Search NASA⌕ Search

SEARCH · Search NASA

Results for “angle diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Dynamics of High Molecular Weight Cylindrical and Lamellar Block Copolymers with X‐ray Photon Correlation Spectroscopy

Here, the structure and dynamics of polystyrene (PS)-b-poly(ethylene oxide) block copolymers (BCPs) are studied. The BCPs exhibit microphase-separated cylindrical and lamellar morphologies. Structural dynamics are measured with X-ray photon correlation spectroscopy in the small-angle regime. Morphologies and domain sizes are evaluated using small-angle X-ray scattering (SAXS), scanning electron microscopy, and atomic force microscopy. Different solvent processing conditions are investigated. Grain sizes evaluated using SAXS are found to depend on processing only for the rubbery majority BCP. The structural relaxation times are examined as a function of PS volume fraction, temperature, morphology, and structural sizes. Well above the glass transition temperature (T g ) of PS, all samples exhibit stretched autocorrelation decays and diffusive dynamics. Near T g of PS, the dynamics of all samples are anomalous with compressed autocorrelation decays and hyperdiffusive dynamics. This transition occurs at 153 °C or 1.13 T g of PS. In the diffusive regime (at high temperature), structural relaxation times are dependent on the processing method. Near PS T g (at low temperature), structural relaxation times scale with the PS volume fraction. Structural relaxation times do not correlate with grain size, indicating that the out-of-equilibrium state of PS dominates the structural dynamics of these strongly phase-segregated BCPs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crowded electrolytes containing redoxmers in different states of charge: Solution structure, properties, and fundamental limits on energy density

Nonaqueous redox flow batteries use liquid electrolytes containing redox-active organic molecules (redoxmers) as their energy storage medium. To maximize energy density, the redoxmer concentration needs to be maximized while maintaining low viscosity and high ionic conductivity. During charge, a redoxmer molecule pairs with an ion in the electrolyte while another ion migrates across the membrane to maintain electric neutrality. In a crowded electrolyte, this reconstitution changes physical and chemical properties of the solution. To explore these behaviors, a phenothiazine redoxmer fully miscible with acetonitrile was used, and electrochemical charge was mimicked by chemical oxidation. The solutions were examined using small-angle X-ray scattering, nuclear magnetic resonance, and conductometry and modeled using classical molecular dynamics. Overall, our study indicates that physical and structural properties of redoxmer solutions in both states of charge make it exceedingly difficult to increase the redoxmer concentrations over 2 M at any temperature without compromising dynamic properties of such solutions. The cause for this limitation is proximity to a gel-like regime in which fluidity, diffusivity, and ionic conductivity exponentially decrease with increasing concentration. This tendency is compounded by non-Arrhenius behavior of the electrolyte: a small increase in the concentration outruns gains in fluidity and conductivity at a higher temperature. Thus the properties of crowded electrolytes generally make it impossible to operate when gel-like behavior sets in. Pushing the redoxmer concentration to 2.5-3 M might be possible for small redoxmer molecules, but it would require the use of ionic liquid electrolytes at 340-360 K. (C) 2021 Elsevier B.V. All rights reserved.

25 ENERGY STORAGE↗

Nano-sized precipitate stability and its controlling factors in a NiAl-strengthened ferritic alloy

Coherent B2-ordered NiAl-type precipitates have been used to reinforce solid-solution bodycentered- cubic iron for high-temperature application in fossil-energy power plants. In this study, the stability of nano-sized precipitates in a NiAl-strengthened ferritic alloy was investigated at 700 - 950°C using ultra-small angle X-ray scattering and electron microscopies. Here we show that the coarsening kinetics of NiAl-type precipitates is in excellent agreement with the ripening model in multicomponent alloys. We further demonstrate that the interfacial energy between the matrix and NiAl-type precipitates is strongly dependent to differences in the matrix/precipitate compositions. The results profile the ripening process in multicomponent alloys by illustrating controlling factors (i.e., interfacial energy, diffusivities, and element partitioning). As a result, the study provides guidelines to design and develop high-temperature alloys with stable microstructures for long-term service.

36 MATERIALS SCIENCE↗

Analysis of toroidal phasing of resonant magnetic perturbation effects on edge transport in the DIII-D tokamak

Resonant Magnetic Perturbation (RMP) fields produced by external control coils are considered a viable option for the suppression of Edge Localized Modes in present and future tokamaks. In DIII-D, the RMPs are generated by six pairs of I-coils, each spanning 60° in toroidal angle, with the currents flowing in opposite directions in adjacent pairs of I-coils. Reversal of the currents in all I-coils, which produces a 60° toroidal shift in the RMP field configuration, generates uniquely different edge pedestal profiles of the density, temperature, and rotation velocities, implying different effects on the related edge transport phenomena caused by the difference in toroidal phase of the I-coil currents. The diffusive and non-diffusive transport effects of this RMP toroidal phase reversal are analyzed by comparing the ion and electron heat diffusivities, angular momentum transport frequencies, ion diffusion coefficients, and the particle pinch velocities interpreted from the measured profiles for the two phases of the I-coil currents.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quasi-one-dimensional Ising-like antiferromagnetism in the rare-earth perovskite oxide TbScO 3

The rare-earth perovskite TbScO 3 has been widely used as a substrate for the growth of epitaxial ferroelectric and multiferroic thin films, while its detailed low-temperature magnetic properties were rarely reported. In this paper, we performed detailed magnetization, specific heat, and single crystal neutron scattering measurements, along with the crystalline electric field calculations to study the low-temperature magnetic properties of TbScO 3. All our results suggest the magnetic Tb 3+ has an Ising-like pseudo-doublet ground state at low temperatures. Due to the constrain of local point symmetry, these Tb 3+ Ising moments are confined in the ab plane with a tilt angle of φ=±48° to the a axis. In zero field, the system undergoes an antiferromagnetic phase transition at T N =2.53 K, and forms a G x A y noncollinear magnetic structure below T N . Here, we find the dipole-dipole interactions play an important role to determine the magnetic ground state, which are also responsible for the quasi-one-dimensional magnetism in TbScO 3 . The significant anisotropic diffuse scatterings further confirm the quasi-one-dimensional magnetism along the c axis. The magnetic phase diagram with the field along the easy b axis is well established. In addition to the G x A y antiferromagnetic state, there is an exotic field-induced phase emerged near the critical field B c ≃0.7 T, where three-dimensional magnetic order is suppressed but strong one-dimensional correlations may still exist.

36 MATERIALS SCIENCE↗

The Luminosity Reduction with Hourglass Effect and Crossing Angle in an e-p Collider

This paper derived the luminosity reduction caused by crossing angle and hourglass effect in an asymmetric collision. Here, we gave the general expressions of the geometrical reduction factor of luminosity for the asymmetric case caused by crossing angle and hourglass effect,for tri-Gaussian bunches colliding. We also gave it simple expression in some special cases to recover the earlier results, such as the formulas for only hour-glass effect exist and only crossing angle exist. The expressions used in e-p collider are also analysed in detail.

Zhang, Yuhong↗

sashevis (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashemfr (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenir (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirlowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevislowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevishisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirhisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

Anisotropy in thermal conductivity of graphite flakes–SiC{sub p}/matrix composites: Implications in heat sinking design for thermal management applications

Within the frame of heat dissipation for electronics, a very interesting family of anisotropic composite materials, fabricated by liquid infiltration of a matrix into preforms of oriented graphite flakes and SiC particles, has been recently proposed. Aiming to investigate the implications of the inherent anisotropy of these composites on their thermal conductivity, and hence on their potential applications, materials with matrices of Al–12 wt.% Si alloy and epoxy polymer have been fabricated. Samples have been cut at a variable angle with respect to the flakes plane and thermal conductivity has been measured by means of two standard techniques, namely, steady state technique and laser flash method. Experimental results are presented and discussed in terms of current models, from which important technological implications for heat sinking design can be derived. - Highlights: • Anisotropy in thermal conductivity of graphite flakes-based composites is evaluated. • Samples are cut in a direction forming a variable angle with the oriented flakes. • For angles 0° and 90°, thermal conductivity does not depend on sample geometry. • For intermediate angles, thermal conductivity strongly depends on sample geometry. • “Thin” samples must be thicker than 600 μm, “thick” samples must be encapsulated.

36 MATERIALS SCIENCE↗

Laponite-Incorporated UiO-66-NH2-Polyethylene Oxide Composite Membranes for Protection against Chemical Warfare Agent Simulants

A strategy is developed to enhance the barrier protection of polyethylene oxide (PEO)-metal–organic framework (MOF) composite films against chemical warfare agent simulants. To achieve enhanced protection, an impermeable high-aspect-ratio filler in the form of Laponite RD (LRD) clay platelets was incorporated into a composite PEO film containing MOF UiO-66-NH 2 . The inclusion of the platelets aids in mitigating permeation of inert hydrocarbons (octane) and toxic chemicals (2-chloroethyl ethyl sulfide, 2-CEES) of dimensions/chemistry similar to prominent vesicant threats while still maintaining high water vapor transport rates (WVTR). By utilizing small-angle neutron scattering, small-angle X-ray scattering, and wide-angle X-ray scattering, the LRD platelet alignment of the films was determined, and the structure of the films was correlated with performance as a barrier material. Performance of the membranes against toxic chemical threats was assessed using permeation testing of octane and 2-CEES, a common simulant for the vesicant mustard gas, and breathability of the membranes was assessed using WVTR measurements. To assess their robustness, chemical exposure (in situ diffuse reflectance infrared Fourier transform spectroscopy) and mechanical (tensile strength) measurements were also performed. It was demonstrated that the barrier performance of the film upon inclusion of the LRD platelets exceeds that of other MOF-polymer composites found in the literature and that this approach establishes a new path for improving permselective materials for chemical protection applications.

36 MATERIALS SCIENCE↗

Resonant Interactions Between Protons and Oblique Alfven/Ion-Cyclotron Waves

Resonant interactions between ions and Alfven/ion-cyclotron (A/IC) waves may play an important role in the heating and acceleration of the fast solar wind. Although such interactions have been studied extensively for 'parallel' waves, whose wave vectors k are aligned with the background magnetic field B{sub 0}, much less is known about interactions between ions and oblique A/IC waves, for which the angle theta between k and B{sub 0} is nonzero. In this paper, we present new numerical results on resonant cyclotron interactions between protons and oblique A/IC waves in collisionless low-beta plasmas such as the solar corona. We find that if some mechanism generates oblique high-frequency A/IC waves, then these waves initially modify the proton distribution function in such a way that it becomes unstable to parallel waves. Parallel waves are then amplified to the point that they dominate the wave energy at the large parallel wave numbers at which the waves resonate with the particles. Pitch-angle scattering by these waves then causes the plasma to evolve towards a state in which the proton distribution is constant along a particular set of nested 'scattering surfaces' in velocity space, whose shapes have been calculated previously. As the distribution function approaches this state, the imaginary part of the frequency of parallel A/IC waves drops continuously towards zero, but oblique waves continue to undergo cyclotron damping while simultaneously causing protons to diffuse across these kinetic shells to higher energies. We conclude that oblique A/IC waves can be more effective at heating protons than parallel A/IC waves, because for oblique waves the plasma does not relax towards a state in which proton damping of oblique A/IC waves ceases.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for photons above 10 19 eV with the surface detector of the Pierre Auger Observatory

We use the surface detector of the Pierre Auger Observatory to search for air showers initiated by photons with an energy above 10 19 eV. Photons in the zenith angle range from 30° to 60° can be identified in the overwhelming background of showers initiated by charged cosmic rays through the broader time structure of the signals induced in the water-Cherenkov detectors of the array and the steeper lateral distribution of shower particles reaching ground. Applying the search method to data collected between January 2004 and June 2020, upper limits at 95% CL are set to an E -2 diffuse flux of ultra-high energy photons above 10 19 eV, 2 × 10 19 eV and 4 × 10 19 eV amounting to 2.11 × 10 -3 , 3.12 × 10 -4 and 1.72 × 10 -4 km -2 sr -1 yr -1 , respectively. While the sensitivity of the present search around 2 × 10 19 eV approaches expectations of cosmogenic photon fluxes in the case of a pure-proton composition, it is one order of magnitude above those from more realistic mixed-composition models. The inferred limits have also implications for the search of super-heavy dark matter that are discussed and illustrated.

ultra high energy photons and neutrinos↗