At least 811 records · Page 45

Modeling CO 2 flow in support of a shallow subsurface controlled leakage field test

Here, controlled release of carbon dioxide (CO 2 ) into the soil and atmosphere is performed to test detection and monitoring tools, for which several field laboratories were established by a number of institutions worldwide. Numerical simulations of CO 2 behavior in the shallow subsurface region are other forms of validation and verification of the leakage pathways and destinations. These reports aim to improve monitoring and verification of CO 2 in case of unexpected leakages for public assurance. In this work, we introduce the results of a numerical modeling study conducted to simulate the injection of CO 2 as carried out during a field test in Viamão, southern Brazil, where 20 kg day –1 of CO 2 was pumped for 30 days through a vertical well 3 m below ground in an altered granitic soil. Multiphase flow simulations were performed with the TOUGH2/EOS7CA software for unsaturated porous media, using field data and injection parameters, including sensitivity tests to permeability direction, diffusivity, and boundary conditions. Results with increased horizontal permeabilities are in better agreement with the field observations. In this condition, mass balance calculations indicate approximately 90% of injected CO2 (20 kg day –1 during 30 days) remains in the soil after 180 days from injection start, consistent with the measured flow through the soil–atmosphere interface.

03 NATURAL GAS↗

Testing of the ITER Central Solenoid Modules

The ITER Central Solenoid is under fabrication by the U.S. ITER organization and its subcontractors. U.S. ITER will supply seven modules to ITER IO, six of which will be assembled in a stack that forms the ITER Central Solenoid. The first modules that were built by GA at their facility, went into high voltage testing, including Paschen testing in the vacuum, and then they were tested at 4.5 K and up to 40 kA to demonstrate compliance of the coil with the ITER requirements. In this article, we present the Test Plan and results of the central solenoid (CS) module’s performance, especially at the full current. We measured critical temperatures in several pancakes, we measured ac losses, joint resistance, and hydraulic characteristics of the coils. We also measured displacements of the coil height and hoop strain of the CS module (CSM) to verify the structural mechanical characteristics of the coil along with the cooldown shrinkage of the coil. We studied the performance of the cowound quench detectors and confirmed their effectiveness in the suppression of inductive noise. This information is necessary for verification of the stack behavior of CS in ITER operation. The test results and preliminary analyses are presented, compared to expectations, and discussed.

Martovetsky, Nicolai↗

Experiment Automation with a Robot Arm using the Liquids Reflectometer Instrument at the Spallation Neutron Source

The Liquids Reflectometer instrument installed at the Spallation Neutron Source (SNS) enables observations of chemical kinetics, solid-state reactions and phase-transitions of thin film materials at both solid and liquid surfaces. Effective measurement of these behaviors requires each sample to be calibrated dynamically using the neutron beam and the data acquisition system in a feedback loop. Since the SNS is an intense neutron source, the time needed to perform the measurement can be the same as the alignment process, leading to a labor-intensive operation that is exhausting to users. An update to the instrument control system, completed in March 2013, implemented the key features of automated sample alignment and robot-driven sample management, allowing for unattended operation over extended periods, lasting as long as 20 hours. We present a case study of the effort, detailing the mechanical, electrical and software modifications that were made as well as the lessons learned during the integration, verification and testing process.

automated alignment↗

Surface harmonics method equations for solving the time-dependent neutron transport problems and their verification

Finite-difference time-dependent equations of Surface Harmonics method have been obtained for plane geometry. Verification of these equations has been carried out by calculations of tasks from 'Benchmark Problem Book ANL-7416'. The capacity and efficiency of the Surface Harmonics method have been demonstrated by solution of the time-dependent neutron transport equation in diffusion approximation. The results of studies showed that implementation of Surface Harmonics method for full-scale calculations will lead to a significant progress in the efficient solution of the time-dependent neutron transport problems in nuclear reactors. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Third-Party Supplier Risk Re-Classification Using Multi-Model Semantic Voting and External Web Augmentation

Risk decisions in many third-party risk management (TPRM) workflows rely on static inherent risk questionnaires (IRQ). These static forms provide a snapshot of the vendor from the business users’ perspective, as these requests are processed without cross-referencing for evidence. Consequently, responses can be misinformed or embellished with inaccuracies, thereby masking the vendor’s true risk to the enterprise. This paper presents a multi-stage verification framework to augment IRQs with web evidence and a deterministic ensemble of large language model assessors to reclassify risk. In a case study of 100 submissions previously misclassified as low risk, the proposed framework correctly identified 76% of the cases as high risk, while the existing workflow identified none. McNemar’s continuity corrected statistics of 74 were obtained with a two sided p-value of 2.65 × 10-23, indicating a significantly more effective workflow compared to the legacy model.

99 - GENERAL AND MISCELLANEOUS↗

Analysis of the VERA Core Physics Benchmark Problems using cosRMC Code

In reactor physics, two kinds of numerical methods are generally employed to solve the neutron transport equations, one of which is the deterministic method and the other one is the Monte Carlo method. Monte Carlo is widely used to provide reference solution because of its ability to deal with continuous energy cross sections and complex geometry. Just like any statistical process, the Monte Carlo method requires repetition to achieve a small relative uncertainty, and therefore may inevitably have larger simulation times than deterministic method. Fortunately, the great advancements of computer technology make it possible to apply Monte Carlo method in reactor core analysis. To promote nuclear power plant system design and simulation software self-reliance development, a Monte Carlo neutron/photon transport code cosRMC has been developed jointly by State Nuclear Power Software Development Center (SNPSDC) and Tsinghua University. The cosRMC is aimed at achieving full core calculations and analysis with high fidelity and efficiency by means of advanced methodologies and algorithms as well as high performance computing techniques. The cosRMC has many functions as criticality calculation, fixed-source calculation, burnup calculation, etc. In order to ensure its reliability, several types of verification and validation (V and V) work have been and are being carried out for cosRMC. The simulation results of cosRMC based on Problem 1 to 3 of VERA Core Physics Benchmark showed its good capability of 2D lattice and 3D assembly modeling. In this paper, some progressive verification results of multi-assembly and full core problems are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments

During radiotherapy treatments, quality assurance/control is essential, particularly dose delivery to patients. This study was designed to verify midline doses with diode in vivo dosimetry. Dosimetry was studied for 6-MV bilateral fields in head and neck cancer treatments and 10-MV bilateral and anteroposterior/posteroanterior (AP/PA) fields in pelvic cancer treatments. Calibrations with corrections of diodes were performed using plastic water phantoms; 190 and 100 portals were studied for head and neck and pelvis treatments, respectively. Calculations of midline doses were made using the midline transmission, arithmetic mean, and geometric mean algorithms. These midline doses were compared with the treatment planning system target doses for lateral or AP (PA) portals and paired opposed portals. For head and neck treatments, all 3 algorithms were satisfactory, although the geometric mean algorithm was less accurate and more uncertain. For pelvis treatments, the arithmetic mean algorithm seemed unacceptable, whereas the other algorithms were satisfactory. The random error was reduced by using averaged midline doses of paired opposed portals because the asymmetric effect was averaged out. Considering the simplicity of in vivo dosimetry, the arithmetic mean and geometric mean algorithm should be adopted for head/neck and pelvis treatments, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Verification of a Reduced-Order Extension Spring Model

Adopting reduced order models (ROMs) of springs lowers the computational cost of stronglink simulations. However, ROMs introduce currently unquantified error to such analyses. This study addresses that lack of data by comparing a hexahedral mesh to a commonly used ROM beam mesh. Two types of analyses were performed, a quasi-static displacement-controlled pull and a haversine shock, examining basic spring properties as well as dynamics and stress/strain data. Both tests showed good similarities between the hexahedral and beam meshes, especially when comparing reaction force and stress trends and maximums. Equivalent plastic strain results were not quite as favorable, indicating that the beam model may be less likely to correctly predict spring failure. Despite reducing computation times by over 48 hours in all shock cases, appropriate use of the ROM should carefully balance this advantage with its reduction in accuracy, especially when examining spring failure and outputting variables such as equivalent plastic strain.

42 ENGINEERING↗

High-Resolution Synthetic Solar Irradiance Sequence Generation: An LSTM-Based Generative Adversarial Network

The rapid growth of renewable energy resources penetration is bringing more challenges to power system planning and operation. Relevant renewable energy integration studies, such as the capability and dynamic performance of inverter-based resources' primary frequency response and fast frequency response, require high-resolution renewable generation output data that are representative of renewable energy resources. This paper focuses on creating synthetic but realistic solar irradiance data and proposes a long short-term memory-based generative adversarial network to generate high-resolution (second-level) solar irradiance sequences from low-resolution (minute-level) measurements. Combined with a classifier to recognize the solar irradiance patterns, the proposed model is trained using multi-loss functions to accurately capture the temporal correlations among both high-resolution and low-resolution sequences. Verification of the proposed approach is performed on the data set of the Oahu Solar Measurement Grid collected through the National Renewable Energy Laboratory. The results of the case studies demonstrate the proposed approach's capability to capture the statistical characteristics of different solar irradiance patterns and to generate high-quality synthetic solar irradiance sequences in high resolution.

dynamic scheduling↗

Development of a bayesian belief network model for the software reliability assessment of nuclear digital I and C safety systems - 206

Since the digital instrumentation and control systems are expected to play an important role for the safety systems in nuclear power plants (NPPs), the need has emerged to not only establish a basis for incorporating software behavior into digital I and C system reliability models, but also to quantify the failure probability of the software used in NPP digital protection systems. In this study, a Bayesian belief network (BBN) model is developed to quantitatively assess software reliability by estimating the number of faults in a software program considering its software development life cycle (SDLC). The model structure and parameters are established based on the information applicable to NPP safety-related systems and the evidence used to construct and quantify the BBN model was collected from three stages of expert elicitation. The software failure probability is estimated from the number of residual defects in a software program at the end of SDLC phase. As a case study, the BBN model was applied to quantify the software reliability of a typical digital protection software having the size of 50 function points and having the Medium development and validation and verification (V and V) qualities. The developed model can be applied to estimate the failure probability for both developing and deployed safety-related NPP software, and such results can be used to evaluate the quality of the digital I and C systems in addition to estimating potential reactor risk due to software failure. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MATCHED-INDEX-OF-REFRACTION FLOW FACILITY FOR FUNDAMENTAL AND APPLIED RESEARCH

Significant challenges face reactor designers with regard to thermal hydraulic design and associated modeling for advanced reactor concepts. Computational thermal hydraulic codes solve only a piece of the core. There is a need for a whole core dynamics system code with local resolution to investigate and understand flow behavior with all the relevant physics and thermo-mechanics. The matched index of refraction (MIR) flow facility at Idaho National Laboratory (INL) has a unique capability to contribute to the development of validated computational fluid dynamics (CFD) codes through the use of state-of-the-art optical measurement techniques, such as Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV). PIV is a non-intrusive velocity measurement technique that tracks flow by imaging the movement of small tracer particles within a fluid. At the heart of a PIV calculation is the cross correlation algorithm, which is used to estimate the displacement of particles in some small part of the image over the time span between two images. Generally, the displacement is indicated by the location of the largest peak. To quantify these measurements accurately, sophisticated processing algorithms correlate the locations of particles within the image to estimate the velocity (Ref. 1). Prior to use with reactor deign, the CFD codes have to be experimentally validated, which requires rigorous experimental measurements to produce high quality, multi-dimensional flow field data with error quantification methodologies. Computational thermal hydraulic codes solve only a piece of the core. There is a need for a whole core dynamics system code with local resolution to investigate and understand flow behavior with all the relevant physics and thermo-mechanics. Computational techniques with supporting test data may be needed to address the heat transfer from the fuel to the coolant during the transition from turbulent to laminar flow, including the possibility of an early laminarization of the flow (Refs. 2 and 3) (laminarization is caused when the coolant velocity is theoretically in the turbulent regime, but the heat transfer properties are indicative of the coolant velocity being in the laminar regime). Such studies are complicated enough that computational fluid dynamics (CFD) models may not converge to the same conclusion. Thus, experimentally scaled thermal hydraulic data with uncertainties should be developed to support modeling and simulation for verification and validation activities. The fluid/solid index of refraction matching technique allows optical access in and around geometries that would otherwise be impossible while the large test section of the INL system provides better spatial and temporal resolution than comparable facilities. Benchmark data for assessing computational fluid dynamics can be acquired for external flows, internal flows, and coupled internal/external flows for better understanding of physical phenomena of interest. The core objective of this study is to describe MIR and its capabilities, and mention current development areas for uncertainty quantification, mainly the uncertainty surface method and cross-correlation method. Using these methods, it is anticipated to establish a suitable approach to quantify PIV uncertainty for experiments performed in the MIR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Type A Verification Report for the Brookhaven Graphite Research Reactor Engineered Cap, Brookhaven National Laboratory Upton, New York

The Oak Ridge Institute for Science and Education (ORISE) has reviewed the project documentation and data for the Brookhaven Graphite Research Reactor (BGRR) Engineered Cap at Brookhaven National Laboratory (BNL) in Upton, New York. The Brookhaven Science Associates (BSA) have completed removal of affected soils and performed as-left surveys by BSA associated with the BGRR Engineered Cap. Sample results have been submitted, as required, to demonstrate that remediation efforts comply with the cleanup goal of {approx}15 mrem/yr above background to a resident in 50 years (BNL 2011a).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cleareye In-Ground and In-Concrete DIV Inspections: FY11 Final Report

This report summarizes the results of a series of feasibility testing studies for in-ground and in-concrete imaging/detection technologies including radar imaging and acoustic time-of flight method. The objectives of this project are: (1) Design Information Verification (DIV) Tools for In-Concrete Inspections - To determine the feasibility of using holographic radar imaging (HRI), radar imaging, and acoustic time-of-flight (TOF) non-destructive evaluation technologies to detect, locate and identify pipes and voids embedded in standard-density and high-density concrete walls that typify those the IAEA will need to verify during field inspections; (2) DIV Tools for In-Ground Inspections - To determine the feasibility of using HRI and radar imaging non-destructive evaluation technologies to detect, locate, and identify objects buried at various depths made of various materials (metal, plastic, wood, and concrete) and representing geometries that typify those the IAEA will need to verify during field inspections; and (3) Based on the results of the studies, recommend the next steps needed to realize fieldable tools for in-concrete and in-ground inspections (including detection of deeply buried polyvinyl chloride [PVC] pipes) that employ the technologies shown to be feasible.

09 BIOMASS FUELS↗

SU-E-T-256: Development of a Monte Carlo-Based Dose-Calculation System in a Cloud Environment for IMRT and VMAT Dosimetric Verification

Purpose: Intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are techniques that are widely used for treating cancer due to better target coverage and critical structure sparing. The increasing complexity of IMRT and VMAT plans leads to decreases in dose calculation accuracy. Monte Carlo simulations are the most accurate method for the determination of dose distributions in patients. However, the simulation settings for modeling an accurate treatment head are very complex and time consuming. The purpose of this work is to report our implementation of a simple Monte Carlo simulation system in a cloud-computing environment for dosimetric verification of IMRT and VMAT plans. Methods: Monte Carlo simulations of a Varian Clinac linear accelerator were performed using the BEAMnrc code, and dose distributions were calculated using the DOSXYZnrc code. Input files for the simulations were automatically generated from DICOM RT files by the developed web application. We therefore must only upload the DICOM RT files through the web interface, and the simulations are run in the cloud. The calculated dose distributions were exported to RT Dose files that can be downloaded through the web interface. The accuracy of the calculated dose distribution was verified by dose measurements. Results: IMRT and VMAT simulations were performed and good agreement results were observed for measured and MC dose comparison. Gamma analysis with a 3% dose and 3 mm DTA criteria shows a mean gamma index value of 95% for the studied cases. Conclusion: A Monte Carlo-based dose calculation system has been successfully implemented in a cloud environment. The developed system can be used for independent dose verification of IMRT and VMAT plans in routine clinical practice. The system will also be helpful for improving accuracy in beam modeling and dose calculation in treatment planning systems. This work was supported by JSPS KAKENHI Grant Number 25861057.

60 APPLIED LIFE SCIENCES↗

Midfidelity model verification for a point-absorbing wave energy converter with linear power take-off

In the preliminary design stage of a wave energy converter (WEC), researchers need fast and reliable simulation tools. High-fidelity numerical models are usually employed to study the wave-structure interaction, but the computational cost is demanding. As an alternative, midfidelity models can provide simulations in the order of real time. In this study, we operate Uppsala University’s WEC in a relatively mild sea state and model it using WEC-Sim. The model is verified based on OpenFOAM simulations. To analyze the ability of the midfidelity model to capture WEC dynamics, we investigate the system separately with 1, 2, and 3 degrees of freedom. We examine the contribution of viscous phenomena, and study both linear and weakly nonlinear solutions provided by WEC-Sim. Our results indicate that the viscous effects can be neglected in heave and surge motion, but not for pitch. We also find that the weakly nonlinear WEC-Sim solution successfully agrees with the computational fluid dynamics, whereas the linear solution could suggest misleading results.

16 TIDAL AND WAVE POWER↗

Exotic fermions in Kadyshevsky’s theory and the possibility to detect them

As it is known, the principal research interest of V.G. Kadyshevsky was the development of a geometric approach to quantum field theory with a constraint imposed on the mass spectrum of elementary particles. Non-Hermitian operators arising in this case seemed to be a major obstacle to the development of a consistent theory. These issues have been resolved recently, and the introduction of the pseudo-Hermitian algebraic approach to the construction of quantum theory was a major advance in this physical research. The central point of such theories is the construction of PT -symmetric non-Hermitian Hamiltonians with real eigenvalues. It is important to note that both purely theoretical and experimental studies (e.g., in non-Hermitian optics) are found among the many published papers on this subject. Therefore, we believe that the development of pseudo-Hermitian relativistic quantum theory with a maximal mass may provide favorable opportunities to discuss the possible experimental verification of theoretical results obtained in this field. Kadyshevsky himself regarded the hypothesis of existence of new particles, which he called exotic fermions, as an important prediction of his theory. The possibility of discovery of exotic neutrinos in precision experiments on the determination of the neutrino mass is discussed in the present study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

OECD/NEA expert group on uncertainty analysis for criticality safety assessment: Results of benchmark on sensitivity calculation (phase III)

The sensitivities of the k{sub eff} eigenvalue to neutron cross sections have become commonly used in similarity studies and as part of the validation algorithm for criticality safety assessments. To test calculations of the sensitivity coefficients, a benchmark study (Phase III) has been established by the OECD-NEA/WPNCS/EG UACSA (Expert Group on Uncertainty Analysis for Criticality Safety Assessment). This paper presents some sensitivity results generated by the benchmark participants using various computational tools based upon different computational methods: SCALE/TSUNAMI-3D and -1D, MONK, APOLLO2-MORET 5, DRAGON-SUSD3D and MMKKENO. The study demonstrates the performance of the tools. It also illustrates how model simplifications impact the sensitivity results and demonstrates the importance of 'implicit' (self-shielding) sensitivities. This work has been a useful step towards verification of the existing and developed sensitivity analysis methods. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-C-BRD-07: Three-Dimensional Dose Reconstruction in the Presence of Inhomogeneities Using Fast EPID-Based Back-Projection Method

Purpose: Three-dimensional dose verification can detect errors introduced by the treatment planning system (TPS) or differences between planned and delivered dose distribution during the treatment. The aim of the study is to extend a previous in-house developed three-dimensional dose reconstructed model in homogeneous phantom to situtions in which tissue inhomogeneities are present. Methods: The method was based on the portal grey images from an electronic portal imaging device (EPID) and the relationship between beamlets and grey-scoring voxels at the position of the EPID. The relationship was expressed in the form of grey response matrix that was quantified using thickness-dependence scatter kernels determined by series of experiments. From the portal grey-value distribution information measured by the EPID the two-dimensional incident fluence distribution was reconstructed based on the grey response matrix using a fast iterative algorithm. The accuracy of this approach was verified using a four-field intensity-modulated radiotherapy (IMRT) plan for the treatment of lung cancer in anthopomorphic phantom. Each field had between twenty and twenty-eight segments and was evaluated by comparing the reconstructed dose distribution with the measured dose. Results: The gamma-evaluation method was used with various evaluation criteria of dose difference and distance-to-agreement: 3%/3mm and 2%/2 mm. The dose comparison for all irradiated fields showed a pass rate of 100% with the criterion of 3%/3mm, and a pass rate of higher than 92% with the criterion of 2%/2mm. Conclusion: Our experimental results demonstrate that our method is capable of accurately reconstructing three-dimensional dose distribution in the presence of inhomogeneities. Using the method, the combined planning and treatment delivery process is verified, offing an easy-to-use tool for the verification of complex treatments.

60 APPLIED LIFE SCIENCES↗