Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Continuous-time quantum walks on dynamic graphs

Continuous-time quantum walks (CTQWs) on static graphs provide efficient methods for search and sampling as well as a model for universal quantum computation. We consider an extension of CTQWs to the case of dynamic graphs, in which an ordered sequence of graphs governs free evolution of the quantum walk. We then consider how perfect state transfer during the quantum walk can be used to design dynamic graphs that implement a universal set of quantum logic gates. We give explicit examples for a complete logical basis, and we validate implementations using numerical simulations for quantum teleportation and addition circuits. Lastly, we discuss the potential for realizing CTQWs on dynamic graphs using actively controlled quantum optical waveguides.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Dynamics of cD clusters of galaxies. I - Redshift data for seven clusters

We present the initial results of a spectroscopic study of a sample of cD galaxy clusters. The goal of this program is to study the dynamics of the clusters, with emphasis on determining the nature and frequency of peculiar velocity cD galaxies. In this paper we present redshifts for 611 galaxies in the fields of the rich Abell clusters A193, A399, A401, A1795, A1809, A2063, and A2124. We discuss our data reduction techniques, and compare our derived velocities with previously published values. We find a frequency of emission line galaxies of about 6 percent in clusters, a factor of 2-3 less than the field.

Hill, John M.↗

High-Throughput Microfluidics Platform for Intracellular Delivery and Sampling of Biomolecules from Live Cells

Nondestructive cell membrane permeabilization systems enable the intracellular delivery of exogenous biomolecules for cell engineering tasks as well as the temporal sampling of cytosolic contents from live cells for the analysis of dynamic processes. Here, in this paper, we report a microwell array format live-cell analysis device (LCAD) that can perform localized-electroporation induced membrane permeabilization, for cellular delivery or sampling, and directly interfaces with surface-based biosensors for analyzing the extracted contents. We demonstrate the capabilities of the LCAD via an automated high-throughput workflow for multimodal analysis of live-cell dynamics, consisting of quantitative measurements of enzyme activity using self-assembled monolayers for MALDI mass spectrometry (SAMDI) and deep-learning enhanced imaging and analysis. By combining a fabrication protocol that enables robust assembly and operation of multilayer devices with embedded gold electrodes and an automated imaging workflow, we successfully deliver functional molecules (plasmid and siRNA) into live cells at multiple time-points and track their effect on gene expression and cell morphology temporally. Furthermore, we report sampling performance enhancements, achieving saturation levels of protein tyrosine phosphatase activity measured from as few as 60 cells, and demonstrate control over the amount of sampled contents by optimization of electroporation parameters using a lumped model. Lastly, we investigate the implications of cell morphology on electroporation-induced sampling of fluorescent molecules using a deep-learning enhanced image analysis workflow.

59 BASIC BIOLOGICAL SCIENCES↗

A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT

Background: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Methods: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of {sup 99m}Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Results: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). Conclusions: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A preliminary study of the variability and magnitude of the flux of biogenic sulfur gases from a New Hampshire salt marsh

Salt marshes have highly variable spatial and temporal fluxes of hydrogen sulfide, carbonyl sulfide, methane thiol, dimethyl sulfide, and carbon disulfide (H2S, COS, MeSH, DMS, and CS2, respectively). This variability was tested at nine emission sites in a New Hampshire, USA salt marsh: three replicates in each of three vegetation zones, Spartina alterniflora, S. patens, and a transition zone. Three sites were sampled simultaneously, either within or across vegetation zones, using a dynamic flux chamber technique. Difficulties with calibration and field equipment resulted in fluxes with maximum absolute uncertainties of greater than plus or minus 200 percent. However, the relative uncertainty between subsequent samples was closer to plus or minus 20 percent. Chambers are expected to affect the natural flux of gases by altering the humidity, temperature, and composition of the gas inside the chamber. Summertime fluxes are highest for all gases except COS which demonstrated evidence of a springtime peak. A summertime background flux of 5 to 100 x 10(exp -9) g S/m(sup -2) min was observed for all gases, while S alternifora fluxes of MeSH and DMS were approximately 8 fold and approximately 100 fold higher than S. patens, respectively. DMS and MeSH fluxes were higher during the day than at night. Evidence of COS uptake by plants was observed. CS2 appeared to be the quantitatively least important sulfur gas emitted. Improved laboratory and sample collection techniques and further data collection in the field will yield information on the details of salt marsh variability, will improve estimates of the error associated with single flux measurements, and will allow a more accurate estimation of sulfur fluxes from salt marshes based on vegetation and area coverage data. Inability to control the temperature and humidity inside of the chamber remain significant problems with the chamber design.

Morrison, Michael Cope↗

An Improved Genetic Algorithm approach to the Unit Commitment/Economic Dispatch problem

The deployment of new technologies, the importance of accurately modeling the dynamics of the generating units and the introduction of new policies are making the solution of the Unit Commitment/Economic Dispatch problem more and more complicated.In the present scenario, traditionally followed scheduling criteria might not lead to the optimal fleet configuration any more. In addition, most of the widely used techniques have limited capabilities at modeling the nonlinear dynamics of committed power plants. When realistic power systems comprising of several tens of generating units are modeled, the resulting optimization problem turns to be computationally intensive for the current computing capabilities. In this paper, an improved version of a GA-based optimization algorithm is presented. A detailed methodology aimed at obtaining a more efficient version of the GA, and a more detailed and accurate description of the flexible operation flexibility of the power plants is described.

genetic algorithm↗

Characterizing laser-heated polymer foams with simultaneous x-ray fluorescence spectroscopy and Thomson scattering at the Matter in Extreme Conditions Endstation at LCLS

Understanding the behavior of polymer foams at high energy density conditions is crucial to advance inertial fusion energy research. Here, we present a new experimental platform designed to measure the thermodynamic state of these materials at megabar pressures. At the Matter in Extreme Conditions Endstation of the Linac Coherent Light Source, we heat samples using an optical, high-intensity, femtosecond laser and dynamically probe them with ultra-short, coherent x-ray pulses of high peak brightness. We perform x-ray Thomson scattering measurements in forward and backward scattering geometries to capture both collective and non-collective electron behavior in the sample. Simultaneously, x-ray fluorescence spectroscopy is used to measure the emission from a mid-Z dopant, providing complementary information on the plasma conditions. By combining these techniques, we obtain temporally resolved temperature measurements of the transient warm dense matter states. Our initial experiments designed to benchmark the platform with carbon samples yielded data resolving the ultrafast response to laser heating with sub-picosecond resolution, measuring plasma temperatures exceeding 50 eV. These findings lay the foundation for precision studies of the dynamic evolution of laser-heated polymer foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Importance Sampling Model-Based Diffusion for Trajectory Optimization

Trajectory optimization for robotic systems remains a challenging problem. This is especially true for robotic systems featuring nonlinear dynamics and many degrees of freedom. Data-based or model-free diffusion has recently been popularized in the fields of artificial intelligence and trajectory optimization. Model-Based Diffusion provides a data-free method of trajectory optimization, trained at runtime on a system dynamics model, suitable for high-dimensional models. This paper examines how importance sampling can enhance the performance of Model-Based Diffusion for trajectory optimization. Here, we quantify the benefits of importance sampling across three long horizon planning tasks. These results show as much as a 13x improvement in sample efficiency depending on environment and optimization parameters.

Golembeski, Seth [Georgia Institute of Technology,↗

Stacking caustic masses from galaxy clusters

Ongoing and future spectroscopic surveys will measure numerous galaxy redshifts within tens of thousands of galaxy clusters. However, the sampling within these clusters will be low, 15 1000 galaxies per ensemble phase space, the escape-velocity edge becomes readily identifiable and the presence of interloping galaxies is minimized. We develop and test an algorithm to trace the projected phase-space surface directly, which results in minimally biased dynamical mass estimates. We then quantify how binning and sampling affect the phase-space-based mass estimates when using an observational proxy that incorporates realistic mass scatter, like richness, and find the added uncertainty in the binning procedure has minimal influence on the resulting bias and scatter of the stacked mass estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitive Measures of Soil Health Reveal Carbon Stability Across a Management Intensity and Plant Biodiversity Gradient

Soil carbon (C) is a major driver of soil health, yet little is known regarding how sensitive measures of soil C shift temporally within a single growing season in response to short-term weather perturbations. Our study aimed to i) Examine how long-term management impacts soil C cycling and stability across a management intensity and plant biodiversity gradient and ii) Assess how sensitive soil health indicators change temporally over the course of a single growing season in response to recent weather patterns. Here we quantify a variety of sensitive soil C measures at four time points across the 2021 growing season at the W.K. Kellogg Biological Station’s Long Term Ecological Research Trial (LTER) located in southwest Michigan, USA. The eight systems sampled included four annual soybean ( Glycine max ) systems that ranged in management intensity (conventional, no-till, reduced input, and biologically-based), two perennial biofuel cropping systems (switchgrass ( Panicum virgatum) and hybrid poplars ( Populus nigra x P.maximowiczii )), and two unmanaged systems (early successional system and a mown but never tilled grassland). We found that unmanaged systems with increased perenniality enhanced mineralizable C (Min C) and permanganate oxidizable C (POXC) values. Additionally, all soil health indicators were found to be sensitive to changes in short-term weather perturbations over the course of the growing season. The implications of this study are threefold. First, this study assess indicators of labile and stable C pools over the course of the growing season and reflects the stability of soil C in different systems. Second, POXC, Min C, and ß-glucosidase (GLU) activity are sensitive soil health indicators that fluctuate temporally, which means that these soil health indicators could help elucidate the impact that weather patterns have on soil C dynamics. Lastly, for effective monitoring of soil C, sampling time and frequency should be considered for a comprehensive understanding of soil C cycling within a system.

Martin, Tvisha↗

Dynamical shift of NMR lines in nanostructured Ga–In–Sn melt

NMR spectrum and recovery of longitudinal nuclear magnetization after inverting pulses were measured for isotopes {sup 69}Ga and {sup 71}Ga in a liquid eutectic alloy Ga–In–Sn introduced in porous glasses having pores with the sizes of 25 and 7 nm. The measurements were conducted in the fields of 9.4, 11.7, and 17.6 T and compared with those for the bulk melt sample. Differences between the shape and position of the NMR lines in various fields and for different gallium isotopes were revealed in the melt introduced into the porous glass with the pores size of 7 nm. Data obtained for this sample were interpreted based on the theoretical model of dynamic quadrupolar shift, and correlation time of atomic motion was found within this model. Characteristics of the atomic motion calculated based on the dynamic shift model and from the spin relaxation data were shown to agree with each other.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamic light scattering homodyne probe

An optical probe for analyzing a sample illuminated by a laser includes an input optical fiber operably connectable to the laser where the input optical fiber has an entrance end and an exit end. The probe also includes a first beam splitter where the first beam splitter is adapted to transmit an alignment portion of a light beam from the input fiber exit end and to reflect a homodyning portion of the light beam from the input fiber. The probe also includes a lens between the input fiber exit end and the first beam splitter and a first and a second output optical fiber, each having an entrance end and an exit end, each exit end being operably connectable to respective optical detectors. The probe also includes a second beam splitter which is adapted to reflect at least a portion of the reflected homodyning portion into the output fiber entrance ends and to transmit light from the laser scattered by the sample into the entrance ends.

Meyer, William V.↗

Internal mixing dynamics of Cu/Sn-Pb plasmas produced by femtosecond laser ablation

Chemical imaging applications using Laser Induced Breakdown Spectroscopy (LIBS) involve laser ablation sampling at interfaces or boundaries between materials with different thermophysical and optical properties, leading to the formation of two initially isolated plasmas. The mechanisms of mixing in these plasmas and their direct implications on spectral emission and chemical imaging remain largely unknown. We investigate the mixing dynamics of isolated plasmas produced using femtosecond (fs) laser pulses at the interface between two different model Cu and Sn–Pb samples. Specifically, we study the spatial and temporal mixing dynamics and outer plasma expansion dynamics of the fs plasma components. The time-resolved degree of component mixing, horizontal and vertical expansion, mixing speed, and temperature and electron density of the heterogeneous plasma are characterized. Mixing processes are initiated early on, <100 ns after the laser pulse, and continue taking place until the end of plasma emission persistence at a constant velocity of 10 4 cm/s. In conclusion, these findings demonstrate that proper selection of detection timing parameters and signal collection position are critically important in precise LIBS measurements to ensure that full plasma mixing has taken place and that homogeneous spectral emission is properly detected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aerothermal Ground Testing of Flexible Thermal Protection Systems for Hypersonic Inflatable Aerodynamic Decelerators

Flexible TPS development involves ground testing and analysis necessary to characterize performance of the FTPS candidates prior to flight testing. This paper provides an overview of the analysis and ground testing efforts performed over the last year at the NASA Langley Research Center and in the Boeing Large-Core Arc Tunnel (LCAT). In the LCAT test series, material layups were subjected to aerothermal loads commensurate with peak re-entry conditions enveloping a range of HIAD mission trajectories. The FTPS layups were tested over a heat flux range from 20 to 50 W/cm with associated surface pressures of 3 to 8 kPa. To support the testing effort a significant redesign of the existing shear (wedge) model holder from previous testing efforts was undertaken to develop a new test technique for supporting and evaluating the FTPS in the high-temperature, arc jet flow. Since the FTPS test samples typically experience a geometry change during testing, computational fluid dynamic (CFD) models of the arc jet flow field and test model were developed to support the testing effort. The CFD results were used to help determine the test conditions experienced by the test samples as the surface geometry changes. This paper includes an overview of the Boeing LCAT facility, the general approach for testing FTPS, CFD analysis methodology and results, model holder design and test methodology, and selected thermal results of several FTPS layups.

Bruce, Walter E., III↗

Understanding collective human movement dynamics during large-scale events using big geosocial data analytics

Conventional approaches for modeling human mobility pattern often focus on human activity and movement dynamics in their regular daily lives and cannot capture changes in human movement dynamics in response to large-scale events. With the rapid advancement of information and communication technologies, many researchers have adopted alternative data sources (e.g., cell phone records, GPS trajectory data) from private data vendors to study human movement dynamics in response to large-scale natural or societal events. Big geosocial data such as georeferenced tweets are publicly available and dynamically evolving as real-world events are happening, making it more likely to capture the real-time sentiments and responses of populations. However, precisely-geolocated geosocial data is scarce and biased toward urban population centers. In this research, we developed a big geosocial data analytical framework for extracting human movement dynamics in response to large-scale events from publicly available georeferenced tweets. The framework includes a two-stage data collection module that collects data in a more targeted fashion in order to mitigate the data scarcity issue of georeferenced tweets; in addition, a variable bandwidth kernel density estimation(VB-KDE) approach was adopted to fuse georeference information at different spatial scales, further augmenting the signals of human movement dynamics contained in georeferenced tweets. To correct for the sampling bias of georeferenced tweets, we adjusted the number of tweets for different spatial units (e.g., county, state) by population. To demonstrate the performance of the proposed analytic framework, we chose an astronomical event that occurred nationwide across the United States, i.e., the 2017 Great American Eclipse, as an example event and studied the human movement dynamics in response to this event. Finally, this analytic framework can easily be applied to other types of large-scale events such as hurricanes or earthquakes.

54 ENVIRONMENTAL SCIENCES↗

The MASSIVE Survey. XVI. The Stellar Initial Mass Function in the Center of MASSIVE Early-type Galaxies

The stellar initial mass function (IMF) is a fundamental property in the measurement of stellar masses and galaxy star formation histories. In this work, we focus on the most massive galaxies in the nearby universe $\mathrm{log}({M}_{\star }/\,{M}_{\odot })\gt 11.2$. We obtain high-quality Magellan/LDSS-3 long-slit spectroscopy with a wide wavelength coverage of 0.4–1.01 μm for 41 early-type galaxies (ETGs) in the MASSIVE survey and derive high signal-to-noise spectra within an aperture of R e /8. Using detailed stellar synthesis models, we constrain the elemental abundances and stellar IMF of each galaxy through full spectral modeling. All the ETGs in our sample have an IMF that is steeper than a Milky Way (Kroupa) IMF. The best-fit IMF mismatch parameter, α IMF = (M/L)/(M/L) MW , ranges from 1.1 to 3.1, with an average of $\langle$α IMF $\rangle$ = 1.84, suggesting that on average, the IMF is more bottom heavy than Salpeter. Comparing the estimated stellar masses with the dynamical masses, we find that most galaxies have stellar masses that are smaller than their dynamical masses within the 1σ uncertainty. We complement our sample with lower-mass galaxies from the literature and confirm that $\mathrm{log}({\alpha }_{\mathrm{IMF}})$ is positively correlated with $\mathrm{log}(\sigma )$, $\mathrm{log}({M}_{\star })$, and $\mathrm{log}({M}_{\mathrm{dyn}})$. From the combined sample, we show that the IMF in the centers of more massive ETGs is more bottom heavy. In addition, we find that $\mathrm{log}({\alpha }_{\mathrm{IMF}})$ is positively correlated with both [Mg/Fe] and the estimated total metallicity [Z/H]. We find suggestive evidence that the effective stellar surface density Σ Kroupa might be responsible for the variation of α IMF . We conclude that σ, [Mg/Fe], and [Z/H] are the primary drivers of the global stellar IMF variation.

79 ASTRONOMY AND ASTROPHYSICS↗

Longitudinal Analysis of SARS-CoV-2 Vaccine Breakthrough Infections Reveals Limited Infectious Virus Shedding and Restricted Tissue Distribution

Background. The global effort to vaccinate people against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during an ongoing pandemic has raised questions about how vaccine breakthrough infections compare with infections in immunologically naive individuals and the potential for vaccinated individuals to transmit the virus. Methods. We examined viral dynamics and infectious virus shedding through daily longitudinal sampling in 23 adults infected with SARS-CoV-2 at varying stages of vaccination, including 6 fully vaccinated individuals. Results. The durations of both infectious virus shedding and symptoms were significantly reduced in vaccinated individuals compared with unvaccinated individuals. We also observed that breakthrough infections are associated with strong tissue compartmentalization and are only detectable in saliva in some cases. Conclusions. Vaccination shortens the duration of time of high transmission potential, minimizes symptom duration, and may restrict tissue dissemination.

59 BASIC BIOLOGICAL SCIENCES↗