Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Development and Implementation of an Automatic Continuous Online Monitoring and Control Platform for Polymerization Reactions to Sharply Boost Energy and Resource Efficiency in Polymer Manufacturing

The project goal was to create an energy saving paradigm shift in how polymers are manufactured in the 21st century. It used Automatic Continuous Online Monitoring of Polymerization reactions (ACOMP) integrated for the first time with automatic active control to create the innovative ‘ACOMP/Control Interface’, or ‘ACOMP/CI’. ACOMP/CI will begin the transformation from old, inefficient processes into highly evolved, energy and resource efficient ones. The ACOMP platform is broadly applicable to many types of reactions and processes throughout the vast polymer industry. The industry provides materials for sectors such as automotive, aerospace, oil recovery, agriculture, paints, resins, adhesives, pharmaceuticals and therapeutic proteins, optics, electronics, lightweight building materials, and many more. The U.S. chemical industry is one of the last major sectors in which the U.S. has top global stature. It consumes 24% of all U.S. manufacturing energy, produces over $800B of product annually, supports 25% of the U.S. GDP and employs over 6 million people. It is also a major source of GHG emissions. Polymers make up approximately 30% of this sector. It is estimated that annually 60 TBtu of energy could be saved and 3 million tons less of GHG emissions produced by optimizing production in the polyolefin manufacturing sector alone. The project scope included first time design and prototyping of an ACOMP/CI, creation of active reaction controllers, and demonstration of control capabilities on ideal, low concentration polymerization reactions. All these elements of the scope were met, including advances and findings not originally anticipated. Extensions to more complex reactions, beyond the reactor capabilities of the current project ACOMP/CI, such as polyolefins and other high pressure/high temperature reactions, are being proposed in Fall 2017 to CESMII, a DoE based NNMI. The initial proposal was for a three year funded project, but this was reduced to a two year project and budget due to funding constraints. Hence, some of the original plans, such as adaptation of the ACOMP/CI to more relevant industrial processes, such as emulsion and dispersion technologies, could not be carried out. A third year of funding was requested at the end of the project, but DoE did not have resources to grant this. The sub-contractor Fluence Analytics (previously Advanced Polymer Monitoring Technologies, Inc) designed, prototyped, and commissioned a working ACOMP/CI by June 2015. The reaction characteristics to be automatically controlled were i) conversion kinetics, ii) molecular weight, iii) copolymer composition, and iv) simultaneous molecular weight and composition. A two pronged control strategy was used. The Tulane/Fluence group took a basic principles approach that did not rely on kinetic models. The LSU group took a more complex, non-linear model-oriented approach involving complete kinetic descriptions of the reaction system Each of these approaches proved successful in their own way. By April 2016 fully automatic control of conversion and weight average molecular weight, Mw, trajectories was achieved using the Tulane/Fluence (TF) basic principles controller. Similar results were obtained by the LSU non-linear model controller by August 2016. The demonstration system was aqueous free radical polymerization of acrylamide, Am. The control variables were temperature and semi-batch feed to the reactor of Am monomer and initiator. A demonstration of active manual conversion control in an industrial process using high solids in inverse emulsion polymerization of Am was achieved. During Summer 2016 the TF controller was used in conjunction with a chain transfer agent, another control variable, to automatically produce multi-modal molecular weight distributions, MWD, in a single reactor. Industrially, multi-modal MWD are produced by mixing products made in separate reactors, requiring significant extra time, energy, and reactor resources. Recognizing the industrial potential a patent on automatic production of multi-modal polymers was filed, and DoE acknowledged. In Fall 2016 the TF team developed a basic principles controller for copolymer composition and demonstrated it on aqueous free radical copolymerization of comonomers Am and styrene sulfonate, SS. TF then fused the Mw and composition controllers to achieve simultaneous control of both Mw and copolymer composition trajectories. Numerous simultaneous trajectories were demonstrated, including a trimodal composition distribution with constant Mw. Meanwhile, the LSU group developed a Kalman filter to improve the results of their automatic Mw and conversion controller and successful tests were made. During the project the TF team developed a means of computing full MWD during polymer synthesis without need for any chromatographic separation, based on model distributions. This means the polymer product is ‘born characterized’ and this can eliminate post-manufacture analytical laboratory quality control. TF filed a joint patent application on this new approach to chromatography-free determination of MWD with acknowledgment to DoE. The Tulane group obtained a 60MHz NMR during the project and recently completed the first work on separating three comonomers, Am, SS, and Na-acrylate, with a first demonstration of terpolymer composition control with the TF basic principles controller. Widespread dissemination of ACOMP/CI in the polymer manufacturing sector will bolster DoE goals of energy efficiency and reduced GHG emissions: The ability to monitor and actively control polymerization reactions will lead to more efficient use of energy and non-renewable resources, plant and labor time, increase the safety of manufacturing personnel, and will enhance product quality and lead to feasibility of manufacturing of polymers currently too complex for industrial scale production, while leading to less GHG emissions per kilo of product, and allowing for increased U.S. competitiveness in this enormous manufacturing sector. When ACOMP/CI is expanded to the polyolefin industry it is estimated that 60 TeraBTU/year of energy can be saved. Much of this saving is anticipated to come from optimized control of grade changeovers in steady state reactors and maintenance of steady states. Conclusions: ACOMP’s ability to provide continuous realtime data streams of measured polymer and reaction characteristics made it possible, for the first time, to directly and automatically control free radical polymerization reactions. An industrial client of Fluence Analytics has requisitioned the first ACOMP/CI which uses the TF basic principles controller. This sets the stage for FA to add control features to the ACOMP systems it has begun to install on the industrial scale beginning in 2014. Recommendations: This successful project was mainly limited to ideal polymerizations not of an industrial sort. The most energy intensive portion of polymer manufacturing is polyolefins. Adoption of ACOMP/CI to this enormous industrial sector faces the enormous challenges of high temperature, high pressure continuous sampling and high temperature sensor operation to obtain the continuous data needed for direct reaction control. The project team has a strategy for achieving this ambitious goal and will present it in Fall 2017 as a proposal to CESMII/DoE. It is recommended that this upcoming proposal be funded in order to make full use of the achievements of this just ended DoE project as the next step towards making polyolefin ACOMP/CI an energy saving reality. It is projected that ACOMP/CI can have its first polyolefin testbed demonstrations within two years of beginning the proposed project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas Final Technical Report

Exhaust control is critical for sustained and safe operation of magnetic confinement fusion (MCF), which requires bolometers to measure the radiations converted from the exhaust power. Traditional bolometers are based on a radiation absorber and a resistive temperature sensor and their performance is greatly compromised by the strong electromagnetic interference (EMI). Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. However, it shows relatively large noise that limits its usefulness in MCF applications. In this project, we reduced the noise by more than 20 times through novel sensor design and signal demodulation. The availability of such bolometers will help to better understand and control the exhaust control strategies in MCF. The original project duration was three years. Because the PI moved to another institution on 1/1/2018, the project was closed after four months and a new grant was awarded to the PI in his new institution to continue the work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Hydraulic Experimental Test Article: Status Report for FY2019

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, the secondary system in the 18-inch Test Vessel #6, and its sodium-to-air heat exchanger will occupy the location for 18-inch Test Vessel #5 (Test Vessel #5 will not be installed), Figure 2. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Status Report for FY2019 (Rev. 1)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Battery Monitoring System

The component that is powered by the battery pack being monitored is a valuable asset and must be in working condition at all times. Battery chemistry and characteristics have a major role in how to evaluate the state of the battery. The battery monitoring system has many parts that lead to an accurate battery reading. The components consist of a coulomb counting device, end of life voltage detection, a consideration of use for a real-time clock (RTC), temperature sensor, and non-volatile random-access memory (NVRAM). The combination of these elements allows the monitoring system to be highly reliant. Moving forward a better implementation of the ideas in this paper and further testing should ensure a high-quality battery monitoring system.

25 ENERGY STORAGE↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Hydraulic Experimental Test Article - Status Report FY20 Q2

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (like a redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed, most primary component have been fabricated, primary components are being assembled in preparation for initial testing, and procurement is continuing with the secondary system components. Since the FY19 THETA status report, The THETA primary system components are at Argonne National Laboratory (ANL) and have been dry assembled. The secondary sodium system for heat rejection from intermediate heat exchanger has all been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger has been procured.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of the Turbine Integrated Mortality Reduction (TIMR SM ) Technology as a Smart Curtailment Approach (Final Summary Report)

Wind energy is a crucial technology for achieving net-zero emissions by 2050. However, the growth and deployment of wind energy in North America have led to the deaths of many bat species due to operating wind turbines. Hundreds of thousands of bats are estimated to die at wind turbines annually in North America. Operational minimization, which includes feathering turbine blades and curtailment, has been documented to reduce bat fatality effectively. Curtailment refers to altering turbine operation based on wind speed, time of year, temperature, sensors, and activity models. However, when turbines are curtailed, they do not generate power, resulting in energy loss and revenue for wind energy facilities. The Electric Power Research Institute (EPRI) funded the development of Turbine Integrated Mortality Reduction (TIM SM ) Technology, which curtails turbine operation when bats are detected. The initial TIMR system research showed promising results, with an 85% reduction in overall bat fatalities and a 91% reduction for the little brown bat. However, these results were based on a single site during one fall season, and it was unclear if similar results could be replicated at other wind energy facilities. This research aimed to validate the TIMR system results from the prior field study at a second site in the U.S., estimate the power production and reduction in bat mortality at turbines with installed TIMR systems relative to blanket curtailment and fully operational turbines, test the TIMR system in two calendar years and during the summer and fall periods, and evaluate the operational and commercial characteristics of the TIMR system for potential wind industry adoption. The study was conducted at a 500.9-MW wind energy facility in southeast Adair County, Iowa. Three experimental treatments were involved in this randomized block design study: TIMR, Curtailment at 5.0 m/s, and Normal Operation. In 2021, three treatments were used at 18 turbines, expanding to four treatments across 36 turbines in 2022. The TIMR system worked as designed throughout the entire study; however, because of unexpected wind turbine operational challenges in 2021, there was not sufficient sample size to evaluate the treatment differences. In 2022, there were significant differences in fatality levels between treatment types and normal operating turbines. Curtailment at 5.0 m/s reduced fatalities by 30.8% compared to normal operations, and TIMR decreased fatalities by 48.6% compared to normal operations. Two different methods were used to evaluate the differences in energy loss for each treatment. The TIMR system resulted in 1.3% to 1.6 % annual energy loss in 2021 and 1.0% to 1.2 % in 2022. The Curtailment at 5.0 m/s resulted in 0.6% to 0.8 % annual energy loss in 2021 and 0.5% to 0.6 % in 2022. The project achieved all the stated objectives and demonstrated that TIMR is an effective technology that balances bat fatality reduction with energy generation. The results will support the deployment of TIMR and other acoustic sensor-based technologies. The research provides valuable insights into the impact of different treatments on fatality rates and energy outputs, contributing to the ongoing efforts to mitigate the environmental impact of wind energy.

17 WIND ENERGY↗

Abstract for CRADA between NETL and Westinghouse Electric Company

The National Energy Technology Laboratory (NETL) and Westinghouse will collaborate in testing a new NETL invention known as the single-crystal optical fiber Raman Distributed Temperature Sensor (DTS). Westinghouse will use the NETL Raman DTS to test performance of their new e-Vinci heat-pipe reactor systems.

47 OTHER INSTRUMENTATION↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Quench Propagation On Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, localized losses of superconductivity, known as quenches, pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered onto a printed circuit board (PCB) with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits, but resulted in local burnout. In the second test, a heater-induced quench at 300 A propagated bidirectionally with velocities ranging from 164–226 mm/s. These results provide critical parameters for improving REBCO quench detection and protection system design while accounting for REBCO’s limited bendability.

Ju, Han [Northern Illinois U.]↗

Quench Propagation on Rare-Earth Barium Copper Oxide (REBCO) Tape

Rare-earth barium copper oxide (REBCO) high-temperature superconductors can carry high currents with zero electrical resistance, enabling applications in high-field magnets, energy systems, and fusion devices. However, the localized losses of superconductivity called a quench pose a severe risk due to REBCO’s mechanical brittleness and slow quench propagation, hence complicating early detection. This work investigates quench propagation and thermal response through controlled experiments. A segmented REBCO tape soldered on a PCB with multiple voltage taps and temperature sensors was submerged in liquid nitrogen at 77 K. In the first test, current ramping produced a quench near 360 A, consistent with theoretical current limits but resulted in a local burn. In the second test, a heater-induced quench at 300 A propagated bidirectionally with measured velocities ranging from 164–226 mm/s. These measurements provide critical parameters for improving REBCO quench detection and protection system design with accounts for REBCO's limited bendability.

Ju, Han [NIU, DeKalb]↗

Total Energy CMR Production

The following outlines the optimized pulsed laser deposition (PLD) procedure used to prepare Nd{sub 0.67}Sr{sub 0.33}MnO{sub 3} (NSMO) temperature sensors at Towson University (Prof. Rajeswari Kolagani) for the LCLS XTOD Total Energy Monitor. The samples have a sharp metal/insulator transition at T {approx} 200 K and are optimized for operation at T {approx} 180 K, where their sensitivity is the highest. These samples are epitaxial multilayer structures of Si/YSZ/CeO/NSMO, where these abbreviations are defined in table 1. In this heterostructure, YSZ serves as a buffer layer to prevent deleterious chemical reactions, and also serves to de-oxygenate the amorphous SiO{sub 2} surface layer to generate a crystalline template for epitaxy. CeO and BTO serve as template layers to minimize the effects of thermal and lattice mismatch strains, respectively. More details on the buffer and template layer scheme are included in the attached manuscript accepted for publication in Sensor Letters (G. Yong et al., 2008).

36 MATERIALS SCIENCE↗