Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Scaling behavior studies of Ar{sup +} ion irradiated ripple structured mica surfaces

We have studied scaling behavior of ripple structured mica surfaces. Clean mica (001) surface is sputtered by 500 eV Ar{sup +} ion beam at 40° incidence angle for different time ranging from 28 minutes to 245 minutes to form ripples on it. The scaling of roughness of sputtered surface characterized by AFM is observed into two regime here; one is super roughening which is for above the crossover bombardment time (i.e, t{sub x} ≥ 105 min) with the scaling exponents α = α{sub s} = 1.45 ± 0.03, α{sub local} = 0.87 ± 0.03, β = 1.81 ± 0.01, β{sub local} = 1.67 ± 0.07 and another is a new type of scaling dynamics for t{sub x} ≤ 105 min with the scaling exponents α = 0.95 (calculated), α{sub s} = 1.45 ± 0.03, α{sub local} = 0.87 ± 0.03, β = 1.81 ± 0.01, β{sub local} = 1.67 ± 0.07. In the super roughening scaling dynamics, two types of power law dependency is observed on spatial frequency of morphology (k): for higher k values PSD ∼ k{sup −4} describing diffusion controlled smoothening and for lower k values PSD ∼ k{sup −2} reflecting kinetic roughening.

36 MATERIALS SCIENCE↗

Photon assisted processes: Probability amplitudes for the absorption and emission of photons and dc-photocurrents

In this paper one deals with the derivation of probability amplitudes characterizing the photon assisted injection of electrons in a two-terminal quantum conductor. For this purpose one accounts for spatially constant but time dependent periodic voltages applied on an Ohmic contact. Resorting to the discrete Fourier transform provides the probability amplitudes for the emission and absorption of photons in terms of squared Bessel functions of the first kind and integer order. Several kinds of ac-pulses like sinusoidal and dc+sinusoidal are assumed. Mean square values concerning photon numbers have been discussed in some more detail. Time averages of squared time dependent classical currents and leading corrections to the rescaled dc-photocurrent have also been accounted for.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the system stability and calibration of the image plate/scanner system for plasma diagnosis at the National Ignition Facility

At the National Ignition Facility (NIF), storage phosphor image plates (IP) are used extensively for recording x-rays, charged particles, and neutrons. For x-ray imaging and spectroscopy, absolute and relative calibrations are important for extracting plasma information from the diagnostics. We use Fuji MS, SR, and TR image plates that have been cut to fit custom diagnostic envelopes. The image plates are scanned on a General Electric FLA 7000 IP flying spot scanner. Calibrations for sensitivity, spatial scale, and temperature dependent fade are applied. During a set of recent calibrations, we noticed large shifts in the absolute calibration of the image plate system. The possible source of these shifts is discussed. We discuss scanner stability and a method for calibration. We discuss the fade and temperature effects of the image plates and how this correction is applied within the NIF environment. Here, we also compare our NIF GE FLA 7000 IP scanner with a new General Electric Amersham Typhoon IP scanner.

47 OTHER INSTRUMENTATION↗

Explaining an unusual electromigration behavior—A comprehensive experimental and theoretical analysis using finite element method

In metallic interconnects, it is generally assumed that electromigration (EM) failure location is independent of the applied electrical current and always occurs at the highest-current-density area. Our experiments show otherwise. We designed an Al interconnect that alters its failure location by only varying the applied current density. The failure occurs near the high for a current above 2 × 10 7 A/cm 2 , but at a location with 59% of the maximum for lower current densities. Thermoreflectance thermal imaging is employed to gather time-dependent high-resolution spatial temperature distributions of the Al interconnect during EM. More importantly, we propose a computationally inexpensive 2D finite element method that tracks EM evolution in time and matches well with the observations from different experimental conditions. A detailed analysis covering the major driving forces of EM is carried out to understand the complex physics behind EM. The atomic depletion rate contributed by each force is quantitatively studied. By examining the results from every tested experimental condition, the model reveals that the temperature gradient is the key reason causing atomic depletion near the failure location. Graphical illustrations and qualitative analysis are provided to intuitively show the key findings of our work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral and polarization based imaging in deep-ultraviolet excited photoelectron microscopy

Using photoelectron emission microscopy, nanoscale spectral imaging of atomically thin MoS2 buried between Al2O3 and SiO2 is achieved by monitoring the wavelength and polarization dependence of the photoelectron signal excited by deep-ultraviolet light. Although photons induce the photoemission, images can exhibit resolutions below the photon wavelength as electrons sense the response. To validate this concept, the dependence of photoemission yield on the wavelength and polarization of the exciting light was first measured and then compared to simulations of the optical response quantified with classical optical theory. A close correlation between experiment and theory indicates that photoemission probes the optical interaction of UV-light with the material stack directly. The utility of this probe is then demonstrated when both the spectral and polarization dependence of photoemission observe spatial variation consistent with grains and defects in buried MoS2. Taken together, these new modalities of photoelectron microscopy allow mapping of optical property variation at length scales unobtainable with conventional light-based microscopy.

Beechem, Thomas E. (ORCID:0000000275360719)↗

THE M31 VELOCITY VECTOR. I. HUBBLE SPACE TELESCOPE PROPER-MOTION MEASUREMENTS

We present the first proper-motion (PM) measurements for the galaxy M31. We obtained new V-band imaging data with the Hubble Space Telescope ACS/WFC and the WFC3/UVIS instruments of three fields: a spheroid field near the minor axis, an outer disk field along the major axis, and a field on the Giant Southern Stream. The data provide five to seven year time baselines with respect to pre-existing deep first-epoch observations of the same fields. We measure the positions of thousands of M31 stars and hundreds of compact background galaxies in each field. High accuracy and robustness is achieved by building and fitting a unique template for each individual object. The average PM for each field is obtained from the average motion of the M31 stars between the epochs with respect to the background galaxies. For the three fields, the observed PMs ({mu}{sub W}, {mu}{sub N}) are, in units of mas yr{sup -1}, (- 0.0458, -0.0376) {+-} (0.0165, 0.0154), (- 0.0533, -0.0104) {+-} (0.0246, 0.0244), and (- 0.0179, -0.0357) {+-} (0.0278, 0.0272), respectively. The ability to average over large numbers of objects and over the three fields yields a final displacement accuracy of a few thousandths of a pixel, corresponding to only 12 {mu}as yr{sup -1}. This is comparable to what has been achieved for other Local Group galaxies using Very Long Baseline Array observations of water masers. Potential systematic errors are controlled by an analysis strategy that corrects for detector charge transfer inefficiency, spatially and time-dependent geometric distortion, and point-spread function variations. The robustness of the PM measurements and uncertainties are supported by the fact that data from different instruments, taken at different times and with different telescope orientations, as well as measurements of different fields, all yield statistically consistent results. Papers II and III of this series explore the implications of the new measurements for our understanding of the history, future, and mass of the Local Group.

79 ASTRONOMY AND ASTROPHYSICS↗

S4: A spatial-spectral model for speckle suppression

High dynamic range imagers aim to block or eliminate light from a very bright primary star in order to make it possible to detect and measure far fainter companions; in real systems, a small fraction of the primary light is scattered, diffracted, and unocculted. We introduce S4, a flexible data-driven model for the unocculted (and highly speckled) light in the P1640 spectroscopic coronagraph. The model uses principal components analysis (PCA) to capture the spatial structure and wavelength dependence of the speckles, but not the signal produced by any companion. Consequently, the residual typically includes the companion signal. The companion can thus be found by filtering this error signal with a fixed companion model. The approach is sensitive to companions that are of the order of a percent of the brightness of the speckles, or up to 10{sup –7} times the brightness of the primary star. This outperforms existing methods by a factor of two to three and is close to the shot-noise physical limit.

79 ASTRONOMY AND ASTROPHYSICS↗

The reflection of a blast wave by a very intense explosion

We demonstrate that the geometric similarity of Taylor’s blast wave persists beyond reflection from an ideal surface. Upon impacting the surface, the spherical symmetry of the blast wave is lost but its cylindrical symmetry endures. As the flow acquires dependence on a second spatial dimension, an analytic solution of the Euler equations becomes elusive. However, the preservation of axisymmetry, geometric similarity and planar symmetry in the presence of a mirror-like surface causes all flow solutions to collapse when scaled by the height of burst (HOB) and the shock arrival time at the surface. The scaled blast volume for any yield, HOB and ambient air density follows a single universal trajectory for all scaled time, both before and after reflection.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Nearly optimal state preparation for quantum simulations of lattice gauge theories

Here, we present several improvements to the recently developed ground-state preparation algorithm based on the quantum eigenvalue transformation for unitary matrices (QETU), apply this algorithm to a lattice formulation of U(1) gauge theory in (2+1) dimensions, as well as propose an alternative application of QETU, a highly efficient preparation of Gaussian distributions. The QETU technique was originally proposed as an algorithm for nearly optimal ground-state preparation and ground-state energy estimation on early fault-tolerant devices. It uses the time-evolution input model, which can potentially overcome the large overall prefactor in the asymptotic gate cost arising in similar algorithms based on the Hamiltonian input model. We present modifications to the original QETU algorithm that significantly reduce the cost for the cases of both exact and Trotterized implementation of the time evolution circuit. We use QETU to prepare the ground state of a U(1) lattice gauge theory in two spatial dimensions, explore the dependence of computational resources on the desired precision and system parameters, and discuss the applicability of our results to general lattice gauge theories. We also demonstrate how the QETU technique can be utilized for preparing Gaussian distributions and wave packets in a way which outperforms existing algorithms for as little as n q ≳ 2–5 qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interface dynamics of a two-component Bose-Einstein condensate driven by an external force

The dynamics of an interface in a two-component Bose-Einstein condensate driven by a spatially uniform time-dependent force is studied. Starting from the Gross-Pitaevskii Lagrangian, the dispersion relation for linear waves and instabilities at the interface is derived by means of a variational approach. A number of diverse dynamical effects for different types of driving force is demonstrated, which includes the Rayleigh-Taylor instability for a constant force, the Richtmyer-Meshkov instability for a pulse force, dynamic stabilization of the Rayleigh-Taylor instability and onset of the parametric instability for an oscillating force. Gaussian Markovian and non-Markovian stochastic forces are also considered. It is found that the Markovian stochastic force does not produce any average effect on the dynamics of the interface, while the non-Markovian force leads to exponential perturbation growth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lifetime and emission characteristics of collective electronic excitations in two-dimensional optical lattices

Collective electronic excitations in planar optical lattices exhibit strong modifications of the radiative damping rate and directional emission pattern as compared to a single excited atom. Collective excitations for long wave numbers and polarizations orthogonal to the lattice plane exhibit superradiance with a very short lifetime and a tightly confined emission direction. For shorter wavelength and in-plane polarization, they can possess a long lifetime, which, beyond a critical wave number, tends to infinity. Those excitations thus become metastable and decoupled from the free radiation field. They can store a single energy quantum for a long time and transfer the excitation over long distances. In general the spatial, polarization, and frequency dependence of the emission pattern can provide us with optical and electronic properties of optical lattices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic correlations and structure in bixbyite across the spin-glass transition

Magnetic frustration in atomically ordered crystals gives rise to a broad range of quantum phenomena. The mineral bixbyite, F e 2 - x M n x O 3 , has magnetic frustration induced by atomic disorder. The end-members M n 2 O 3 and β - F e 2 O 3 both have magnetically ordered ground states, but the bixbyite crystal studied here, with a composition F e 1.12 M n 0.88 O 3 , instead undergoes a spin-glass-like transition near 32 K. Here, the magnetic correlations and atomic structure of bixbyite are followed across the spin-glass transition using powder and single-crystal neutron scattering. Refinement of Bragg intensities from neutron diffraction data allows precise determination of the average Fe and Mn concentration on the different crystallographic sites of the structure. No structural transitions occur in bixbyite upon cooling. Using the three-dimensional magnetic difference pair distribution function (3D-mΔPDF), the magnetic correlations are resolved spatially and their temperature dependence determined. The results demonstrate that the spin-spin correlations are strong well above the glass transition temperature, consistent with the spin-glass nature of the magnetism in bixbyite.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computation of the radiation amplitude of oscillons

The radiation loss of small-amplitude oscillons (very long-living, spatially localized, time-dependent solutions) in one-dimensional scalar field theories is computed in the small-amplitude expansion analytically using matched asymptotic series expansions and Borel summation. The amplitude of the radiation is beyond all orders in perturbation theory and the method used has been developed by Segur and Kruskal in Phys. Rev. Lett. 58, 747 (1987). Our results are in good agreement with those of long-time numerical simulations of oscillons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting the Amplitude Mode of Strongly Interacting Lattice Bosons by Bragg Scattering

We report the first detection of the Higgs-type amplitude mode using Bragg spectroscopy in a strongly interacting condensate of ultracold atoms in an optical lattice. By the comparison of our experimental data with a spatially resolved, time-dependent bosonic Gutzwiller calculation, we obtain good quantitative agreement. This allows for a clear identification of the amplitude mode, showing that it can be detected with full momentum resolution by going beyond the linear response regime. A systematic shift of the sound and amplitude modes' resonance frequencies due to the finite Bragg beam intensity is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES↗

A Hyperchromatic Lens for Recording Time-Resolved Phenomena

Current methods of recording multiple-frame images at short time scales are limited by electro-optic tube physics and radiometry. A new all-optical methodology has been developed for the capture of a high number of quasi-continuous effective frames of 2-D data at very short time scales (from less than 10–12 to more than 10–8 seconds), with improvement over existing framing camera technology in terms of short recording windows and effective number of frames. The methodology combines active illumination in which wavelength is dependent upon time and spatial position to encode temporal phenomena onto wavelength; a hyperchromatic lens to map wavelength onto axial position, and a recording technology, such as holography or plenoptic imaging, to capture the resultant focal stack in both spatial (imaging) and longitudinal (temporal) axes. The novel hyperchromatic lens we designed incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength, resulting in a 45 mm focal stack with nearly constant magnification for just 5 nm of illumination bandwidth. The fabricated lens assembly was qualified as meeting design requirements and images with the expected magnification at nearly the diffraction limit across the spectral range. This paper will focus on hyperchromatic lens design.

hyperchromat, time-resolved imaging, plenoptic ima↗

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-583: Operated Left Breast and Chest Wall Radiotherapy: A Dosimetric Comparison Between 3DCRT, IMRT and VMAT

Purpose: To evaluate the comparative dosimetric efficacy between field and field 3DCRT(FnF), multiple field Intensity modulated radiotherapy (SnS IMRT) and, partial arc volumetric modulated arc therapy (VMAT) in case of post operative left side breast and chest wall irradiation. Methods: CT study set of fifteen post-operative left breast and chest wall patient was tested for a treatment plan of 50Gy in 25 fraction using partial arc VMAT, SnSIMRT and tangential beam 3DCRT . 3DCRT FnF gantry angle was ranging for left medial tangential 290±17{sup 0} and Lt lateral tangential l14°±12{sup 0}. For IMRT four fixed beam at gantry angle G130{sup 0} G110{sup 0} G300{sup 0} and G330{sup 0} was used, in case of insufficient dose another beam G150{sup 0} was added. In case of partial arc VMAT, lateral tangential arc G130{sup 0}-G100{sup 0} and medial tangential arc G280{sup 0}-G310{sup 0}. Inverse optimization was opted to cover at least 95%PTV by 95% prescription dose (RxD) and a strong weightage on reduction of heart and lung dose. PTV coverage was evaluated for it’s clinically acceptability depending on the tumor spatial location and its quadrant. Out of the three plans, any one was used for the actual patient treatment. Results: Dosimetric analysis done for breast PTV, left lung, heart and the opposite breast. PTV mean dose and maximum dose was 5129.8±214.8cGy, 4749.0±329.7cGy, 5024.6±73.4cGy and 5855.2±510.7cGy, 5340.7±146.1cGy, 5347.2±196.8cGy for FnF, VMAT and IMRT respectively. Ipsilateral lung volume receiving 20Gy and 5Gy was 23.6±9.5cGy and 32.7±10.3cGy for FnF, 18.6±8.7cGy and 38.8±15.2cGy for VMAT and 25.7±9.6cGy and 50.7±8.4cGy for IMRT respectively. Heart mean and 2cc dose was 867.9±456.7cGy and 5038.5±184.3cGy for FnF, 532.6±263cGy and 3632.1±990.6 for VMAT, 711±229.9cGy and 4421±463.7cGy for IMRT respectively. VMAT shows minimum contralateral breast dose 168±113.8cGy. Conclusion: VMAT shows a better tumor conformity, minimum heart, ipsilateral lung and opposite breast dose. Cardiac Toxicity and risk of contralateral breast cancer can be reduce using VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗