Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Correlation and prediction uncertainties in the CyberKnife Synchrony respiratory tracking system

Purpose: The CyberKnife uses an online prediction model to improve radiation delivery when treating lung tumors. This study evaluates the prediction model used by the CyberKnife radiation therapy system in terms of treatment margins about the gross tumor volume (GTV). Methods: From the data log files produced by the CyberKnife synchrony model, the uncertainty in radiation delivery can be calculated. Modeler points indicate the tracked position of the tumor and Predictor points predict the position about 115 ms in the future. The discrepancy between Predictor points and their corresponding Modeler points was analyzed for 100 treatment model data sets from 23 de-identified lung patients. The treatment margins were determined in each anatomic direction to cover an arbitrary volume of the GTV, derived from the Modeler points, when the radiation is targeted at the Predictor points. Each treatment model had about 30 min of motion data, of which about 10 min constituted treatment time; only these 10 min were used in the analysis. The frequencies of margin sizes were analyzed and truncated Gaussian normal functions were fit to each direction's distribution. The standard deviation of each Gaussian distribution was then used to describe the necessary margin expansions in each signed dimension in order to achieve the desired coverage. In this study, 95% modeler point coverage was compared to 99% modeler coverage. Two other error sources were investigated: the correlation error and the targeting error. These were added to the prediction error to give an aggregate error for the CyberKnife during treatment of lung tumors. Results: Considering the magnitude of 2{sigma} from the mean of the Gaussian in each signed dimension, the margin expansions needed for 95% modeler point coverage were 1.2 mm in the lateral (LAT) direction and 1.7 mm in the anterior-posterior (AP) direction. For the superior-inferior (SI) direction, the fit was poor; but empirically, the expansions were 3.5 mm. For 99% modeler point coverage, the AP margin was 3.6 mm and the lateral margin was 2.9 mm. The SI margins for 99% modeler point coverage were highly variable. The aggregate error at 95% was 6.9 mm in the SI direction, 4.6 mm in the AP direction, and 3.5 in the lateral direction. Conclusions: The Predictor points follow the Modeler points closely. Margins were found in each clinical direction that would provide 95% modeler point coverage for 95% of the models reviewed in this study. Similar margins were found in two clinical directions for 99% modeler point coverage in 95% of models. These results can offer guidance in the selection of CTV margins for treatment with the CyberKnife.

61 RADIATION PROTECTION AND DOSIMETRY↗

In situ contact angle measurements of liquid CO 2 , brine, and Mount Simon sandstone core using micro X-ray CT imaging, sessile drop, and Lattice Boltzmann modeling

Three techniques to measure and understand the contact angle, θ, of a CO 2 /brine/rock system relevant to geologic carbon storage were performed with Mount Simon sandstone. Traditional sessile drop measurements of CO 2 /brine on the sample were conducted and a water-wet system was observed, as is expected. A novel series of measurements inside of a Mount Simon core, using a micro X-ray computed tomography imaging system with the ability to scan samples at elevated pressures, was used to examine the θ of residual bubbles of CO 2 . Within the sandstone core the matrix appeared to be neutrally wetting, with an average θ around 90°. A large standard deviation of θ (20.8°) within the core was also observed. To resolve this discrepancy between experimental measurements, a series of Lattice Boltzmann model simulations were performed with differing intrinsic θ values. The model results with a θ = 80° were shown to match the core measurements closely, in both magnitude and variation. The small volume and complex geometry of the pore spaces that CO 2 was trapped in is the most likely explanation of this discrepancy between measured values, though further work is warranted.

42 ENGINEERING↗

Investigation of Transmission Warming Technologies at Various Ambient Conditions

This work details two approaches for evaluating transmission warming technology: experimental dynamometer testing and development of a simplified transmission efficiency model to quantify effects under varied real world ambient and driving conditions. Two vehicles were used for this investigation: a 2013 Ford Taurus and a 2011 Ford Fusion. The Taurus included a production transmission warming system and was tested over hot and cold ambient temperatures with the transmission warming system enabled and disabled. A robot driver was used to minimize driver variability and increase repeatability. Additionally the Fusion was tested cold and with the transmission pre-heated prior to completing the test cycles. These data were used to develop a simplified thermally responsive transmission model to estimate effects of transmission warming in real world conditions. For the Taurus, the fuel consumption variability within one standard deviation was shown to be under 0.5% for eight repeat Urban Dynamometer Driving Cycles (UDDS). These results were valid with the transmission warming system active or passive. Using the transmission warming system under 22 degrees C ambient temperature, fuel consumption reduction was shown to be 1.4%. For the Fusion, pre-warming the transmission reduced fuel consumption 2.5% for an urban drive cycle at -7 degrees C ambient temperature, with 1.5% of the 2.5% gain associated with the transmission, while consumption for the US06 test was shown to be reduced by 7% with 5.5% of the 7% gain associated with the transmission. It was found that engine warming due to conduction between the pre-heated transmission and the engine resulted in the remainder of the benefit. For +22 degrees C ambient tests, the pre-heated transmission was shown to reduce fuel consumption approximately 1% on an urban cycle, while no benefit was seen for the US06 cycle. The simplified modeling results showed gains in efficiency ranging from 0-1.5% depending on the ambient temperature and drive cycle.

33 ADVANCED PROPULSION SYSTEMS↗

Ab initio determination of Bose-Hubbard parameters for two ultracold atoms in an optical lattice using a three-well potential

We calculate numerically the energy spectrum of the six dimensional problem of two interacting Bosons in a three-well optical lattice. The particles interact via a full Born-Oppenheimer potential, which can be adapted to model the behavior of the s-wave scattering length at Feshbach resonances. By adjusting the parameters of the corresponding Bose-Hubbard (BH) Hamiltonian the deviation between the numerical energy spectrum and the BH spectrum is minimized. This defines the optimal BH parameter set, which we compare to the standard parameters of the BH model. The range of validity of the BH model with these parameter sets is examined, and an analytical prediction of the interaction parameter is introduced. Furthermore, an extended BH model and implications due to the energy dependence of the scattering length and couplings to higher Bloch bands at a Feshbach resonance are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cluster-Continuum Calculations of Hydration Free Energies of Anions and Group 12 Divalent Cations

Understanding aqueous phase processes involving group 12 metal cations is relevant to both environmental and biological sciences. Here, quantum chemical methods and polarizable continuum models are used to compute the hydration free energies of a series of divalent group 12 metal cations (Zn2+, Cd2+, and Hg2+) together with Cu2+ and the anions OH , SH , Cl , and F . A cluster-continuum method is employed, in which gas-phase clusters of the ion and explicit solvent molecules are immersed in a dielectric continuum. Two approaches to define the size of the solute-water cluster are compared, in which the number of explicit waters used is either held constant or determined variationally as that of the most favorable hydration free energy. Results obtained with various polarizable continuum models are also presented. Each leg of the relevant thermodynamic cycle is analyzed in detail to determine how different contributions yield the observed mean signed error (MSE) and the standard deviation of the error (STDEV) between theory and experiment. The use of a constant number of water molecules for each set of ions is found to lead to predicted relative trends that benefit from error cancellation. Overall, the best results are obtained with MP2 and the Solvent Model D polarizable continuum model (SMD), with eight explicit water molecules for anions and ten for the metal cations, yielding a STDEV of 2.3 kcal/mol and MSE of 0.9 kcal/mol between theoretical to experimental hydration free energies, which range from -72.4 kcal/mol for SH to -505.9 kcal/mol for Cu2+. Using B3PW91 with DFT-D3 dispersion corrections (B3PW91-D) and SMD yields a STDEV of 3.3 kcal mol 1 and MSE of 1.6 kcal/mol, to which adding MP2 corrections from smaller divalent metal ion water molecule clusters yields very good agreement with the full MP2 results. Using B3PW91-D and SMD, with two explicit water molecules for anions and six for divalent metal cations also yields reasonable agreement with experiment, due in part to fortuitous error cancellation associated with the metal cations. Overall, the results indicate that the careful application of quantum chemical cluster-continuum methods provides valuable insights into aqueous ionic processes that depend on both local and long-range electrostatic interactions with the solvent.

binding energy↗

Comparative studies of 2HDMs under the Higgs boson precision measurements

We perform comparative studies for four types of the two Higgs Doublet Models (2HDMs) under the precision measurements of the Standard Model (SM) Higgs observables at the proposed Higgs factories. We explore the discovery potential based on the hypothetical deviations in the precision data for the 2HDMs up to one-loop level. We find 5σ observability from the χ2 fitting in a significant theory parameter space at future Higgs factories. For the Type-I 2HDM, regions with cos(β - α) ≲ -0.1 or cos(β - α) ≳ 0.08 are discoverable at more than 5σ level. For the other three types of 2HDMs, the 5σ region is even bigger: | cos(β - α)| ≳ 0.02 for tan β ~ 1. At small and large values of tan β, the region in cos(β - α) is further tightened. We examine the extent to which the different 2HDM theories may be distinguishable from one to the other at the 95% Confidence Level with four benchmark points as case studies. We show that a large part of the parameter space of the other types of 2HDMs can be distinguished from the benchmark points of the target model. The impacts of loop corrections are found to be significant in certain parameter regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preparation and performance study of MgFe{sub 2}O{sub 4}/metal–organic framework composite for rapid removal of organic dyes from water

In present study, a stable and magnetic metal-organic framework (MOF) material was synthesized by simple solvothermal method as adsorbent to rapid removal of two organic dyes, the Rhodamine B (RB) and Rhodamine 6G (Rh6G), in water samples. The prepared material showed great characteristics of large surface area (519.86 m{sup 2} g{sup −1}), excellent magnetic responsivity (35.00 emu g{sup −1}) and rapid removal (within 5 min). Maximum adsorption capacities of the magnetic material toward RB and Rh6G were up to 219.78 and 306.75 mg g{sup −1}, respectively. Adsorption kinetics suggested the adsorption process met the pseudo-second-order kinetic model. The prepared material could be reused at least 10 times by washing with acetonitrile solution, the relative standard deviation (RSD) of these ten cycles removal efficiency was 4.8%. In conclusion, good chemical inertness, a mechanical/water stability and super-hydrophilicity feature made this MOF a promising adsorbent for targets removal from environmental water sample. - Graphical abstract: The magnetic MgFe{sub 2}O{sub 4}/metal–organic framework with ultra-high adsorption capacity towards rhodamine dyes showed rapid removal efficiency (within 5 min) and good reusability (at least 10 times). Display Omitted - Highlights: • A stable and magnetic MgFe{sub 2}O{sub 4}@MOF material was synthesized as adsorbent to rapid removal of organic dyes. • The material in this article could rapidly sequestered rhodamine dyes within 5 min. • The maximum adsorption capacities of the magnetic material were high.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel thermal efficiency-based model for determination of thermal conductivity of membrane distillation membranes

Development and selection of membranes for membrane distillation (MD) could be accelerated if all performance-determining characteristics of the membrane could be obtained during MD operation without the need to recur to specialized or cumbersome porosity or thermal conductivity measurement techniques. By redefining the thermal efficiency, the Schofield method could be adapted to describe the flux without prior knowledge of membrane porosity, thickness, or thermal conductivity. A total of 17 commercially available membranes were analyzed in terms of flux and thermal efficiency to assess their suitability for application in MD. The thermal-efficiency based model described the flux with an average %RMSE of 4.5%, which was in the same range as the standard deviation on the measured flux. The redefinition of the thermal efficiency also enabled MD to be used as a novel thermal conductivity measurement device for thin porous hydrophobic films that cannot be measured with the conventional laser flash diffusivity technique.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

QCD contributions to the thermal history of the early Universe

We discuss the deviations from the ideal relativistic thermal bath. These deviations are dominated from quantum chromodynamic (QCD) corrections in the most part of the parameter space of the Standard Model (SM) and the Minimal Supersymmetric Standard Model (MSSM). These effects are relevant for astrophysical precision measurements and dynamics of scalar tensor theories (SST).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evolution of the Reactor Antineutrino Flux and Spectrum at Daya Bay

Here, the Daya Bay experiment has observed correlations between reactor core fuel evolution and changes in the reactor antineutrino flux and energy spectrum. Four antineutrino detectors in two experimental halls were used to identify 2.2 million inverse beta decays (IBDs) over 1230 days spanning multiple fuel cycles for each of six 2.9 GW th reactor cores at the Daya Bay and Ling Ao nuclear power plants. Using detector data spanning effective 239 Pu fission fractions F 239 from 0.25 to 0.35, Daya Bay measures an average IBD yield ¯σf of (5.90±0.13)×10 –43 cm 2 /fission and a fuel-dependent variation in the IBD yield, dσ f /dF 239 , of (–1.86±0.18)×10 –43 cm 2 /fission. This observation rejects the hypothesis of a constant antineutrino flux as a function of the 239 Pu fission fraction at 10 standard deviations. The variation in IBD yield is found to be energy dependent, rejecting the hypothesis of a constant antineutrino energy spectrum at 5.1 standard deviations. While measurements of the evolution in the IBD spectrum show general agreement with predictions from recent reactor models, the measured evolution in total IBD yield disagrees with recent predictions at 3.1σ. This discrepancy indicates that an overall deficit in the measured flux with respect to predictions does not result from equal fractional deficits from the primary fission isotopes 235 U, 239 Pu, 238 U, and 241 Pu. Based on measured IBD yield variations, yields of (6.17±0.17) and (4.27±0.26)×10 –43 cm 2 /fission have been determined for the two dominant fission parent isotopes 235 U and 239 Pu. A 7.8% discrepancy between the observed and predicted 235 U yields suggests that this isotope may be the primary contributor to the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-BRF-03: Effect of Radiation Therapy Planning Scan Registration On the Dose in Lung Cancer Patient CT Scans

Purpose: To characterize the effect of deformable registration of serial computed tomography (CT) scans on the radiation dose calculated from a treatment planning scan. Methods: Eighteen patients who received curative doses (≥60Gy, 2Gy/fraction) of photon radiation therapy for lung cancer treatment were retrospectively identified. For each patient, a diagnostic-quality pre-therapy (4–75 days) CT scan and a treatment planning scan with an associated dose map calculated in Pinnacle were collected. To establish baseline correspondence between scan pairs, a researcher manually identified anatomically corresponding landmark point pairs between the two scans. Pre-therapy scans were co-registered with planning scans (and associated dose maps) using the Plastimatch demons and Fraunhofer MEVIS deformable registration algorithms. Landmark points in each pretherapy scan were automatically mapped to the planning scan using the displacement vector field output from both registration algorithms. The absolute difference in planned dose (|ΔD|) between manually and automatically mapped landmark points was calculated. Using regression modeling, |ΔD| was modeled as a function of the distance between manually and automatically matched points (registration error, E), the dose standard deviation (SD-dose) in the eight-pixel neighborhood, and the registration algorithm used. Results: 52–92 landmark point pairs (median: 82) were identified in each patient's scans. Average |ΔD| across patients was 3.66Gy (range: 1.2–7.2Gy). |ΔD| was significantly reduced by 0.53Gy using Plastimatch demons compared with Fraunhofer MEVIS. |ΔD| increased significantly as a function of E (0.39Gy/mm) and SD-dose (2.23Gy/Gy). Conclusion: An average error of <4Gy in radiation dose was introduced when points were mapped between CT scan pairs using deformable registration. Dose differences following registration were significantly increased when the Fraunhofer MEVIS registration algorithm was used, spatial registration errors were larger, and dose gradient was higher (i.e., higher SD-dose). To our knowledge, this is the first study to directly compute dose errors following deformable registration of lung CT scans.

60 APPLIED LIFE SCIENCES↗

Magnetic In-Vacuum Field Mapping System for the Muon g-2 Experiment

The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon, $a^{}_\mu$ with a precision of 140ppb, a four-fold improvement over the former BNL E821 result. If the current discrepancy of about 3.5$\sigma$ between the Standard Model value for $a^{}_\mu$ and the former experiments was real, then the new experiment would verify the deviation with >7$\sigma$ significance. The experiment uses muons with the magic momentum of 3.09GeV/c stored in a very homogeneous magnetic field of a 45m long storage ring. The determination of $a^{}_\mu$ requires the precise knowledge of both the muon spin precession, $\omega^{}_a$, and the magnetic field, $\omega^{}_p$, expressed in terms of the free-proton Larmor frequency. The field measurement uses the high precision tool of pulsed proton Nuclear Magnetic Resonance and requires cross-calibrating a set of probes: a very accurate NMR probe calibrates the 17 probes on the in-vacuum field mapping system (the so-called trolley). This trolley in turn is used to map the field over the full azimuth of the storage ring. The trolley measurement also provides the calibration of the 378 fixed probes around the ring that constantly monitor the field drift. The trolley is particularly important as it measures the relevant field that is seen by the stored muons and this article presents the details of this field mapping system. This work was supported in part by the US DOE, Fermilab and US DOE OHEP under contract No. KA2201020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Valuation of Wind Energy Turbines Using Volatility of Wind and Price

The limitedness of the nonrenewable local energy resources in Israel, even in the background of the later gas fields’ findings, continues to force the state to devote various efforts towards ‘green’ energy development. These efforts include installations, both for the solar and for wind energy, thus improving the diversity of energy sources. While the standard discounted cash flow (DCF) method using the net present value (NPV) criterion is extensively adopted to evaluate investments, the standard DCF method is inappropriate for the rapidly changing investment climate and for the managerial flexibility in investment decisions. In recent years, the real options analysis (ROA) technique has been widely applied in many studies for the valuation of renewable energy investment projects. Taking into account the above background, we apply, in this study, the real options analysis approach for the valuation of wind energy turbines and apply it to the analysis of wind energy economic potential in Israel, which is the context of our work. We hypothesize that due to nature of wind energy production uncertainties, the ROA method is better than the alternative. The novelty of this paper includes the following: real world wind statistics of the Merom Golan site in Israel (velocity 3.73 m/s, with a standard deviation of 2.03 m/s), a realistic power generation estimation (power generation of 1205.84 kW with a standard deviation of about 0.5% in annual value which is worth about 1.3 M$ per annum), and an economic model to evaluate the profitability of such a project. We thus discuss the existing challenges of diversifying renewable energy sources in Israel by adding wind installations. Our motivation is to introduce a method which will allow investors and officials to take into account uncertainties when deciding in investing in such wind installations. The outcomes of the paper, which are obtained using the method of Weibull statistics and the Black–Scholes ROA technique, include the result that market price volatility adds to the uncertainties much more than any wind fluctuations, provided that the analysis is integrated over a long enough time.

17 WIND ENERGY↗

Reducing the Flow Maldistribution in Heat Exchangers through a Novel Polymer Manifold: Numerical Evaluation

The maldistribution of working fluid is one of the issues in heat exchangers that causes a reduction in performance of not only the heat exchanger but also the entire HVAC system. One of the methods to reduce such maldistribution is to improve manifold design to evenly distribute the flow. In the present work, an advanced maldistribution reduction manifold, which was based on a preliminary maldistribution reduction manifold, was designed to further improve the flow distribution in the heat exchanger. In the design, spiral baffles are used to create vortices in the tubes to regulate the flow in each tube. The design also keeps the tubes away from the manifold inlet to avoid direct flow from the inlet. Due to the complexity, the design of the advanced maldistribution reduction manifold is for AM only, which cannot be fabricated by traditional manufacturing. To evaluate the design, a computational fluid dynamic model is developed to study flow distribution in heat exchanger manifolds. The simulation results reveal that the relative standard deviation of the tubes in the advanced maldistribution reduction design is half of the preliminary maldistribution reduction design and about 1/20 of the reference design.

42 ENGINEERING↗

Robust real-time change detection in high jitter.

A new method is introduced for real-time detection of transient change in scenes observed by staring sensors that are subject to platform jitter, pixel defects, variable focus, and other real-world challenges. The approach uses flexible statistical models for the scene background and its variability, which are continually updated to track gradual drift in the sensor's performance and the scene under observation. Two separate models represent temporal and spatial variations in pixel intensity. For the temporal model, each new frame is projected into a low-dimensional subspace designed to capture the behavior of the frame data over a recent observation window. Per-pixel temporal standard deviation estimates are based on projection residuals. The second approach employs a simple representation of jitter to generate pixelwise moment estimates from a single frame. These estimates rely on spatial characteristics of the scene, and are used gauge each pixel's susceptibility to jitter. The temporal model handles pixels that are naturally variable due to sensor noise or moving scene elements, along with jitter displacements comparable to those observed in the recent past. The spatial model captures jitter-induced changes that may not have been seen previously. Change is declared in pixels whose current values are inconsistent with both models.

47 OTHER INSTRUMENTATION↗

SU-D-BRE-03: Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy

Purpose: To quantitatively evaluate dosimetric consequence of spot size variations and validate beam-matching criteria for commissioning a pencil beam model for multiple treatment rooms. Methods: A planning study was first conducted by simulating spot size variations to systematically evaluate dosimetric impact of spot size variations in selected cases, which was used to establish the in-air spot size tolerance for beam matching specifications. A beam model in treatment planning system was created using in-air spot profiles acquired in one treatment room. These spot profiles were also acquired from another treatment room for assessing the actual spot size variations between the two treatment rooms. We created twenty five test plans with targets of different sizes at different depths, and performed dose measurement along the entrance, proximal and distal target regions. The absolute doses at those locations were measured using ionization chambers at both treatment rooms, and were compared against the calculated doses by the beam model. Fifteen additional patient plans were also measured and included in our validation. Results: The beam model is relatively insensitive to spot size variations. With an average of less than 15% measured in-air spot size variations between two treatment rooms, the average dose difference was −0.15% with a standard deviation of 0.40% for 55 measurement points within target region; but the differences increased to 1.4%±1.1% in the entrance regions, which are more affected by in-air spot size variations. Overall, our single-room based beam model in the treatment planning system agreed with measurements in both rooms < 0.5% within the target region. For fifteen patient cases, the agreement was within 1%. Conclusion: We have demonstrated that dosimetrically equivalent machines can be established when in-air spot size variations are within 15% between the two treatment rooms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary Statistics for Fun Dough Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a Play Dough{trademark}-like product, Fun Dough{trademark}, designated as PD. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2100 LMHU{sub D} at 100kVp to a low of about 1100 LMHU{sub D} at 300kVp. The standard deviation of each measurement is around 1% of the mean. The entropy covers the range from 3.9 to 4.6. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 8.5. LLNL prepared about 50mL of the Fun Dough{trademark} in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. Still, layers can plainly be seen in the reconstructed images, indicating that the bulk density of the material in the container is affected by voids and bubbles. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗