Search NASA⌕ Search

SEARCH · Search NASA

Results for “feedback controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Tungsten control in long pulse operation: feedback from WEST to ITER

The full W environment that is now foreseen for ITER puts strong emphasis on experimental results obtained in present devices in similar conditions. In this context, the WEST tokamak is well equipped to bring key contributions to the preparation of ITER operation, thanks to its capability to perform long pulses in dominant electron heating, torque-free scheme based on RF systems, and its ITER-grade actively cooled divertor. Recent results of interest cover the understanding of tungsten contamination and the evaluation of conditioning methods, the feedback on the current ramp-up phase, and the ageing of the ITER divertor components in L-mode attached condition. Further, new directions are being explored, in particular low divertor temperature operation that should be the normal operating regime of ITER. We also report on tungsten peaking physics, and the role of light impurity content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary design overview and performance assessment of the ITER low-field side reflectometer

The design of the ITER low-field side reflectometer (LFSR) has matured to a complete end-to-end preliminary design. LFSR will supply three key plasma measurements: (1) electron density profile, (2) electron density fluctuations, and (3) poloidal rotation. Simultaneous measurements of the three quantities are enabled by an array of six monostatic antennas which inject from an equatorial port on the outboard side of the ITER vessel. Low-loss transmission lines, consisting of corrugated, overmoded waveguide and miter bends, transmit the 30–165 GHz, O- and X-mode signals to and from the ITER plasma. Integrated transmission-line components serve a range of purposes, such as protection from high-power stray radiofrequency radiation, accommodation of transmission-line displacement, and simultaneous measurement of reference and plasma phases during the discharge. Broadband transmission signals are realized by full-band microwave transceivers combined with quasi-optical multiplexing. A field-programmable gate array (FPGA) processor demodulates the profile reflectometer signals, enabling real-time density profile measurements for plasma control system feedback. A full-scale transmission line test facility provides an integrated environment to assess the performance of critical LFSR components. Theoretical modeling together with insertion loss measurements provide the basis for a comprehensive power budget, which accounts for transmitted output power, transmission-line losses, antenna coupling, and plasma effects. Results indicate that high signal-to-noise ratios are achievable with the current design. A synthetic reflectometer model, using real design parameters and baseline ITER profiles, has been developed to estimate the return signal. With evolving microwave and data acquisition technologies, full-band, ultrafast sweeps (<1 μs) will be realizable for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feedback-based quantum algorithms for ground state preparation

The ground state properties of quantum many-body systems are a subject of interest across chemistry, materials science, and physics. Thus, algorithms for finding ground states can have broad impacts. Variational quantum algorithms are one class of ground state algorithms that has received significant attention in recent years. These algorithms utilize a hybrid quantum-classical computing framework to prepare ground states on quantum computers. However, this requires solving a classical optimization problem that can become prohibitively expensive in high dimensions. Here, we develop formulations of feedback-based quantum algorithms for ground state preparation that can be used to address this challenge for two broad classes of Hamiltonians: Fermi-Hubbard Hamiltonians, and molecular Hamiltonians represented in second quantization. Feedback-based quantum algorithms are optimization-free; in place of classical optimization, quantum circuit parameters are set according to a deterministic feedback law derived from quantum Lyapunov control principles. This feedback law guarantees a monotonic improvement in solution quality with respect to the depth of the quantum circuit. A variety of numerical illustrations are provided that analyze the convergence and robustness of feedback-based quantum algorithms for these problem classes. Published by the American Physical Society 2024

Larsen, James B. (ORCID:000000020777440X)↗

Deep learning-assisted modeling for χ (2) nonlinear optics

Modeling second-order (χ(2)) nonlinear optical processes remains computationally expensive due to the need to resolve fast field oscillations and simulate wave propagation using methods such as the split-step Fourier method (SSFM). This can become a bottleneck in real-time applications, such as high-repetition-rate laser systems requiring rapid feedback and control. We present a long short-term memory-based surrogate model trained on SSFM simulations generated from a start-to-end model of the photocathode drive laser at SLAC National Accelerator Laboratory’s Linac Coherent Light Source II. The model achieves over 250× speedup while maintaining high fidelity, enabling future real-time optimization and laying the foundation for data-integrated modeling frameworks and digital twins of laser systems.

Accelerator Physics (physics.acc-ph)↗

Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU

Purpose: Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in the prostate and to monitor for potential damage to surrounding tissues. This requires that the MR thermometry measurements are an accurate representation of the true tissue temperature. The proton resonance frequency shift thermometry method used is sensitive to tissue motion and changes in the local magnetic susceptibility that can be caused by the motion of air bubbles in the rectum, which can impact the performance of transurethral MR-HIFU in these regions of the gland. Methods: A method is proposed for filtering of temperature artifacts based on the temporal variance of the temperature, using empirical and dynamic positional knowledge of the ultrasonic heating beam, and an estimation of the measurement noise. A two-step correction strategy is introduced which eliminates artifact-detected temperature variations while keeping the noise level low through spatial averaging. Results: The filter has been evaluated by postprocessing data from five human transurethral ultrasound treatments. The two-step correction process led to reduced final temperature standard deviation in the prostate and rectum areas where the artifact was located, without negatively affecting areas distal to the artifact. The performance of the filter was also found to be consistent across all six of the data sets evaluated. The evaluation of the detection criterion parameter M determined that a value of M = 3 achieves a conservative filter with minimal loss of spatial resolution during the process. Conclusions: The filter was able to remove most artifacts due to the presence of moving air bubbles in the rectum during transurethral MR-HIFU. A quantitative estimation of the filter capabilities shows a systematic improvement in the standard deviation of the corrected temperature maps in the rectum zone as well as in the entire acquired slice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oxygen-Fired CO 2 Recycle for Application to Direct CO 2 Capture form Coal-Fired Power Plants

The Southern Research/Southern Company 1 MWth Pilot-Scale Coal-Fired Test Facility was successfully retrofit to fire in either the traditional air-fired mode or with 100% oxygen and recycled flue gas, with a fully integrated feedback and control system, including oxygen and recycled flue gas modulation during startup, transfer, and shutdown, safety and operational interlocks, and data acquisition. A MAXON Staged Oxygen Burner for Oxy-Coal Applications produced a stable flame over a significant range of firing turn-down, staging, and while firing five different U.S. coal types. The MAXON burner design produces lower flame temperatures than for air firing, which will enable (A) Safe operation, (B) Reduction of recycle flow without concern about furnace flame temperatures, and (C) May likely be affective at reducing slagging and fouling in the boiler and super heater at full-scale Power Plants. A CFD model of the Oxy-fired Combustion Research Facility (OCRF) was used to predict the flame geometry and temperatures in the OCRF and make a comparison with the air-fired case. The model predictions were consistent with the experimental data in showing that the MAXON burner fired with oxygen produced lower flame temperatures than the air-fired burner while firing with air.

01 COAL, LIGNITE, AND PEAT↗

Development of Laboratory Test Methods for Low-Cost Indoor Air Quality Sensors

This report describes the development of two standard test methods: one for evaluating PM2.5 sensors; and the other for evaluating CO 2 Sensors. The standards were developed to provide a pathway for the use of reliable, low-cost indoor air quality sensors as occupant feedback, ventilation control, and overall indoor air quality improvement. This paper describes the development process and technical issues involved.

30 DIRECT ENERGY CONVERSION↗

DME-to-Propane Mixture Effects on a Light Duty Compression Ignition Engine

Fuels that can be produced in a sustainable manner are of high interest because they can provide an essential step toward net zero emissions vehicles. This study examines the combustion of two such fuels, Dimethyl Ether (DME) and propane, in a compression ignition, 4-cylinder, 2.2L engine running with mixtures of DME-to-Propane ranging of 100%-0%, 85%-15%, 75%-25%, and 65%-35% by weight. Testing was conducted at 2000rpm - 100Nm, an important representative point in the FTP certification cycle. For each fuel mixture, conditions tested include sweeps of boost, EGR and injection pressure. Here, tests are mainly conducted at a constant combustion timing with CA10 of -1 deg with respect to TDC, with an engine controller combustion feedback system based on in-cylinder sampling of pressure. Trends of NOx, HC, and CO are similar for the range of DME-to-propane, from 100%-0% to 75%-25%. Boost and injection pressures had the most notable impact on the heat release traces. Higher boost, from stoichiometric to lean resulted in approximately a 3-5% increase on cycle efficiency. Fuel injection pressures resulted in about 1% gain per 200bar. Results also illustrated that EGR is effective in reducing NOx but causes notable degradation of cycle efficiency. The emissions for DME-propane mixtures with 65%-35% had a different trend, with CO and HC exceeding the runs with lower propane content by 2 to 3-fold. As propane content increases, the pressure rise rates become higher, and with 65%-35% mixtures, rates easily exceed 12bar/deg. The increased rise rates correlate with early injection timings but the rates can be reduced, with higher boost and lower injection pressures. The result of the approach, however, leads to lower thermal efficiencies, decreasing efficiency by over 5% between neat DME and the highest propane ratios.

Combustion and combustion processes↗

Means and methods for cytometric therapies

A functionalized tip is incorporated into catheters for the cytometric delivery of cells into the brain and other body parts. For use in the brain, the tip forms part of a neurosurgical probe having a proximal end and a distal end. In addition to the functionalized tip, the probe has at least one cell slurry delivery lumen and a plurality of optical fibers configured along the probe, terminating in the tip to provide the photo-optical capability needed to monitor the viability and physiological behavior of the grafted cells as well as certain characteristics of the cellular environment. Details are also presented of the use of a neurocatheter having a cytometric tip of the type disclosed in the invention, as employed within the context of a feedback and control system for regulating the number of cells delivered to the brain of a patient.

60 APPLIED LIFE SCIENCES↗

Means and methods for cytometric therapies

A functionalized tip is incorporated into catheters for the cytometric delivery of cells into the brain and other body parts. For use in the brain, the tip forms part of a neurosurgical probe having a proximal end and a distal end. In addition to the functionalized tip, the probe has at least one cell slurry delivery lumen and a plurality of optical fibers configured along the probe, terminating in the tip to provide the photo-optical capability needed to monitor the viability and physiological behavior of the grafted cells as well as certain characteristics of the cellular environment. Details are also presented of the use of a neurocatheter having a cytometric tip of the type disclosed in the invention, as employed within the context of a feedback and control system for regulating the number of cells delivered to the brain of a patient.

60 APPLIED LIFE SCIENCES↗

Multi-mode ultrasonic welding control and optimization

A system and method for providing multi-mode control of an ultrasonic welding system. In one embodiment, the control modes include the energy of the weld, the time of the welding process and the compression displacement of the parts being welded during the welding process. The method includes providing thresholds for each of the modes, and terminating the welding process after the threshold for each mode has been reached, the threshold for more than one mode has been reached or the threshold for one of the modes has been reached. The welding control can be either open-loop or closed-loop, where the open-loop process provides the mode thresholds and once one or more of those thresholds is reached the welding process is terminated. The closed-loop control provides feedback of the weld energy and/or the compression displacement so that the weld power and/or weld pressure can be increased or decreased accordingly.

42 ENGINEERING↗

Spatially Resolved Mapping of Electrical Conductivity around Individual Domain (Grain) Boundaries in Graphene

Graphene films can now be produced on the scale of up to meters. However, all large-scale graphene films contain topological defects that can significantly affect the characteristic transport behaviors of graphene. Here, we spatially map the structures and electronic transport near specific domain and grain boundaries in graphene, and evaluate effects of different types of defect on the electronic conductivity in epitaxial graphene grown on SiC and CVD graphene on Cu subsequently transferred to a SiO2 substrate. We use a combined approach with a multi-probe scanning tunneling potentiometry to investigate both structures and transport at individual grain boundaries and domain boundaries that are defined by coalesced grains, surface steps, and changes in layer thickness. It is found that the substrate step on SiC presents a significant potential barrier for electron transport of epitaxial graphene due to the reduced charge transport from the substrate at the step edges, monolayer-bilayer boundaries exhibit a high resistivity that can change depending on directions of the current across the boundary, and the resistivity of grain boundaries changes with the transition width of the disordered region between two adjacent grains in graphene. The detailed understanding of graphene defects will provide the feedback for controlled engineering of defects in large-scale graphene films.

Li, An-Ping↗

Proposed New Accelerator Design for Homeland Security X-Ray Applications

In the security and inspection market, there is a push towards highly mobile, reduced-dose active interrogation scanning and imaging systems to allow operation in urban environments. To achieve these goals, the accelerator system design needs to be smaller than existing systems. A smaller radiation exclusion zone may be accomplished through better beam collimation and an integrated, x-ray-source/detector-array assembly to allow feedback and control of an intensity-modulated x-ray source. A shaped low-Z target in the x-ray source can be used to generate a more forward peaked x-ray beam. Electron-beam steering can then be applied to direct the forward-peaked x rays toward areas in the cargo with high attenuation. This paper presents an exploratory study to identify components and upgrades that would be required to meet the desired specifications, as well as the best technical approach to design and build a prototype.

43 PARTICLE ACCELERATORS↗

Final report

Explore the source record for details and available documents.

20 FOSSIL-FUELED POWER PLANTS↗

Mode matching method for absorption spectroscopy systems

Systems and methods for controlling optical feedback in an optical system. A resonant optical cavity includes at least two cavity mirrors, one of which is a cavity coupling mirror, and has a plurality of optical resonance cavity modes. A radiation source emits a beam of continuous wave radiation and is capable of being scanned whereby a mean optical frequency of the continuous wave radiation beam is adjustable over a range of frequencies, wherein the radiation source is responsive to optical feedback radiation emerging from the cavity, and wherein the mode matching optics couples the beam of continuous wave radiation to the cavity via the cavity coupling mirror. The radiation source and the mode matching optics are aligned so that a mode fill ratio is reduced relative to a maximum mode fill ratio, wherein the laser beam is coupled with a fundamental cavity mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Taming the Wild World of Management, Performance and Communication - 13459

Management has evolved a long way from its original meaning of 'governing a horse'. The industrial revolution fostered 'scientific management'; 1930's Hawthorne studies discovered that people's social interactions could alter productivity; and the dawn of the computer age in the post-war 1950's brought general systems theory into management thinking. Today, mobile wireless connectivity aims to transform ever-changing networks of players, mandates, and markets into something that can be 'managed'. So why is there no clear and simple recipe for how to practice management? We talk about financial management, safety management, and operations management, but surely the 'management' part of those endeavors will share the same set of practices. Instead, we are still arguing for 'management' to include everything from developing people to negotiating contracts. A manager's job may include many things, but one of them, the job of management, needs to be nailed down. Three standard practices for managing in a network are developed: (a) support the dialogues that connect people vital to accomplishing a goal or objective; (b) develop and sustain the scoreboards that serve as a road-map to reach the goal; and (c) control the feedback to 'govern the horse'. These three practices are useful for more than reaching goals, as they also support coordinating across boundaries and running productive meetings. The dialogues for productive relationships, scoreboards for goals and deliverables, and feedback for performance together constitute a recipe for managing in a networked world. (authors)

99 GENERAL AND MISCELLANEOUS↗