reactor designs. The most recent facility iteration, and focus of this report, is the operation of a 1/2 scale model of a water-RCCS concept. Several features of the NSTF prototype align with the conceptual design that has been publicly released for the AREVA 625 MWt SC-HTGR. The design of the NSTF also retains all aspects common to a fundamental boiling water thermosiphon, and thus is well poised to provide necessary experimental data to advance basic understanding of natural circulation phenomena and contribute to computer code validation. Overall, the NSTF program operates to support the DOE vision of aiding US vendors in design choices of future reactor concepts, advancing the maturity of codes for licensing, and ultimately developing safe and reliable reactor technologies. In this report, the top-level program objectives, testing requirements, and unique considerations for the water cooled test assembly are discussed, and presented in sufficient depth to support defining the program’s overall scope and purpose. A discussion of the proposed 6-year testing program is then introduced, which outlines the specific strategy and testing plan for facility operations. The proposed testing plan has been developed to meet the toplevel objective of conducting high-quality test operations that span across a broad range of single- and two-phase operating conditions. Details of characterization, baseline test cases, accident scenario, and parametric variations are provided, including discussions of later-stage test cases that examine the influence of geometric variations and off-normal configurations. The facility design follows, including as-built dimensions and specifications of the various mechanical and liquid systems, design choices for the test section, water storage tank, and network piping. Specifications of the instrumentation suite are then presented, along with specific information on performance windows, measurement uncertainties, and installation locations. Finally, descriptions of the control systems and heat removal networks are provided, which have been engineered to support precise quantification of energy balances and facilitate well-controlled test operations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Technical Report for "Nuclear Technologies for Near Term Fusion Devices"

Over approximately 18 years, this project evolved to focus on a number of related topics, all tied to the nuclear analysis of fusion energy systems. For the earliest years, the University of Wisconsin (UW)’s effort was in support of the Advanced Power Extraction (APEX) study to investigate high power density first wall and blanket systems. A variety of design concepts were studied before this study gave way to a design effort for a US Test Blanket Module (TBM) to be installed in ITER. Simultaneous to this TBM project, nuclear analysis supported the conceptual design of a number of fusion nuclear science facilities that might fill a role in the path to fusion energy. Beginning in approximately 2005, this project added a component focused on the development of novel radiation transport software capability in support of the above nuclear analysis needs. Specifically, a clear need was identified to support neutron and photon transport on the complex geometries associated with Computer-Aided Design (CAD). Following the initial development of the Direct Accelerated Geoemtry Monte Carlo (DAGMC) capability, additional features were added, including unstructured mesh tallies and multi-physics analysis such as the Rigorous 2-Step (R2S) methodology for Shutdown Dose Rate (SDR) prediction. Throughout the project, there were also smaller tasks in support of the fusion materials community and for the testing of changes to the nuclear data that is fundamental to this kind of nuclear analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric and experimentally informed BWR Severe Accident Analysis Utilizing FeCrAl - M3FT-17OR020205041

Iron-chromium-aluminum (FeCrAl) alloys are being considered as advanced fuel cladding concepts with enhanced accident tolerance. At high temperatures, FeCrAl alloys have slower oxidation kinetics and higher strength compared with zirconium-based alloys. FeCrAl could be used for fuel cladding and spacer or mixing vane grids in light water reactors and/or as channel box material in boiling water reactors (BWRs). There is a need to assess the potential gains afforded by the FeCrAl accident-tolerant-fuel (ATF) concept over the existing zirconium-based materials employed today. To accurately assess the response of FeCrAl alloys under severe accident conditions, a number of FeCrAl properties and characteristics are required. These include thermophysical properties as well as burst characteristics, oxidation kinetics, possible eutectic interactions, and failure temperatures. These properties can vary among different FeCrAl alloys. Oak Ridge National Laboratory has pursued refined values for the oxidation kinetics of the B136Y FeCrAl alloy (Fe-13Cr-6Al wt %). This investigation included oxidation tests with varying heating rates and end-point temperatures in a steam environment. The rate constant for the low-temperature oxidation kinetics was found to be higher than that for the commercial APMT FeCrAl alloy (Fe-21Cr-5Al-3Mo wt %). Compared with APMT, a 5 times higher rate constant best predicted the entire dataset (root mean square deviation). Based on tests following heating rates comparable with those the cladding would experience during a station blackout, the transition to higher oxidation kinetics occurs at approximately 1,500°C. A parametric study varying the low-temperature FeCrAl oxidation kinetics was conducted for a BWR plant using FeCrAl fuel cladding and channel boxes using the MELCOR code. A range of station blackout severe accident scenarios were simulated for a BWR/4 reactor with Mark I containment. Increasing the FeCrAl low-temperature oxidation rate constant (3 times and 10 times that of the rate constant for APMT) had a negligible impact on the early stages of the accident and minor impacts on the accident progression after the first relocation of the fuel. At temperatures below 1,500°C, increasing the rate constant for APMT by a factor of 10 still resulted in only minor FeCrAl oxidation. In general, the gains afforded by the FeCrAl enhanced ATF concept with respect to accident sequence timing and combustible gas generation are consistent with previous efforts. Compared with the traditional Zircaloy-based cladding and channel box system, the FeCrAl concept could provide a few extra hours of time for operators to take mitigating actions and/or for evacuations to take place. A coolable core geometry is retained longer, enhancing the ability to stabilize an accident. For example, a station blackout was simulated in which cooling water injection was lost 36 hours after shutdown. The timing to first fuel relocation was delayed by approximately 5 h for the FeCrAl ATF concept compared with that of the traditional Zircaloy-based cladding and channel box system.

36 MATERIALS SCIENCE↗

Identification and Characterization of Thermal Fluid Phenomena Associated with Selected Operating/Accident Scenarios in Modular High Temperature Gas-cooled Reactors

Dominant phenomena are identified and characterized for the loss-of-forced-convection (LOFC) scenario, the depressurized loss-of-forced-convection (DLOFC) scenario, and the moisture ingress scenario with relief valves available scenario. These scenarios are considered for the modular high temperature gas-cooled reactor (MHTGR) baseline design—with both a prismatic core and a pebble-bed core. The objectives of this effort, described in the above paragraph, were achieved by following a methodology identified by the U.S. Nuclear Regulatory Commission (NRC) and recommended in their Regulatory Guide 1.203. The methodology employed is described. For the above scenarios, baseline phenomena identification and ranking tables (PIRTs) generated by a NRC-sponsored effort in 2008 for the LOFC and DLOFC scenarios and a baseline PIRT generated by a Department of Energy-sponsored effort in 2011 by their Next Generation Nuclear Plant (NGNP) Moisture Ingress Assessment Committee were used to identify the dominant phenomena and existing levels-of-knowledge. Ten dominant phenomena (with only medium or low levels-of-knowledge) were identified for the LOFC and DLOFC scenarios including: (1) Inlet plenum stratification and plumes, (2) core coolant flow distribution, (3) radiant heat transfer from the top of the core to the upper vessel head, (4) reactor cavity air circulation and heat transfer, (5) reactor cavity cooling system behavior, (6) decay heat distributions, (7) core effective thermal conductivity, (8) molecular diffusion in air ingress DLOFC, (9) duct exchange flow, (10) phenomena that affect cavity gas composition for air-ingress. Five dominant phenomena, with high levels of knowledge, were identified for the moisture-ingress scenario with relief valves available including: (1) flow through break, (2) moisture level in the primary, (3) transport to moisture monitor, (4) moisture monitor instrument response, and (5) heat removal by shutdown cooling system. These phenomena are discussed and characterized. A listing of experiments—both completed and ongoing—is given with a view toward including data useful for further more detailed examination of the dominant phenomena listed in the previous paragraph. Note that only data for the LOFC and DLOFC scenarios are listed—since the moisture ingress scenario with relief valves available –have been identified as having adequate levels-of-knowledge by the PIRT committee. Finally, a preliminary computational fluid dynamics (CFD) calculation of inlet plenum stratification and plumes is described. Techniques employed for this calculation are typical for preliminary scoping calculations performed to validate numeric tools.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Special Purpose Nuclear Reactor (5 MW) for Reliable Power at Remote Sites Assessment Report

The Phenomena Identification and Ranking Table (PIRT) technique was conducted on the Special Purpose Reactor nuclear plant design. The PIRT is a structured process to identify safety-relevant/safety-significant phenomena and assess the importance and knowledge base by ranking the phenomena. The Special Purpose Reactor is currently in the conceptual design stage. The candidate reactor has a solid monolithic stainless steel core with an array of heat pipes and fuel pellets embedded in the monolith. The heat pipes are used to remove heat from the core using simple, reliable, and well-characterized physics (capillarity, boiling, and condensation). In the initial design, one heat exchanger is used for the working fluid that produces energy, and a second heat exchanger is used to remove decay heat in emergency or shutdown conditions. In addition, a power conversion cycle such as an open-air Brayton system is available as an option for power conversion and process heat. This report summarizes and documents the process and scope of the four PIRT reviews, noting the major activities and conclusions. The identified phenomena, analyses, rationales, and associated ratings are presented along with a summary of the findings from the four individual PIRTs, namely (1) Reactor Accident and Normal Operations, (2) Heat Pipes, (3) Materials, and (4) Power Conversion. The PIRT reports for these four major system areas evaluated are attached as appendixes to this report and provide considerably more detail about each assessment as well as a more complete listing of the phenomena that were evaluated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY2017 Updates to the SAS4A/SASSYS-1 Safety Analysis Code

The SAS4A/SASSYS-1 safety analysis software is used to perform deterministic analysis of anticipated events as well as design-basis and beyond-design-basis accidents for advanced fast reactors. It plays a central role in the analysis of U.S. DOE conceptual designs, proposed test and demonstration reactors, and in domestic and international collaborations. This report summarizes the code development activities that have taken place during FY2017. Extensions to the void and cladding reactivity feedback models have been implemented, and Control System capabilities have been improved through a new virtual data acquisition system for plant state variables and an additional Block Signal for a variable lag compensator to represent reactivity feedback for novel shutdown devices. Current code development and maintenance needs are also summarized in three key areas: software quality assurance, modeling improvements, and maintenance of related tools. With ongoing support, SAS4A/SASSYS-1 can continue to fulfill its growing role in fast reactor safety analysis and help solidify DOE’s leadership role in fast reactor safety both domestically and in international collaborations.

97 MATHEMATICS AND COMPUTING↗

Final Project Report on Computational Modeling and Analysis of Air-Based NSTF

The Reactor Cavity Cooling System (RCCS) is a passive safety concept under consideration for the overall safety strategy of advanced reactors such as the High Temperature Gas-Cooled Reactor (HTGR). The air-cooled RCCS uses natural convection to drive the flow of air from outside the power plant to remove decay heat during normal operation and accident scenarios. The Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne National Laboratory (“Argonne”) is a ½ - scale model of the primary features of one conceptual air-cooled RCCS design. The NSTF program performs ex-vessel, passive heat removal experiments in support of Department of Energy Office of Nuclear Energy’s Advanced Reactor Technology (ART) program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Well Integrity for Natural Gas Storage in Depleted Reservoirs and Aquifers

Natural gas storage facilities are a critical component of our energy supply and distribution chain, allowing elasticity in gas supply to accommodate daily to seasonal demand fluctuations. As has been made evident by the recent Aliso Canyon Gas Storage facility incident, a loss of well integrity may result in significant consequences, including the prolonged shutdown of an entire facility. The Aliso Canyon gas well blowout emitted approximately 100,000 tonnes of natural gas (mostly methane) over 4 months and displaced thousands of nearby residents from their homes. The high visibility of the event has led to increased scrutiny of the safety of natural gas storage at the Aliso Canyon facility, led to questions about energy reliability, and raised broader concerns for natural gas storage integrity throughout the country.

03 NATURAL GAS↗

Visual Inspection of Defense Waste Processing Facility Melter 2 Interior after End of Service

Defense Waste Processing Facility (DWPF) Melter 2 reached its end of service life after nearly14 years. A visual inspection of the interior of the melter was performed using a remotely operated camera to provide insight into melter performance and potential failure mechanisms. The condition of the interior of the melter was generally good considering its relatively long service life. The plenum refractory appeared to be in good condition. Spalling and wear of the glass contact refractory was evident at the melt line. There appeared to be some degree of degradation and deposition of material at the dome heater penetrations. Deformation, or sagging of the dome heaters was visible. Only the top surfaces of the upper electrodes were visible due to the full inventory of glass remaining after melter shutdown. The electrodes exhibited small cracks as well as minor deformation (creep or slumping). The lower electrode failure mechanism could not be determined since it was not visible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid-State Ultra-High Power Amplifier Modules Based on 100 V RF GaN Technology for LINACS Operating at 325 and 650 MHz

Purpose / objectives. This research project explores the groundwork for developing a new high efficiency, high reliability and cost effective radio frequency technology to be used in power sources for future linear accelerators. The frequencies of operation are 650 and 325 MHz, in use at Fermi National Laboratory. The technology can be extended to other frequencies. Brief Description. In this research work ultra-high power solid-state radio frequency sources are proposed operating at the stated frequencies of interest. The approach employs high voltage Gallium Nitride radio frequency transistors, operating at 100 V or higher, to achieve 5-kilowatts continuous-wave and 10 kilowatts pulse power level in a small form factor. The 5 kilowatts building block reduces the required number of combiners and related losses to achieve megawatts power levels. The design employs harmonic tuning techniques as used in class E, F and inverse F power amplifiers to achieve >70% efficiency and assembly techniques that overcome heat dissipation in such high power density systems. Solid-state technology achieves million hour operating lifetime compared to 10 – 100 thousand hours for incumbent technology based on vacuum tubes. Additionally, the modular approach afforded by a solid-state solution avoids complete system shutdown when one module fails. Overall, the approach reduces capital and operating cost. Research Results. During Phase I radio frequency Gallium Nitride building block transistors with 50 mm gate periphery were designed and built which achieve ~600 W continuous-wave when operating at 100 V bias and 1-kW pulsed when operating at 150V. This level of performance has been demonstrated with operation at 325 and 650 MHz, and in both cases measured efficiency exceeded 70%. Potential Applications. The technology identified as suitable for high efficiency power sources in particle accelerators can also be applied in megawatt class radars and several industrial, scientific and medical applications such as microwave sintering, radio frequency and microwave ablation, oil percolation, MRI scanners and Nuclear Magnetic Resonance spectrometers, etc… The high efficiency of these devices also translates into reduced electrical power consumption and lower cost of operation.

100 VDC↗

Evaluation of flow and heat transfer inside lean pre-mixed combustor systems under reacting flow conditions

The objective of the present work was to develop methodologies to measure heat transfer within a reacting gas turbine combustor. To accomplish this, an optically accessible research combustor system was designed and constructed at Virginia Tech, capable of operating at 650 K inlet temperature, maximum air mass flow rates of 1.3 kg/s, and flame temperatures over 1800 K. Flow and heat transfer measurements at non-reacting and reacting conditions were carried out for Reynolds numbers (Re) with respect to the combustor diameter ranging from ~11 500 to ~140 000 (depending on the condition). Particle Image Velocimetry (PIV) was used to measure the non-reacting flow field within the burner, leading to the identification of coherent structures in the flow that accounted for over 30% of the flow fluctuation kinetic energy along the swirling jet shear layers. The capability of infrared (IR) thermography to image surface temperatures through a fused silica (quartz) glass was demonstrated at non-reacting conditions. IR thermography was then used to measure the non-reacting steady state heat transfer along the combustor liner. A peak in heat transfer was identified at ~1 nozzle diameter downstream of the combustor dome plate. The peak Nusselt number along the liner was over 18 times higher than that predicted from fully developed turbulent pipe flow correlations, which have traditionally been used to estimate flame side combustor heat transfer. For the reacting measurements, a novel time-dependent heat transfer methodology was developed that allowed for the investigation of transient heat loads, including those occurring during engine ignition and shutdown. The methodology was validated at non-reacting conditions, by comparing results from an experiment with changing flow temperature, to the results obtained at steady state. The difference between the time-dependent and the steady state measurements were between 3% and 17.3% for different mass flow conditions. The time-dependent methodology was applied to reacting conditions for combustor Reynolds numbers of ~12 000 and ~24 000. At an equivalence ratio of ~0.5 and a combustor Reynolds number of ~12 000, the peak heat load location in reaction was shifted downstream by 0.2 nozzle diameters compared to the non-reacting cases. At higher equivalence ratios, and more visibly at a Reynolds number of ~24 000, the heat transfer distribution along the combustor liner exhibited two peaks, upstream and downstream of the impingement location (X/DN = 0.8-1.0 and X/DN ≈ 2.5). Reacting PIV was performed at Re = 12 000 showing the presence of a strong corner recirculation, which could potentially convect reactants upstream of the impingement point, leading to the double peak structure observed. The methodologies developed have provided insight into heat transfer within gas turbine combustors. The methods can be used to explore additional conditions and expand the dataset beyond what is presented, to fully characterize reacting combustor heat transfer.

42 ENGINEERING↗

Baseline Radiological Conditions for the Transient Reactor Test (TREAT) Restart

The Transient Reactor Test (TREAT) facility, located on the Idaho National Laboratory (INL), northwest of the Materials and Fuels Complex (MFC), has been in programmatic shutdown for more than twenty-three years. Construction of TREAT by the Teller Construction Co., Portland, Oregon, was started in February, 1958, and completed in early November, 1958. The reactor first achieved criticality on February 23, 1959. Operations continued until April 28, 1994, when the reactor was shut down due to the lack of a programmatic mission. Recently, the U.S. Department of Energy (DOE) identified a need to resume transient testing of new reactor fuels. The Resumption of Transient Testing Program (RTTP) has readied the TREAT facility to resume transient testing operations. The first reactor criticality since the shut down in 1994 was achieved on November 14, 2017. This report details the radiological measurements taken in the TREAT Reactor Building and the surrounding environment prior to and just after its restart in order to characterize the radiological conditions that existed prior to and during the initial restart operations. The authors would like to acknowledge the support from RTTP Management and the TREAT Operations staff for allowing the extensive radiological surveys, as well as the health physics technicians from the INL Radiological Control organization who performed many of the measurements referenced in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

PRA BASICS FOR REGULATORY APPLICATIONS P-105

This report includes the following: Course Overview •Separated into two sections –Section I - PRA methodology •First 11 modules of Section I •Overview of basic terms and concepts •Designed to provide information about the development of a probabilistic risk assessment model (all of the pieces) •Provide background information on different types of PRAs (external events, low power/ shutdown, Level 2 & 3) –Section II - PRA applications •Last 6 modules of Section II •Risk Informed Regulation and Risk Informed Decision-Making •NRC uses of PRA –Configuration risk management –Significance Determination –Mitigating System Performance Indicator

99 GENERAL AND MISCELLANEOUS↗

Analysis of Loss-of-Offsite-Power Events: 1987-2016

Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1987 through 2016. LOOP events during critical operation that do not result in a reactor trip are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. Emergency diesel generator reliability is also considered (failure to start, failure to load and run, and failure to run more than 1 hour). An adverse trend in overall LOOP frequency is identified. An adverse trend in LOOP durations is identified. Plant-centered and weather-related LOOP events do not show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1986–1996 time period.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On-Site Inspection RadioIsotopic Spectroscopy (Osiris) System-Integration and Field-Testing Report

We have designed a system for the acquisition and analysis of high-resolution gamma-ray spectra during on-site inspections under the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The On-Site Inspection RadioIsotopic Spectroscopy—OSIRIS —gamma-ray spectrometer is a mechanically-cooled, battery-powered ORTEC IDM-200V, chosen to avoid the need for liquid nitrogen during on-site inspections. The spectrometer is controlled and the spectral data analyzed by a Panasonic Toughbook notebook computer. Spectral data analysis is similar to that performed by traditional gamma-ray spectrometers, except the OSIRIS gamma-ray spectral data are filtered to display only radioisotopic information relevant to CTBT on-site inspections, for example, the fission-product isotope Zr-95 and its daughter isotope Nb-95. The OSIRIS software assists the user during operation with software checklists for startup and shutdown, and menu-selected display windows during energy calibration and data acquisition. OSIRIS can be operated in either sample-counting mode or the in-situ mode. In this report, the extensive system-integration tests of the OSIRIS system carried out in 2015-2017 are described, including tests at Idaho National Laboratory, at the Nevada National Security Site (formerly, the Nevada Test Site), and at Pacific Northwest National Laboratory in Richland, Washington. We also note recent software enhancements and the steps to our successful commercialization of OSIRIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BOP-301 and BOP-302R: Test Definitions and Analyses

Following the conclusion of the International Atomic Energy Agency (IAEA) coordinated research project (CRP) on analysis of two EBR-II tests, Argonne has continued its EBR-II analysis with additional tests from the Shutdown Heat Removal Test (SHRT) series. The tests selected for this follow-up analysis are BOP-301 and BOP-302R, two unprotected loss of heat of sink tests in which the intermediate sodium pump tripped without scramming the control rods or tripping the primary pumps. The IAEA CRP focused on the SHRT-17 and SHRT-45R tests, the most severe protected and unprotected loss of flow tests performed during the SHRT series. With the primary pumps tripping, flow rates decreased to levels where flowmeter uncertainty was very high. Accurately capturing the progressions of the two tests despite this uncertainty was one of the key modeling and simulation challenges during the CRP. BOP-301 and BOP-302R were selected because the primary sodium pumps did not trip for those tests. Primary flow rate measurements are known with greater certainty. Power and temperature discrepancies can be explored without concern that flow predictions match test measurements but not the actual flow rates from the tests. These two tests were performed during the same test window as SHRT-45R and had the same core load configuration. Therefore, core models created for analysis of SHRT-45R were easily adapted for analysis of BOP-301 and BOP-302R. Another reason for analyzing BOP-301 and BOP-302R is to analyze tests in which the core inlet temperature changed significantly, which did not occur during the loss of flow tests. The transient progression of the unprotected SHRT-45R test was driven by a decreasing core flow rate while the core inlet temperature remained relatively constant. For the BOP tests, the transient progression was driven by an increasing core inlet temperature while the core flow rate was stable. This report defines the BOP-301 and BOP-302R tests and provides a selection of measured test data. Initial predictions from SAS4A/SASSYS-1 simulations of these tests are then presented. Following these simulations, additional analysis was performed with the Dakota uncertainty quantification and optimization toolkit to determine which parameters have the greater impact on the transient results and the optimal values of the most important parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Development for TREAT Minimum Critical Mass Core Loading to Support Validation of TREAT Operations

Benchmark experiment data is necessary to validate modeling and simulation activities to support Transient Reactor Experiment Test (TREAT) Facility restart and operations. Key measurements of interest include criticality, control rod worth, excess reactivity, and shutdown margin for varying core loading sizes. Benchmark evaluations are being developed according the guidelines provided in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook) that can also support advanced modeling and simulation activities, new experiment design for advanced reactors and accident tolerant fuel, and potential low-enriched uranium conversion of the TREAT reactor. This summary discusses development activities supporting a benchmark evaluation of the TREAT minimum critical mass core loading, which will be submitted for peer-review and publication in the IRPhEP Handbook with the identifier TREAT-FUND-RESR-001. Detailed models of TREAT were developed and evaluated to prepare benchmark models of the minimum critical mass configuration. Calculations were performed using MCNP6.1 with ENDF/B-VII.1 nuclear data libraries. Discussion of results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Elementary Particle Physics

The UT Dallas High Energy Physics group collaborates on the ATLAS experiment which observes the world’s high energy proton-proton collisions. The UTD group utilized ATLAS 8 TeV Run 1 data to search for evidence of a “dark photon”, a gauge boson outside the “Standard Model of Particle Physics” that theorist hypothesize could mediate a force felt only by the dark matter particles that dominate out universe. The observable signature is a pair of prompt lepton jets. The results of this search were published in 2013. More recently, we have improved the sensitivity of the analysis using machine learning techniques, and we are extending the search to higher and lower mass dark photons using the ATLAS 13 TeV data set. Detection of a new fifth force would represent an important advance beyond the 4 known forces that influence baryonic matter. The LHC Long Shutdown 1 from 2013-2014 was a period of intense work on refurbishment and upgrades for the ATLAS Pixel community and the UTD group. The service quarter panels of the original Pixel detector were replaced, and the Insertable B Layer (IBL) detector was integrated. During IBL integration, UTD participated on the Stave Task Force that solved corrosion problems with IBL wire bonds. We developed a relative humidity sensor that was used during integration and transport to the beamline when detector was unpowered. The sensors were repurposed to monitor relative humidity inside the ID endplates until the built-in sensors were recommissioned. The UTD group worked on the connection of the Pixel and IBL at Point 1 and we were in charge of electric service testing. The IBL wire bond corrosion was the instigation for developing a new conformal coating method using an atomizing spray and Cellpack polyurethane. It is being considered for use in the ITk tracker upgrade. We have demonstrated its tolerance both of a 9 MGy ionizing dose and thermal expansion. Two UTD students are completing authorship qualification projects. One is helping understand variations in impact parameter resolution across different running periods. The second is developing a data-driven method to monitor the fraction of fake tracks in dense jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗