Search NASA⌕ Search

SEARCH · Search NASA

Results for “control systems control system analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Robustness Analysis and Optimally Robust Control Design via Sum-of-Squares

A control analysis and design framework is proposed for systems subject to parametric uncertainty. The underlying strategies are based on sum-of-squares (SOS) polynomial analysis and nonlinear optimization to design an optimally robust controller. The approach determines a maximum uncertainty range for which the closed-loop system satisfies a set of stability and performance requirements. These requirements, de ned as inequality constraints on several metrics, are restricted to polynomial functions of the uncertainty. To quantify robustness, SOS analysis is used to prove that the closed-loop system complies with the requirements for a given uncertainty range. The maximum uncertainty range, calculated by assessing a sequence of increasingly larger ranges, serves as a robustness metric for the closed-loop system. To optimize the control design, nonlinear optimization is used to enlarge the maximum uncertainty range by tuning the controller gains. Hence, the resulting controller is optimally robust to parametric uncertainty. This approach balances the robustness margins corresponding to each requirement in order to maximize the aggregate system robustness. The proposed framework is applied to a simple linear short-period aircraft model with uncertain aerodynamic coefficients.

Dorobantu, Andrei↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 2 continues the presentation of IOA worksheets.

Prust, Chet D.↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 3

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 3 continues the presentation of IOA worksheets.

Prust, Chet D.↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 4

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. Volume 4 continues the presentation of IOA worksheets and contains the potential critical items list.

Prust, Chet D.↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

The High Performance Computing Initiative

The paper discusses NASA High Performance Computing Initiative (HPCI), an essential component of the Federal High Performance Computing Program. The HPCI program is designed to provide a thousandfold increase in computing performance, and apply the technologies to NASA 'Grand Challenges'. The Grand Challenges chosen include integrated multidisciplinary simulations and design optimizations of aerospace vehicles throughout the mission profiles; the multidisciplinary modeling and data analysis of the earth and space science physical phenomena; and the spaceborne control of automated systems, handling, and analysis of sensor data and real-time response to sensor stimuli.

Holcomb, Lee B.↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical Modeling and Thermal Analysis Toolbox (EMTAT) User’s Guide

A simulation toolbox has been developed to model the electrical portions of Electrified Aircraft Propulsion (EAP) systems, including self-heating of electrical systems. Dynamic models of EAP systems often include turbomachinery, an electrical power system, and a thermal management system. These portions of the propulsion system can operate on timescales covering six orders of magnitude, which poses a challenging modeling task. Assumptions and approximations are made in an effort to capture the dynamics relevant to engine, electrical system, and thermal system interactions, while still allowing for fast simulations. These assumptions and approximations enable the electrical component models to run at the time scale of the turbomachinery, neglecting the very high frequency electrical dynamics, while demonstrating representative behavior of the end-to-end system. Thus the models execute in an acceptable time frame for what would otherwise be an extremely stiff simulation. The resulting simulations of EAP systems are appropriate for system-level control design and analysis. The objective of this User's Guide is to present an overview of the usage of the Electrical Modeling and Thermal Analysis Toolbox (EMTAT). It will describe some of the approximations made to accommodate rapid execution, and some of the design tools that allow matching the model to component specifications. This paper will describe the basic usage of the software toolbox, and also provide an example of EAP system modeling using EMTAT.

Mark E. Bell↗

Kinetic isolation tether experiment

Progress was made on the analysis of tether damping and on experimentation of the control system on the laboratory simulator. The damping analysis considers the dynamics of a long tether connecting two spacecraft in Earth orbit, one of the spacecraft having dominant mass. In particular, it considers the material damping of the tether. The results show that, with properly chosen tether material and braiding structure, longitudinal vibration of the tethered system is well damped. A particularly effective method of implementing attitude control for tethered satellites is to use the tether tension force to generate control torques by moving the tether attach point relative to the satellite center of mass. A scaled, one dimensional laboratory simulation of the KITE mission was built and preliminary experiments of the proposed attitude control system were performed. The simulator was built to verify theoretical predictions of attitude controllability, and to investigate the technological requirements in order to implement this concept. A detailed description of the laboratory apparatus is provided, and in addition, the results of the preliminary experiments are presented and discussed.

Powell, J. David↗

Proceedings of the 2004 NASA/ONR Circulation Control Workshop, Part 2

This conference proceeding is comprised of papers that were presented at the NASA/ONR Circulation Control Workshop held 16-17 March 2004 at the Radisson-Hampton in Hampton, VA. Over two full days, 30 papers and 4 posters were presented with 110 scientists and engineers in attendance, representing 3 countries. As technological advances influence the efficiency and effectiveness of aerodynamic and hydrodynamic applications, designs, and operations, this workshop was intended to address the technologies, systems, challenges and successes specific to Coanda driven circulation control in aerodynamics and hydrodynamics. A major goal of this workshop was to determine the state-of-the-art in circulation control and to assess the future directions and applications for circulation control. The 2004 workshop addressed applications, experiments, computations, and theories related to circulation control, emphasizing fundamental physics, systems analysis, and applied research. The workshop consisted of single session oral presentations, posters, and written papers that are documented in this unclassified conference proceeding. The format of this written proceeding follows the agenda of the workshop. Each paper is followed with the presentation given at the workshop. the editors compiled brief summaries for each effort that is at the end of this proceeding. These summaries include the paper, oral presentation, and questions or comments that occurred during the workshop. The 2004 Circulation Control Workshop focused on applications including Naval vehicles (Surface and Underwater vehicles), Fixed Wing Aviation (general aviation, commercial, cargo, and business aircraft); V/STOL platforms (helicopters, military aircraft, tilt rotors); propulsion systems (propellers, jet engines, gas turbines), and ground vehicles (automotive, trucks, and other); wind turbines, and other nontraditional applications (e.g., vacuum cleaner, ceiling fan). As part of the CFD focus area of the 2004 CC Workshop, CFD practitioners were invited to compute a two-dimensional benchmark problem for which geometry, flow conditions, grids, and experimental data were available before the workshop. The purpose was to accumulate a database of simulations for a single problem using a range of CFD codes, turbulence models, and grid strategies so as to expand knowledge of model performance/requirements and guide simulation of practical CC configurations.

Jones, Gregory S.↗

A new approach to the design of time-varying control systems with application to the Space Shuttle Boost

A general approach to the analysis and design of closed-loop control for slowly time-varying linear systems is presented. The approach uses the method of generalized multiple scales in which slow and fast dynamics are systematically separated by employing different 'clocks' which measure time at varying rates. The clocks, which are necessarily nonlinear functions of time, are chosen in such a manner that the system dynamics are asymptotically invariant with respect to the new time scale. A transfer function relating the output to the input for general linear slowly time-varying systems is developed and represents the actual system under certain conditions. The clock function is shown to satisfy an algebraic characteristic equation and can be determined in terms of the coefficients. The approach can be viewed as an extension of time-invariant linear feedback control theory.

Ramanth, R. V.↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

A remotely controlled orbiting retriever

A preliminary design effort was recently carried out to investigate methods of removing a certain class of space objects from Shuttle type orbits. Specifically, expired satellites, upper stages, and other objects of potential danger to the Shuttle are the targets of the study. The Trash Remover and Satellite Hauler (TRASH-1) design effort was broken into several disciplines: mission analysis, systems engineering, dynamics and control, power, thermal, and propulsion. A basic requirements is that TRASH-1 go up in the Shuttle. It must be reusable and capable of disposing of more than one item per mission for cost effectiveness. These requirements imply TRASH-1 should use current technology, be modular in design, and be relatively maneuverable. In order to maximize utility, it should be able to both capture and deorbit objects. The design was a basic bus with attachable modules which can either capture or deorbit, depending on the module.

Kaplan, M. H.↗

Dual-Use Space Technology Transfer Conference and Exhibition

This is the second volume of papers presented at the Dual-Use Space Technology Transfer Conference and Exhibition held at the Johnson Space Center February 1-3, 1994. Possible technology transfers covered during the conference were in the areas of information access; innovative microwave and optical applications; materials and structures; marketing and barriers; intelligent systems; human factors and habitation; communications and data systems; business process and technology transfer; software engineering; biotechnology and advanced bioinstrumentation; communications signal processing and analysis; medical care; applications derived from control center data systems; human performance evaluation; technology transfer methods; mathematics, modeling, and simulation; propulsion; software analysis and decision tools; systems/processes in human support technology; networks, control centers, and distributed systems; power; rapid development; perception and vision technologies; integrated vehicle health management; automation technologies; advanced avionics; and robotics technologies.

Krishen, Kumar↗

DAO's Next Generation Physical-Space/Finite-Volume Data Assimilation System: Formulation and Initial Evaluation

The Physical-space/Finite-volume Data Assimilation System (fvDAS) is the next generation global atmospheric data assimilation system in development at the Data Assimilation Office at NASA's Goddard Space Flight Center. It is based on a new finite-volume general circulation model jointly developed by NASA and NCAR, and on the Physical-Space Statistical Analysis System (PSAS) developed at the DAO. In this talk we will describe the general system formulation, the adaptive quality control and general aspects of the error covariance modeling. The NASA-NCAR GCM is a completely new model which replaces the CEOs GCM used in the previous GEOS-1/2/3 Data Assimilation systems. A particular configuration of adaptive Statistical Quality Control and the Physical-space Statistical Analysis System (PSAS) are currently implemented in DAO's operational Data Assimilation System. However, the unique finite-volume formulation of the NASA-NCAR GCM, combined with the generality of the observation-space formulation of PSAS, provides for a very simple and accurate model-analysis interface. The system assimilates a variety of conventional and satellite observations. In particular, TOVS Level 1B radiances are assimilated using a 1-D variational scheme, both in clear sky and cloudy conditions. Computationally, the fvDAS runs approximately 10 times faster than the operational GEOS-Terra system. We will show that the next-generation fvDAS has much improved observation-minus-6hr forecast (O-F) statistics, as well as 5-day forecast skills. Top of the atmosphere radiation fields are in closer agreement with CERES measurements, with realistic precipitation and moisture fields. We will also show that the finite-volume formulation of the fvDAS produce assimilated fields which are more suitable for driving constituent transport models.

daSilva, A.↗

18-Degree-of-Freedom Controller Design for the ST7 Disturbance Reduction System

This paper presents the overall design and analysis process of the spacecraft controller being developed at NASA's Goddard Space Flight Center to close the loop between the GRS and the micro-newton colloidal thrusters. The essential dynamics of the ST7-DRS are captured in a simulation including eighteen rigid-body dynamic degrees of freedom: three translations and three rotations for the spacecraft and for each test mass. The ST7 DRS comprises three control systems: the attitude control system (ACS) to maintain a sun-pointing attitude; the drag free control (DFC) to center the spacecraft about the test masses; and the test mass suspension control. This paper summarizes the control design and analysis of the ST7-DRS 18-DOF model, and is an extension of previous analyses employing a 7-DOF planar model of ST-7.

Markley, F. L.↗