Search NASA⌕ Search

SEARCH · Search NASA

Results for “THICKNESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

SU-E-T-271: Direct Measurement of Tenth Value Layer Thicknesses for High Density Concretes with a Clinical Machine

Purpose: Use of high density concrete for radiation shielding is increasing, trading cost for space savings associated with the reduced tenth value layer (TVL). Precise information on the attenuation properties of high-density concretes is not readily present in the literature. A simple approximation is to scale the TVLs from NCRP 151 according relative increase in density. Here we present measured TVLs for heavy concretes of various densities using a built-in shielding test port. Methods: Concrete densities tested range from 2.35 g cc{sup −1} (147 pcf) to 5.6 g cc{sup −1} (350 pcf). Measurements were taken using 6MV, 6FFF, and 10FFF on a Varian Truebeam linear accelerator. Field sizes of 4x4, 9x9 and 30x30 cm{sup 2} were measured. A PTW 31013 Farmer chamber with a buildup cap was positioned 5.5 m from isocenter along the beam CAX. Concrete thicknesses were incremented in 5 cm intervals. Comparison TVLs were determined by scaling the NCRP 151 TVLs by the density ratio between the sample and standard density. Results: The trend from the first to equilibrium TVL was an increase in thickness, compared with MC modeling, which predicted a decrease. Measured TVLs for 6 MV were reduced by as much as 8.9 cm for TVL{sub 1} and 3.4 cm for TVL{sub E} compared to values scaled from NCRP 151. There was 1–3 mm difference in TVL between measurements done at 4x4 versus 30x30 cm{sup 2}. TVL{sub 1} for 6FFF was 1.1 cm smaller than TVL{sub 1} for 6MV, but TVL{sub E} was consistent to within 4 mm. TVL{sub 1} and TVL{sub E} for 10FFF were reduced by 8.8 and 3.7 cm from scaled NCRP values, respectively. Conclusions: We have measured the TVL thicknesses for various concretes. Simple density scaling of the values in NCRP 151 is a conservatively safe approximation, but actual TVLs may be reduced enough to eliminate some of the expense of installation. Daniel Harrell and Jim Noller are employees of Shielding Construction Solutions, Inc, the shielding construction company that built the vault discussed in this abstract. Manjit Chopra is an employee of Universal Minerals International, Inc, the company that provided the aggregates for the high density concretes used in the vault construction.

43 PARTICLE ACCELERATORS↗

Distribution of germanium in Si{sub 1-x}Ge{sub x} (x < 0.1) layers grown on the Si(001) substrate as a function of layer thickness

The germanium distribution in Si(001)/Si{sub 1-x}Ge{sub x} layers as a function of the layer thickness at a low dopant concentration (x < 6%) has been investigated using high-resolution X-ray diffractometry and low-temperature photoluminescence. It has been shown that the germanium concentration increases with increasing thickness of the SiGe layer with the formation of lateral inhomogeneities at the boundary between this layer and a silicon cap layer for a layer thickness of 30 nm or more. These inhomogeneities have an oriented character and give rise to anisotropic diffuse scattering for the system of (113) and (224) asymmetric reflections from SiGe. The luminescence of these films at low temperatures and low excitation densities is an emission of localized and delocalized excitons, which is characteristic of systems with disorder. The revealed nonuniform germanium distribution in the lateral direction is associated with the accumulation of germanium in the near-surface SiGe layer and with the partial relaxation of elastic strains due to the development of surface roughness and the preferred incorporation of germanium atoms into one side of the surface ripples.

36 MATERIALS SCIENCE↗

The role of AlGaN buffers and channel thickness in the electronic transport properties of Al{sub x}In{sub 1–x}N/AlN/GaN heterostructures

We try to theoretically analyze the reported experimental data of the Al{sub x}In{sub 1–x}N/AlN/GaN heterostructures grown by MOCVD and quantitatively investigate the effects of AlGaN buffers and the GaNchannel thickness on the electrical transport properties of these systems. Also, we obtain the most important effective parameters of the temperature-dependent mobility in the range 35–300 K. Our results show that inserting a 1.1 μm thick Al{sub 0.04}Ga{sub 0.96}N buffer enhances electron mobility by decreasing the effect of phonons, the interface roughness, and dislocation and crystal defect scattering mechanisms. Also, as the channel thickness increases from 20 nm to 40 nm, the electron mobility increases from 2200 to 2540 cm{sup 2}/(V s) and from 870 to 1000 cm{sup 2}/(V s) at 35 and 300 K respectively, which is attributed to the reduction in the dislocation density and the strain-induced field. Finally, the reported experimental data show that inserting a 450 nm graded AlGaN layer before an Al{sub 0.04}Ga{sub 0.96}N buffer causes a decrease in the electron mobility, which is attributed to the enhancement of the lateral size of roughness, the dislocation density, and the strain-induced field in this sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of the active region thickness on characteristics of semiconductor lasers based on asymmetric AlGaAs/GaAs/InGaAs heterostructures with broadened waveguide

The effect of the active region thickness on the basic characteristics of high-power semiconductor lasers based on AlGaAs/GaAs/InGaAs asymmetric separate-confinement heterostructures grown by MOCVD epitaxy has been studied. It is shown that the threshold current, temperature sensitivity of the threshold current density, internal quantum efficiency of stimulated emission, and differential quantum efficiency are improved as the active region thickness increases. It is demonstrated that the maximum attainable optical emission power of a semiconductor laser and the internal quantum efficiency of photoluminescence are the most sensitive to defect formation in the heterostructure and become lower as the critical thickness of the strained In{sub x}Ga{sub 1-x} As layer in the active region is exceeded.

36 MATERIALS SCIENCE↗

Determination of the thickness and spectral dependence of the refractive index of Al{sub x}In{sub 1-x}Sb epitaxial layers from reflectance spectra

A nondestructive method for measuring the thicknesses of epitaxial layers of Al{sub x}In{sub 1-x}Sb alloys based on interference effects in reflectance spectra measured in a wide wavelength range (1-28 {mu}m) is implemented. The studied 0.9-3.3 {mu}m thick Al{sub x}In{sub 1-x}Sb layers are grown on highly lattice-mismatched GaAs substrates by molecular beam epitaxy. The found thicknesses are in good agreement with the independent data of scanning electron microscopy. The spectral dependence of the refractive index n(E) of Al{sub x}In{sub 1-x}Sb layers is measured both for the regions of transparency and fundamental absorption. The refractive index for the case of E < E{sub 0} was calculated by a double-oscillator model using a refined experimental dependence of the band gap on the composition E{sub 0}(x). The experimental data on the n(E) of Al{sub x}In{sub 1-x}Sb for energies E > E{sub 0} are found based on the interference pattern.

36 MATERIALS SCIENCE↗

Investigation of Composition Uniformity in Thickness of GaInAsP Layers Grown on InP Substrates by Vapor-Phase Epitaxy

GaInPAs/InP heterostructures grown by metalorganic chemical vapor-phase deposition at a temperature of 600°C and pressure of 0.1 bar are investigated. The thicknesses of the grown GaInAsP layers amount to about 1 μm. For Ga{sub 1 –x}In{sub x}P{sub 1 –y}As{sub y} solid solutions with average compositions of x = 0.77–0.87 and y = 0.07–0.42, the variation in the content y of V-group atoms over the epitaxial-layer thickness by a value of Δy up to 0.1 atomic fractions in the sublattice of the V-group elements is revealed by secondary ion mass spectrometry. In most cases, a change in y occurs in the GaInAsP layer over a length to 200 nm from the InP heterointerface. In certain cases, y varies throughout the entire GaInPAs-layer thickness. For the epitaxial layers with satisfactory crystalline perfection, the value of Δy is less in the case of better lattice-matching between the GaInPAs epitaxial layer and the substrate. For GaInPAs layers strongly lattice-mismatched with the substrate and characterized by a low degree of crystalline perfection, the value of Δy is close to zero. All these facts enable us to assume that it is elastic deformations arising in the forming monolayer lattice-mismatched with the growing surface that affect the incorporation of V-group atoms into the forming crystalline lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Effect of the Fin Shape and Thickness of the Buried Oxide on the DIBL Effect in an SOI FinFET

In this paper, we simulated the dependence of the effect of reducing the drain-induced barrier lowering on the thickness of a buried oxide layer in a finned (vertical) metal-oxide-semiconductor field effect transistor (FinFET) based on silicon-on-insulator technology. Three shapes of the fin with the rectangle, trapezoid, and triangle cross sections were considered. The drain-induced barrier lowering effect significantly depends on both the fin shape and the thickness of the buried oxide layer. The smallest drain-induced barrier lowering effect occurs when the thickness of the buried oxide layer is small for the fin of a triangular shape. This behavior of the drain-induced barrier lowering effect is strongly correlated with the behavior of the parasitic capacitance between a gate and a source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of Fresnel diffraction from a phase step to the measurement of film thickness

When a thin film that is prepared in a step form on a substrate and coated uniformly with a reflective material is illuminated by a parallel coherent beam of monochromatic light, the Fresnel diffraction fringes are formed on a screen perpendicular to the reflected beam. The visibility of the fringes depends on film thickness, angle of incidence, and light wavelength. Measuring visibility versus incident angle provides the film thickness with an accuracy of a few nanometers. The technique is easily applicable and it covers a wide range of thicknesses with highly reliable results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thickness measurement system for transparent plates using dual digital versatile disc (DVD) pickups

A low-cost high-precision thickness measurement system for transparent plates that uses dual digital versatile disc (DVD) pickups is proposed. The two DVD pickups are used as the transmitter and the receiver in the measurement system, respectively. One of the DVD pickups emits a laser to the other DVD pickup (receiver) and projects on the photodiode integrated circuit of the receiver. The transparent plate is placed in the optical path to change the focused point that will affect the focusing error signal (FES) of the receiver. Using the FES, a mathematical model for thickness measurement based on the geometric optical method is developed. The experimental results show that the accuracy is 1.5 {mu}m, and the uncertainty is estimated to be {+-}1.37 {mu}m for the measured thickness of 150{mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples

We investigated a high-precision optical method for measuring the thickness of biological samples regardless of their transparency. The method is based on the precise measurement of optical path length difference of the end surfaces of objects, using a dual-arm axial-scanning low-coherence interferometer. This removes any consideration of the shape, thickness, or transparency of testing objects when performing the measurement. Scanning the reference simplifies the measurement setup, resulting in unambiguous measurement. Using a 1310 nm wavelength superluminescent diode, with a 65 nm bandwidth, the measurement accuracy was as high as 11.6 {mu}m. We tested the method by measuring the thickness of both transparent samples and nontransparent soft biological tissues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soil thickness map at two hillslopes near the pumphouse in the east river watershed, Colorado

The soil thickness maps were created by using a hybrid model-data approach. Field sampling and remote sensing data of the spatial distribution of two hillslopes in the Pump House area in the East River Watershed in the CO., the U.S. The data package includes the geospatial data of the soil thickness maps at two hillslopes near the pumphouse, and the associated remote sensing data, including lidar DEM and a shape file of the boundary of the study area. The data can be viewed in GIS software such as QGIS or ArcGIS desktop. The geospatial data can also be viewed in Python or Matlab. The data were generated for the purpose of modeling surface hydrology and near-surface chemistry. This work shows how to combine sampling data and a process-based model to predict one of the highest uncertainty in the land surface process, the soil thickness.

2D Geospatial Maps↗

Effect of filter media thickness on the performance of sand drying beds used for faecal sludge management

Here the effect of sand filter media thickness on the performance of faecal sludge (FS) drying beds was determined in terms of: dewatering time, contaminant load removal efficiency, solids generation rate, nutrient content and helminth eggs viability in the dried sludge. A mixture of ventilated improved pit latrine sludge and septage in the ratio 1:2 was dewatered using three pilot-scale sludge drying beds with sand media thicknesses of 150, 250 and 350 mm. Five dewatering cycles were conducted and monitored for each drying bed. Although the 150 mm filter had the shortest average dewatering time of 3.65 days followed by 250 mm and 350 mm filters with 3.83 and 4.02 days, respectively, there was no significant difference (p > 0.05) attributable to filter media thickness configurations. However, there was a significant difference for the percolate contaminant loads in the removal and recovery efficiency of suspended solids, total solids, total volatile solids, nitrogen species, total phosphorus, chemical oxygen demand, dissolved chemical oxygen demand and biochemical oxygen demand, with the highest removal efficiency for each parameter achieved by the 350 mm filter. There were also significant differences in the nutrient content (NPK) and helminth eggs viability of the solids generated by the tested filters. Finally, filtering media configurations similar to 350 mm have the greatest potential for optimising nutrient recovery from FS.

54 ENVIRONMENTAL SCIENCES↗

Sea Ice Thickness, Freeboard, and Snow Depth products from Operation IceBridge Airborne Data

The study of sea ice using airborne remote sensing platforms provides unique capabilities to measure a wide variety of sea ice properties. These measurements are useful for a variety of topics including model evaluation and improvement, assessment of satellite retrievals, and incorporation into climate data records for analysis of interannual variability and long-term trends in sea ice properties. In this paper we describe methods for the retrieval of sea ice thickness, freeboard, and snow depth using data from a multisensor suite of instruments on NASA's Operation IceBridge airborne campaign. We assess the consistency of the results through comparison with independent data sets that demonstrate that the IceBridge products are capable of providing a reliable record of snow depth and sea ice thickness. We explore the impact of inter-campaign instrument changes and associated algorithm adaptations as well as the applicability of the adapted algorithms to the ongoing IceBridge mission. The uncertainties associated with the retrieval methods are determined and placed in the context of their impact on the retrieved sea ice thickness. Lastly, we present results for the 2009 and 2010 IceBridge campaigns, which are currently available in product form via the National Snow and Ice Data Center

sea ice thickness↗

Effects of the Thickness of Niobium Surface Oxide Layers on Field Emission

Field emission on the inner surfaces of niobium superconducting radio frequency cavities is still one of the major obstacles for reaching high accelerating gradients for SRF community. Our previous experimental results* seemed to imply that the threshold of field emission was related to the thickness of Nb surface oxide layers. In this contribution, a more detailed study on the influences of the surface oxide layers on the field emission on Nb surfaces will be reported. By anodization technique, the thickness of the surface pentoxide layer was artificially fabricated from 3 nm up to 460 nm. A home-made scanning field emission microscope was employed to perform the scans on the surfaces. Emitters were characterized using a scanning electron microscope together with an energy dispersive x-ray analyzer. The SFEM experimental results were analyzed in terms of surface morphology and oxide thickness of Nb samples and chemical composition and geographic shape of the emitters. A model based on the classic electromagnetic theory was developed trying to understand the experimental results. Possibly implications for Nb SRF cavity applications from this study will be discussed.

43 PARTICLE ACCELERATORS↗

Electron microscopy through micrometers thick water layers

Scanning transmission electron microscopy can be used to image specimens in water layers of several micrometers thickness, sufficiently thick to contain eukaryotic cells. We determined the resolution obtained on gold nanoparticles above and below water layers with thicknesses ranging from 1.3 13 m. The best achieved resolution values were 1.4 nm and 9 nm, above 3.3 m and below 1.3 m of water, respectively. A theoretical model included probe broadening and Monte Carlo simulations were developed to describe the resolution as function of the sample parameters.

99 GENERAL AND MISCELLANEOUS↗

Model-Independent Characterization of Charge Diffusion in Thick Fully Depleted CCDs

We present a new method to measure charge diffusion in charge-coupled devices (CCDs). The method is based on a statistical characterization of the shapes of charge clouds produced by low-energy X-rays using known properties of the two-dimensional Gaussian point-spread function (PSF). The algorithm produces reliable upper and lower bounds on the size of the PSF for photons converting near the entrance window of a device. It is optimally suited to the case of thick back-illuminated CCDs where the X-ray absorption length is smaller than the silicon thickness and the diffusion scale is of the same order as the pixel size. The only assumptions are that the charge cloud width is a monotonically increasing function of distance from the conversion point to the buried channel, and that the conversion probability is peaked at the surface. Otherwise, no physical models of carrier transport or knowledge of the electric field profile in the CCD are needed. In suboptimal conditions, the upper bound increases and the lower bound is unaffected, so confidence in the correctness of results is retained. The new method has been benchmarked against Monte Carlo simulations and tested on X-ray images measured on thick high-resistivity prototype CCDs for the Large Synoptic Survey Telescope. In Monte Carlo simulations of noiseless images having the optimal diffusion scale, the upper bound approximated the true PSF within 5%, increasing to 10% in simulations with added noise. Even with severely undersampled or truncated PSFs, the method brackets the true value to within 25%. Our method is accurate and computationally efficient and offers a fast and simple experimental setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Liquid-liquid interface assisted synthesis of size- and thickness-controlled Ag nanoplates

Here we proposed a synthetic method of high-purity Ag nanoplates by the reduction of aqueous Ag{sup +} ions at the aqueous-organic interface with the reductant ferrocene. We demonstrated that the as-prepared Ag nanoplates can be widely tunable from 600 nm to 7 {mu}m in size and from 10 to 35 nm in thickness, simply by adjusting the component of organic phase. To our knowledge, there are few methods to tailor the size and the thickness of metal nanoplates in such a large range although many efforts have been made aiming to realize it. Our proposed synthetic strategy is rapid, template-free, seed-less, and high-yield, and could be applied to synthesize analogous two-dimensional nanostructures of other noble metals, such as Pt, Au, and Pd. - Graphical abstract: High-purity Ag nanoplates were synthesized by the reduction of aqueous Ag{sup +} ions at the aqueous-organic interface with the reductant ferrocene, the size and thickness of which were widely tunable.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗