Advanced Optical Diagnostics for Ice Crystal Cloud Measurements in the NASA Glenn Propulsion Systems Laboratory

A light extinction tomography technique has been developed to monitor ice water clouds upstream of a direct connected engine in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center (GRC). The system consists of 60 laser diodes with sheet generating optics and 120 detectors mounted around a 36-inch diameter ring. The sources are pulsed sequentially while the detectors acquire line-of-sight extinction data for each laser pulse. Using computed tomography algorithms, the extinction data are analyzed to produce a plot of the relative water content in the measurement plane. To target the low-spatial-frequency nature of ice water clouds, unique tomography algorithms were developed using filtered back-projection methods and direct inversion methods that use Gaussian basis functions. With the availability of a priori knowledge of the mean droplet size and the total water content at some point in the measurement plane, the tomography system can provide near real-time in-situ quantitative full-field total water content data at a measurement plane approximately 5 feet upstream of the engine inlet. Results from ice crystal clouds in the PSL are presented. In addition to the optical tomography technique, laser sheet imaging has also been applied in the PSL to provide planar ice cloud uniformity and relative water content data during facility calibration before the tomography system was available and also as validation data for the tomography system. A comparison between the laser sheet system and light extinction tomography resulting data are also presented. Very good agreement of imaged intensity and water content is demonstrated for both techniques. Also, comparative studies between the two techniques show excellent agreement in calculation of bulk total water content averaged over the center of the pipe.

Bencic, Timothy J.↗

Compact proton spectrometers for measurements of shock

The compact Wedge Range Filter (WRF) proton spectrometer was developed for OMEGA and transferred to the National Ignition Facility (NIF) as a National Ignition Campaign (NIC) diagnostic. The WRF measures the spectrum of protons from D-{sup 3}He reactions in tuning-campaign implosions containing D and {sup 3}He gas; in this work we report on the first proton spectroscopy measurement on the NIF using WRFs. The energy downshift of the 14.7-MeV proton is directly related to the total {rho}R through the plasma stopping power. Additionally, the shock proton yield is measured, which is a metric of the final merged shock strength.

42 ENGINEERING↗

Assessment and Mitigation of Diagnostic-Generated Electromagnetic Interference at the National Ignition Facility

Electromagnetic interference (EMI) is an ever-present challenge at laser facilities such as the National Ignition Facility (NIF). The major source of EMI at such facilities is laser-target interaction that can generate intense electromagnetic fields within, and outside of, the laser target chamber. In addition, the diagnostics themselves can be a source of EMI, even interfering with themselves. In this paper we describe EMI generated by ARIANE and DIXI, present measurements, and discuss effects of the diagnostic-generated EMI on ARIANE's CCD and on a PMT nearby DIXI. Finally we present some of the efforts we have made to mitigate the effects of diagnostic-generated EMI on NIF diagnostics.

42 ENGINEERING↗

WE-AB-213-05: Closing Remarks

AAPM projects and collaborations in Africa Adam Shulman (AA-SC Chair) The African Affairs Subcommittee (AA-SC) of the AAPM will present a multi-institutional approach to medical physics support in Africa. Current work to increase the quality of care and level of safety for the medical physics practice in Senegal, Ghana, and Zimbabwe will be presented, along with preliminary projects in Nigeria and Botswana. Because the task of addressing the needs of medical physics in countries across Africa is larger than one entity can accomplish on its own, the AA-SC has taken the approach of joining forces with multiple organizations such as Radiating Hope and TreatSafely (NGO’s), the IAEA, companies like BrainLab, Varian and Elekta, medical volunteers and academic institutions such as NYU and Washington University. Elements of current projects include: 1) Distance training and evaluation of the quality of contouring and treatment planning, teaching treatment planning and other subjects, and troubleshooting using modern telecommunications technology in Senegal, Ghana, and Zimbabwe; 2) Assistance in the transition from 2D to 3D in Senegal and Zimbabwe; 3) Assistance in the transition from 3D to IMRT using in-house compensators in Senegal; 4) Modernizing the cancer center in Senegal and increasing safety and; 5) Training on on 3D techniques in Ghana; 6) Assisting a teaching and training radiation oncology center to be built in Zimbabwe; 7) Working with the ISEP Program in Sub-Saharan Africa; 8) Creating instructional videos on linac commissioning; 9) Working on a possible collaboration to train physicists in Nigeria. Building on past achievements, the subcommittee seeks to make a larger impact on the continent, as the number and size of projects increases and more human resources become available. The State of Medical Physics Collaborations and Projects in Latin America Sandra Guzman (Peru) The lack of Medical Physicists (MP) in many Latin American (LA) countries leads to recruitment of professionals with incomplete education. In most LA countries only one MP responsible for each Center is currently mandated. Currently there is a large disparity among MP training programs and there is significant debate about the standards of MP graduate education in many LA countries. There are no commonly recognized academic programs, not enough clinical training sites and clinical training is not typically considered as part of the MP work. Economic pressures and high workloads also impede the creation of more training centers. The increasing need of qualified MPs require establishing a coordinated system of national Education & Training Centers (ETC), to meet the international standards of education and training in Medical Physics. This shortfall calls for support of organizations such as the IOMP, AAPM, ALFIM, IAEA, etc. Examples from various LA countries, as well as some proposed solutions, will be presented. In particular, we will discuss the resources that the AAPM and its members can offer to support regional programs. The ‘Medical Imaging’ physicist in the emerging world: Challenges and opportunities - Caridad Borrás (WGNIMP Chair) While the role of radiation therapy physicists in the emerging world is reasonably well established, the role of medical imaging physicists is not. The only perceived needs in radiology departments are equipment quality control and radiation protection, tasks that can be done by a technologist or a service engineer. To change the situation, the International Basic Safety Standard, which is adopted/adapted world-wide as national radiation protection regulations, states: “For diagnostic radiological procedures and image guided interventional procedures, the requirements of these Standards for medical imaging, calibration, dosimetry and quality assurance, including the acceptance and commissioning of medical radiological equipment, are fulfilled by or under the oversight of, or with the documented advice of a medical physicist, whose degree of involvement is determined by the complexity of the radiological procedures and the associated radiation risks”. Details on how these requirements can be carried out in resource-limited settings will be described. IAEA support to medical physics in Africa and Latin America: achievements and challenges Ahmed Meghzifene (IAEA) Shortage of clinically qualified medical physicists in radiotherapy and imaging, insufficient and inadequate education and training programs, as well as a lack of professional recognition were identified as the main issues to be addressed by the IAEA. The IAEA developed a series of integrated projects aiming specifically at promoting the essential role of medical physicists in health care, developing harmonized guidelines on dosimetry and quality assurance, and supporting education and clinical training programs. The unique feature of the IAEA approach is support it provides for implementation of guidelines and education programs in Member States through its technical cooperation project. The presentation will summarize IAEA support to Latin America and Africa in the field of medical physics and will highlight how the new International Basic Safety Standards are expected to impact the medical physics practice in low and middle income countries. Learning Objectives: Learn about the shortage of qualified Medical Physicists in Africa and Latin America. Understand the reasons of this shortage. Learn about the ways to improve the situation and AAPM role in this process.

60 APPLIED LIFE SCIENCES↗

WE-AB-213-04: IAEA Support to Medical Physics in Africa and Latin America: Achievements and Challenges

AAPM projects and collaborations in Africa Adam Shulman (AA-SC Chair) The African Affairs Subcommittee (AA-SC) of the AAPM will present a multi-institutional approach to medical physics support in Africa. Current work to increase the quality of care and level of safety for the medical physics practice in Senegal, Ghana, and Zimbabwe will be presented, along with preliminary projects in Nigeria and Botswana. Because the task of addressing the needs of medical physics in countries across Africa is larger than one entity can accomplish on its own, the AA-SC has taken the approach of joining forces with multiple organizations such as Radiating Hope and TreatSafely (NGO’s), the IAEA, companies like BrainLab, Varian and Elekta, medical volunteers and academic institutions such as NYU and Washington University. Elements of current projects include: 1) Distance training and evaluation of the quality of contouring and treatment planning, teaching treatment planning and other subjects, and troubleshooting using modern telecommunications technology in Senegal, Ghana, and Zimbabwe; 2) Assistance in the transition from 2D to 3D in Senegal and Zimbabwe; 3) Assistance in the transition from 3D to IMRT using in-house compensators in Senegal; 4) Modernizing the cancer center in Senegal and increasing safety and; 5) Training on on 3D techniques in Ghana; 6) Assisting a teaching and training radiation oncology center to be built in Zimbabwe; 7) Working with the ISEP Program in Sub-Saharan Africa; 8) Creating instructional videos on linac commissioning; 9) Working on a possible collaboration to train physicists in Nigeria. Building on past achievements, the subcommittee seeks to make a larger impact on the continent, as the number and size of projects increases and more human resources become available. The State of Medical Physics Collaborations and Projects in Latin America Sandra Guzman (Peru) The lack of Medical Physicists (MP) in many Latin American (LA) countries leads to recruitment of professionals with incomplete education. In most LA countries only one MP responsible for each Center is currently mandated. Currently there is a large disparity among MP training programs and there is significant debate about the standards of MP graduate education in many LA countries. There are no commonly recognized academic programs, not enough clinical training sites and clinical training is not typically considered as part of the MP work. Economic pressures and high workloads also impede the creation of more training centers. The increasing need of qualified MPs require establishing a coordinated system of national Education & Training Centers (ETC), to meet the international standards of education and training in Medical Physics. This shortfall calls for support of organizations such as the IOMP, AAPM, ALFIM, IAEA, etc. Examples from various LA countries, as well as some proposed solutions, will be presented. In particular, we will discuss the resources that the AAPM and its members can offer to support regional programs. The ‘Medical Imaging’ physicist in the emerging world: Challenges and opportunities - Caridad Borrás (WGNIMP Chair) While the role of radiation therapy physicists in the emerging world is reasonably well established, the role of medical imaging physicists is not. The only perceived needs in radiology departments are equipment quality control and radiation protection, tasks that can be done by a technologist or a service engineer. To change the situation, the International Basic Safety Standard, which is adopted/adapted world-wide as national radiation protection regulations, states: “For diagnostic radiological procedures and image guided interventional procedures, the requirements of these Standards for medical imaging, calibration, dosimetry and quality assurance, including the acceptance and commissioning of medical radiological equipment, are fulfilled by or under the oversight of, or with the documented advice of a medical physicist, whose degree of involvement is determined by the complexity of the radiological procedures and the associated radiation risks”. Details on how these requirements can be carried out in resource-limited settings will be described. IAEA support to medical physics in Africa and Latin America: achievements and challenges Ahmed Meghzifene (IAEA) Shortage of clinically qualified medical physicists in radiotherapy and imaging, insufficient and inadequate education and training programs, as well as a lack of professional recognition were identified as the main issues to be addressed by the IAEA. The IAEA developed a series of integrated projects aiming specifically at promoting the essential role of medical physicists in health care, developing harmonized guidelines on dosimetry and quality assurance, and supporting education and clinical training programs. The unique feature of the IAEA approach is support it provides for implementation of guidelines and education programs in Member States through its technical cooperation project. The presentation will summarize IAEA support to Latin America and Africa in the field of medical physics and will highlight how the new International Basic Safety Standards are expected to impact the medical physics practice in low and middle income countries. Learning Objectives: Learn about the shortage of qualified Medical Physicists in Africa and Latin America. Understand the reasons of this shortage. Learn about the ways to improve the situation and AAPM role in this process.

60 APPLIED LIFE SCIENCES↗

Determining appropriate data analytics for transformer health monitoring - 107

Transformers are vital assets for the safe, reliable and cost-effective operation of nuclear power plants. The unexpected failure of a transformer can lead to different consequences ranging from a lack of export capability, with the corresponding economic penalties, to catastrophic failure, with the associated health, safety and economic effects. Condition monitoring techniques examine the health of the transformer periodically, with the aim to identify early indicators of anomalies. However, many transformer failures occur because diagnostic and monitoring models do not identify degraded conditions in time. Therefore, health monitoring is an essential component to transformer life cycle management. Existing tools for transformer health monitoring use traditional dissolved gas analysis based diagnostics techniques. With the advance of prognostics and health management (PHM) applications, we can enhance traditional transformer health monitoring techniques using PHM analytics. The design of an appropriate data analytics system requires a multi-stage design process including: (i) specification of engineering requirements; (ii) characterization of existing data sources and analytics to identify complementary techniques; (iii) development of the functional specification of the analytics suite to formalize its behavior, and finally (iv) deployment, validation, and verification of the functional requirements in the final platform. Accordingly, in this paper we propose a transformer analytics suite which incorporates anomaly detection, diagnostics, and prognostics modules in order to complement existing tools for transformer health monitoring. (authors)

42 ENGINEERING↗

Containment Chamber Systems Engineering Project

Lawrence Livermore National Laboratory (LLNL) is a leading research laboratory in material properties. The most notable facility at LLNL capable of determining equation of state data for hazardous materials is the National Ignition Facility (NIF). NIF is the most energetic laser in the world and is a very versatile system that allows for a variety of laser configurations and diagnostics. The flexibility that NIF offers makes it an attractive tool for high budget programs researching specific areas of interest. Some programs require many tests to be performed, and although NIF could be an option for performing these tests, the cost and time to perform the tests would not be feasible. Also, many of these tests would underutilize the full capacity of NIF’s lasers, and NIF does not have a dedicated light source suitable for the diagnostic requirement. The needs of these tests do not align with NIF’s capabilities. The physicists are the main stakeholders for the tests, and they require a third-generation light source to meet the desired diagnostic performance. The Dynamic Compression Sector (DCS) within the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is the facility that will meet necessary laser performance and the X-ray diagnostic performance in order to obtain the desired data. DCS does not have the capability to test hazardous material, and therefore DCS requires a method and hardware for ensuring that no hazardous material is exposed before, during, or after the test. After taking a system engineering evaluation of the need for a solution to perform laser shock experiments on hazardous materials with certain laser and X-ray characteristics, a solution is proposed that meets the requirements of each involved stakeholder. The proposed solution is to contain the targets within sealed vacuum chamber that will meet the protection requirements of each facility. The chamber would be assembled and pumped down at LLNL in facilities that can handle hazardous material. Then, the chamber would be shipped under vacuum to DCS, where the chamber will be inserted into the beam paths. DCS’s laser will enter the sealed chamber and impart a shock into the target of hazardous material while the X-ray will simultaneously image the material. Once each target has been fired, the chamber will be removed from the beam path and shipped to the proper disposal facility.

42 ENGINEERING↗

A Unified Nonlinear Adaptive Approach for Detection and Isolation of Engine Faults

A challenging problem in aircraft engine health management (EHM) system development is to detect and isolate faults in system components (i.e., compressor, turbine), actuators, and sensors. Existing nonlinear EHM methods often deal with component faults, actuator faults, and sensor faults separately, which may potentially lead to incorrect diagnostic decisions and unnecessary maintenance. Therefore, it would be ideal to address sensor faults, actuator faults, and component faults under one unified framework. This paper presents a systematic and unified nonlinear adaptive framework for detecting and isolating sensor faults, actuator faults, and component faults for aircraft engines. The fault detection and isolation (FDI) architecture consists of a parallel bank of nonlinear adaptive estimators. Adaptive thresholds are appropriately designed such that, in the presence of a particular fault, all components of the residual generated by the adaptive estimator corresponding to the actual fault type remain below their thresholds. If the faults are sufficiently different, then at least one component of the residual generated by each remaining adaptive estimator should exceed its threshold. Therefore, based on the specific response of the residuals, sensor faults, actuator faults, and component faults can be isolated. The effectiveness of the approach was evaluated using the NASA C-MAPSS turbofan engine model, and simulation results are presented.

Tang, Liang↗

Experimental and computing strategies in advanced material characterization problems

The mechanical characterization of materials relies more and more often on sophisticated experimental methods that permit to acquire a large amount of data and, contemporarily, to reduce the invasiveness of the tests. This evolution accompanies the growing demand of non-destructive diagnostic tools that assess the safety level of components in use in structures and infrastructures, for instance in the strategic energy sector. Advanced material systems and properties that are not amenable to traditional techniques, for instance thin layered structures and their adhesion on the relevant substrates, can be also characterized by means of combined experimental-numerical tools elaborating data acquired by full-field measurement techniques. In this context, parameter identification procedures involve the repeated simulation of the laboratory or in situ tests by sophisticated and usually expensive non-linear analyses while, in some situation, reliable and accurate results would be required in real time. The effectiveness and the filtering capabilities of reduced models based on decomposition and interpolation techniques can be profitably used to meet these conflicting requirements. This communication intends to summarize some results recently achieved in this field by the author and her co-workers. The aim is to foster further interaction between engineering and mathematical communities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

5 kHz thermometry in a swirl-stabilized gas turbine model combustor using chirped probe pulse femtosecond CARS. Part 1: Temporally resolved swirl-flame thermometry

Single-laser-shot temperature measurements at 5 kHz were performed in a gas turbine model combustor using femtosecond (fs) coherent anti-Stokes Raman scattering (CARS). The combustor was operated at two conditions; one exhibiting a low level of thermoacoustic instability and the other a high level of instability. Measurements were performed at 73 locations within each flame in order to resolve the spatial flame structure and compare to previously published studies. The measurement procedures, including the procedure for calibrating the laser system parameters, are discussed in detail. Despite the high turbulence levels in the combustor, signals were obtained on virtually every laser shot, and these signals were strong enough for spectral fitting analysis for determination of flames temperatures. The spatial resolution of the single-laser shot temperature measurements was approximately 600 µm, the precision was approximately ±2%, and the estimated accuracy was approximately ±3%. The dynamic range was sufficient for temperature measurements ranging from 300 K to 2200 K, although some detector saturation was observed for low temperature spectra. Here these results demonstrate the usefulness of fs-CARS for the investigation of highly turbulent combustion phenomena. In a companion paper, the time-resolved fs CARS data are analyzed to provide insight into the temporal dynamics of the gas turbine model combustor flow field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase II Evaluation of Gefitinib in Patients With Newly Diagnosed Grade 4 Astrocytoma: Mayo/North Central Cancer Treatment Group Study N0074

Purpose: Amplification of the epidermal growth factor receptor (EGFR) gene represents one of the most frequent gene alterations in glioblastoma (GBM). In the current study, we evaluated gefitinib, a potent EGFR inhibitor, in the treatment of adults with newly diagnosed GBM. Methods and Materials: Ninety-eight patients (96 evaluable) were accrued between May 18, 2001, and August 2, 2002. All were newly diagnosed GBM patients who were clinically and radiographically stable/improved after radiation treatment (enrollment within 5 weeks of radiation completion). No prior chemotherapy was permitted. EGFR amplification/mutation, as assessed by fluorescence in situ hybridization and immunohistochemistry, was not required for treatment with gefitinib but was studied when tissues were available. Gefitinib was administered at 500 mg each day; for patients receiving dexamethasone or enzyme-inducing (CYP3A4) agents, dose was escalated to a maximum of 1,000 mg QD. Treatment cycles were repeated at 4-week intervals with brain magnetic resonance imaging at 8-week intervals. Results: Overall survival (OS; calculated from time of initial surgery) at 1 year (primary end point) with gefitinib was 54.2%, which was not statistically different compared with that of historical control population (48.9%, data from three previous Phase III North Central Cancer Treatment Group studies of newly diagnosed GBM patients). Progression-free survival (PFS) at 1 year post-RT (16.7%) was also not significantly different to that of historical controls (30.3%). Clinical outcome was not affected by EGFR status (amplification or vIII mutation). Fatigue (41%), rash (62%), and loose stools (58%) constituted the most frequent adverse events, the majority of these being limited to Grade 1/2. Of note, the occurrence of drug-related adverse effects, such as loose stools was associated with improved OS. Conclusions: In our evaluation of nearly 100 patients with newly diagnosed GBM, treatment with adjuvant gefitinib post-radiation was not associated with significant improvement in OS or PFS. However, patients who experienced gefitinib-associated adverse effects (rash/diarrhea) did demonstrate improved OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial transient stage of pin-to-pin nanosecond repetitively pulsed discharges in air

In this work, evolution of parameters of nanosecond repetitively pulsed (NRP) discharges in pin-to-pin configuration in air was studied during the transient stage of initial 20 discharge pulses. Gas and plasma parameters in the discharge gap were measured using coherent microwave scattering, optical emission spectroscopy, and laser Rayleigh scattering for NRP discharges at repetition frequencies of 1, 10, and 100 kHz. Memory effects (when perturbations induced by the previous discharge pulse would not decay fully until the subsequent pulse) were detected for the repetition frequencies of 10 and 100 kHz. For 10 kHz NRP discharge, the discharge parameters experienced significant change after the first pulse and continued to substantially fluctuate between subsequent pulses due to rapid evolution of gas density and temperature during the 100 μs inter-pulse time caused by intense redistribution of the flow field in the gap on that time scale. For 100 kHz NRP discharge, the discharge pulse parameters reached a new steady-state at about five pulses after initiation. Further, this new steady-state was associated with well-reproducible parameters between the discharge pulses and substantial reduction in breakdown voltage, discharge pulse energy, and electron number density in comparison to the first discharge pulse. For repetition frequencies 1–100 kHz considered in this work, the memory effects can be likely attributed to the reduction in gas number density and increase in the gas temperature that cannot fully recover to ambient conditions before subsequent discharge pulses.

42 ENGINEERING↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

Characterization of multilayer coated replicated Wolter optics for imaging x-ray emission from pulsed power

Here, we have developed a process for indirectly coating small diameter electroformed nickel replicated optics with multilayers to increase their response at high energy (i.e. >10 keV). The ability to fabricate small diameter multilayer-coated full-shell Wolter X-ray optics with narrow bandpass opens the door to several applications within astronomy and also provides a path for cross-fertilization to other fields. We report on the characterization and evaluation of the first two prototype X-ray Wolter optics to be delivered to the Z Pulsed Power Facility at Sandia National Laboratories. The intent is to develop and field several optics as part of an imaging system with targeted spectral ranges.

36 MATERIALS SCIENCE↗

Wind-tunnel investigation of the low-speed aerodynamics of slender accelerator-type configurations

The NASA-Langley 14x22-ft subsonic wind tunnel has been used to ascertain the low speed aerodynamics of a conical-forebody/annular conformal propulsion system/truncated conical afterbody hypersonic-accelerator configuration with delta-planform wing. Six-component force-and-moment data were obtained over the -4 to +30 deg alpha range and + or - 20 deg sideslip. Flow visualization diagnostics were used to characterize configuration aerodynamics. Vortex flows from the conical forebody created large values of local inflow angles at the engine inlet locations on the lee side of the model, at the moderate-alpha values associated with takeoff and landing.

Gatlin, Gregory M.↗

Non-Intrusive, Laser-Based Imaging of Jet-A Fuel Injection and Combustion Species in High Pressure, Subsonic Flows

The emphasis of combustion research efforts at NASA Glenn Research Center (GRC) is on collaborating with industry to design and test gas-turbine combustors and subcomponents for both sub- and supersonic applications. These next-generation aircraft combustors are required to meet strict international environmental restrictions limiting emissions. To meet these goals, innovative combustor concepts require operation at temperatures and pressures far exceeding those of current designs. New and innovative diagnostic tools are necessary to characterize these flow streams since existing methods are inadequate. The combustion diagnostics team at GRC has implemented a suite of highly sensitive, nonintrusive optical imaging methods to diagnose the flowfields of these new engine concepts. By using optically accessible combustors and flame-tubes, imaging of fuel and intermediate combustion species via planar laser-induced fluorescence (PLIF) at realistic pressures are now possible. Direct imaging of the fuel injection process through both planar Mie scattering and PLIF methods is also performed. Additionally, a novel combination of planar fuel fluorescence imaging and computational analysis allows a 3-D examination of the flowfield, resulting in spatially and temporally resolved fuel/air volume distribution maps. These maps provide detailed insight into the fuel injection process at actual conditions, thereby greatly enhancing the evaluation of fuel injector performance and other combustion phenomena. Stable species such as CO2, O2, N2, H2O, and hydrocarbons are also investigated by a newly demonstrated 1-D, spontaneous Raman spectroscopic method. This visible wavelength Raman technique allows the acquisition of quantitative, stable species concentration measurements from the flow.

Locke, R. J.↗

Non-Intrusive, Laser-Based Imaging of Jet-A Fuel Injection and Combustion Species in High Pressure, Subsonic Flows

The emphasis of combustion research efforts at NASA Glenn Research Center (GRC) is on collaborating with industry to design and test gas-turbine combustors and subcomponents for both sub- and supersonic applications. These next-generation aircraft combustors are required to meet strict international environmental restrictions limiting emissions. To meet these goals, innovative combustor concepts require operation at temperatures and pressures far exceeding those of cur-rent designs. New and innovative diagnostic tools are necessary to characterize these flow streams since existing methods are inadequate. The combustion diagnostics team at GRC has implemented a suite of highly sensitive, nonintrusive optical imaging methods to diagnose the flowfields of these new engine concepts. By using optically accessible combustors and flametubes, imaging of fuel and intermediate combustion species via planar laser-induced fluorescence (PLIF) at realistic pressures are now possible. Direct imaging of the fuel injection process through both planar Mie scattering and PLIF methods is also performed. Additionally, a novel combination of planar fuel fluorescence imaging and computational analysis allows a 3-D examination of the flowfield, resulting in spatially and temporally resolved fuel/air volume distribution maps. These maps provide detailed insight into the fuel injection process at actual conditions, thereby greatly enhancing the evaluation of fuel injector performance and other combustion phenomena. Stable species such as CO2, O2, N2O. and hydrocarbons are also investigated by a newly demonstrated 1-D, spontaneous Raman spectroscopic method. This visible wavelength Raman technique allows the acquisition of quantitative. stable species concentration measurements from the flow.

Locke, Randy J.↗