Search NASA⌕ Search

SEARCH · Search NASA

Results for “data aggregation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Impact of Data Placement on Resilience in Large-Scale Object Storage Systems

Distributed object storage architectures have become the de facto standard for high-performance storage in big data, cloud, and HPC computing. Object storage deployments using commodity hardware to reduce costs often employ object replication as a method to achieve data resilience. Repairing object replicas after failure is a daunting task for systems with thousands of servers and billions of objects, however, and it is increasingly difficult to evaluate such scenarios at scale on realworld systems. Resilience and availability are both compromised if objects are not repaired in a timely manner. In this work we leverage a high-fidelity discrete-event simulation model to investigate replica reconstruction on large-scale object storage systems with thousands of servers, billions of objects, and petabytes of data. We evaluate the behavior of CRUSH, a well-known object placement algorithm, and identify configuration scenarios in which aggregate rebuild performance is constrained by object placement policies. After determining the root cause of this bottleneck, we then propose enhancements to CRUSH and the usage policies atop it to enable scalable replica reconstruction. We use these methods to demonstrate a simulated aggregate rebuild rate of 410 GiB/s (within 5% of projected ideal linear scaling) on a 1,024-node commodity storage system. We also uncover an unexpected phenomenon in rebuild performance based on the characteristics of the data stored on the system.

Carns, Philip↗

Wireless Sensor Network for Electric Transmission Line Monitoring

Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8).

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE EV Data Collection - Charging Data

Charging data are collected from one of three sources, each with varying levels of additional information. These sources, in approximate order from most to least additional information, are: • The electric vehicle supply equipment (charger) • Onboard the vehicle itself • From a utility submeter. Many chargers provide software that allows for the collection and reporting of charging session data. If unavailable, data may be recorded by the charging vehicle’s onboard systems. If neither of these options is available, data can be acquired from utility submeters that simply track the energy flowing to one or more chargers. Data collected directly from the electric vehicle supply equipment (EVSE) are typically the most accurate and highest frequency. However, it is not always possible to discern which exact vehicle is being charged during any one session. EVSE-side data can be identified where a single charger ID but a range of vehicle IDs are present (e.g., CH001, EV001-EV005). Data collected from the vehicle’s onboard systems usually does not provide information on which exact charger is being used. Vehicle-side data can be identified where a single Vehicle ID but a range of Charger IDs are present (e.g., EV001, CH001-CH005). Data collected from utility submeters provide no information on which specific vehicle is charging or which specific charger is in use. Submeter data can be identified where multiple Vehicle IDs and multiple Charger IDs are present, but only a single Fleet ID is present (e.g., EV001-EV005, CH001-CH005, Fleet01). The **Charge Data Daily/Session Dictionaries** contains definitions for each available parameter collected as part of an individual charging session, aggregated at either a daily or session level. The parameters available will vary between vehicles and chargers. The **Charger Attributes** table contains specific charger characteristics, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. The **Charger Attributes Data Dictionary** contains definitions for each available parameter collected on the physical and operational characteristics of the charging hardware itself. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables, and in cases where charging data are supplied, links a vehicle with the charger(s) that supplied it power. The **Charging Data** tables contain the data from each charger’s operations, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel mouse model of enhanced proteostasis: Full-length human heat shock factor 1 transgenic mice

Research highlights: {yields} Development of mouse overexpressing native human HSF1 in all tissues including CNS. {yields} HSF1 overexpression enhances heat shock response at whole-animal and cellular level. {yields} HSF1 overexpression protects from polyglutamine toxicity and favors aggresomes. {yields} HSF1 overexpression enhances proteostasis at the whole-animal and cellular level. -- Abstract: The heat shock response (HSR) is controlled by the master transcriptional regulator heat shock factor 1 (HSF1). HSF1 maintains proteostasis and resistance to stress through production of heat shock proteins (HSPs). No transgenic model exists that overexpresses HSF1 in tissues of the central nervous system (CNS). We generated a transgenic mouse overexpressing full-length non-mutant HSF1 and observed a 2-4-fold increase in HSF1 mRNA and protein expression in all tissues studied of HSF1 transgenic (HSF1{sup +/0}) mice compared to wild type (WT) littermates, including several regions of the CNS. Basal expression of HSP70 and 90 showed only mild tissue-specific changes; however, in response to forced exercise, the skeletal muscle HSR was more elevated in HSF1{sup +/0} mice compared to WT littermates and in fibroblasts following heat shock, as indicated by levels of inducible HSP70 mRNA and protein. HSF1{sup +/0} cells elicited a significantly more robust HSR in response to expression of the 82 repeat polyglutamine-YFP fusion construct (Q82YFP) and maintained proteasome-dependent processing of Q82YFP compared to WT fibroblasts. Overexpression of HSF1 was associated with fewer, but larger Q82YFP aggregates resembling aggresomes in HSF1{sup +/0} cells, and increased viability. Therefore, our data demonstrate that tissues and cells from mice overexpressing full-length non-mutant HSF1 exhibit enhanced proteostasis.

60 APPLIED LIFE SCIENCES↗

The small molecule 2-phenylethynesulfonamide induces covalent modification of p53

p53 is a tumor suppressor protein which is either lost or inactivated in a large majority of tumors. The small molecule 2-phenylethynesulfonamide (PES) was originally identified as the inhibitor of p53 effects on the mitochondrial death pathway. In this report we demonstrate that p53 protein from PES-treated cells was detected in reduced mobility bands between molecular weights 95–220 kDa. Resolution of p53 aggregates on urea gel was unable to reduce the high molecular weight p53 aggregates, which were shown to be primarily located in the nucleus. Therefore, our data suggest that PES exerts its effects through covalent cross-linking and nuclear retention of p53. - Highlights: • p53 protein is in high molecular weight complexes in the nucleus of PES-treated cells. • PES is a drug that inhibits pro-apoptotic p53 action at the mitochondria. • We propose that PES action involves cross-linking and nuclear retention of p53.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compound Continental Risk of Multiple Extreme Floods in the United States

Abstract Understanding spatially correlated floods and modeling joint hazard associated with threshold exceedances across multiple locations is crucial for accurate estimation of continental‐scale portfolio risk. This work uses a non‐parametric copula‐based spatial simulator to analyze peak floods across the United States to derive the first‐of‐its‐kind continental portfolio risk estimates at the 10‐ and 100‐year return levels. We find significant interdependence in floods across the nation, revealing the recurring pattern of extreme events affecting the Northeast, Central, West, and Northwest United States in the same year. The stochastic simulator effectively manages high‐dimensional data and offers reliable uncertainty estimates for both spatially dependent floods and the aggregated flood losses at the continental level. El Niño‐Southern Oscillation and Atlantic Multidecadal Oscillation are identified as statistically significant tele‐connectors of aggregate loss. This research aims to advance the understanding of compound continental flood hazard and the potential large‐scale climate teleconnections that lead to such compound floods.

Geology↗

Architecture and Implementation of OpenPET Firmware and Embedded Software

OpenPET is an open source, modular, extendible, and high-performance platform suitable for multi-channel data acquisition and analysis. Due to the versatility of the hardware, firmware, and software architectures, the platform is capable of interfacing with a wide variety of detector modules not only in medical imaging but also in homeland security applications. Analog signals from radiation detectors share similar characteristics-a pulse whose area is proportional to the deposited energy and whose leading edge is used to extract a timing signal. As a result, a generic design method of the platform is adopted for the hardware, firmware, and software architectures and implementations. The analog front-end is hosted on a module called a Detector Board, where each board can filter, combine, timestamp, and process multiple channels independently. The processed data is formatted and sent through a backplane bus to a module called Support Board, where 1 Support Board can host up to eight Detector Board modules. The data in the Support Board, coming from 8 Detector Board modules, can be aggregated or correlated (if needed) depending on the algorithm implemented or runtime mode selected. It is then sent out to a computer workstation for further processing. The number of channels (detector modules), to be processed, mandates the overall OpenPET System Configuration, which is designed to handle up to 1,024 channels using 16-channel Detector Boards in the Standard System Configuration and 16,384 channels using 32-channel Detector Boards in the Large System Configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative differentiation of benign and misfolded glaucoma-causing myocilin variants on the basis of protein thermal stability

Accurate predictions of the pathogenicity of mutations associated with genetic diseases are key to the success of precision medicine. Inherited missense mutations in the myocilin (MYOC) gene, within its olfactomedin (OLF) domain, constitute the strongest genetic link to primary open-angle glaucoma via a toxic gain of function, and thus MYOC is an attractive precision-medicine target. However, not all mutations in MYOC cause glaucoma, and common variants are expected to be neutral polymorphisms. The Genome Aggregation Database (gnomAD) lists ~100 missense variants documented within OLF, all of which are relatively rare (allele frequency <0.001%) and nearly all are of unknown pathogenicity. To distinguish disease-causing OLF variants from benign OLF variants, we first characterized the most prevalent population-based variants using a suite of cellular and biophysical assays, and identified two variants with features of aggregation-prone familial disease variants. Next, we considered all available biochemical and clinical data to demonstrate that pathogenic and benign variants can be differentiated statistically based on a single metric: the thermal stability of OLF. Our results motivate genotyping MYOC in patients for clinical monitoring of this widespread, painless and irreversible ocular disease.

59 BASIC BIOLOGICAL SCIENCES↗

Quantifying albedo susceptibility biases in shallow clouds

The evaluation of radiative forcing associated with aerosol–cloud interactions remains a significant source of uncertainty in future climate projections. The problem is confounded by the fact that aerosol particles influence clouds locally and that averaging to larger spatial and/or temporal scales carries biases that depend on the heterogeneity and spatial correlation of the interacting fields and the nonlinearity of the responses. Mimicking commonly applied satellite data analyses for calculation of albedo susceptibility S o , we quantify S o aggregation biases using an ensemble of 127 large eddy simulations of marine stratocumulus. We explore the cloud field properties that control this spatial aggregation bias and quantify the bias for a large range of shallow stratocumulus cloud conditions manifesting a variety of morphologies and ranges of cloud fractions. We show that S o spatial aggregation biases can be on the order of hundreds of percent, depending on the methodology. Key uncertainties emanate from the typically applied adiabatic drop concentration N d retrieval, the correlation between aerosol and cloud fields, and the extent to which averaging reduces the variance in cloud albedo A c and N d . So biases are more often positive than negative and are highly correlated with biases in the liquid water path adjustment. Temporal aggregation biases are shown to offset spatial aggregation biases. Both spatial and temporal biases have significant implications for observationally based assessments of aerosol indirect effects and our inferences of underlying aerosol–cloud–radiation effects.

54 ENVIRONMENTAL SCIENCES↗

V1G Frequency Regulation: Algorithm Development, Validation & Analysis at Scale

Researchers at Argonne National Laboratory developed and validated a high-fidelity digital twin of a smart charging (V1G) ecosystem to model the participation of up to 1,000 unique electric vehicles (EVs) in the PJM frequency regulation market. Utilizing a discrete-event framework, the simulation models complex interactions, from dynamic grid signals (updated every 2 seconds) to individual EV charging dynamics. The simulation incorporates multiple EV models created from real-world lab test data. Researchers tested multiple control algorithms to balance the dual objectives of maximizing aggregator’s revenue and driver charging needs. Results demonstrate that aggregated EVs function as a controllable, highly effective grid resource, achieving high PJM Performance Scores (80–90%). Additionally, an optimized, market-aware bidding strategy was identified as key to profitability. The platform was shown to provide drivers with an average charging discount of nearly 50%. The algorithm was further validated in the lab using production EVs and charging stations to compare simulation results with real-world performance.

Manne, Nithin↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders: Preprint

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automatic identification and classification of Palomar Transient Factory astrophysical objects in GLADE

Palomar Transient Factory (PTF) is a comprehensive detection system for the identification and classification of transient astrophysical objects. In this paper, we make two significant contributions to the PTF pipeline. First, we present an experimental study that evaluates a novel implementation of the real-time classifier in GLADE - a parallel data processing system that combines the efficiency of a database with the extensibility of map-reduce. We show how each stage in the classifier maps optimally into GLADE tasks by taking advantage of the unique features of the system - range-based data partitioning, columnar storage, multi-query execution, and in-database support for complex aggregate computation. Second, we introduce a novel parallel similarity join algorithm for advanced transient classification. In conclusion, we implement this algorithm in GLADE and execute it on a massive supercomputer with more than 3,000 threads, achieving more than three orders of magnitude improvement over the PostgreSQL solution.

79 ASTRONOMY AND ASTROPHYSICS↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Determination Quantitative Analysis

The U.S. Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society of North America (IESNA) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/IESNA Standard 90.1-2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The final analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1-2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE's final determination. However, out of the 109 addenda, 34 were preliminarily determined to have a measureable and quantifiable impact. A suite of 240 computer energy simulations for building prototypes complying with ASHRAE 90.1-2007 was developed. These prototypes were then modified in accordance with these 34 addenda to create a second suite of corresponding building simulations reflecting the same buildings compliant with Standard 90.1-2010. The building simulations were conducted using the DOE EnergyPlus building simulation software. The resulting energy use from the complete suite of 480 simulation runs was then converted to energy use intensity (EUI, or energy use per unit floor area) metrics (Site EUI, Primary EUI, and energy cost intensity [ECI]) results for each simulation. For each edition of the standard, these EUIs were then aggregated to a national basis for each prototype using weighting factors based on construction floor area developed for each of the 15 U.S. climate zones using commercial construction data. When compared, the resulting weighted EUIs indicated that each of the 16 building prototypes used less energy under Standard 90.1-2010 than under Standard 90.1-2007 on a national basis when considering site energy, primary energy, or energy cost. The EUIs were also aggregated across building types to a national commercial building basis using the same weighting data. On a national basis, the final quantitative analysis estimated a floor-space-weighted national average reduction in new building energy consumption of 18.2 percent for source energy and 18.5 percent when considering site energy. An 18.2 percent savings in energy cost, based on national average commercial energy costs for electricity and natural gas, was also estimated.

03 NATURAL GAS↗

ANSI/ASHRAE/IES Standard 90.1-2010 Final Determination Quantitative Analysis

The U.S. Department of Energy (DOE) conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the American National Standards Institute (ANSI)/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)/Illuminating Engineering Society (IES) Standard 90.1-2010 (ASHRAE Standard 90.1-2010, Standard 90.1-2010, or 2010 edition) would result in energy savings compared with buildings constructed to ANSI/ASHRAE/Illuminating Engineering Society of North America (IESNA) Standard 90.1- 2007(ASHRAE Standard 90.1-2007, Standard 90.1-2007, or 2007 edition). The final analysis considered each of the 109 addenda to ASHRAE Standard 90.1-2007 that were included in ASHRAE Standard 90.1- 2010. All 109 addenda processed by ASHRAE in the creation of Standard 90.1-2010 from Standard 90.1-2007 were reviewed by DOE, and their combined impact on a suite of 16 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 109 addenda, 34 were preliminarily determined to have a measureable and quantifiable impact. A suite of 240 computer energy simulations for building prototypes complying with ASHRAE 90.1- 2007 was developed. These prototypes were then modified in accordance with these 34 addenda to create a second suite of corresponding building simulations reflecting the same buildings compliant with Standard 90.1-2010. The building simulations were conducted using the DOE EnergyPlus building simulation software. The resulting energy use from the complete suite of 480 simulation runs was then converted to energy use intensity (EUI, or energy use per unit floor area) metrics (Site EUI, Primary EUI, and energy cost intensity [ECI]) results for each simulation. For each edition of the standard, these EUIs were then aggregated to a national basis for each prototype using weighting factors based on construction floor area developed for each of the 15 U.S. climate zones using commercial construction data. When compared, the resulting weighted EUIs indicated that each of the 16 building prototypes used less energy under Standard 90.1-2010 than under Standard 90.1-2007 on a national basis when considering site energy, primary energy, or energy cost. The EUIs were also aggregated across building types to a national commercial building basis using the same weighting data. On a national basis, the final quantitative analysis estimated a floor-space-weighted national average reduction in new building energy consumption of 18.2 percent for source energy and 18.5 percent when considering site energy. An 18.2 percent savings in energy cost, based on national average commercial energy costs for electricity and natural gas, was also estimated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medium controlled aggregative growth as a key step in mesoporous silica nanoparticle formation

Near monodisperse mesoporous silica nanoparticles (MSN) represent a promising and rapidly developing type of mesoporous silica materials; however, the vast data on their synthesis remains unorganized and ill-understood. We systematically studied the formation of MSN under basic and neutral conditions using various temperatures, CTAB concentrations, hydrolyzing agents (triethanolamine, ammonia, phosphate buffers), and media with different colloidal stabilization properties (with ethanol as a cosolvent and monovalent salts). In the typical conditions for the preparation of stable MSN colloids, the particle size was controlled by colloidal stabilization by the medium (solvent type, ionic strength, and surfactant concentration) in agreement with the “aggregative growth” mechanism, rather than by solely the hydrolysis and condensation rates conventionally used for data interpretation in the classical nucleation theory. Medium properties (pH, ion types and concentration, polarity) also defined the efficiency of silica-surfactant cooperative self-assembly, which directly affected the porosity, mesopore size and pore wall thickness. Interestingly, this traditional silica-surfactant route showed a limited effect on the particle size, emphasizing the dominating role of colloidal stabilization in the studied reaction conditions. In situ pH measurements showed that every reaction medium has unique pH evolution profiles depending on the buffer capacity, hydrolysis and condensation rates. Reaction systems that fail to maintain the working pH can lead to non-porous products or undesired particle morphology and size distribution. The established particle formation mechanism allowed us to formulate comprehensive guidelines for preparing relatively concentrated colloids of near monodisperse (PDI 5–15%) mesoporous 30–700 nm silica spheres with variable porosity and mesopore size. Here, these findings will be particularly useful in designing new mesoporous silica-containing materials for biomedical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elastic Moduli and Strength of Nanocrystalline Cubic BC2N from X-ray Diffraction Under Nonhydrostatic Compression

The stress behavior of nanocrystalline cubic boron carbon nitride (c-BC2N) was investigated using radial and axial x-ray diffractions in the diamond-anvil cell under nonhydrostatic compression up to {approx}100 GPa. The radial x-ray diffraction (RXRD) data yield a bulk modulus K0=276{+-}20 GPa with a fixed pressure derivative K0{prime}=3.4 at {psi}=54.7, which corresponds to the hydrostatic compression curve. The bulk modulus obtained from axial x-ray diffraction (AXRD) gives a value of 420{+-}11 GPa. A comparative study of the observed compression curves from radial and axial diffractions shows that the ruby-fluorescence pressure scale may reflect the maximum stress under nonhydrostatic compression. It was found that nanocrystalline c-BC2N sample could support a maximum differential stress of {approx}38 GPa when it started to yield at {approx}66 GPa under uniaxial compression. Moreover, the aggregate elastic moduli of the nanocrystalline c-BC2N have been determined from the RXRD data at high pressures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Target diagnostic control system implementation for the National Ignition Facility (invited)

The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗