Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Patient-specific Dosimetric Benefits of Proton Therapy for Skull-base Tumors Using a Geometric Knowledge-based Method

Purpose: To predict the organ at risk (OAR) dose levels achievable with proton beam therapy (PBT), solely based on the geometric arrangement of the target volume in relation to the OARs. A comparison with an alternative therapy yields a prediction of the patient-specific benefits offered by PBT. This could enable physicians at hospitals without proton capabilities to make a better-informed referral decision or aid patient selection in model-based clinical trials. Methods and Materials: Skull-base tumors were chosen to test the method, owing to their geometric complexity and multitude of nearby OARs. By exploiting the correlations between the dose and distance-to-target in existing PBT plans, the models were independently trained for 6 types of OARs: brainstem, cochlea, optic chiasm, optic nerve, parotid gland, and spinal cord. Once trained, the models could estimate the feasible dose–volume histogram and generalized equivalent uniform dose (gEUD) for OAR structures of new patients. The models were trained using 20 patients and validated using an additional 21 patients. Validation was achieved by comparing the predicted gEUD to that of the actual PBT plan. Results: The predicted and planned gEUD were in good agreement. Considering all OARs, the prediction error was +1.4 ± 5.1 Gy (mean ± standard deviation), and Pearson's correlation coefficient was 93%. By comparing with an intensity modulated photon treatment plan, the model could classify whether an OAR structure would experience a gain, with a sensitivity of 93% (95% confidence interval: 87%-97%) and specificity of 63% (95% confidence interval: 38%-84%). Conclusions: We trained and validated models that could quickly and accurately predict the patient-specific benefits of PBT for skull-base tumors. Similar models could be developed for other tumor sites. Such models will be useful when an estimation of the feasible benefits of PBT is desired but the experience and/or resources required for treatment planning are unavailable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring drought-responsive crucial genes in Sorghum

Drought severely affects global food production. Sorghum is a typical drought-resistant model crop. Based on RNA-seq data for Sorghum with multiple time points and the gray correlation coefficient, this paper firstly selects candidate genes via mean variance test and constructs weighted gene differential co-expression networks (WGDCNs); then, based on guilt-by-rewiring principle, the WGDCNs and the hidden Markov random field model, drought-responsive crucial genes are identified for five developmental stages respectively. Enrichment and sequence alignment analysis reveal that the screened genes may play critical functional roles in drought responsiveness. A multilayer differential co-expression network for the screened genes reveals that Sorghum is very sensitive to pre-flowering drought. Furthermore, a crucial gene regulatory module is established, which regulates drought responsiveness via plant hormone signal transduction, MAPK cascades, and transcriptional regulations. The proposed method can well excavate crucial genes through RNA-seq data, which have implications in breeding of new varieties with improved drought tolerance.

60 APPLIED LIFE SCIENCES↗

Detection and attribution of long-term and fine-scale changes in spring phenology over urban areas: A case study in New York State

Spring phenology plays an essential role in climate change, terrestrial ecosystem, and public health. Field-based monitoring and understanding of changes in spring phenology for long periods and in large regions are challenging due to the limited in-site observations. Space-based remotely sensed observations offer great potentials for monitoring decadal spring phenology changes from regional to global scales. However, the coarse-scale remotely sensed observations are insufficient to capture fine-scale spring phenology dynamics, especially in urban areas, and this makes it challenging for understanding the combined effects of climate change and urbanization on spring phenology. We derived the start of phenology season (SOS) in New York State using 30 m Landsat observations from 1990 to 2015 to understand the impact of the environment and urbanization on SOS. The results show that SOS for different years reveals heterogeneous spatial distribution. Most regions of New York State have been experiencing significant spring phenology changes in form of earlier onset of vegetation greening, ranging from 0.2 to 0.6 day/year during 1990 to 2015, and this trend varies slightly with latitudes and urbanization levels. Further, spatial correlation analysis shows that the increase in temperature and urbanization could both promote the advancement of SOS. However, the effect of urbanization (partial correlation coefficient (R) ranges from −0.289 to −0.542) on SOS is greater than the effect of temperature (R ranges from 0.006 to −0.192). The study generates a high spatio-temporal resolution spring phenology dataset for ecological, environmental and public health studies, especially in urban areas, and reveals the importance of better accounting for the urbanization effects when quantifying the SOS dynamics in phenology models.

Landsat↗

Rapid Coal-Ash Characterization using Geophysical Methods & Machine Learning

Coal combustion products (CCP) are challenging to delineate in heterogeneous field settings. Conventional methods (test pits, coring, and laboratory analyses) are labor-intensive, slow, invasive, and provide sparse spatial coverage. This study evaluates whether rapid non-invasive geophysical screening methods—induced polarization (IP), magnetic susceptibility, and nuclear magnetic resonance (NMR) —combined with surface colorimetry (RGB_24), can discriminate CCP-soil mixtures and provide reliable estimates of CCP content. Laboratory measurements were collected on five CCP-soil mixtures (series) and modeled using (i) a linear baseline, (ii) a calibrated non-linear (power-mean) model, and (iii) a machine-learning (ML) Random Forest approach, with validation via leave-one-series-out and site-specific tests. Across the five series, individual signals—particularly IP and magnetic susceptibility—were strongly predictive of ash content but were consistently outperformed by combined models. The pooled calibrated non-linear and ML models captured the observed non-linearity and achieved high accuracy and precision, improving on linear fits. Colorimetry showed the weakest direct relationship with ash content for the tested samples but improved performance when included in multi-signal models. At pre-selected 3.5% decision threshold, calibrated and ML approaches yielded near-perfect classification (Matthews correlation coefficient ˜ 1), suggesting strong practical operability for field screening. Additionally, field-analog tests highlighted the role of endmembers—accuracy declined without access to end-member measurements but was largely recovered by collecting a minimal labeled pair for local recalibration. With end members, accuracy remained high. Globally trained models performed well on three operational unknowns; however, series-specific refits provided the most accurate predictions. Overall, these results highlight the potential of combining rapid geophysics and minimal local calibration for improved coal-ash delineation.

Peshtani, Klaudio↗

High-temperature deformation behavior of the extruded Ti-22Al-25Nb alloy fabricated by powder metallurgy

Highlights: • The high-temperature deformation behavior of the extruded Ti-22Al-25Nb alloy was analyzed. • A true strain-compensated Arrhenius-type constitutive model was established. • The processing maps of true strains 0.2, 0.4, and 0.6 were constructed to optimize the processing parameters. • Microstructural evolution and deformation mechanism in different conditions were explained. - Abstract: The hot-deformation behavior of the extruded Ti-22Al-25Nb alloy was investigated by compression testing in the 1213–1333 K temperature range, under a 0.001–1.0 s{sup −1} strain-rate range. The activation energy, Q, at a deformation strain of 0.3, was calculated to be 574.80 kJ mol{sup −1}. A strain-compensated Arrhenius-type constitutive model was established for this alloy, with an average absolute relative error (AARE) and correlation coefficient (R) of 7.64% and 0.994, respectively. Based on the dynamic materials model (DMM), processing maps were developed by combining the power dissipation and instability maps. An instability region was identified in the 1213–1278 K temperature range and 0.022–1.0 s{sup −1} strain-rate range. The microstructure of specimens deformed under different conditions were analyzed to characterize the corresponding deformation mechanisms. The main softening mechanisms in the stability regions were dynamic recrystallization (DRX) and dynamic globularization. The grain size of the specimen deformed at 1313 K/0.001 s{sup −1} was approximately 15.2 μm.

36 MATERIALS SCIENCE↗

Synthesis and characterization of Bi{sub 1.56}Sb{sub 1.48}Co{sub 0.96}O{sub 7} pyrochlore sun-light-responsive photocatalyst

Graphical abstract: Heterogeneous photo Fenton process with dye sensitized mechanism of RhB by Bi{sub 1.56}Sb{sub 1.48}Co{sub 0.96}O{sub 7} compound. - Highlights: • Bi{sub 1.56}Sb{sub 1.48}Co{sub 0.96}O{sub 7} (BSCO) catalyst was synthesized by improved solid state reaction method. • BSCO/H{sub 2}O{sub 2}/UVA and BSCO/H{sub 2}O{sub 2}/SL catalyst systems exhibit excellent photocatalytic activities for rhodamine B. • The photocatalytic degradation was preceded via heterogeneous photo Fenton mechanism process. • ·OH radicals are the main reactive species for the degradation of RhB. - Abstract: Novel nanostructure pyrochlore Bi{sub 1.56}Sb{sub 1.48}Co{sub 0.96}O{sub 7} was successfully synthesized via solid state reaction method in air. The as-synthesized photocatalyst was characterized by X-ray diffraction, Scanning electron microscopy and UV–vis diffuse reflectance spectroscopy techniques. The results showed that the BSCO was crystallized with the pyrochlore-type structure, cubic crystal system and space group Fd3m. The average particle size and band gap for BSCO were D = 76.29 nm and E{sub g} = 1.50 eV respectively. Under the optimum conditions for discoloration of the dye: initial concentration of 20 mg L{sup −1} RhB, pH 7, 25 °C, 0.5 mL H{sub 2}O{sub 2} and BSCO/dye mass ration of 1 g L{sup −1}, 97.77 and 90.16% of RhB were removed with BSCO/H{sub 2}O{sub 2} photocatalytic system within 60 min of irradiation time under UVA- and SL irradiations respectively. Pseudo-second-order kinetic model gave the best fit, with highest correlation coefficients (R{sup 2} ≥ 0.99). On the base of these results, the mechanism of the enhancement of the discoloration efficiency was discussed. .

36 MATERIALS SCIENCE↗

Deep-Learning-Derived Evaluation Metrics Enable Effective Benchmarking of Computational Tools for Phosphopeptide Identification

Tandem mass spectrometry (MS/MS)-based phosphoproteomics is a powerful technology for global phosphorylation analysis. However, applying four computational pipelines to a typical mass spectrometry (MS)-based phosphoproteomic dataset from a human cancer study, we observed a large discrepancy among the reported phosphopeptide identification and phosphosite localization results, underscoring a critical need for benchmarking. While efforts have been made to compare performance of computational pipelines using data from synthetic phosphopeptides, evaluations involving real application data have been largely limited to comparing the numbers of phosphopeptide identifications due to the lack of appropriate evaluation metrics. We investigated three deep learning-derived features as potential evaluation metrics: phosphosite probability, Delta RT and spectral similarity. Predicted phosphosite probability is computed by MusiteDeep, which provides high accuracy as previously reported; Delta RT is defined as the absolute retention time (RT) difference between RTs observed and predicted by AutoRT; and spectral similarity is defined as the Pearson’s correlation coefficient between spectra observed and predicted by pDeep2. Using a synthetic peptide dataset, we found that both Delta RT and spectral similarity provided excellent discrimination between correct and incorrect peptide-spectrum matches (PSMs) both when incorrect PSMs involved wrong peptide sequences and even when incorrect PSMs were caused by only incorrect phosphosite localization. Based on these results, we used all the three deep learning-derived features as evaluation metrics to compare different computational pipelines on diverse set of phosphoproteomic datasets and showed their utility in benchmarking performance of the pipelines. The benchmark metrics demonstrated in this study will enable users to select computational pipelines and parameters for routine analysis of phosphoproteomics data and will offer guidance for developers to improve computational methods.

59 BASIC BIOLOGICAL SCIENCES↗

Factors Affecting Prostate Volume Estimation in Computed Tomography Images

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Registration Surrogate and Patient Factors on the Interobserver Variability of Electronic Portal Image Guidance During Prostate Radiotherapy

Intraprostatic fiducial markers (IPM) and electronic portal imaging (EPI) are commonly used to identify and correct for prostate motion during radiotherapy. However, little data is available on the precision of this image-guidance technique. This study quantified impact of different registration surrogates and patient factors on the interobserver variability of manual EPI alignment during prostate radiotherapy. For 50 prostate radiotherapy patients previously implanted with 3 IPM, five observers manually aligned 150 pairs of orthogonal EPI to the reference digital reconstructed radiograph using Varian Vision EPI analysis software. Images were aligned using: Bony anatomy (BA), single mid-prostate IPM (SM); and 2 strategies using 3 IPM: center of mass (COM) and rotate and translate (R and T). Intraclass correlation coefficients (ICCs) were calculated to quantify interobserver variability. The absolute displacements measured using SM and R and T were compared with those using COM. The impact of patients' pelvic diameter and adjuvant hormone therapy on interobserver variability were also evaluated. Twelve thousand displacement values were collected for analysis. The maximum discrepancy between the 5 observers was >2 mm in 47% of measurements using BA, 5% using SM, 4% using R and T, and 3% using COM. Both of the 3 IPM alignment strategies demonstrated lower interobserver variability than the single IPM strategy (ICC 0.94-0.97 vs. 0.82-0.94). BA had the highest interobserver variability (ICC = 0.43-0.90). Pelvic diameter and hormone therapy had no discernible impact on interobserver variability. Compared with COM, the absolute displacements measured using the other IPM strategies were statistically different (p < 0.001), but 95% of the absolute magnitude of differences between the strategies were {<=}1 mm. The high reproducibility among the observers demonstrated the precision of prostate localization using multiple IPM and EPI, which was not influenced by the patient factors studied. Bony anatomy displayed the highest interobserver variability of the 4 alignment, likely because of the limited EPI field-of-view. Alignment using more than one IPM is recommended to minimize interobserver variability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preoperative treatment planning with intraoperative optimization can achieve consistent high-quality implants in prostate brachytherapy

Advances in brachytherapy treatment planning systems have allowed the opportunity for brachytherapy to be planned intraoperatively as well as preoperatively. The relative advantages and disadvantages of each approach have been the subject of extensive debate, and some contend that the intraoperative approach is vital to the delivery of optimal therapy. The purpose of this study was to determine whether high-quality permanent prostate implants can be achieved consistently using a preoperative planning approach that allows for, but does not necessitate, intraoperative optimization. To achieve this purpose, we reviewed the records of 100 men with intermediate-risk prostate cancer who had been prospectively treated with brachytherapy monotherapy between 2006 and 2009 at our institution. All patients were treated with iodine-125 stranded seeds; the planned target dose was 145 Gy. Only 8 patients required adjustments to the plan on the basis of intraoperative findings. Consistency and quality were assessed by calculating the correlation coefficient between the planned and implanted amounts of radioactivity and by examining the mean values of the dosimetric parameters obtained on preoperative and 30 days postoperative treatment planning. The amount of radioactivity implanted was essentially identical to that planned (mean planned radioactivity, 41.27 U vs. mean delivered radioactivity, 41.36 U; R{sup 2} = 0.99). The mean planned and day 30 prostate V100 values were 99.9% and 98.6%, respectively. The mean planned and day 30 prostate D90 values were 186.3 and 185.1 Gy, respectively. Consistent, high-quality prostate brachytherapy treatment plans can be achieved using a preoperative planning approach, mostly without the need for intraoperative optimization. Good quality assurance measures during simulation, treatment planning, implantation, and postimplant evaluation are paramount for achieving a high level of quality and consistency.

61 RADIATION PROTECTION AND DOSIMETRY↗

A quantitative assessment of volumetric and anatomic changes of the parotid gland during intensity-modulated radiotherapy for head and neck cancer using serial computed tomography

To evaluate the change in volume and movement of the parotid gland measured by serial contrast-enhanced computed tomography scans in patients with head and neck cancer treated with parotid-sparing intensity-modulated radiotherapy (IMRT). A prospective study was performed on 13 patients with head and neck cancer undergoing dose-painted IMRT to 69.96 Gy in 33 fractions. Serial computed tomography scans were performed at baseline, weeks 2, 4, and 6 of radiotherapy (RT), and at 6 weeks post-RT. The parotid volume was contoured at each scan, and the movement of the medial and lateral borders was measured. The patient's body weight was recorded at each corresponding week during RT. Regression analyses were performed to ascertain the rate of change during treatment as a percent change per fraction in parotid volume and distance relative to baseline. The mean parotid volume decreased by 37.3% from baseline to week 6 of RT. The overall rate of change in parotid volume during RT was−1.30% per fraction (−1.67% and−0.91% per fraction in≥31 Gy and<31 Gy mean planned parotid dose groups, respectively, p = 0.0004). The movement of parotid borders was greater in the≥31 Gy mean parotid dose group compared with the<31 Gy group (0.22% per fraction and 0.14% per fraction for the lateral border and 0.19% per fraction and 0.06% per fraction for the medial border, respectively). The median change in body weight was−7.4% (range, 0.75% to−17.5%) during RT. A positive correlation was noted between change in body weight and parotid volume during the course of RT (Spearman correlation coefficient, r = 0.66, p<0.01). Head and neck IMRT results in a volume loss of the parotid gland, which is related to the planned parotid dose, and the patient's weight loss during RT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric benefits of automation in the treatment of lower thoracic esophageal cancer: Is manual planning still an alternative option?

This study aimed to design automated volumetric-modulated arc therapy (VMAT) plans in Pinnacle auto-planning and compare it with manual plans for patients with lower thoracic esophageal cancer (EC). Thirty patients with lower thoracic EC were randomly selected for replanning VMAT plans using auto-planning in Pinnacle treatment planning system (TPS) version 9.10. Historical plans of these patients were then compared. Dose-volume histogram (DVH) statistics, dose uniformity, and dose homogeneity were analyzed to evaluate treatment plans. Auto-planning was superior in terms of conformity index (CI) and homogeneity index (HI) for planning target volume (PTV), significantly improving 8.2% (p = 0.013) and 25% (p = 0.007) compared with manual planning, respectively, and decreasing dose of heart and liver irradiated by 20 to 40 Gy and 5 to 30 Gy, respectively (p max ) of spinal cord by 6.9 Gy compared with manual planning (p = 0.000). Additionally, manual planning showed the significantly lower low-dose volume (V{sub 5}) for the lung (p = 0.005). For auto-planning, the V{sub 5} of the lung was significantly associated with the relative volume index (the volume ratio of PTV to the lung), and the correlation coefficient (R) and p-value were 0.994 and 0.000. Pinnacle auto-planning achieved superior target conformity and homogeneity and similar target coverage compared with historical manual planning. Most of organs at risk (OARs) sparing was significantly improved by auto-planning except for the V{sub 5} of the lung, and the low dose distribution was highly associated with PTV volume and lung volume in auto-planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical analysis of the approximate, 3-dimensional, biological effective dose equation in multiphase treatment plans

A multiphase, approximate biological effective dose (BED{sub A}) equation was introduced because most treatment planning systems (TPS) are incapable of calculating the true BED (BED{sub T}). This work investigates the accuracy and precision of the multiphase BED{sub A} relative to the BED{sub T} in clinical cases. Ten patients with head and neck cancer and 10 patients with prostate cancer were studied using their treatment plans from Pinnacle{sup 3} 9.2 (Philips Medical, Fitchburg, WI). The organs at risk (OARs) that were studied are the normal brain, left and right optic nerves, optic chiasm, spinal cord, brainstem, bladder, and rectum. BED{sub A} and BED{sub T} distributions were calculated using MATLAB 2010b (MathWorks, Natick, MA) and analyzed on a voxel basis for percent error, percent error volume histograms (PEVHs), Pearson correlation coefficient, and Bland-Altman analysis. The maximum BED values that were calculated using the BED{sub A} and BED{sub T} methods were also analyzed. BED{sub A} was found to always underestimate BED{sub T}. The accuracy and precision of BED{sub A} distributions varied between the organs: for optic chiasm and brainstem, 50% of the patients had an overall BED{sub A} percent error of A percent error of A percent error of A distributions had maximum errors ranging from 2% to 11%, with the 11% error occurring for bladder. BED{sub A} produced much more accurate maximum BED values with adjacent organs such as normal brain, bladder, and rectum. This study has shown that BED{sub A} can calculate BED distributions with acceptable accuracy under certain circumstances. However, its consistency and accuracy strongly depend on the dose distributions of the different treatment phases. One should be cautious when using BED{sub A}.

61 RADIATION PROTECTION AND DOSIMETRY↗

Documentation of Uncertainties in Experimental Cross Sections for EXFOR

Documentation of uncertainties and covariances in experimental nuclear reaction cross sections has been assessed. Following consideration of the importance of covariances for nuclear data in various nuclear applications, and presentation of a simple numerical example to demonstrate this point, the minimum basic concepts (mean, covariance, standard derivation, partial uncertainties, micro- and macro-correlation coefficients) are introduced. A deterministic approach to propagating the covariances in primary measured parameters (e.g., counts) to the derived cross sections is discussed, using a neutron-induced activation cross section measurement as an example. Finally, various approaches to documentation (publication, compilation) of experimental cross sections to facilitate their use in future evaluations are mentioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The aCORN backscatter-suppressed beta spectrometer

Backscatter of electrons from a beta detector, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron–antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. Lastly, the design, construction, calibration, and performance of the spectrometer are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗