Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

SELKIE Spectral Extraction Results

This document describes results from the WAMOR Chesapeake Bay collection in October 2024, a data collection from the Arkeus HSOR hyperspectral sensor. The calibration array was staged at USCG Station Little Creek, Virginia. With the provided HSOR imagery and data, our analysis does not show a capability to effectively detect materials of interest from non-materials of interest as well as differentiate materials of interest from each other, the materials of interest being polypropylene, polyester, and cotton. The fundamental reasons are (1) the spectral bands of HSOR do not reside in specific wavelength locations to allow for material identification and (2) the provided imagery appears to not have consistent band-to-band relationships indicative of a lack of calibration (gain/offsets) or some other calibration issues. With regard to analyzing a subset of the delivered HSOR, HSOR can make general statements about materials not being water and have the capability to make color assessments.

36 MATERIALS SCIENCE↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high.

Freeman, A.↗

Calibration Results for J-ERS-1 SAR Data Produced by the Alaska SAR Facility

The Alaska SAR Facility has been receiving and processing SAR data from the J-ERS-1 satellite since Spring 1992. Corner reflectors have been set up for J-ERS-1 SAR calibration at a site near Delta Junction, in central Alaska. Image quality and calibration analysis results from the Delta Junction site and others will be presented in this paper. The impact of the 3-bit Analog-to-Digital Converter and the automatic stepping of the gain as a function of range in the J-ERS-1 radar receiver on calibration performance has been assessed. Preliminary observations on J-ERS-1 SAR data are that the average Signal-to-Noise ratio is generally fairly low, in the range 5-6 dB. Azimuth ambiguity levels are higher than preflight analysis indicated. Over land, the dynamic range in the backscatter at L-band for approximately 36 degree incidence angle is often fairly high...

Freeman, A.↗

The Flight Optimization System Weights Estimation Method

FLOPS has been the primary aircraft synthesis software used by the Aeronautics Systems Analysis Branch at NASA Langley Research Center. It was created for rapid conceptual aircraft design and advanced technology impact assessments. FLOPS is a single computer program that includes weights estimation, aerodynamics estimation, engine cycle analysis, propulsion data scaling and interpolation, detailed mission performance analysis, takeoff and landing performance analysis, noise footprint estimation, and cost analysis. It is well known as a baseline and common denominator for aircraft design studies. FLOPS is capable of calibrating a model to known aircraft data, making it useful for new aircraft and modifications to existing aircraft. The weight estimation method in FLOPS is known to be of high fidelity for conventional tube with wing aircraft and a substantial amount of effort went into its development. This report serves as a comprehensive documentation of the FLOPS weight estimation method. The development process is presented with the weight estimation process.

Wells, Douglas P.↗

Design and Characterization of a Sodium Iodide (NaI) Array for Coincidence Measurements

An array of sodium iodide detectors (NaI) was constructed to record time-correlated gamma ray measurements. The NaI Array consists of twelve 2×4×16-inch detectors. When the array is placed close to an inspected object, this arrangement provides high efficiency for gamma ray detection, particularly for high-energy gamma rays. Data are collected in time-tagged, list-mode format, which is suitable for the application of a variety of coincidence analysis methods. Automated energy calibration of each detector is accomplished by utilizing gamma radiation from thoriated welding rods that are embedded in the system. The energy resolution of spectra that are produced by the NaI array is 7.3% at 662 keV. The data are processed to sum gamma-ray energies for simultaneous detections in adjacent detectors, which are dominated by the escape of scattered photons from one detector and subsequent absorption in an adjacent detector. When data are processed in this way, the photopeak efficiency exceeds 20% over the range 400 keV to 10 MeV; the total efficiency, which includes the Compton continuum and single and double escape peaks, exceeds 70% over this energy range. Utilization of time correlations enables isolation of spectral features that are associated with the same decay cascade or fission event. Characterization of the response of the NaI Array to both gamma rays and neutrons with the Gamma Detector Response and Analysis Software (GADRAS) enables accurate computation for virtually any radiation sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MultiPEM Toolbox: User Manual [Rev. 2]

This document explains use of the Multi-Phenomenology Explosion Monitoring (Multi PEM) Toolbox, a collection of R scripts for estimating the unknown device parameters of a new event with uncertainty quantification. The methodology and application used for illustration in this user manual are fully documented in a Los Alamos National Laboratory technical report hereafter designated “WPA” for reference. Additional details on the application are found in a recent journal article. Two assessment types are available: rapid and complete. Rapid assessments are conducted in two stages, as described in Section 2. In the first stage, calibration data are used to estimate forward and error model parameters (WPA, §5.1) and (if relevant) errors-in-variables yield values for calibration sources (WPA, §3, Equation (3)). In the second stage, new event data are used to estimate the unknown new event device parameters (WPA, §5.2) with uncertainty quantification. Two options for treating the inferred first stage parameters in second stage Bayesian analysis are available: fixing them at their maximum likelihood estimate (default), or multiple imputation. Multiple imputation involves utilizing several posterior samples (imputations) of the first stage parameters as fixed values in the second stage posterior sampling of the new event device parameters. Second stage sampling is conducted across imputations in parallel to improve computational efficiency. This method produces improved uncertainty quantification of the new event device parameters compared with the default treatment of the first stage parameters, at the expense of additional computation. Complete assessments are conducted in a single stage, as described in Section 3. Calibration and (if relevant) new event data are used simultaneously to estimate all forward model, error model, and (if relevant) new event device parameters with uncertainty quantification on the latter. As the name suggests, rapid assessments generally run substantially faster than complete assessments (even with multiple imputation), because the results of first stage analysis can be stored and incorporated into estimating a relatively low-dimensional space of new event device parameters whenever relevant new event data becomes available. On the other hand, complete assessments must be run on the full set of model and device parameters with calibration and new event data every time the latter becomes available.

97 MATHEMATICS AND COMPUTING↗

Intrusive analysis for NEK5000: development of intrusive uncertainty quantification for high-dimensional, high-fidelity codes.

We study the use of lower-fidelity training data for uncertainty quantification of complex simulation models. In our approach, computationally expensive full-model outputs are approximated applying proper orthogonal-decomposition-based dimensionality reduction to the full model. A Gaussian-processes-based machine learning approach is then used to model the difference (or, rather, the correspondence) between the higher-fidelity and the lower-fidelity data. This stochastic model can be constructed by using few additional full code evaluations; it is used to calibrate arbitrarily many lower-quality outputs in order to create additional training data for sampling-based analysis. In effect, an adequate approximation of the simulation model’s response to uncertainty can be constructed at a modest computational cost. In fact, we aim at the number of full-model evaluations comparable to that required for a linear approximation (as opposed to numbers traditionally associated with sampling in high-dimensional spaces). In this report, we explain the basic algorithm, suggest some performance tuning options, and give a first characterization for the class of simulation models of nuclear engineering for which the suggested report is effective.

Roderick, O.↗

TU-F-18A-03: Improving Tissue Segmentation for Monte Carlo Dose Calculation Using DECT Data

Purpose: To develop a new segmentation technique using dual energy CT (DECT) to overcome limitations related to segmentation from a standard Hounsfield unit (HU) to electron density (ED) calibration curve. Both methods are compared with a Monte Carlo analysis of dose distribution. Methods: DECT allows a direct calculation of both ED and effective atomic number (EAN) within a given voxel. The EAN is here defined as a function of the total electron cross-section of a medium. These values can be effectively acquired using a calibrated method from scans at two different energies. A prior stoichiometric calibration on a Gammex RMI phantom allows us to find the parameters to calculate EAN and ED within a voxel. Scans from a Siemens SOMATOM Definition Flash dual source system provided the data for our study. A Monte Carlo analysis compares dose distribution simulated by dosxyz-nrc, considering a head phantom defined by both segmentation techniques. Results: Results from depth dose and dose profile calculations show that materials with different atomic compositions but similar EAN present differences of less than 1%. Therefore, it is possible to define a short list of basis materials from which density can be adapted to imitate interaction behavior of any tissue. Comparison of the dose distributions on both segmentations shows a difference of 50% in dose in areas surrounding bone at low energy. Conclusion: The presented segmentation technique allows a more accurate medium definition in each voxel, especially in areas of tissue transition. Since the behavior of human tissues is highly sensitive at low energies, this reduces the errors on calculated dose distribution. This method could be further developed to optimize the tissue characterization based on anatomic site.

60 APPLIED LIFE SCIENCES↗

Strain Gage Loads Calibration Testing with Airbag Support for the Gulfstream III SubsoniC Research Aircraft Testbed (SCRAT)

This paper describes the design and conduct of the strain-gage load calibration ground test of the SubsoniC Research Aircraft Testbed, Gulfstream III aircraft, and the subsequent data analysis and results. The goal of this effort was to create and validate multi-gage load equations for shear force, bending moment, and torque for two wing measurement stations. For some of the testing the aircraft was supported by three airbags in order to isolate the wing structure from extraneous load inputs through the main landing gear. Thirty-two strain gage bridges were installed on the left wing. Hydraulic loads were applied to the wing lower surface through a total of 16 load zones. Some dead-weight load cases were applied to the upper wing surface using shot bags. Maximum applied loads reached 54,000 lb. Twenty-six load cases were applied with the aircraft resting on its landing gear, and 16 load cases were performed with the aircraft supported by the nose gear and three airbags around the center of gravity. Maximum wing tip deflection reached 17 inches. An assortment of 2, 3, 4, and 5 strain-gage load equations were derived and evaluated against independent check cases. The better load equations had root mean square errors less than 1 percent. Test techniques and lessons learned are discussed.

flight tests↗

Parametrizing the detector response with neural networks

In high energy physics, characterizing the response of a detector to radiation is one of the most important and fundamental experimental tasks. In many cases, this task is accomplished by parameterizing summary statistics of the full detector response probability density. The parameterized detector response can then be used for calibration as well as for directly improving physics analysis sensitivity. This paper reports on how to parameterize summary statistics of the detector response using neural networks. Specifically, neural networks are powerful tools for incorporating multidimensional data and the loss function used during training determines which summary statistic is learned. One common summary statistic that has not been combined with deep learning (as far as the authors are aware) is the mode. A neural network-based approach to mode learning is proposed and empirically demonstrated in the context of high energy jet calibrations. Altogether, the neural network-based toolkit for detector response parameterization can enhance the utility of data collected at high energy physics experiments and beyond.

47 OTHER INSTRUMENTATION↗

GRDC. A Collaborative Framework for Radiological Background and Contextual Data Analysis

The Radiation Mobile Analysis Platform (RadMAP) is unique in its capability to collect both high quality radiological data from both gamma-ray detectors and fast neutron detectors and a broad array of contextual data that includes positioning and stance data, high-resolution 3D radiological data from weather sensors, LiDAR, and visual and hyperspectral cameras. The datasets obtained from RadMAP are both voluminous and complex and require analyses from highly diverse communities within both the national laboratory and academic communities. Maintaining a high level of transparency will enable analysis products to further enrich the RadMAP dataset. It is in this spirit of open and collaborative data that the RadMAP team proposed to collect, calibrate, and make available online data from the RadMAP system. The Berkeley Data Cloud (BDC) is a cloud-based data management framework that enables web-based data browsing visualization, and connects curated datasets to custom workflows such that analysis products can be managed and disseminated while maintaining user access rights. BDC enables cloud-based analyses of large datasets in a manner that simulates real-time data collection, such that BDC can be used to test algorithm performance on real and source-injected datasets. Using the BDC framework, a subset of the RadMAP datasets have been disseminated via the Gamma Ray Data Cloud (GRDC) that is hosted through the National Energy Research Science Computing (NERSC) Center, enabling data access to over 40 users at 10 institutions.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Analysis of AIS radiometry at Mono Lake, California

Airborne imaging spectrometer (AIS) data were studied to establish absolute instrumental calibration and to provide atmospheric corrections. Good agreement is found between calculated and measured radiances for uniform surface targets (beaches), but simulations of atmospheric properties with LOWTRAN lead to unreasonably low values of atmospheric precipitable water. Absorptions from CO2 are not detected in the AIS data, but are strongly present in the LOWTRAN model. The apparent low contrast of all atmospheric absorption bands leads to a study of contamination from overlapping spectral orders in the AIS data. The suspected contamination is shown unambiguously to be present beyond 1500 nm. The magnitude remains uncertain. Spectral band filling at 1400 nm cannot be accounted for by order mixing because of the 800 nm blocking filter used. Rough corrections for short wavelength mode observations might be possible if an after-the-fact radiometric calibration of the instrument can be developed.

Conel, J. E.↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation

The document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. This document supersedes the earlier version (Mueller and Austin 1995) published as Volume 25 in the SeaWiFS Technical Report Series. This document marks a significant departure from, and improvement on, theformat and content of Mueller and Austin (1995). The authorship of the protocols has been greatly broadened to include experts specializing in some key areas. New chapters have been added to provide detailed and comprehensive protocols for stability monitoring of radiometers using portable sources, abovewater measurements of remote-sensing reflectance, spectral absorption measurements for discrete water samples, HPLC pigment analysis and fluorometric pigment analysis. Protocols were included in Mueller and Austin (1995) for each of these areas, but the new treatment makes significant advances in each topic area. There are also new chapters prescribing protocols for calibration of sun photometers and sky radiance sensors, sun photometer and sky radiance measurements and analysis, and data archival. These topic areas were barely mentioned in Mueller and Austin (1995).

Fargion, Giulietta S.↗

[Calibration, Analysis, and Interpretation of SERTS and EUNIS Observation]

We have made satisfactory and expected progress in the first year of this project. The spectrophotometric data for the S asteroids of interest have been reduced, and lightcurve effects accounted for. We have begun mixing models for spectra of 6 Hebe, and expect to have a publication late in 2004 or early in 2005 on that part of the project. Preliminary models suggest that Hebe requires hydrated minerals to explain its spectrum in the 3-pm region. We will also perform mixing models with additional data which has been recently obtained. We have been able to constrain thermal properties on near-Earth asteroids (NEAs) as a result of thermal modeling done as part of this project. This work provides a means of obtaining albedo data from common visible-near IR data. This portion of the project has been presented at the DPS meeting in Monterey, and is being presented in expanded form at the Yarkovsky workshop at Arecibo Observatory in February. A manuscript is in preparation. In the coming year we expect to finish the thermal corrections for the spectrophotometric data, and complete the mixing models. The results will be prepared for publication, and the data offered to the PDS. It will also be available on the SMASS website (smass.mit.edu), for which the PI is webmaster.

Source record↗

Meteorological analysis of MAPS first shuttle flight

The data from the MAPS radiometer launched on board the first shuttle flight was analyzed. The meteorological data relevant to the MAPS measurements was also analyzed so that the in situ calibration measurements and any anomalous features within the data set can be evaluated in the context of the atmospheric circulation during the period of observation. The three dimensioned isentropic analysis scheme was used as the main analytical tool. A graphical output of the N and delta channel signals, black body reference temperatures, reduced CO concentrations and ground tracks for orbits 15 and 16 were provided. The insentropic trajectory methods was emphasized because it is a basic requirement that the analysis be extended to incorporate daily data within the tropics.

Doherty, M.↗

Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

Carpenter, P.↗

Using the USCCS for sub microsecond spacecraft clock calibration

The Return Data Delay technique which requires knowledge of spacecraft range is commonly used for correlating a spacecraft clock against a ground time standard when millisecond accuracy is required. An analysis is presented that allows using the user spacecraft clock calibration system (USCCS) to correlate a spacecraft clock to better than one microsecond accuracy. The basic USCCS algorithm has been simplified and it is shown to result in about one microsecond accuracy without requiring orbital information. By considering the relative motion of the user satellite, the TDRS and the earth station about the center of the earth, a correction of almost two orders of magnitude can be made. Such accuracy is required for scientific investigations that require correlating coincident radiation or particle detection with a remote laboratory.

Sank, Victor J.↗

Evaluation of the Sensor Data Record from the Nadir Instruments of the Ozone Mapping Profiler Suite (OMPS)

This paper evaluates the first 15 months of the Ozone Mapping and Profiler Suite (OMPS) Sensor Data Record (SDR) acquired by the nadir sensors and processed by the National Oceanic and Atmospheric Administration Interface Data Processing Segment. The evaluation consists of an inter-comparison with a similar satellite instrument, an analysis using a radiative transfer model, and an assessment of product stability. This is in addition to the evaluation of sensor calibration and the Environment Data Record product that are also reported in this Special Issue. All these are parts of synergetic effort to provide comprehensive assessment at every level of the products to ensure its quality. It is found that the OMPS nadir SDR quality is satisfactory for the current Provisional maturity. Methods used in the evaluation are being further refined, developed, and expanded, in collaboration with international community through the Global Space-based Inter-Calibration System, to support the upcoming long-term monitoring.

validation↗