Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Earth Mover’s Distance as a Metric to Evaluate the Extent of Charge Transfer in Excitations Using Discretized Real-Space Densities

This paper presents a novel theoretical measure, μ EMD , based on the earth mover's distance (EMD), for quantifying the density shift caused by electronic excitations in molecules. As input, the EMD metric uses only the discretized ground- and excited-state electron densities in real space, rendering it compatible with almost all electronic structure methods used to calculate excited states. The EMD metric is compared against other popular theoretical metrics for describing the extent of electron-hole separation in a wide range of excited states (valence, Rydberg, charge transfer, etc.). Further, the results showcase the EMD metric's effectiveness across all excitation types and suggest that it is useful as an additional tool to characterize electronic excitations. The study also reveals that μ EMD can function as a promising diagnostic tool for predicting the failure of pure exchange-correlation functionals. Specifically, we show statistical relationships among the functional-driven errors, the exact exchange content within the functional, and the magnitude of μ EMD values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying the Variation in the Number of Donors in Quantum Dots Created Using Atomic Precision Advanced Manufacturing

Atomic-precision advanced manufacturing enables unique silicon quantum electronics built on quantum dots fabricated from small numbers of phosphorus dopants. The number of dopant atoms comprising a dot plays a central role in determining the behavior of charge and spin confined to the dots and thus overall device performance. Here in this work, we use both theoretical and experimental techniques to explore the combined impact of lithographic variation and stochastic kinetics on the number of P incorporations in quantum dots made using these techniques and how this variation changes as a function of the size of the dot. Using a kinetic model of PH3 dissociation augmented with novel reaction barriers, we demonstrate that for a 2 × 3 silicon dimer window the probability that no donor incorporates goes to zero, allowing for certainty in the placement of at least one donor. However, this still comes with some uncertainty in the precise number of incorporated donors (either one or two), and this variability may still impact certain applications. We also examine the impact of the size of the initial lithographic window, finding that the incorporation fraction saturates to δ-layer-like coverage as the circumference-to-area ratio decreases. We predict that this incorporation fraction depends strongly on the dosage of the precursor and that the standard deviation of the number of incorporations scales as ~√n, as would be expected for a sequence of largely independent incorporation events. Finally, we characterize an array of 36 experimentally prepared multidonor 3 × 3 nm lithographic windows with scanning tunneling microscopy, measuring the fidelity of the lithography to the desired array and the final location of PH x fragments within these lithographic windows. We use our kinetic model to examine the expected variability due to the observed lithographic error, predicting a negligible impact on incorporation statistics. We find good agreement between our model and the inferred incorporation locations in these windows from scanning tunneling microscope measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regularized machine learning on molecular graph model explains systematic error in DFT enthalpies

Abstract A major goal of materials research is the discovery of novel and efficient heterogeneous catalysts for various chemical processes. In such studies, the candidate catalyst material is modeled using tens to thousands of chemical species and elementary reactions. Density Functional Theory (DFT) is widely used to calculate the thermochemistry of these species which might be surface species or gas-phase molecules. The use of an approximate exchange correlation functional in the DFT framework introduces an important source of error in such models. This is especially true in the calculation of gas phase molecules whose thermochemistry is calculated using the same planewave basis set as the rest of the surface mechanism. Unfortunately, the nature and magnitude of these errors is unknown for most practical molecules. Here, we investigate the error in the enthalpy of formation for 1676 gaseous species using two different DFT levels of theory and the ‘ground truth values’ obtained from the NIST database. We featurize molecules using graph theory. We use a regularized algorithm to discover a sparse model of the error and identify important molecular fragments that drive this error. The model is robust to rigorous statistical tests and is used to correct DFT thermochemistry, achieving more than an order of magnitude improvement.

36 MATERIALS SCIENCE↗

RANDOM FORESTS FOR PHOTOMETRIC REDSHIFTS

The main challenge today in photometric redshift estimation is not in the accuracy but in understanding the uncertainties. We introduce an empirical method based on Random Forests to address these issues. The training algorithm builds a set of optimal decision trees on subsets of the available spectroscopic sample, which provide independent constraints on the redshift of each galaxy. The combined forest estimates have intriguing statistical properties, notable among which are Gaussian errors. We demonstrate the power of our approach on multi-color measurements of the Sloan Digital Sky Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Lyman-{alpha} constraints on warm and on warm-plus-cold dark matter models

We revisit Lyman-{alpha} bounds on the dark matter mass in {Lambda} Warm Dark Matter ({Lambda}WDM) models, and derive new bounds in the case of mixed Cold plus Warm models ({Lambda}CWDM), using a set up which is a good approximation for several theoretically well-motivated dark matter models. We combine WMAP5 results with two different Lyman-{alpha} data sets, including observations from the Sloan Digital Sky Survey. We pay a special attention to systematics, test various possible sources of error, and compare the results of different statistical approaches. Expressed in terms of the mass of a non-resonantly produced sterile neutrino, our bounds read m{sub NRP} {>=} 8 keV (frequentist 99.7% confidence limit) or m{sub NRP} {>=} 12.1 keV (Bayesian 95% credible interval) in the pure {Lambda}WDM limit. For the mixed model, we obtain limits on the mass as a function of the warm dark matter fraction F{sub WDM}. Within the mass range studied here (5 keV < m{sub NRP} < {infinity}), we find that any mass value is allowed when F{sub WDM} < 0.6 (frequentist 99.7% confidence limit); similarly, the Bayesian joint probability on (F{sub WDM}, 1/m{sub NRP}) allows any value of the mass at the 95% confidence level, provided that F{sub WDM} < 0.35.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of Telescope Transmission Using a Collimated Beam Projector

With the increasingly large number of Type Ia supernova being detected by current-generation survey telescopes, and even more expected with the upcoming Rubin Observatory Legacy Survey of Space and Time, the precision of cosmological measurements will become limited by systematic uncertainties in flux calibration rather than statistical noise. One major source of systematic error in determining SNe Ia color evolution (needed for distance estimation) is uncertainty in telescope transmission, both within and between surveys. We introduce here the Collimated Beam Projector (CBP), which is meant to measure a telescope transmission with collimated light. The collimated beam more closely mimics a stellar wave front as compared to flat-field-based instruments, allowing for more precise handling of systematic errors such as those from ghosting and filter angle-of-incidence dependence. As a proof of concept, we present CBP measurements of the StarDICE prototype telescope, achieving a standard (1σ) uncertainty of 3% on average over the full wavelength range measured with a single beam illumination.

79 ASTRONOMY AND ASTROPHYSICS↗

Prediction of Regulation Reserve Requirements in California ISO Control Area based on BAAL Standard

This paper presents new methodologies developed at Pacific Northwest National Laboratory (PNNL) to estimate regulation capacity requirements in the California ISO control area. Two approaches have been developed: (1) an approach based on statistical analysis of actual historical area control error (ACE) and regulation data, and (2) an approach based on balancing authority ACE limit control performance standard. The approaches predict regulation reserve requirements on a day-ahead basis including upward and downward requirements, for each operating hour of a day. California ISO data has been used to test the performance of the proposed algorithms. Results show that software tool allows saving up to 30% on the regulation procurements cost .

Etingov, Pavel V.↗

Prediction of Power System Balancing Requirement and Tail Event

This paper presents a methodology for the prediction of power system balancing requirement and the probability of tail event (large imbalance between generation and load). Maintaining sufficient balancing reserves to match the difference between hourly generation schedule and real-time variable load and intermittent resources, becomes more and more challenging with the increasing penetration of intermittent energy sources. The presented methodology uses a yearly distribution and an hourly distribution of balancing requirement and tail events to provide a high level look at the issue and warn system operators of those hours when problems are most likely to occur. For real-time prediction, a Bayes Net model is constructed to model the statistical relationships between system imbalance and forecast errors, generation schedule control errors and other influential factors. The methodology will be able to provide reference information to system operators in determining the sufficiency of system balancing reserve and taking appropriate control actions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MO-FG-303-03: Demonstration of Universal Knowledge-Based 3D Dose Prediction

Purpose: To demonstrate a knowledge-based 3D dose prediction methodology that can accurately predict achievable radiotherapy distributions. Methods: Using previously treated plans as input, an artificial neural network (ANN) was trained to predict 3D dose distributions based on 14 patient-specific anatomical parameters including the distance (r) to planning target volume (PTV) boundary, organ-at-risk (OAR) boundary distances, and angular position ( θ,φ). 23 prostate and 49 stereotactic radiosurgery (SRS) cases with ≥1 nearby OARs were studied. All were planned with volumetric-modulated arc therapy (VMAT) to prescription doses of 81Gy for prostate and 12–30Gy for SRS. Site-specific ANNs were trained using all prostate 23 plans and using a 24 randomly-selected subset for the SRS model. The remaining 25 SRS plans were used to validate the model. To quantify predictive accuracy, the dose difference between the clinical plan and prediction were calculated on a voxel-by-voxel basis δD(r,θ,φ)=Dclin(r,θ,φ)-Dpred(r, θ,φ). Grouping voxels by boundary distance, the mean <δ Dr>=(1/N)Σ -θ,φ D(r,θ,φ) and inter-quartile range (IQR) quantified the accuracy of this method for deriving DVH estimations. The standard deviation (σ) of δ D quantified the 3D dose prediction error on a voxel-by-voxel basis. Results: The ANNs were highly accurate in predictive ability for both prostate and SRS plans. For prostate, <δDr> ranged from −0.8% to +0.6% (max IQR=3.8%) over r=0–32mm, while 3D dose prediction accuracy averaged from σ=5–8% across the same range. For SRS, from r=0–34mm the training set <δDr> ranged from −3.7% to +1.5% (max IQR=4.4%) while the validation set <δDr> ranged from −2.2% to +5.8% (max IQR=5.3%). 3D dose prediction accuracy averaged σ=2.5% for the training set and σ=4.0% over the same interval. Conclusion: The study demonstrates this technique’s ability to predict achievable 3D dose distributions for VMAT SRS and prostate. Future investigations will attempt to separate and quantify modeling error and plan quality variations in the statistical noise. Research funding support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Search for a heavy neutral particle decaying into an electron and a muon using 1 fb &#x2212; 1 of ATLAS data

CERN-LHC. A search for high mass neutral particles that decay directly into oppositely charged electron-muon pairs produced in proton-proton collisions at a centre-of-mass energy of 7 TeV. The analysis uses a data sample of total integrated luminosity of 1.07 fb-1 and the results are found to be consistent with the Standard Model expectations. The high di-lepton mass region is used to set upper limits on the production of two possible new physics processes: tau sneutrinos in an R-parity violating SUSY model and Zprime like vector bosons in a lepton flavour violating model. In the tables the errors on the data points are purely statistical and can therefore be derived from the total number of events observed in each bin. The auxillary plots refered to in several of the tables are available on the ATLAS web site: atlas.web.cern.ch/Atlas/GROUPS/PHYSICS/PAPERS/SUSY-2011-11/.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the Diffusivity Predictions of Centipede Using Approximate Bayesian Computation and Applications in Nyx (Engineering Scale) and Xolotl-MARMOT (Meso-Scale) Simulations

Fission gas evolution and release in UO 2 nuclear fuel are important fuel performance metrics and occur in several distinct stages: 1) nucleation, growth and resolution of intra-granular bubbles, 2) diffusion to grain boundaries and 3) nucleation and growth of bubbles at grain boundaries, which eventually form a connected network (percolation) enabling release of gas from grain boundaries through connections to triple junctions, grain edges or free surfaces. The NE-SciDAC project is developing several computational tools to model this problem, which are connected in a hierarchical multi-scale framework. The information transfer in the multi-scale framework is a critical step that, in addition to best-estimates, should include uncertainty quantification. Despite taking a first-principles multi-scale approach, there is a need to perform parameter calibration to ensure consistency with available experimental data. In the present study, uncertainty quantification (UQ) and parameter calibration is demonstrated for one of the lower length scale codes in the multi-scale framework (Centipede) and then the results, including instances of the propagated uncertainties, are used in other codes within the framework, specifically Nyx and Xolotl-MARMOT. We calibrated the model parameters in Centipede, a computer code used to predict diffusivities of uranium (U) and xenon (Xe) in the context of the simulation of fission gas in uranium oxide (UO 2 ) nuclear fuel. The Centipede code depends on 183 parameters, all of which are subject to uncertainty. The three data sets used in our calibration effort are taken from the literature. This data is available as a set of measurements, including measurement errors. Our goal is to calibrate a statistical model that predicts both the value of the measurement and the uncertainty associated with the measurement. We perform a Bayesian calibration of the model parameters using a dedicated approximate Bayesian computation (ABC) likelihood function. To avoid excessive computational costs, we replace the expensive Centipede simulation code by a higher-order surrogate model, constructed using only the 9 most important parameters. These important parameters are identified by a preliminary global sensitivity analysis (GSA) study. Among the important parameters are T0 (the temperature at which UO 2 is perfectly stoichiometric) and Hf_pO2 (the temperature dependence of the oxygen (O) partial pressure) that should be considered as operating conditions to be estimated along with the other parameters. We consider two different cases: one where we define one set of these operating conditions for all data sets, and one where we define distinct operating condition parameters for each data set. The Xe diffusivities predicted by the latter case show distinct features that could not be observed in the former. Next, we use the diffusivity predictions by Centipede as input to Nyx, a reduced order fuel performance code focused on gas behavior alone, in order to estimate quantities associated with inter-granular bubble formation at conditions specified by the experiments. Finally, the diffusivities obtained from the calibrated Centipede runs were used in coupled Xolotl-MARMOT simulations of intra- and inter-granular gas evolution. The results are compared to simulations using the baseline diffusivities from Turnbull et al.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration and Commissioning of the LSST

Understanding the nature of dark energy and dark matter remains one of the fundamental questions in physics today; impacting our understanding of particle physics, cosmology, and possibly theories of gravity. Given the scale and complexity of the next generation of cosmology experiments (e.g., the Rubin Observatory, the Euclid satellite mission, and the Roman space telescope) we are entering an era where statistical noise no longer determines the accuracy to which we can measure cosmological parameters. Our ability to control and correct for systematics will ultimately determine the scientific impact of these experiments. This award addressed the challenge of how we determine what limits the accuracy of our cosmological measures, what techniques are appropriate for measuring and calibrating the properties of galaxies to best constrain cosmological models, how to develop statistical techniques that are insensitive to systematic errors, and how to optimize survey strategies in order to minimize systematics while maximizing the speed at which an experiment can achieve its science objectives. In this final technical report for award DE-SC0011635 we describe a set of open-source frameworks that simulate the characteristics and properties of current and planned cosmology surveys and the application of these frameworks to the development of new methodologies for estimating the properties and distances to galaxies that are robust to noisy and incomplete data.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

Mass Calibration of Optically Selected DES Clusters Using a Measurement of CMB-cluster Lensing with SPTpol Data

We use cosmic microwave background (CMB) temperature maps from the 500 deg$^{2}$ SPTpol survey to measure the stacked lensing convergence of galaxy clusters from the Dark Energy Survey (DES) Year-3 redMaPPer (RM) cluster catalog. The lensing signal is extracted through a modified quadratic estimator designed to be unbiased by the thermal Sunyaev-Zel{'}dovich (tSZ) effect. The modified estimator uses a tSZ-free map, constructed from the SPTpol 95 and 150 GHz datasets, to estimate the background CMB gradient. For lensing reconstruction, we employ two versions of the RM catalog: a flux-limited sample containing 4003 clusters and a volume-limited sample with 1741 clusters. We detect lensing at a significance of 8.7$\sigma$(6.7$\sigma$) with the flux(volume)-limited sample. By modeling the reconstructed convergence using the Navarro-Frenk-White profile, we find the average lensing masses to be $M_{200m}$ = ($1.62^{+0.32}_{-0.25}$ [stat.] $\pm$ 0.04 [sys.]) and ($1.28^{+0.14}_{-0.18}$ [stat.] $\pm$ 0.03 [sys.]) $\times\ 10^{14}\ M_{\odot}$ for the volume- and flux-limited samples respectively. The systematic error budget is much smaller than the statistical uncertainty and is dominated by the uncertainties in the RM cluster centroids. We use the volume-limited sample to calibrate the normalization of the mass-richness scaling relation, and find a result consistent with the galaxy weak-lensing measurements from DES.

79 ASTRONOMY AND ASTROPHYSICS↗

Xanthos-Lake Dataset

The Xanthos-Lake v1.0 dataset provides the input data, trained machine-learning models, and simulation outputs needed to characterize lake water balance, snow and ice conditions, and mixing-layer temperature within the Xanthos global hydrological modeling framework. The dataset supports lake representation across a wide range of lake sizes and hydroclimatic conditions by combining xLSIM, a basin-specific machine-learning emulator of lake snow, ice, ice-cover fraction, and mixing-layer temperature, with the Xanthos-Lake water-balance model. The archive contains NetCDF datasets used to train and evaluate xLSIM, trained model weights, processed meteorological and lake-property inputs, and basin- and lake-category-specific simulation outputs. These materials are organized into four primary data groups, described below. Snowice_model_inputs: Contains the NetCDF input data used to train xLSIM. The xLSIM machine-learning framework uses three lake-based datasets. The meteorological forcing dataset provides monthly relative humidity, specific humidity, surface wind speed, maximum and minimum air temperature, downward longwave and shortwave radiation, snowfall, surface air pressure, and total precipitation. Lake surface area is included as an additional static predictor. The target-state dataset provides lake ice thickness, snow depth, snow cover, and lake mixing-layer temperature, while a companion lake-surface dataset provides the lake ice-cover fraction. Before training, ice thickness and snow depth are converted from meters to centimeters, mixing-layer temperature is converted from kelvin to degrees Celsius and constrained to nonnegative values, and ice-cover fraction is converted from a fraction to a percentage. The predictor variables are normalized using statistics calculated across the selected lakes and time steps. Snowice_model_outputs: Contains the NetCDF outputs generated by xLSIM. For each basin, xLSIM produces a file containing observed and predicted lake-state variables for the training, validation, and testing periods. The modeled variables include lake ice thickness, snow depth, snow cover, mixing-layer temperature, and lake ice-cover fraction. For basins without a sufficiently persistent snow-and-ice signal, the emulator predicts only mixing-layer temperature. The outputs also include training and validation loss histories, the selected model configuration, identifiers of the lakes used in training, and SHAP-based feature-importance information at the global, lake, and seasonal-regime levels. The trained machine-learning model weights are provided separately within the dataset archive. Together, these files support model evaluation and subsequent coupling with the Xanthos-Lake water-balance framework. XanthosLAKES: Contains the NetCDF input data used by the Xanthos-Lake framework. Monthly meteorological inputs include relative and specific humidity, downward shortwave and longwave radiation, mean, maximum, and minimum air temperature, wind speed, precipitation, snowfall, and surface air pressure. Static lake-property datasets provide lake identifiers, geographic locations, surface area, volume, mean depth, elevation, drainage area, fetch, outlet-routing information, and associated Xanthos grid-cell attributes. Separate bathymetric datasets provide the coefficients of the area–depth and volume–depth relationships for each aggregated lake unit. GLEV-based records provide observed lake surface area and evaporation data used to initialize lake states, define reference conditions, and calibrate and evaluate the model. Xanthos-Lake Outputs: Contains the basin- and lake-category-specific NetCDF outputs generated by Xanthos-Lake. Monthly variables include lake surface area, storage volume, outlet discharge, evaporation rate, evaporation volume, lake–groundwater exchange, lake inflow, ice thickness, snow depth, snow-cover fraction, ice-cover fraction, and mixing-layer temperature. The files also contain lake-specific calibration and validation statistics, including normalized root-mean-square error, mean absolute error, Nash–Sutcliffe efficiency, Kling–Gupta efficiency, and percent bias. Stored calibrated and derived parameters include the weir discharge coefficient, fractional freeboard, groundwater exchange coefficient, reference water level, corresponding reference surface area and storage volume, weir-width adjustment factor, and the fraction of routed inflow entering the lake. Basin identifiers, lake category, simulation period, calibration and validation periods, and parameter-schema information are retained as NetCDF metadata.

Abeshu, Guta [Pacific Northwest National Laborator↗

Fundamental limitations of high contrast imaging set by small sample statistics

In this paper, we review the impact of small sample statistics on detection thresholds and corresponding confidence levels (CLs) in high-contrast imaging at small angles. When looking close to the star, the number of resolution elements decreases rapidly toward small angles. This reduction of the number of degrees of freedom dramatically affects CLs and false alarm probabilities. Naively using the same ideal hypothesis and methods as for larger separations, which are well understood and commonly assume Gaussian noise, can yield up to one order of magnitude error in contrast estimations at fixed CL. The statistical penalty exponentially increases toward very small inner working angles. Even at 5-10 resolution elements from the star, false alarm probabilities can be significantly higher than expected. Here we present a rigorous statistical analysis that ensures robustness of the CL, but also imposes a substantial limitation on corresponding achievable detection limits (thus contrast) at small angles. This unavoidable fundamental statistical effect has a significant impact on current coronagraphic and future high-contrast imagers. Finally, the paper concludes with practical recommendations to account for small number statistics when computing the sensitivity to companions at small angles and when exploiting the results of direct imaging planet surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Short-Term Precipitation Forecast Based on the PERSIANN System and LSTM Recurrent Neural Networks

Short-term Quantitative Precipitation Forecasting is important for flood forecasting, early flood warning, and natural hazard management. This study proposes a precipitation forecast model by extrapolating Cloud-Top Brightness Temperature (CTBT) using advanced Deep Neural Networks, and applying the forecasted CTBT into an effective rainfall retrieval algorithm to obtain the Short-term Quantitative Precipitation Forecasting (0–6 hr). To achieve such tasks, we propose a Long Short-Term Memory (LSTM) and the Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks (PERSIANN), respectively. The precipitation forecasts obtained from our proposed framework, (i.e., LSTM combined with PERSIANN) are compared with a Recurrent Neural Network (RNN), Persistency method, and Farneback optical flow each combined with PERSIANN algorithm and the numerical model results from the first version of Rapid Refresh (RAPv1.0) over three regions in the United States, including the states of Oregon, Oklahoma, and Florida. We report our experiments indicate better statistics, such as correlation coefficient and root-mean-square error, for the CTBT forecasts from the proposed LSTM compared to the RNN, Persistency, and the Farneback method. The precipitation forecasts from the proposed LSTM and PERSIANN framework has demonstrated better statistics compared to the RAPv1.0 numerical forecasts and PERSIANN estimations from RNN, Persistency, and Farneback projections in terms of Probability of Detection, False Alarm Ratio, Critical Success Index, correlation coefficient, and root-mean-square error, especially in predicting the convective rainfalls. The proposed method shows superior capabilities in short-term forecasting over compared methods, and has the potential to be implemented globally as an alternative short-term forecast product.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗