Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Potential absence of observed π2 linear-chain structures in 14O via 10C(α,α) resonances scattering

Background: The preference for light nuclear systems to coagulate into -particle clusters has been well-studied. The possibility of a linear chain configuration of -particles would allow for a new way to study this phenomenon. Purpose: A rotational band of states in C has been claimed showing a linear chain structure. The mirror system, O, has been studied here to examine how this linear chain structure is affected by replacing the valence neutrons with protons. Method: A beam of C was incident into a chamber filled with He:CO gas with the tracks recorded inside the TexAT Time Projection Chamber and the recoil -particles detected by a silicon detector array to measure the cross section. Results: The experimental cross section was compared with previous studies and fit using R-Matrix theory with the previously-observed O states being transformed to the C using mirror symmetry. The measured cross section does not replicate the claimed states, with the predicted cross section exceeding that observed at several energies and angles. Conclusion: A series of possibilities are highlighted with the most likely being that the originally-seen C states did not constitute a rotational band with a potentially incorrect spin assignment due to the limitations of the angular correlation method with non-zero spin particles. The work highlights the difficulties in measuring broad resonances corresponding to a linear chain state in a high level density.

Bishop, J.↗

pars2 (b1)

A laser disdrometer (LDIS) measures the drop size spectra and fall velocity of hydrometeors during precipitation events. The passage of hydrometeors through a horizontal area positioned between an eye-safe laser and an array detector results in blockage of the laser beam in proportion to the size of the drop or particle. In addition to drop/particle size and fall speed, precipitation type is classified. ARM also deploys video disdrometers (VDIS).

54 ENVIRONMENTAL SCIENCES↗

ld (b1)

A laser disdrometer (LDIS) measures the drop size spectra and fall velocity of hydrometeors during precipitation events. The passage of hydrometeors through a horizontal area positioned between an eye-safe laser and an array detector results in blockage of the laser beam in proportion to the size of the drop or particle. In addition to drop/particle size and fall speed, precipitation type is classified. ARM also deploys video disdrometers (VDIS).

54 ENVIRONMENTAL SCIENCES↗

Structure of ²⁰⁷Pb populated in ²⁰⁸Pb + ²⁰⁸Pb deep-inelastic collisions*

The yrast structure of 207 Pb above the 13/2 + isomeric state has been investigated in deep-inelastic collisions of 208 Pb and 208 Pb at ATLAS, Argonne National Laboratory. New and previously observed transitions were measured using the Gammasphere detector array. The level scheme of 207 Pb is presented up to ~ 6 MeV, built using coincidence and γ-ray intensity analyses. In addition, the spin and parity assignments of states were made, based on angular distributions and comparisons to shell model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of $\gamma $-decaying Isomers in the $^{100}$Sn Region Revisited

The study of nuclei in the region around the N = Z doubly-magic nucleus 100Sn has been of long standing interest for the nuclear structure and nuclear astrophysics. Recently, Park et al. have reported on properties of γ-decaying isomers and isomeric ratios in the vicinity of 100Sn. That experiment was performed at the Radioactive Ion Beam Factory (RIBF) of the RIKEN Nishina Center in Japan as a part of the EURICA campaign. Neutron-deficient nuclei were produced in a fragmentation reaction of a 124 Xe primary beam on a 9 Be target at an energy of 345 MeV/A. Secondary ions were separated and identified in the BigRIPS fragment separator and implanted in the silicon detector array WAS3ABi. The data presented here were obtained in another experiment performed at the RIBF using the same reaction but slightly different separator settings. New results of ratios of isomeric population and half-lives of γ-decaying isomers populated in the experiment are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of apparent ion temperature using the magnetic recoil spectrometer at the OMEGA laser facility

The Magnetic Recoil neutron Spectrometer (MRS) at the OMEGA laser facility has been routinely used to measure deuterium-tritium (DT) yield and areal density in cryogenically layered implosions since 2008. Recently, operation of the OMEGA MRS in higher-resolution mode with a new smaller, thinner (4 cm[sup]2, 57-um thick) CD2 conversion foil has also enabled inference of the apparent DT ion temperature (Tion) from MRS data. MRS-inferred Tion compares well with T[sub]ion as measured using neutron time-of-flight spectrometers, which is important as it demonstrates good understanding of the very different systematics associated with the two independent measurements. The MRS resolution in this configuration, deltaEMRS=0.91 MeV FWHM, is still higher than required for a high-precision Tion measurement. We show how fielding a smaller foil closer to target chamber center and redesigning the MRS detector array could bring the resolution to deltaEMRS=0.45 MeV, reducing the systematic Tion uncertainty by more than a factor of 4.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method and apparatus for two-dimensional spectroscopy

Preferred embodiments of the invention provide for methods and systems of 2D spectroscopy using ultrafast, first light and second light beams and a CCD array detector. A cylindrically-focused second light beam interrogates a target that is optically interactive with a frequency-dispersed excitation (first light) pulse, whereupon the second light beam is frequency-dispersed at right angle orientation to its line of focus, so that the horizontal dimension encodes the spatial location of the second light pulse and the first light frequency, while the vertical dimension encodes the second light frequency. Differential spectra of the first and second light pulses result in a 2D frequency-frequency surface equivalent to double-resonance spectroscopy. Because the first light frequency is spatially encoded in the sample, an entire surface can be acquired in a single interaction of the first and second light pulses.

DeCamp, Matthew F↗

Phenotypic Expression in Wheat Revealed Using FT-IR Microspectroscopy

Wheat selected for cultivation through the centuries has a glume that is 'soft' instead of 'tough' as naturally occurring. In production, this is desirable because it enables mechanical threshing with efficient separation of kernel from the head of each stalk without damaging the kernel. FT-IR microspectroscopy provides chemically based, objective assessment of genetic expression by measuring the extent of genetic expression. In the Microbeam Molecular Spectroscopy Laboratory, Manhattan, KS, an imaging FT-IR microspectrometer with a detector array focused on the image plane was used to obtain spectral data from dissected glume specimens of nine tough and eleven soft wheat cultivars in a rectangular mapping pattern. With cellulose as the substrate, the extent of lignification is measurable from the ratio of the lignin (1508 cm{sup -1}) baseline adjusted band area to the representative cellulosic (1370 cm{sup -1}) band area. A distinction between soft and tough glumes is obtained in numerical terms. Using a band ratio minimizes variation due to thickness differences. While analyzing mapped sections of glume, care is taken to avoid tabulation of spectral data from vascular bundles. Inclusion of these data would to avoid tabulation of spectral data from vascular bundles. Inclusion of these data would bias the analysis toward the composition of highly lignified vascular bundles. Spatially resolved focal plane array FT-IR microspectroscopy reveals the extent of glume lignification that is coincident with the toughness trait. This enables breeders to rank the degree of lignin expression and discriminate between soft and tough breeding results.

09 BIOMASS FUELS↗

IDENTIFICATION OF HIGH-SPIN STATES IN NEUTRON-RICH 88,90,92Kr AND 86Se

Level schemes of even-even neutron-rich {sup 88-92}Kr and {sup 86}Se have been investigated by measuring triple-{gamma} coincidence data from the spontaneous fission of {sup 252}Cf with the Gammasphere detector array. The level scheme of {sup 88}Kr has been extended up to 7169 keV state. Several new excited states with new transitions have been identified in {sup 90,92}Kr and {sup 86}Se. Spins and parities have been assigned to levels in these nuclei by following regional systematics and angular correlation measurements. The level structures of the N = 52, 54, Se, Kr, and Sr isotones are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new technique for measuring astrophysically important (alpha,p) reactions

Studying ({alpha},p) reactions of astrophysical interest with radioactive beams presents serious challenges because of the difficult nature of the target. We have developed a new approach for the measurement of ({alpha},p) reactions using heavy ion beams in inverse kinematics and have measured the {sup 4}He({sup 19}F,{sup 1}H){sup 22}Ne reaction as a demonstration. {sup 19}F beams were used at the Holifield Radioactive Ion Beam Facility (HRIBF) tandem accelerator in Oak Ridge National Laboratory (ORNL) to bombard a large scattering chamber filled with {sup 4}He gas. Recoiling protons from the reactions were detected by the large area annular silicon strip detector array (SIDAR). The {sup 19}F({alpha},p) and {sup 19}F({alpha},p') excitation functions were measured over the energy range of E{sub c.m.} {approx} 1-2.1 MeV, demonstrating the viability of the technique

43 PARTICLE ACCELERATORS↗

Application of Spatially Resolved High Resolution Crystal Spectrometry to ICF Plasmas

High resolution (λ/Δ λ ~ 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-μm 55 Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10-8 -10-6 times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Majorana Demonstrator

A brief review of the history and neutrino physics of double beta decay is given. A description of the MAJORANA DEMONSTRATOR research and development program, including background reduction techniques, is presented in some detail. The application of point contact (PC) detectors to the experiment is discussed, including the effectiveness of pulse shape analysis. The predicted sensitivity of a PC detector array enriched to 86% to 76Ge is given.

Aguayo, Estanislao↗

The Majorana Demonstrator search for neutrinoless double beta decay

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched 88% in 76Ge) to search for neutrinoless double beta decay in 76Ge. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.

Cuesta, C.↗

Fuel cell

A fuel cell comprising a membrane electrode assembly, and an IR transmissive window for thermographic analysis of a surface of the membrane electrode assembly is described. The test fuel cell provides a method of monitoring a fuel cell, and capturing a thermographic profile of said fuel cell with an IR detector array, while simultaneously measuring the electrochemical output of the cell, including current, voltages and half cell potentials.

30 DIRECT ENERGY CONVERSION↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Modular low cost trackerless spectral sensor

A photodiode sensor device and systems. The photodiode sensor device includes a housing portion. The housing portion includes a cylindrical enclosure. A window is disposed at a first end of the housing portion. A filter wheel is within the housing portion. A motor positioned within the housing is adjacent the filter wheel opposite the window. The motor is attached to the filter wheel. A photodiode sensor within the housing portion intermediate the first photodiode sensor and the window. The first photodiode sensor receives filtered light incident on the window and transmit a signal associated with sensed parameters of the filtered light. Also, a hemispherical dome for diffusing the light to a collimating lens has a grating, a focusing lens, and a linear detector array. An exit port transmits light to the collimating lens. The sensor array is opposite the grating for sensing the diffused light.

14 SOLAR ENERGY↗

Method and apparatus for evaluating superconducting tunnel junction detector noise versus bias voltage

A technique for characterizing the noise behavior of a superconducting tunnel junction (STJ) detector as a function of its applied bias voltage Vb by stepping the STJ's bias voltage across a predetermined range and, at each applied bias, making multiple measurements of the detector's current, calculating their mean and their standard deviation from their mean, and using this standard deviation as a measure of the STJ detector's noise at that applied bias. Because the method is readily executed under computer control, it is particularly useful when large numbers of STJ detectors require biasing, as in STJ detector arrays In a preferred implementation, the STJ is measured under computer control by attaching it to a digital spectrometer comprising a digital x-ray processor (DXP) coupled to a preamplifier that can set the STJ's bias voltage Vb using a digital-to-analog converter (DAC) controlled by the DXP.

Warburton, William K.↗