Search NASA⌕ Search

SEARCH · Search NASA

Results for “device testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Plant Mounds as Concentration and Stabilization Agents for Actinide Soil Contaminants in Nevada

Plant mounds or blow-sand mounds are accumulations of soil particles and plant debris around the base of shrubs and are common features in deserts in the southwestern United States. An important factor in their formation is that shrubs create surface roughness that causes wind-suspended particles to be deposited and resist further suspension. Shrub mounds occur in some plant communities on the Nevada Test Site, the Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR), including areas of surface soil contamination from past nuclear testing. In the 1970s as part of early studies to understand properties of actinides in the environment, the Nevada Applied Ecology Group (NAEG) examined the accumulation of isotopes of Pu, 241Am, and U in plant mounds at safety experiment and storage-transportation test sites of nuclear devices. Although aerial concentrations of these contaminants were highest in the intershrub or desert pavement areas, the concentration in mounds were higher than in equal volumes of intershrub or desert pavement soil. The NAEG studies found the ratio of contaminant concentration of actinides in soil to be greater (1.6 to 2.0) in shrub mounds than in the surrounding areas of desert pavement. At Project 57 on the NTTR, 17 percent of the area was covered in mounds while at Clean Slate III on the TTR, 32 percent of the area was covered in mounds. If equivalent volumes of contaminated soil were compared between mounds and desert pavement areas at these sites, then the former might contain as much as 34 and 62 percent of the contaminant inventory, respectively. Not accounting for radionuclides associated with shrub mounds would cause the inventory of contaminants and potential exposure to be underestimated. In addition, preservation of shrub mounds could be important part of long-term stewardship if these sites are closed by fencing and posting with administrative controls.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Using Explainable Artificial Intelligence to Predict Perovskite Solar Cell Electrical Metastability from Operando Photoluminescence Images in Accelerated Stress Testing

Metal halide perovskite (MHP) solar cells exhibit a metastable response to bias governed by coupled ionic–electronic processes, complicating the conventional reciprocity relation between luminescence intensity and device open-circuit voltage (V oc ). This limits the use of luminescence as a diagnostic for device screening or accelerated stress testing, motivating new approaches that can interpret photoluminescence (PL) signals under nonequilibrium conditions. From the artificial intelligence perspective, we develop an explainable deep learning framework that integrates convolutional neural networks (CNN), long short-term memory (LSTM) layers, and an attention mechanism to learn spatiotemporal features from operando photoluminescence PL image sequences. The model achieves a mean absolute error of ±0.027 V in predicting open-circuit voltage transients and reduces extreme-tail errors by up to 78% compared to physics-based reciprocity calculations. Gradient-weighted Class Activation Mapping (Grad-CAM) provides interpretability by highlighting physically meaningful regions such as electrode edges and emergent defect features. From the engineering application perspective, this framework enables accurate, contactless prediction of device V oc and identification of degradation-relevant features during accelerated aging of perovskite solar cells. This approach demonstrates how explainable AI can enhance operando diagnostics and reliability analysis in photovoltaic devices under nonequilibrium conditions.

14 SOLAR ENERGY↗

Device Engineering Towards Improved Tin Sulfide Solar Cell Performance and Performance Reproducibility

As novel absorber materials are developed and screened for their photovoltaic (PV) properties, the challenge remains to rapidly test promising candidates in high-performing PV devices. There is a need to engineer new compatible device architectures, including the development of novel transparent conductive oxides and buffer layers. Here, we consider the two approaches of a substrate-style and a superstrate-style device architecture for novel thin-film solar cells. We use tin sulfide as a test absorber material. Upon device engineering, we demonstrate new approaches to improve device performance and performance reproducibility.

14 SOLAR ENERGY↗

A multichannel, real-time MRI RF power monitor for independent SAR determination

Purpose: Accurate measurements of the RF power delivered during clinical MRI are essential for safety and regulatory compliance, avoiding inappropriate restrictions on clinical MRI sequences, and for testing the MRI safety of peripheral and interventional devices at known RF exposure levels. The goal is to make independent RF power measurements to test the accuracy of scanner-reported specific absorption rate (SAR) over the extraordinary range of operating conditions routinely encountered in MRI. Methods: A six channel, high dynamic range, real-time power profiling system was designed and built for monitoring power delivery during MRI up to 440 MHz. The system was calibrated and used in two 3 T scanners to measure power applied to human subjects during MRI scans. The results were compared with the scanner-reported SAR. Results: The new power measurement system has highly linear performance over a 90 dB dynamic range and a wide range of MRI duty cycles. It has about 0.1 dB insertion loss that does not interfere with scanner operation. The measurements of whole-body SAR in volunteers showed that scanner-reported SAR was significantly overestimated by up to about 2.2 fold. Conclusions: The new power monitor system can accurately and independently measure RF power deposition over the wide range of conditions routinely encountered during MRI. Scanner-reported SAR values are not appropriate for setting exposure limits during device or pulse sequence testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Application of A Membrane-Based Thermodenuder for Measurement of Volatile Particles Emitted by A Jet Turbine Engine

Measurement of volatile particles emitted by modern jet engines is a daunting task. Besides the complexity in sampling jet aircraft exhaust, the main difficulty lies at how to faithfully capture the phase-partition dynamics of volatile particles as they travel downstream from the engine exhaust nozzle. As a result, the physico-chemical properties of the exhaust are also transformed. We have developed a sampling instrument that aims at enabling study of the phase-partition dynamics. The objective of this research project was to design and evaluate a new thermodenuder for performing phase separation of the engine-emitted volatile particles. The backbone of the new thermodenuder is a thin metallic membrane. The membrane enables extraction of molecules that can be thermally desorbed from the condensed particulate phases and collected for subsequent chemical analysis. Toward realization of the technique in the future field aircraft emissions measurement we tested this new thermo-denuding device using laboratory-generated particles that were made of non-volatile or semi-volatile chemicals. The particle penetration efficiency, a measure of the device performance, of this thermodenuder was found to be better than 99%. Results obtained from the tests executed at a number of operating temperature conditions show reasonably good thermal separation. We have scheduled to apply this new device to characterize emissions from a T63 turboshaft engine in the spring of 2010 and are expecting to show the engine results at the conference. The test results based on the laboratory-generated particles were encouraging for the intended application. With excellent particle transmission efficiency and an ability to simultaneously measure the composition in the gas and particle phases of the engine particles, we believe the new technology will make a great contribution to measurement research of engine emissions.

47 OTHER INSTRUMENTATION↗

A Domestic Program for Liquid Metal PFC Research in Fusion

While high-Z solid plasma-facing components (PFCs) are the leading candidates for reactors, it is unclear that they can survive the intense plasma material interaction (PMI). Liquid metals (LM) PFCs offer potential solutions since they are not susceptible to the same type of damage, and can be “self-healing”. Following the Fusion Energy System Study on Liquid Metal Plasma Facing Components study that recently was completed by Kessel et al. (Fusion Sci Technnol 75:886, 2019) a domestic LM PFC design program has been initiated to develop reactor-relevant LM PFC concepts. This program seeks to evaluate LM PFC concepts for a Fusion Nuclear Science Facility (FNSF) or a Compact Pilot Plant via engineering design calculations, modeling of PMI and PFC components and laboratory experiments. The latter involves experiments in dedicated test stands and confinement devices and seeks to identify and answer open questions in LM PFC design. The new national LM PFC program is first investigating lithium as the plasma facing material for a flowing divertor PFC concept. Several flow speeds will be evaluated, ranging from ~ cm/s to m/s. The surface temperature will initially be held below the strongly evaporative limit in the first design; higher temperatures with strong evaporation will be considered in future concepts. Other topics of interest include: understanding of the hydrogen and helium interaction with the liquid lithium; single effect experiments on wetting, compatibility and embrittlement; and prototypical experiments for control and characterization of flowing LM. A path to plasma and future tokamak exposure of these concepts will be developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current research in low temperature proton exchange membrane-based electrolysis and a necessary shift in focus

While hydrogen has limited use in energy markets today, significant growth is possible in grid storage and as an energy carrier in other sectors. Along with lower electricity prices, further hydrogen cost reduction can enable electrochemical water splitting, particularly as the use of intermittent, renewable power sources increases and the quantity and duration of storage requirements limit electrical storage options. With the improved viability of large-scale hydrogen production, research in low temperature electrolysis has dramatically increased. The overwhelming majority of research efforts within proton exchange membrane-based systems has focused on catalyst development, although a smaller set have developed transport layers as well. As proton exchange membrane-based electrolysis shifts into higher technology readiness levels, however, there is a growing need for work optimizing materials integration, developing component-specific and device-level accelerated stress tests, and addressing manufacturing considerations. These areas directly impact electrolyzer performance, durability, and cost, and are critical to advancing hydrogen’s value and electrochemical water splitting.

08 HYDROGEN↗

Five-Year Outcomes, Cosmesis, and Toxicity With 3-Dimensional Conformal External Beam Radiation Therapy to Deliver Accelerated Partial Breast Irradiation

Purpose: To report the interim results from a study comparing the efficacy, toxicity, and cosmesis of breast-conserving treatment with accelerated partial breast irradiation (APBI) or whole breast irradiation (WBI) using 3-dimensional conformal external beam radiation therapy (3D-CRT). Methods and Materials: 102 patients with early-stage breast cancer who underwent breast-conserving surgery were randomized to receive either WBI (n=51) or APBI (n=51). In the WBI arm, 48 Gy was delivered to the whole breast in daily fractions of 2 Gy, with or without additional 10 Gy to the tumor bed. In the APBI arm, patients received 37.5 Gy in 3.75 Gy per fraction delivered twice daily. Toxicity results were scored according to the Radiation Therapy Oncology Group Common Toxicity Criteria. Skin elasticity was measured using a dedicated device (Multi-Skin-Test-Center MC-750-B2, CKelectronic-GmbH). Cosmetic results were assessed by the physician and the patients as good/excellent, regular, or poor. Results: The median follow-up time was 5 years. No local recurrences were observed. No significant differences in survival rates were found. APBI reduced acute side effects and radiation doses to healthy tissues compared with WBI (P<.01). Late skin toxicity was no worse than grade 2 in either group, without significant differences between the 2 groups. In the ipsilateral breast, the areas that received the highest doses (ie, the boost or quadrant) showed the greatest loss of elasticity. WBI resulted in a greater loss of elasticity in the high-dose area compared with APBI (P<.05). Physician assessment showed that >75% of patients in the APBI arm had excellent or good cosmesis, and these outcomes appear to be stable over time. The percentage of patients with excellent/good cosmetic results was similar in both groups. Conclusions: APBI delivered by 3D-CRT to the tumor bed for a selected group of early-stage breast cancer patients produces 5-year results similar to those achieved with conventional WBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigations on the multiple-sector hard-copper X-band accelerating structures

The development of advanced, high gradient accelerating structures is one of the leading activity of the particle accelerator community. In the technological research of new construction methods for these devices, high-power testing is a critical step for the verification of their viability. Recent experiments showed that accelerating cavities made out of hard copper, fabricated without high-temperature processes, can achieve better performance as compared with soft copper ones. Recently, we have built cavities using Tungsten Inert Gas welding and the high-power experiments confirmed that this joining process is a robust and low-cost alternative to brazing or diffusion bonding. This is a good solution for high-gradient operation, with a gradient of about 150 MV/m in X-band, at a breakdown rate of 10 -3 /pulse/meter using a shaped RF pulse with a 150 ns flat part. We continue the design, construction and high power tests of three-cells standing-wave X-band accelerating cavities fabricated with a split-open geometry, made of hard copper and vacuum-sealed by welding. Our aim is the fabrication of accelerating structures made out of hard copper alloys by using innovative cost-effective technologies. Moreover, our method of multiple-sector structures opens the way to new technological approaches and design methods, for example providing the possibility of placing dampers of the parasitic higher-order modes. Such structures with dampers allow for acceleration of multi-bunch beams, both in standing and in travelling-wave accelerating modality. Here, this paper describes the design of two cavities made of multiple sectors that were fabricated at the Italian Institute for Nuclear Physics in Frascati, Italy (INFN-LNF), assembled by means of clamping and then joined with the Tungsten Inert Gas welding in order to preserve the hardness of the metal. These are three-cell standing-wave X-band accelerating cavities, to be operated in the π-mode. We report the low-power RF tests of the first one, made of two halves, and the RF design of the second one, made of four quadrants. Both structures were built for high-gradient tests at SLAC National Accelerator Laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and application of flexible, multimodal light-emitting devices for wireless optogenetics

The rise of optogenetics provides unique opportunities to advance materials and biomedical engineering, as well as fundamental understanding in neuroscience. This protocol describes the fabrication of optoelectronic devices for studying intact neural systems. Unlike optogenetic approaches that rely on rigid fiber optics tethered to external light sources, these novel devices carry wirelessly powered microscale, inorganic light-emitting diodes (μ-ILEDs) and multimodal sensors inside the brain. Here, we describe the technical procedures for construction of these devices, their corresponding radiofrequency power scavengers and their implementation in vivo for experimental application. In total, the timeline of the procedure, including device fabrication, implantation and preparation to begin in vivo experimentation, can be completed in ~3–8 weeks. Implementation of these devices allows for chronic (tested for up to 6 months) wireless optogenetic manipulation of neural circuitry in animals navigating complex natural or home-cage environments, interacting socially, and experiencing other freely moving behaviors.

60 APPLIED LIFE SCIENCES↗

Durability Research Is Pivotal for Perovskite Photovoltaics

Metal halide perovskite solar cells have shown promising power conversion efficiencies, but commercialization requires that decent durability is also demonstrated. Under normal operation, solar cells are subject to a complex combination of stressors, such as visible light, ultraviolet light, heat, humidity, mechanical stress and electric potential, which complicates the understanding of failure mechanisms. Existing stress tests do not act as a time machine. In new materials systems such as perovskite photovoltaics, the tests have no known relationship to field service. In this Perspective we recommend following a durability learning cycle that interleaves photovoltaic module engineering with field testing; accelerated testing; and preconditioning and performance engineering. We advocate for field testing to demonstrate real-world performance and identify field-relevant failure modes, and urge the community to develop accelerated and qualification tests that account for device metastability, variations in material composition and different/various processing methods. In conclusion, these practices are more difficult, but more important, than the simple pursuit of higher initial efficiencies.

14 SOLAR ENERGY↗

Chapter 8: Time-Resolved Photoluminescence Characterization of Polycrystalline Thin-Film Solar Cells

This chapter describes some photoluminescence (PL) approaches to characterize thin film solar cells with emphasis on time-resolved methods. Spectral PL analysis is complementary and was recently reviewed. Since TRPL is not very commonly used in PV characterization, we consider interface and bulk recombination in the test structures and in devices, briefly describe charge-carrier transport and recombination microscopy, and finally, summarize and compare some CdTe, CdSeTe, CIGS, kesterite, and perovskite EO characteristics.

bulk recombination↗

Gas detectors for x-ray lasers

We have developed different types of photodetectors that are based on the photoionization of a gas at a low target density. The almost transparent devices were optimized and tested for online photon diagnostics at current and future x-ray free-electron laser facilities on a shot-to-shot basis with a temporal resolution of better than 100 ns. Characterization and calibration measurements were performed in the laboratory of the Physikalisch-Technische Bundesanstalt at the electron storage ring BESSY II in Berlin. As a result, measurement uncertainties of better than 10% for the photon-pulse energy and below 20 {mu}m for the photon-beam position were achieved at the Free-electron LASer in Hamburg (FLASH). An upgrade for the detection of hard x-rays was tested at the Sub-Picosecond Photon Source in Stanford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Test for the Existence of Mach Effects with a Rotary Device

Owing to the variation in the results of several experiments designed to produce thrust with devices employing Mach effects, it was decided to design an experiment with the simple purpose of determining whether or not Mach effects actually exist, and if they can be produced when the ''bulk'' acceleration and internal energy changes required to produce them are separately supplied. In the experiment arrays of eight 500 pf high voltage capacitors are mounted on the end of a rotor and spun to and from speeds of about 60 Hz (3600 rpm) while they are excited with a 40 KHz voltage signal with amplitudes up to 6 KV. The capacitors are sandwiched between two accelerometers and any Mach effect mass fluctuation is detected as a weight fluctuation that produces signals in the accelerometers that are antiphase. Those signals are subtracted with a differential instrumentation amplifier that suppresses other signals as common mode noise. Signals with the properties sought have been found and recorded with video equipment. They suggest that Mach effects are real, and that the bulk accelerations and internal energy changes that produce them can in fact be separately supplied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methodology for turbulence code validation: Quantification of simulation-experiment agreement and application to the TORPEX experiment

A methodology for plasma turbulence code validation is discussed, focusing on quantitative assessment of the agreement between experiments and simulations. The present work extends the analysis carried out in a previous paper [P. Ricci et al., Phys. Plasmas 16, 055703 (2009)] where the validation observables were introduced. Here, it is discussed how to quantify the agreement between experiments and simulations with respect to each observable, how to define a metric to evaluate this agreement globally, and - finally - how to assess the quality of a validation procedure. The methodology is then applied to the simulation of the basic plasma physics experiment TORPEX [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], considering both two-dimensional and three-dimensional simulation models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

1000–ton testing machine for cyclic fatigue tests of materials at liquid nitrogen temperatures

One of the main tasks of superconductive magnets R and D is to determine the mechanical and fatigue properties of structural materials and the critical design elements in the cryogenic temperature range. This paper describes a new facility built based on the industrial 1000-ton (10 MN) testing machine Schenk PC10.0S. Special equipment was developed to provide the mechanical and cyclic tensile fatigue tests of large-scale samples at the liquid nitrogen temperature and in a given load range. The main feature of the developed testing machine is the cryostat, in which the device converting a standard compression force of the testing machine to the tensile force affected at the test object is placed. The control system provides the remote control of the test and obtaining, processing and presentation of test data. As an example of the testing machine operation the test program and test results of the cyclic tensile fatigue tests of fullscale helium inlet sample of the PF1 coil ITER are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated electrostatic probe device of high resolution and accuracy

In this work, an automated apparatus for driving single electrostatic probes and acquiring the plasma-related data has been designed and fabricated. The voltage range of the present system is ±110 V with an adjustable voltage step as low as 3 mV. Voltage and current measurements are carried out with high resolution and high accuracy circuits, both based on 16 bit analog-to-digital converters. The code embedded in a micro-controller, schedules the operation of the device and transfers the experimental data to a personal computer. The modular design of the system makes possible its modification and thus increases its adaptability to different plasma setups. Finally, the reliable operation of the entire device is confirmed by tests in Electron Cyclotron Resonance plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗