Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cognitive IoT and Edge Computing for Intrusion Detection with Federated TinyML

Internet of Things (IoT) and Edge Computing (EC) are rapidly becoming an integral part of the modern society. By 2030, there is estimated to be over 40 billion active and connected IoT devices [1]. This rapid progress also comes with a significant implication on cybersecurity. Back-end infrastructure and systems have a much broader attack than they did previously due to vulnerable IoT/EC devices being connected to wireless networks. This expanding attack surface is a growing concern because IoT/EC are increasingly being used in critical systems such as power grids, health care, and smart homes. To effectively address a problem of this scale, cognitive cyber methods—which can autonomously detect and react to cyber attacks as they develop—are needed. To address this, we bring Artificial Intelligence (AI) and Machine Learning (ML) to IoT/EC devices, using tinyML to monitor voluminous IoT data against cyber threats, and using Federated Learning (FL) to share local detection knowledge across the system while preserving privacy. We propose a novel three-layer architecture: (1) an IoT layer for tinyML-based inference, (2) an edge layer for ML model training, and (3) a cloud layer for FL operations. Using the publicly available 11-class N-BaIoT dataset [2], we demonstrate that this architecture mitigates resource constraints at the IoT layer while improving detection accuracy over standard two-layer designs. An outlier-resistant scaler, feature reduction, and quantization enable the tinyML model to maintain detection accuracy with a reduced model size. Additionally, federated learning that only utilizes the intersection (across heterogenous devices) of the reduced feature set achieves superior detection accuracy compared to locally trained models.

Li, Mingyan [ORNL] (ORCID:0009000569532640)↗

Ensemble Federated Machine Learning‐Based Cybersecurity Situational Awareness in Microgrid Network

Cyber-physical microgrids are vulnerable to stealthy cybersecurity threats that disguise their actions through the exploitation of system knowledge. Such actions can severely impacts microgrids deployed in defense bases, slowing the response time of military forces during national emergencies. Several machine-learning algorithms have been proposed to detect intrusions in the grid networks; however, these traditional machine-learning algorithms lack data privacy and are subject to several adversarial machine-learning threats. This paper proposes a novel federated machine learning (FML)-based three-model framework to detect and identify stealthy data-integrity attacks while ensuring data privacy in microgrid networks. The proposed architecture uses a variational mode decomposition technique to extract derived features from incoming measurement and control datasets. The extraction of these derived features allows FML models to learn minute variations in data patterns that allow them to perform significantly better than the models trained with generic datasets consisting of raw features. Our experimental results show the efficient performance of the proposed methodology against different types of data integrity attacks while considering primary and secondary controllers in microgrids. Further, the applied FML-integrated random forest ensemble algorithm outperforms the existing generic FML algorithms during noisy and noise-free datasets with prediction latencies of only 91–134 µs per sample within the 0.1 s sampling interval and requires communication bandwidth of around ∼8.25 KB/s at the control center and ∼2.7 KB/s per edge client for communication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dragonstone Strategy Kickoff Report [Slides]

The oil & natural gas (ONG) system like any other heavy industrial process, relies on a complex system of information technology (IT) and operational technology (OT) devices. Cyber-preparedness varies across the ONG industry from organization to organization. Common challenges include remote locations, long-lived field assets, and insufficient capabilities to find and track malware. ONG companies tend to be concerned with lack of cyber-awareness from employees, risk stemming from remote access for operations & maintenance, and software vulnerabilities within third-party equipment. For a variety of reasons, the general consensus from stakeholders interviewed by LLNL is that the state of cybersecurity within the electric grid is currently outpacing its ONG cousin. Existing strategies for the resilience and cybersecurity of the electric grid can and should be leveraged to provide immediate benefits to the ONG system. In LLNL’s view, there are two key factors currently limiting the development of necessary cyber-practices within the ONG industry: regulatory overlap and inefficiencies, and lack of industry awareness of potentially useful technologies for solving known issues. In the months following this report, LLNL will develop a cyber-resilience roadmap for the oil & gas pipeline sector, coupling threat intelligence, industry knowledge base, and ongoing outreach

02 PETROLEUM↗

Bayesian GAN-Based False Data Injection Attack Detection in Active Distribution Grids With DERs

Advancements in information and communication technologies have revolutionized monitoring and control capabilities within smart grids. However, it also brings new vulnerabilities to data acquisition systems and state estimation functions, which attackers can subtly tamper with the measurement data through compromising the communication network. Moreover, the high penetration of renewable energy sources with the inherited characteristics of uncertainty and variability further complicates the design of effective intrusion detection systems. In this paper, a Bayesian deep learning-based approach is developed to detect cyber attacks and maintain the security of smart grids. Our method specifically addresses the prevalent issue of imbalanced data in real power systems, which arises from the predominance of normal system operations over compromised or attacked states. Employing a novel Bayesian GAN-based technique, our approach successfully discriminates between secure and compromised measurement data, even in scenarios with significant data imbalance. Furthermore, the proposed method accommodates various practical application factors, ensuring accurate intrusion detection despite the presence of measurement noise. The feasibility and effectiveness of the proposed detection mechanism are validated by testing on IEEE 13-node and 123-node test systems. Simulation results and comparisons with literature methods demonstrate the superiority of proposed cybersecurity solutions.

Bayesian GAN↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Modeling Cyber Supply Chain Incidents with Multilayered Graph Motifs

As noted within the literature, supply chain includes people and organizations---manufacturers, integrators, and third-party vendors---that are involved in one or more stages of a product lifecycle. Since supply chains, by definition, include organizations and people, supply chain risk management activities must consider dependencies between an organization's business processes and third-party resources. Just as adversarial tactics can be implemented via techniques implemented via networked computer systems, so can such tactics be expressed via legal business relationships. A cyber incident may have an exponential impact downstream, for example, by leveraging a product's distribution channel (e.g. malicious updates in SolarWinds, buggy updates in CrowdStrike). Similarly, legitimate and legal business relationships also affect the attack surface exposure of systems, enabling long-term persistence and/or unknown impacts to product quality that are hard to detect. This paper catalogs several recent digital supply chain incidents and applies a multilayered network formalism to develop structural indicators (graph motifs) that reflect potentially-adversarial behavior. Finally, we compare and contrast the characteristics of adversarial tactics (e.g. Loss of Availability, Data Collection) that leverage cyber-physical dependencies to those that leverage legal organizational relationships.

97 - MATHEMATICS AND COMPUTING↗

Thermal Actuator Identification and Control for Thermomechanical Real-Time Cyber–Physical Testing

Thermomechanical cyber–physical testing enables two-way thermal coupling between a numerical and an experimental subsystem. The interactions between the numerical model and the physical specimen occur through transfer systems, which enforce interface conditions. Thus, efficient control methodologies are necessary to achieve the desired interface interaction through thermal actuators with minimal error. This study introduces a novel thermal transfer system that imposes distributed cooling (or heating) thermal loads on a physical subsystem. First, the thermal actuator is identified considering switching-mode continuous dynamics for heating and cooling conditions. A switching-mode estimation algorithm is adopted to estimate the operating thermal cycle of the actuator in real-time. A control system is developed to experimentally impose the desired temperature and reduce tracking error (i.e., the error between the desired and actual temperature) under different thermal cycles. The identification and control of the thermal transfer system are then validated through a set of experiments considering different temperature rates of change. The developed control system is found to effectively minimize tracking errors in real-time cyber–physical experiments.

Herta Montoya↗

Optimal design of structures with multiple design variables per group and multiple loading conditions on the personal computer

A finite element based programming system for minimum weight design of a truss-type structure subjected to displacement, stress, and lower and upper bounds on design variables is presented. The programming system consists of a number of independent processors, each performing a specific task. These processors, however, are interfaced through a well-organized data base, thus making the tasks of modifying, updating, or expanding the programming system much easier in a friendly environment provided by many inexpensive personal computers. The proposed software can be viewed as an important step in achieving a 'dummy' finite element for optimization. The programming system has been implemented on both large and small computers (such as VAX, CYBER, IBM-PC, and APPLE) although the focus is on the latter. Examples are presented to demonstrate the capabilities of the code. The present programming system can be used stand-alone or as part of the multilevel decomposition procedure to obtain optimum design for very large scale structural systems. Furthermore, other related research areas such as developing optimization algorithms (or in the larger level: a structural synthesis program) for future trends in using parallel computers may also benefit from this study.

Nguyen, D. T.↗

Advanced Transmission Technologies –GETs and HPCs Session 3: HPCs and Building Actions Plans to Digital Assurance Risks

The third session of the Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program, held on November 11, 2025, centered on High Performance Conductors (HPCs) and the formulation of action plans to address digital assurance risks associated with Grid-Enhancing Technologies (GETs). This session convened experts from utilities, vendors, and government agencies to examine the technical, operational, and cybersecurity aspects of HPC deployment. Discussions highlighted the benefits of HPCs, such as their ability to rapidly increase transmission capacity using existing corridors, improve grid resilience, reduce system losses, and align with FERC Orders 2023 and 1920. Participants evaluated supply chain and digital assurance risks, including reliance on imported materials, limited domestic manufacturing capacity, workforce shortages, and traceability issues. The session also emphasized the importance of digital trust, integration-layer cybersecurity, and unified risk frameworks, introducing tools like intrusion detection systems, encryption, zero trust networking, and firmware integrity. Recaps of earlier workshops on Dynamic Line Ratings (DLRs), Advanced Power Flow Control (APFC), and Transmission Topology Optimization (TTO) underscored institutional barriers and integration challenges. Action plans were proposed to mitigate issues such as inconsistent cybersecurity practices, SBOM usage, supply chain visibility, operator trust, and misaligned incentives. Additionally, INL presented its supply chain risk management tools and Cyber-Informed Engineering (CIE) principles to support secure procurement and system design. The session concluded with a commitment to share key takeaways, incorporate cohort feedback into future policy development, and continue collaborative engagement through upcoming pilot activities. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Fossil Power Plant Cyber Security Life-Cycle Risk Reduction, A Practical Framework for Implementation

Market conditions are forcing fossil electricity generation facility owners and operators to implement advanced digital technologies. These technologies enable efficiencies, operational flexibility, operations and maintenance efficiencies, and adapting to a transitioning workforce. These digital technologies, however, can increase the cybersecurity attack surface. The purpose of this research was to develop a holistic cybersecurity risk reduction framework for fossil generation facilities. The framework begins with assessing how cyber risk changes across facility life cycles, including plant, system, vendor, and business life cycles. The next phase performs consequence analysis to prioritize high consequence events. Focusing on high consequence events allows owners to use a graded, risk-informed approach to prioritize cybersecurity efforts. The final phase identifies the digital asset attack surface in sensors and instrumentation and control equipment. After the vulnerabilities are identified, the owner selects mitigating cybersecurity control measures (or countermeasures) based on the risk analysis from the previous phases. This report describes the current industry cybersecurity best practices in fossil generation that are based on the first principles for cybersecurity engineering. The report is divided into five sections that describe the implementation of the risk reduction framework and present identified research, methodological, and technology gaps that were identified through this course of research and development.

01 COAL, LIGNITE, AND PEAT↗

Cyber-Enabled Sabotage, Critical Function Assurance, and Cyber-Informed Engineering

Cyber-enabled Sabotage, Critical Function Assurance, and Cyber-Informed Engineering: This discussion will introduce the idea of cyber-enabled sabotage, and the role engineering plays in the cyber defense of critical functions with a focus on electric power systems. It will outline how and why engineering practice must be used to apply cybersecurity principles to establish safe and reliable operations even in the face of determined and skilled adversaries, and give an overview of INL’s Consequence-Driven Cyber-Informed Engineering methodology to apply these principles. There will be an opportunity for audience questions and answers at the end of the session.

42 ENGINEERING↗

Cyber-Informed Engineering: Incorporating CIE into Engineering Curricula

Cyber-Informed Engineering (CIE) is an engineering approach that mitigates the consequences of cyber risk to critical infrastructure by integrating engineered controls into system design and operation. CIE-focused education is necessary to prepare future engineers and technicians to understand and mitigate digital risk in modern engineered systems. This session explores how universities can incorporate CIE into their curricula, provides examples of how existing universities are already leveraging CIE in their programs, and highlights resources to support adoption.

99 - GENERAL AND MISCELLANEOUS↗

Total Power Factor Smart Contract with Cyber Grid Guard Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Wind Farm

In modern electrical grids, the numbers of customer-owned distributed energy resources (DERs) have increased, and consequently, so have the numbers of points of common coupling (PCC) between the electrical grid and customer-owned DERs. The disruptive operation of and out-of-tolerance outputs from DERs, especially owned DERs, present a risk to power system operations. A common protective measure is to use relays located at the PCC to isolate poorly behaving or out-of-tolerance DERs from the grid. Ensuring the integrity of the data from these relays at the PCC is vital, and blockchain technology could enhance the security of modern electrical grids by providing an accurate means to translate operational constraints into actions/commands for relays. This study demonstrates an advanced power system application solution using distributed ledger technology (DLT) with smart contracts to manage the relay operation at the PCC. The smart contract defines the allowable total power factor (TPF) of the DER output, and the terms of the smart contract are implemented using DLT with a Cyber Grid Guard (CGG) system for a customer-owned DER (wind farm). This article presents flowcharts for the TPF smart contract implemented by the CGG using DLT. The test scenarios were implemented using a real-time simulator containing a CGG system and relay in-the-loop. The data collected from the CGG system were used to execute the TPF smart contract. The desired TPF limits on the grid-side were between +0.9 and +1.0, and the operation of the breakers in the electrical grid and DER sides was controlled by the relay consistent with the provisions of the smart contract. The events from the real-time simulator, CGG, and relay showed a successful implementation of the TPF smart contract with CGG using DLT, proving the efficacy of this approach in general for implementing electrical grid applications for utilities with connections to customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Survey of Cyber Threat

Multiple companies are competing to develop human-crewed and unmanned aerial vehicles to provide flight in urban environments. With the growth of aerial systems and future airborne vehicle networks and the need to enable secure data exchange and service interactions within Urban Air Mobility (UAM) environments, cybersecurity has come to the forefront as a topic, highlighting the need to protect these networks from cyber-attacks. This paper will identify potential threats, vulnerabilities, and weaknesses of UAM environments, that could lead to system compromises and disruptions.

Cyber Security↗

Advancing Electric System Resilience with Distributed Energy Resources: A Review of State Policies

Severe weather, cyber-attacks, geomagnetic disturbances, and other hazards and threats have caused or have the potential to cause substantial levels of damage to electricity infrastructure and the global economy. Growth in distributed energy resources (DERs) and increasing attention to the resilience of the electric grid - its ability to "anticipate, absorb, adapt to, and/or rapidly recover" from disruptions, according to the Federal Energy Regulatory Commission (FERC, 2018) - have created an opportunity for energy stakeholders to develop and deploy "resilient DERs," resources in the distribution grid that improve the ability of a customer, critical facility, and/or the distribution system in general to anticipate, absorb, adapt to, and/or rapidly recover from disruptions. This paper explores how existing state regulations intersect with resilience and highlights opportunities where state regulators can employ DERs to advance resilience.

14 SOLAR ENERGY↗