Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Analysis of CT Numbers and Relative Proton Stopping Powers for Real Tissue Samples

The accuracy of computer planning of clinical proton dose distribution is partly determined by the precision of the conversion of CT Hounsfield Units to relative proton stopping powers. The calibration curves from three different sources were compared. We have found about 5% differences between proton stopping power values in the range from -700 HU to 0 HU. Calibration data for several soft tissues and phantom materials were also experimentally measured. The data for the tissues are in a good agreement with the calibration curves however data for phantom materials have significant deviations.

07 ISOTOPE AND RADIATION SOURCES↗

The source-lens clustering effect in the context of lensing tomography and its self-calibration

Cosmic shear can only be measured where there are galaxies. This source-lens clustering (SLC) effect has two sources, intrinsic source clustering and cosmic magnification (magnification/size bias). Lensing tomography can suppress the former. However, this reduction is limited by the existence of photo-z error and nonzero redshift bin width. Furthermore, SLC induced by cosmic magnification cannot be reduced by lensing tomography. Through N-body simulations, we quantify the impact of SLC on the lensing power spectrum in the context of lensing tomography. We consider both the standard estimator and the pixel-based estimator. We find that none of them can satisfactorily handle both sources of SLC. (1) For the standard estimator, SLC induced by both sources can bias the lensing power spectrum by O(1)–O(10)%. Intrinsic source clustering also increases statistical uncertainties in the measured lensing power spectrum. However, the standard estimator suppresses intrinsic source clustering in the cross-spectrum. (2) In contrast, the pixel-based estimator suppresses SLC through cosmic magnification. However, it fails to suppress SLC through intrinsic source clustering and the measured lensing power spectrum can be biased low by O(1)–O(10)%. In short, for typical photo-z errors (σ{sub z}/(1+z)=0.05) and photo-z bin sizes (Δz{sup P}=0.2), SLC alters the lensing E-mode power spectrum by 1–10%, with ℓ∼10{sup 3} and z{sub s}∼1 being of particular interest to weak lensing cosmology. Therefore the SLC is a severe systematic for cosmology in Stage-IV lensing surveys. We present useful scaling relations to self-calibrate the SLC effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Overview of SIM wide angle astrometric system calibration strategies

This paper summarizes two very different strategies envisioned for calibrating the systematic field dependent biases present in the Space Interferometry Mission (SIM) instrument. The Internal Calibration strategy is based on pre-launch measurements combined with a set of on orbit measurements generated by a source internal to the instrument. The External Calibration strategy uses stars as an external source for generating the calibration function. Both approaches demand a significant amount of innovation given that SIM's calibration strategy requires a post-calibration error of 100picometers over a 15 degree field of regard while the uncalibrated instrument introduces 10's-100's of nanometers of error. The calibration strategies are discussed in the context of the Wide Angle Astrometric mode of the instrument, although variations on the Internal Calibration Strategy may be used for doing Narrow Angle Astrometry.

calibration SIM optical modeling↗

AWSD Reactive Burn Model for the HMX‐Based High Explosive LX‐04

An Arrhenius–Wescott–Stewart–Davis (AWSD) reactive burn model is applied to describe shock initiation and detonation properties of the HMX-based high explosive LX-04. The parameters in the model are calibrated to data from multiple sources. The thermodynamic equations of state used in the model are calibrated to a combination of thermochemical calculations for HMX and LX-04 as well as experimentally-measured cylinder expansion results for LX-04. The kinetic parameters are calibrated to velocity data from gas gun experiments performed using EDC-32—a high explosive with the same chemical composition as LX-04 but different structural properties, and scaled rate stick data for PBX 9012. The AWSD model is shown to accurately describe the shock initiation and propagation of LX-04. Very good agreement is observed between the available experimental data and the AWSD model output. The presented results constitute an accurate LX-04 reactive burn model for use in engineering-scale models and simulations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

2D Simulations of Diamagnetic Loop Calibrations

Diamagnetic loops can be used as a non-invasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. A comprehensive theory for interpreting data from a diamagnetic loop relates the rms beam radius to the excluded flux measured by the loop and the beam current. Thus, primary calibration of the loop must relate the loop signal directly to the exclude d flux. We have simulated these calibrations with a 2D field solver in order to identify possible sources of uncertainty in our calibration technique.

43 PARTICLE ACCELERATORS↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CALCULATION OF BURNABLE POISON CORRECTION FACTORS FOR PWR FRESH FUEL ACTIVE COLLAR MEASUREMENTS

Verification of commercial low enriched uranium light water reactor fuel takes place at the fuel fabrication facility as part of the overall international nuclear safeguards solution to the civilian use of nuclear technology. The fissile mass per unit length is determined nondestructively by active neutron coincidence counting using a neutron collar. A collar comprises four slabs of high density polyethylene that surround the assembly. Three of the slabs contain {sup 3}He filled proportional counters to detect time correlated fission neutrons induced by an AmLi source placed in the fourth slab. Historically, the response of a particular collar design to a particular fuel assembly type has been established by careful cross-calibration to experimental absolute calibrations. Traceability exists to sources and materials held at Los Alamos National Laboratory for over 35 years. This simple yet powerful approach has ensured consistency of application. Since the 1980's there has been a steady improvement in fuel performance. The trend has been to higher burn up. This requires the use of both higher initial enrichment and greater concentrations of burnable poisons. The original analytical relationships to correct for varying fuel composition are consequently being challenged because the experimental basis for them made use of fuels of lower enrichment and lower poison content than is in use today and is envisioned for use in the near term. Thus a reassessment of the correction factors is needed. Experimental reassessment is expensive and time consuming given the great variation between fuel assemblies in circulation. Fortunately current modeling methods enable relative response functions to be calculated with high accuracy. Hence modeling provides a more convenient and cost effective means to derive correction factors which are fit for purpose with confidence. In this work we use the Monte Carlo code MCNPX with neutron coincidence tallies to calculate the influence of Gd{sub 2}O{sub 3} burnable poison on the measurement of fresh pressurized water reactor fuel. To empirically determine the response function over the range of historical and future use we have considered enrichments up to 5 wt% {sup 235}U/{sup tot}U and Gd weight fractions of up to 10 % Gd/UO{sub 2}. Parameterized correction factors are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

SU-E-T-259: Development of a Primary Standard for LDR Brachytherapy

Purpose: The National Research Council initiated a program in 2012 to develop a primary standard to calibrate I-125 and Pd-103 sources used for LDR brachytherapy and disseminate this through calibration services to Canadian users. This will simplify procedures as Canadian cancer centres currently have to ship instruments to the US. Methods: The standard is based on a commercial version of the wide-angle free air chamber (WAFAC) pioneered by NIST. Significant enhancements were implemented to improve signal-to-noise and measurement reproducibility and eliminate electric field effects. Validation of this ionization chamber was then carried out in a low-energy X -ray beam (∼ 31 keV) where the dose rate had been previously established using the existing NRC primary standard free-air chamber. As a final component of this initial testing, measurements were made with a set of I-125 seeds (with air kerma strength traceable to NIST). Results: Excellent agreement of the two NRC free-air chambers was obtained within the combined standard uncertainty of 0.5 %. However, it was found that the WAFAC response is very sensitive to the beam geometry (distance from the source, diameter of the beam-defining aperture, etc) and Monte Carlo calculations, carried out to evaluate these geometry corrections, have confirmed the experimental results. The results for the seed measurements indicated a precision of better than 1 % is achievable for a reasonable acquisition time and the air kerma strength agreed with the manufacturer (NIST-traceable) value within 2 %. Conclusion: The prototype primary standard for LDR brachytherapy has met accuracy target of 3 % for the determination of air kerma strength. Work is ongoing to refine operation of the device and develop the calibration protocol for clinical users, with an anticipated launch of a calibration service in late 2015.

60 APPLIED LIFE SCIENCES↗

Solar radiation calibration facility.

A recently completed calibration facility for the NASA Mississippi Test Site is described. It combines the spectrum of water cooled long arc xenon radiation sources with the integration sphere concept covered by a special barium sulfate diffusely reflecting paint. The sphere is six feet in diameter and completely encompasses the four xenon sources (2.5 kW each) and the five pyranometers under calibration. The sources are contained within the base of the central pedestal and allow the radiation to be emitted into the lower hemisphere. Only through diffuse reflection and multiple scattering is the radiation finally incident upon the test zone, which is in the equatorial plane of the sphere on the top of the pedestal. The sphere is temperature controlled.

Hershey, T. L.↗

Utilizing Environmental Tracers to Reduce Groundwater Flow and Transport Model Parameter Uncertainties

Abstract Non‐uniqueness in groundwater model calibration is a primary source of uncertainty in groundwater flow and transport predictions. In this study, we investigate the ability of environmental tracer information to constrain groundwater model parameters. We utilize a pilot point calibration procedure conditioned to subsets of observed data including: liquid pressures, tritium ( 3 H), chlorofluorocarbon‐12 (CFC‐12), and sulfur hexafluoride (SF 6 ) concentrations; and groundwater apparent ages inferred from these environmental tracers, to quantify uncertainties in the heterogeneous permeability fields and infiltration rates of a steady‐state 2‐D synthetic aquifer and a transient 3‐D model of a field site located near Riverton, Wyoming (USA). To identify the relative data worth of each observation data type, the post‐calibration uncertainties of the optimal parameters for a given observation subset are compared to that from the full observation data set. Our results suggest that the calibration‐constrained permeability field uncertainties are largest when liquid pressures are used as the sole calibration data set. We find significant reduction in permeability uncertainty and increased predictive accuracy when the environmental tracer concentrations, rather than apparent groundwater ages, are used as calibration targets in the synthetic model. Calibration of the Riverton field site model using environmental tracer concentrations directly produces infiltration rate estimates with the lowest uncertainties, however; permeability field uncertainties remain similar between the environmental tracer concentration and apparent groundwater age calibration scenarios. This work provides insight on the data worth of environmental tracer information to calibrate groundwater models and highlights potential benefits of directly assimilating environmental tracer concentrations into model parameter estimation procedures.

54 ENVIRONMENTAL SCIENCES↗

MST radar data management

One atmospheric variable which can be deduced from stratosphere-troposphere (ST) radar data other than wind speed and direction is C sub n sup 2, related to the eddy dissipation rate. The computation of C sub n sup 2 makes use of the transmitted power (average, or peak plus duty cycle), the range of the echoes, and the returned power. The returned power can be calibrated only if a noise source of known strength is imposed; e.g., in the absence of absolute calibration, one can compare the diurnal noise signal with the galactic sky temperature. Thus to compute C sub n sup 2 one needs the transmitter power, the returned signal as a function of height, and the returned noise at an altitude so high that it is not contaminated by any signal. Now C sub n sup 2 relates with the amount of energy within the inertial subrange, and for many research studies it may be desirable to relate this with background flow as well as shears or irregularities on the size of the sample volume. The latter are quantified by the spectral width.

Nastrom, G. D.↗

Segmented Gamma Scanner for Small Containers of Uranium Processing Waste- 12295

The Segmented Gamma Scanner (SGS) is commonly utilized in the assay of 55-gallon drums containing radioactive waste. Successfully deployed calibration methods include measurement of vertical line source standards in representative matrices and mathematical efficiency calibrations. The SGS technique can also be utilized to assay smaller containers, such as those used for criticality safety in uranium processing facilities. For such an application, a Can SGS System is aptly suited for the identification and quantification of radionuclides present in fuel processing wastes. Additionally, since the significant presence of uranium lumping can confound even a simple 'pass/fail' measurement regimen, the high-resolution gamma spectroscopy allows for the use of lump-detection techniques. In this application a lump correction is not required, but the application of a differential peak approach is used to simply identify the presence of U-235 lumps. The Can SGS is similar to current drum SGSs, but differs in the methodology for vertical segmentation. In the current drum SGS, the drum is placed on a rotator at a fixed vertical position while the detector, collimator, and transmission source are moved vertically to effect vertical segmentation. For the Can SGS, segmentation is more efficiently done by raising and lowering the rotator platform upon which the small container is positioned. This also reduces the complexity of the system mechanism. The application of the Can SGS introduces new challenges to traditional calibration and verification approaches. In this paper, we revisit SGS calibration methodology in the context of smaller waste containers, and as applied to fuel processing wastes. Specifically, we discuss solutions to the challenges introduced by requiring source standards to fit within the confines of the small containers and the unavailability of high-enriched uranium source standards. We also discuss the implementation of a previously used technique for identifying the presence of uranium lumping. The SGS technique is a well-accepted NDA technique applicable to containers of almost any size. It assumes a homogenous matrix and activity distribution throughout the entire container; an assumption that is at odds with the detection of lumps within the assay item typical of uranium-processing waste. This fact, in addition to the difficultly in constructing small reference standards of uranium-bearing materials, required the methodology used for performing an efficiency curve calibration to be altered. The solution discussed in this paper is demonstrated to provide good results for both the segment activity and full container activity when measuring heterogeneous source distributions. The application of this approach will need to be based on process knowledge of the assay items, as biases can be introduced if used with homogenous, or nearly homogenous, activity distributions. The bias will need to be quantified for each combination of container geometry and SGS scanning settings. One recommended approach for using the heterogeneous calibration discussed here is to assay each item using a homogenous calibration initially. Review of the segment activities compared to the full container activity will signal the presence of a non-uniform activity distribution as the segment activity will be grossly disproportionate to the full container activity. Upon seeing this result, the assay should either be reanalyzed or repeated using the heterogeneous calibration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Forward Global Photometric Calibration of the Dark Energy Survey

Many scientific goals for the Dark Energy Survey (DES) require the calibration of optical/NIR broadband b = grizY photometry that is stable in time and uniform over the celestial sky to one percent or better. It is also necessary to limit to similar accuracy systematic uncertainty in the calibrated broadband magnitudes due to uncertainty in the spectrum of the source. Here we present a "Forward Global Calibration Method (FGCM)" for photometric calibration of the DES, and we present results of its application to the first three years of the survey (Y3A1). The FGCM combines data taken with auxiliary instrumentation at the observatory with data from the broadband survey imaging itself and models of the instrument and atmosphere to estimate the spatial and time dependences of the passbands of individual DES survey exposures. "Standard" passbands that are typical of the passbands encountered during the survey are chosen. The passband of any individual observation is combined with an estimate of the source spectral shape to yield a magnitude in the standard system. This "chromatic correction" to the standard system is necessary to achieve subpercent calibrations and in particular, to resolve ambiguity between the broadband brightness of a source and the shape of its SED. The FGCM achieves a reproducible and stable photometric calibration of standard magnitudes of stellar sources over the multiyear Y3A1 data sample with residual random calibration errors of per exposure. The accuracy of the calibration is uniform across the DES footprint to within . The systematic uncertainties of magnitudes in the standard system due to the spectra of sources are less than for main-sequence stars with .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II: Nonlinear Model Calibration for Synchrotrons

This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was {approx} 1 x 10{sup -5} for 1024 turns (to calibrate the linear optics) and {approx} 1 x 10{sup -4} for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is {approx}0.1. Since the transverse damping time is {approx}20 msec, i.e., {approx}4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain {delta}{nu} {approx} 1 x 10{sup -5}. A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al since the 40s for that matter. Conclusion: what's elementary in the latter is considered 'advanced', if at all, in the former. It is little surprise then that published measurements typically contains neither error bars (for the random errors) nor estimates for the systematic in the former discipline. We have also showed how to estimate the state space by turn-by-turn data from two adjacent BPMs. And how to improve the resolution of the nonlinear resonance spectrum by Fourier analyzing the linear action variables instead of the betatron motion. In fact, the state estimator could be further improved by adding a Kalman filter. For transparency, we have also summarized on how these techniques provide a framework- and method for a TQM (Total Quality Management) approach for the main ring. Of course, to make the ($2.5M) turn-by-turn data acquisition system that is being implemented (for all the BPMs) useful, a means ({approx}10% contingency for the BPM system) to drive the beam is obviously required.

43 PARTICLE ACCELERATORS↗

A procedure for calculation of monitor units for passively scattered proton radiotherapy beams

The purpose of this study is to validate a monitor unit (MU) calculation procedure for passively scattered proton therapy beams. The output dose per MU (d/MU) of a therapeutic radiation beam is traditionally calibrated under specific reference conditions. These conditions include beam energy, field size, suitable depth in water or water equivalent phantom in a low dose gradient region with known relative depth dose, and source to point of calibration distance. Treatment field settings usually differ from these reference conditions leading to a different d/MU that needs to be determined for delivering the prescribed dose. For passively scattered proton beams, the proton specific parameters, which need to be defined, are related to the energy, lateral scatterers, range modulating wheel, spread out Bragg peak (SOBP) width, thickness of any range shifter, the depth dose value relative to the normalization point in the SOBP, and scatter both from the range compensator and inhomogeneity in the patient. Following the custom for photons or electrons, a set of proton dosimetry factors, representing the changes in the d/MU relative to a reference condition, can be defined as the relative output factor (ROF), SOBP factor (SOBPF), range shifter factor (RSF), SOBP off-center factor (SOBPOCF), off-center ratio (OCR), inverse square factor (ISF), field size factor (FSF), and compensator and patient scatter factor (CPSF). The ROF, SOBPF, and RSF are the major contributors to the d/MU and were measured using an ion chamber in water tank during the clinical commissioning of each beam to create a dosimetry beam data table to be used for calculating the monitor units. The following simple formula is found to provide an independent method to determine the d/MU at the point of interest (POI) in the patient, namely, (d/MU)=ROF{center_dot}SOBPF{center_dot}RSF{center_dot}SOBPOCF{center_dot}OCR{center_dot}FSF{center_dot}ISF{center_dot}CPSF. The monitor units for delivering the intended dose (D) to the POI can be obtained from MU=D divide (d/MU). The accuracy and robustness of the above formula were validated by calculating the d/MU in water for many different combinations of beam parameters and comparing it with the corresponding measured d/MU by an ion chamber in a water or water/plastic phantom. This procedure has been in use for MU calculation for patient treatment fields at our facility since May 2006. The differences in the calculated and measured values of the d/MU for 623 distinct fields used for patient treatment during the period of May 2006 to February 2007 are within 2% for 99% of these fields. The authors conclude that an intuitive formula similar to the one used for monitor unit calculation of therapeutic photon beams can be used to compute the monitor units of passively scattered proton therapy beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

A CATALOG OF NEAR-IR SOURCES FOUND TO BE UNRESOLVED WITH MILLIARCSECOND RESOLUTION

Calibration is one of the long-standing problems in optical interferometric measurements, particularly with long baselines which demand stars with angular sizes on the milliarcsecond scale and no detectable companions. While systems of calibrators have been generally established for the near-infrared in the bright source regime (K {approx}< 3 mag), modern large interferometers are sensitive to significantly fainter magnitudes. We aim to provide a list of sources found to be unresolved from direct observations with high angular resolution and dynamic range, which can be used to choose interferometric calibrators. To this purpose, we have used a large number of lunar occultations recorded with the ISAAC instrument at the Very Large Telescope to select sources found to be unresolved and without close companions. An algorithm has been used to determine the limiting angular resolution achieved for each source, taking into account a noise model built from occulted and unocculted portions of the light curves. We have obtained upper limits on the angular sizes of 556 sources, with magnitudes ranging from K{sub s} Almost-Equal-To 4 to 10, with a median of 7.2 mag. The upper limits on possible undetected companions (within Almost-Equal-To 0.''5) range from K{sub s} Almost-Equal-To 8 to 13, with a median of 11.5 mag. One-third of the sources have angular sizes {<=}1 mas, and two-thirds have sizes {<=}2 mas. This list of unresolved sources matches well the capabilities of current large interferometric facilities. We also provide available cross-identifications, magnitudes, spectral types, and other auxiliary information. A fraction of the sources are found to be potentially variable. The list covers parts of the Galactic Bulge and in particular the vicinity of the Galactic Center, where extinction is very significant and traditional lists of calibrators are often insufficient.

79 ASTRONOMY AND ASTROPHYSICS↗