Search NASA⌕ Search

SEARCH · Search NASA

Results for “embedded methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Replacing non-biomedical concepts improves embedding of biomedical concepts

Embeddings are semantically meaningful representations of words in a vector space, commonly used to enhance downstream machine learning applications. Traditional biomedical embedding techniques often replace all synonymous words representing biological or medical concepts with a unique token, ensuring consistent representation and improving embedding quality. However, the potential impact of replacing non-biomedical concept synonyms has received less attention. Embedding approaches often employ concept replacement to replace concepts that span multiple words, such as non-small-cell lung carcinoma, with a single concept identifier (e.g., D002289). Also, all synonyms of each concept are merged into the same identifier. Here, we additionally leveraged WordNet to identify and replace sets of non-biomedical synonyms with their most common representatives. This combined approach aimed to reduce embedding noise from non-biomedical terms while preserving the integrity of biomedical concept representations. We applied this method to 1,055 biomedical concept sets representing molecular signatures or medical categories and assessed the mean pairwise distance of embeddings with and without non-biomedical synonym replacement. A smaller mean pairwise distance was interpreted as greater intra-cluster coherence and higher embedding quality. Embeddings were generated using the Word2Vec algorithm applied to a corpus of 10 million PubMed abstracts. Our results demonstrate that the addition of non-biomedical synonym replacement reduced the mean intra-cluster distance by an average of 8%, suggesting that this complementary approach enhances embedding quality. Future work will assess its applicability to other embedding techniques and downstream tasks. Python code implementing this method is provided under an open-source license.

algorithms↗

Development of an Experimental Approach to Achieve Spatially Resolved Plant Root-Associated Metaproteomics Using an Agar-Plate System

Plant–microbe interactions in the rhizosphere play a vital role in plant health and productivity. The composition and function of root-associated microbiomes is strongly influenced by their surrounding environment, which is often customized by their host. How microbiomes change with respect to space and time across plant roots remains poorly understood, and methodologies that facilitate spatiotemporal metaproteomic studies of root-associated microbiomes are yet to be realized. Here, we developed a method that provides spatially resolved metaproteome measurements along plant roots embedded in agar-plate culture systems, which have long been used to study plants. Spatially defined agar “plugs” of interest were excised and subsequently processed using a novel peptide extraction method prior to metaproteomics, which was used to infer both microbial community composition and function. As a proof-of-principle, a previously studied 10-member community constructed from a Populus root system was grown in an agar plate with a 3-week-old Populus trichocarpa plant. Metaproteomics was performed across two time points (24 and 48 h) for three distinct locations (root base, root tip, and a region distant from the root). The spatial resolution of these measurements provides evidence that microbiome composition and expression changes across the plant root interface. Interrogation of the individual microbial proteomes revealed functional profiles related to their behavioral associations with the plant root, in which chemotaxis and augmented metabolism likely supported predominance of the most abundant member. This study demonstrated a novel peptide extraction method for studying plant agar-plate culture systems, which was previously unsuitable for (meta)proteomic measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation

Purpose: The aim of this study was to develop novel methods for photoacoustically determining the optical absorption coefficient of biological tissues using Monte Carlo (MC) simulation. Methods: In this study, the authors propose two quantitative photoacoustic tomography (PAT) methods for mapping the optical absorption coefficient. The reconstruction methods combine conventional PAT with MC simulation in a novel way to determine the optical absorption coefficient of biological tissues or organs. Specifically, the authors’ two schemes were theoretically and experimentally examined using simulations, tissue-mimicking phantoms, ex vivo, and in vivo tests. In particular, the authors explored these methods using several objects with different absorption contrasts embedded in turbid media and by using high-absorption media when the diffusion approximation was not effective at describing the photon transport. Results: The simulations and experimental tests showed that the reconstructions were quantitatively accurate in terms of the locations, sizes, and optical properties of the targets. The positions of the recovered targets were accessed by the property profiles, where the authors discovered that the off center error was less than 0.1 mm for the circular target. Meanwhile, the sizes and quantitative optical properties of the targets were quantified by estimating the full width half maximum of the optical absorption property. Interestingly, for the reconstructed sizes, the authors discovered that the errors ranged from 0 for relatively small-size targets to 26% for relatively large-size targets whereas for the recovered optical properties, the errors ranged from 0% to 12.5% for different cases. Conclusions: The authors found that their methods can quantitatively reconstruct absorbing objects of different sizes and optical contrasts even when the diffusion approximation is unable to accurately describe the photon propagation in biological tissues. In particular, their methods are able to resolve the intrinsic difficulties that occur when quantitative PAT is conducted by combining conventional PAT with the diffusion approximation or with radiation transport modeling.

60 APPLIED LIFE SCIENCES↗

Overview of Methods for Deriving the Radiative Transfer Theory from the Maxwell Equations. I: Approach Based on the Far-Field Foldy Equations

In this paper, we revisit, with further enhancements and clarifications, the self-consistent first-principles approach developed previously for deriving the vector radiative transfer theory for a discrete random medium with a sparse concentration of particles. We specifically consider the case of a plane-parallel particulate layer embedded in an otherwise homogeneous unbounded medium. The solution method is based on the far-field Foldy equations, an order-of-scattering expansion for the total field derived under the Twersky approximation, the computation of the coherent field by assuming that the positions of the particles are uncorrelated, and the ladder approximation for the coherency dyadic. The latter yields an integral equation for the diffuse specific coherency dyadic, defined through an angular spectrum repre- sentation for the coherency dyadic, which in turn, gives the vector radiative transfer equation for the diffuse specific intensity column vector. We analyze specifically the computation of the coherent field for inhomogeneous particulate media and multiple species of particles, the continuous extension of the far-field representation to the near field, the Foldy approximation, and the Foldy integral equation for the coherent field. Finally, we discuss the transition from the vector to the scalar radiative transfer equation.

Doicu, Adrian↗

Integrating Symbolic and Statistical Methods for Testing Intelligent Systems Applications to Machine Learning and Computer Vision

Embedded intelligent systems ranging from tiny im- plantable biomedical devices to large swarms of autonomous un- manned aerial systems are becoming pervasive in our daily lives. While we depend on the flawless functioning of such intelligent systems, and often take their behavioral correctness and safety for granted, it is notoriously difficult to generate test cases that expose subtle errors in the implementations of machine learning algorithms. Hence, the validation of intelligent systems is usually achieved by studying their behavior on representative data sets, using methods such as cross-validation and bootstrapping.In this paper, we present a new testing methodology for studying the correctness of intelligent systems. Our approach uses symbolic decision procedures coupled with statistical hypothesis testing to. We also use our algorithm to analyze the robustness of a human detection algorithm built using the OpenCV open-source computer vision library. We show that the human detection implementation can fail to detect humans in perturbed video frames even when the perturbations are so small that the corresponding frames look identical to the naked eye.

Jha, Sumit Kumar↗

Human Papillomavirus (HPV) Infection in Squamous Cell Carcinomas Arising From the Oropharynx: Detection of HPV DNA and p16 Immunohistochemistry as Diagnostic and Prognostic Indicators—A Pilot Study

Purpose: Human papillomavirus (HPV) 16 infection is associated with oropharyngeal carcinogenesis and is likely the cause of the reported increase in disease incidence. We evaluated the prevalence of HPV infection and the reliability of different diagnostic tools using primary tumor samples from a cohort of 50 patients. Methods and Materials: Formalin-fixed paraffin-embedded (FFPE) tumor samples were collected from all 50 consecutive primary oropharyngeal SCC patients who were enrolled in the study; fresh tumor samples were available in 22 cases. NucliSENS EasyQ HPVv1 was used for RNA, and Digene Hybrid Capture-2(HC2) was used for DNA detection. p16 Expression was evaluated by immunohistochemistry in FPPE specimens. Results: Based on the DNA detection assay on FFPE samples, the frequency of high-risk HPV infection was 32%. The agreement rate between HPV RNA and HPV DNA detection in fresh samples was 100%. The agreement rate between p16 immunohistochemistry (IHC) and the detection of HPV DNA in the FFPE samples was fair but not excellent (κ = 0.618). HPV DNA detection was highly significant, as measured by disease-specific survival and determined using a Wilcoxon test (P=.001). p16 IHC also exhibited a prognostic value but with a lower statistical significance (P=.0475). The detection of HPV DNA, but not p16 IHC, was also significantly correlated with locoregional control (P=.0461). Conclusion: Diagnostic methods based on the detection of HPV nucleic acids appear to be more reliable and objective because they do not require reading by a trained histopathologist. Furthermore, the detection of HPV DNA exhibits an improved correlation with survival, and therefore appears definitely more reliable than p16 IHC for routine use in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Higher order methods for convection-diffusion problems

This paper applies C1 cubic Hermite polynomials embedded in an orthogonal collocation scheme to the spatial discretization of the unsteady nonlinear Burgers equation as a model of the equations of fluid mechanics. The temporal discretization is carried out by means of either a noniterative finite difference or an iterative finite difference procedure. Results of this method are compared with those of a second-order finite difference scheme and a splined-cubic Taylor's series scheme. Stability limits are derived and the matrix structure of the several schemes are compared.

Murphy, J. D.↗

A dual-stage method for lesion segmentation on digital mammograms

Mass lesion segmentation on mammograms is a challenging task since mass lesions are usually embedded and hidden in varying densities of parenchymal tissue structures. In this article, we present a method for automatic delineation of lesion boundaries on digital mammograms. This method utilizes a geometric active contour model that minimizes an energy function based on the homogeneities inside and outside of the evolving contour. Prior to the application of the active contour model, a radial gradient index (RGI)-based segmentation method is applied to yield an initial contour closer to the lesion boundary location in a computationally efficient manner. Based on the initial segmentation, an automatic background estimation method is applied to identify the effective circumstance of the lesion, and a dynamic stopping criterion is implemented to terminate the contour evolution when it reaches the lesion boundary. By using a full-field digital mammography database with 739 images, we quantitatively compare the proposed algorithm with a conventional region-growing method and an RGI-based algorithm by use of the area overlap ratio between computer segmentation and manual segmentation by an expert radiologist. At an overlap threshold of 0.4, 85% of the images are correctly segmented with the proposed method, while only 69% and 73% of the images are correctly delineated by our previous developed region-growing and RGI methods, respectively. This resulting improvement in segmentation is statistically significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deadlock-free class routes for collective communications embedded in a multi-dimensional torus network

A computer implemented method and a system for routing data packets in a multi-dimensional computer network. The method comprises routing a data packet among nodes along one dimension towards a root node, each node having input and output communication links, said root node not having any outgoing uplinks, and determining at each node if the data packet has reached a predefined coordinate for the dimension or an edge of the subrectangle for the dimension, and if the data packet has reached the predefined coordinate for the dimension or the edge of the subrectangle for the dimension, determining if the data packet has reached the root node, and if the data packet has not reached the root node, routing the data packet among nodes along another dimension towards the root node.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power allocation by load aggregator with heterogeneous loads using weighted projection

With the recently increasing adoption of transactive energy markets, the role of a load aggregator is becoming increasingly important. Among the many tasks of an aggregator, the task of managing the electricity consumption among a group of grid-interactive efficient buildings according to the demand on the grid is taken up. Specifically, here, the task of allocating a certain amount of power among the participating customers while respecting their preferences and comfort is considered. Modeling this as an aggregate flexibility, the virtual battery conditions that are employed to verify the feasibility of a candidate power profile are derived. A feasible power profile, when allocated, satisfies specified comfort bands. To determine the ideal power requirement of the loads, the model-free control method is employed. The feasible power profile is allocated by embedding the customers’ preferences through weights, posing the power constraint as a hyperplane, and employing a weighted projection from the ideal power requirements onto the constraint plane to solve the considered task. The proposed method is computationally efficient and scalable to any number of heterogeneous thermostatically controlled loads in buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-F-T-340: Direct Editing of Dose Volume Histograms: Algorithms and a Unified Convex Formulation for Treatment Planning with Dose Constraints

Purpose: To develop a procedure for including dose constraints in convex programming-based approaches to treatment planning, and to support dynamic modification of such constraints during planning. Methods: We present a mathematical approach that allows mean dose, maximum dose, minimum dose and dose volume (i.e., percentile) constraints to be appended to any convex formulation of an inverse planning problem. The first three constraint types are convex and readily incorporated. Dose volume constraints are not convex, however, so we introduce a convex restriction that is related to CVaR-based approaches previously proposed in the literature. To compensate for the conservatism of this restriction, we propose a new two-pass algorithm that solves the restricted problem on a first pass and uses this solution to form exact constraints on a second pass. In another variant, we introduce slack variables for each dose constraint to prevent the problem from becoming infeasible when the user specifies an incompatible set of constraints. We implement the proposed methods in Python using the convex programming package cvxpy in conjunction with the open source convex solvers SCS and ECOS. Results: We show, for several cases taken from the clinic, that our proposed method meets specified constraints (often with margin) when they are feasible. Constraints are met exactly when we use the two-pass method, and infeasible constraints are replaced with the nearest feasible constraint when slacks are used. Finally, we introduce ConRad, a Python-embedded free software package for convex radiation therapy planning. ConRad implements the methods described above and offers a simple interface for specifying prescriptions and dose constraints. Conclusion: This work demonstrates the feasibility of using modifiable dose constraints in a convex formulation, making it practical to guide the treatment planning process with interactively specified dose constraints. This work was supported by the Stanford BioX Graduate Fellowship and NIH Grant 5R01CA176553.

60 APPLIED LIFE SCIENCES↗

Direct Ink-Write Printing of Ceramic Clay with an Embedded Wireless Temperature and Relative Humidity Sensor

This research presents a simple method to additively manufacture Cone 5 porcelain clay ceramics by using the direct ink-write (DIW) printing technique. DIW has allowed the application of extruding highly viscous ceramic materials with relatively high-quality and good mechanical properties, which additionally allows a freedom of design and the capability of manufacturing complex geometrical shapes. Clay particles were mixed with deionized (DI) water at different ratios, where the most suitable composition for 3D printing was observed at a 1:5 w/c ratio (16.2 wt.%. of DI water). Differential geometrical designs were printed to demonstrate the printing capabilities of the paste. In addition, a clay structure was fabricated with an embedded wireless temperature and relative humidity (RH) sensor during the 3D printing process. The embedded sensor read up to 65% RH and temperatures of up to 85 °F from a maximum distance of 141.7 m. The structural integrity of the selected 3D printed geometries was confirmed through the compressive strength of fired and non-fired clay samples, with strengths of 70 MPa and 90 MPa, respectively. This research demonstrates the feasibility of using the DIW printing of porcelain clay with embedded sensors, with fully functional temperature- and humidity-sensing capabilities.

42 ENGINEERING↗

Projector‐Based Quantum Embedding Study of Iron Complexes

Projection‐based embedding theory (PBET) is used to calculate and assess the challenging spin‐crossover energies for a selection of small Fe‐containing systems by embedding the metal center into the frozen potential of the ligands. MP2, CCSD, and CCSD(T) are embedded in potentials from the SCAN and r 2 SCAN functionals and compared with the canonical values for the constituent methods and previously reported reference values. Considering the PBET calculations as a correction for the underlying DFT, the embedding calculations are able to provided improvement for most cases. In some cases, the PBET methods are able to compensate for limitations in the wave function methods and produce results similar to more rigorous calculations from the literature. For the systems with spin‐crossover energies near zero, the current methodology fails to provide consistent improvement. In conclusion, the isolated recalculation of the electronic structure around the metal center when embedded into a DFT treatment of the ligand field shows promise as a pragmatic and lower cost treatment compared to the canonical treatment of the whole system of the difficult class of spin‐crossover complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale Kondo Physics and Nanomechanics of Metallic Systems from First Principles

Kohn-Sham density functional theory (DFT) is a powerful, well-established tool for the study of condensed phase electronic structure. However, there are still a number of situations where its applicability is limited. The basic theme of our research is the development of first principles electronic structure approaches for condensed matter that goes beyond what can currently be done with standard implementations of Kohn-Sham DFT. Our efforts to this end have focused on two classes of methods. The first addresses the well-known inability of DFT to handle strong, many-body electron correlation effects. Our approach is a DFT-based embedding theory, to treat localized features (e.g. impurity, adsorbate, vacancy, etc.) embedded in a periodic, metallic crystal. A description for the embedded region is provided by explicitly correlated, ab initio wave function methods. DFT, as a formally ground state theory, does not give a good description of excited states; an additional feature of our approach is the ability to obtain excitations localized in this region. We apply our method to a first-principles study of the adsorption of a single magnetic Co adatom on non-magnetic Cu(111), a known Kondo system whose behavior is governed by strong electron correlation. The second class of methods that we are developing is an orbital-free density functional theory (OFDFT), which addresses the speed limitations of Kohn-Sham DFT. OFDFT is a powerful, 0(A) scaling method for electronic structure calculations. Unlike Kohn-Sham DFT, OFDFT goes back to the original Hohenberg-Kohn idea of directly optimizing an energy functional which is an explicit functional of the density, without invoking an orbital description. This eliminates the need to manipulate orbitals, which leads to O(N 3 ) scaling in the Kohn-Sham approach. The speed of OFDFT allows direct electronic structure calculations on large systems on the order of thousands to tens of thousands of atoms, an expensive feat within Kohn-Sham. Due to our incomplete knowledge of the exact, universal energy density functional, this speedup comes at the cost of some accuracy with respect to Kohn-Sham methods. However, OFDFT has been shown to be remarkably accurate with respect to Kohn-Sham when used in the study of nearly-free-electron-like metals, e.g., Al, for which good density functionals have been derived. Examples of past applications of OFDFT include the prediction of properties of bulk crystals, surfaces, vacancies, vacancy clusters, nanoclusters, and dislocations, as well as OFDFT-based multiscale simulations of nanoindentation in Al and Al-Mg alloys.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalized Lions-Peetre interpolation construction and optimal embedding theorems for Sobolev spaces

In the paper, a new description of the generalized Lions-Peetre method of means is found, which enables one to evaluate the interpolation orbits of spaces constructed by this method. The list of these spaces includes all Lorentz spaces with functional parameters, Orlicz spaces, and spaces close to them. This leads in turn to new optimal embedding theorems for Sobolev spaces produced using the Lions-Peetre construction in rearrangement invariant spaces. It turns out that the optimal space of the embedding is also a generalized Lions-Peetre space whose parameters are explicitly evaluated. Bibliography: 18 titles.

97 MATHEMATICS AND COMPUTING↗

Function Preserving Projection

With function preserving projection (FPP), we aim to address high-dimensional data exploration challenges common in many scientific applications. Instead of preserving the global or local geometric structure of a dataset like traditional dimensionality reduction methods (e.g., principal component analysis, t-stochastic neighborhood embedding), the proposed approach finds a linear projection that reveal interpretable (yet potentially nonlinear) pattern of the properties of interests defined on a highdimensional domain (e.g., simulation yield defined on the input parameter space). The key insight driving FPP is the fact that while non-linear embeddings are difficult to interpret, humans are highly skilled in understanding complex visual patterns. FPP lets users select the complexity of a pattern they consider interpretable, allows to find a joint projection that explains multiple functions, and provides a confidence statistic (akin to a p-value) indicating how salient the resulting pattern is. We demonstrate the efficacy of the proposed method on several synthetic and scientific datasets for both continuous (regression) and discrete (classification) problems of interests and illustrate the scalability of FPP by finding an optimal projection for close to 40 gigabytes in around 10 minutes.

Liu, SHUSEN↗

SU-G-TeP2-05: Development of a Thimble Calorimeter for Absorbed Dose to Water Characterized in MV Photons

Purpose: To develop a thimble sized polystyrene calorimeter for use from kV to MV photons, as a primary reference standard for applications from diagnostic CT imaging to therapy beam dose determination. Methods: A polystyrene calorimeter about 1.5 cm diameter embedded with small thermistors was characterized in a 6 MV photon beam from a clinical accelerator at 5 nominal dose rates from 0.8 to 4 Gy/min. Irradiations were delivered with beam on/off cycles first at 60 s and then at 20 s. Two sets of phantom conditions were evaluated: 1) in a 30 cm diameter polyethylene cylinder, and 2) in 10 cm depth of a 30 cm water phantom. The temperature waveforms were recorded and analyzed for temperature rise, arriving at a dose to polystyrene. This value is compared with the result of measurements under identical conditions using an ionization chamber calibrated for absorbed dose to water. Monte Carlo simulations were performed on the measurement systems to estimate such a ratio. Results: The ratio of the dose determined by the calorimeter to the dose reported by the ionization chamber was aggregated from all 5 dose rates. The 60 s results show a much elevated response in both phantoms compared to their respective expected results based on simulation. This deviation was reduced when the on/off cycles were shortened to 20 s. This behavior was possibly due to the heat conduction effects in the small calorimeter body. Finite element modeling is being conducted to simulate this effect. Conclusion: A small solid plastic calorimeter offers the convenience of a portable absorbed dose standard based on direct measurement of energy deposition, but comes at the expense of heat transfer complications which need to be characterized. This work offers preliminary evidence of the behavior and quantitative assessment of the issues to be resolved in future investigations.

60 APPLIED LIFE SCIENCES↗