Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

On detrending stream velocity time series for robust tidal flow turbulence characterization

We investigated the impact of detrending techniques on turbulence quantities from tidal stream flow data, focusing on the autocorrelation function, $ρ_{uu}$, and velocity spectrum, $Φ(f)$. Standard detrending methods, including high-pass frequency-based and polynomial-based techniques, are examined, alongside a proposed alternative method, the empirical mode decomposition (EMD). Our results highlight that intervals of flow acceleration and deceleration, typical in tidal and riverine flows, significantly affect the estimation of turbulence quantities using high-pass frequency filtering and polynomial detrending of varying orders. These methods can strongly influence $ρ_{uu}$ and $Φ(f)$, thereby affecting the accurate estimation of derived quantities. We examine two variations of detrending data using EMD; the first removes only the EMD residue, and the second removes both the residue and the largest scale intrinsic mode function (IMF). By comparing the detrended spectra with the modeled von Kármán spectra, we demonstrate that the second variation (i.e., removing the residue and the largest scale IMF) successfully removed the large-scale trend of the data while retaining the energy of other scales.

Detrend↗

An Adaptive Fourier Filter for Relaxing Time Stepping Constraints for Explicit Solvers

Filtering is necessary to stabilize piecewise smooth solutions. The resulting diffusion stabilizes the method, but may fail to resolve the solution near discontinuities. Moreover, high order filtering still requires cost prohibitive time stepping. This paper introduces an adaptive filter that controls spurious modes of the solution, but is not unnecessarily diffusive. Consequently we are able to stabilize the solution with larger time steps, but also take advantage of the accuracy of a high order filter.

Gelb, Anne↗

MO-FG-CAMPUS-IeP1-01: Alternative K-Edge Filters for Low-Energy Image Acquisition in Contrast Enhanced Spectral Mammography

Purpose: In Contrast Enhanced Spectral Mammography (CESM), Rh filter is often used during low-energy image acquisition. The potential for using Ag, In and Sn filters, which exhibit K-edge closer to, and just below that of Iodine, instead of the Rh filter, was investigated for the low-energy image acquisition. Methods: Analytical computations of the half-value thickness (HVT) and the photon fluence per mAs (photons/mm2/mAs) for 50µm Rh were compared with other potential K-edge filters (Ag, In and Sn), all with K-absorption edge below that of Iodine. Two strategies were investigated: fixed kVp and filter thickness (50µm for all filters) resulting in HVT variation, and fixed kVp and HVT resulting in variation in Ag, In and Sn thickness. Monte Carlo simulations (GEANT4) were conducted to determine if the scatter-to-primary ratio (SPR) and the point spread function of scatter (scatter PSF) differed between Rh and other K-edge filters. Results: Ag, In and Sn filters (50µm thick) increased photon fluence/mAs by 1.3–1.4, 1.8–2, and 1.7–2 at 28-32 kVp compared to 50µm Rh, which could decrease exposure time. Additionally, the fraction of spectra closer to and just below Iodine’s K-edge increased with these filters, which could improve post-subtraction image contrast. For HVT matched to 50µm Rh filtered spectra, the thickness range for Ag, In, and Sn were (41,44)µm, (49,55)µm and (45,53)µm, and increased photon fluence/mAs by 1.5–1.7, 1.6–2, and 1.6–2.2, respectively. Monte Carlo simulations showed that neither the SPR nor the scatter PSF of Ag, In and Sn differed from Rh, indicating no additional detriment due to x-ray scatter. Conclusion: The use of Ag, In and Sn filters for low-energy image acquisition in CESM is potentially feasible and could decrease exposure time and may improve post-subtraction image contrast. Effect of these filters on radiation dose, contrast, noise and associated metrics are being investigated. Funding Support: Supported in part by NIH R01CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Silicon on-chip bandpass filters for the multiplexing of high sensitivity photonic crystal microcavity biosensors

A method for the dense integration of high sensitivity photonic crystal (PC) waveguide based biosensors is proposed and experimentally demonstrated on a silicon platform. By connecting an additional PC waveguide filter to a PC microcavity sensor in series, a transmission passband is created, containing the resonances of the PC microcavity for sensing purpose. With proper engineering of the passband, multiple high sensitivity PC microcavity sensors can be integrated into microarrays and be interrogated simultaneously between a single input and a single output port. The concept was demonstrated with a 2-channel L55 PC biosensor array containing PC waveguide filters. The experiment showed that the sensors on both channels can be monitored simultaneously from a single output spectrum. Less than 3 dB extra loss for the additional PC waveguide filter is observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positivity enhancements to the P n transport equations

One of the common methods for solving the radiation transport equation is to use a polynomial expansion for the angle variable(s). Here, while each solution technique has its disadvantages, in some instances this method can result in oscillations large enough to give a negative radiation energy density, which is nonphysical. Some authors have recast the closure of the transport equations to guarantee positivity. Unfortunately, this results in messy nonlinear equations. Other authors post process each time step’s solution to improve positivity. In this work, the P n equations are modified to be more diffusive, less oscillatory, more positive, and more accurate. No new solution techniques are required, just the scaling of some terms with constant factors and the addition of constant filter opacities; therefore, the solutions are still linear. This new solution method is called stretched and filtered P n . Test problems are presented in one and two dimensions. Comparisons to the D n and TP n closures are made in one dimension. Modifications to D n and TP n are suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parallelized Kalman-Filter-Based Reconstruction of Particle Tracks on Many-Core Processors and GPUs

For over a decade now, physical and energy constraints have limited clock speed improvements in commodity microprocessors. Instead, chipmakers have been pushed into producing lower-power, multi-core processors such as Graphical Processing Units (GPU), ARM CPUs, and Intel MICs. Broad-based efforts from manufacturers and developers have been devoted to making these processors user-friendly enough to perform general computations. However, extracting performance from a larger number of cores, as well as specialized vector or SIMD units, requires special care in algorithm design and code optimization. One of the most computationally challenging problems in high-energy particle experiments is finding and fitting the charged-particle tracks during event reconstruction. This is expected to become by far the dominant problem at the High-Luminosity Large Hadron Collider (HL-LHC), for example. Today the most common track finding methods are those based on the Kalman filter. Experience with Kalman techniques on real tracking detector systems has shown that they are robust and provide high physics performance. This is why they are currently in use at the LHC, both in the trigger and offine. Previously we reported on the significant parallel speedups that resulted from our investigations to adapt Kalman filters to track fitting and track building on Intel Xeon and Xeon Phi. Here, we discuss our progresses toward the understanding of these processors and the new developments to port the Kalman filter to NVIDIA GPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autodifferentiable Ensemble Kalman Filters

Data assimilation is concerned with sequentially estimating a temporally evolving state. This task, which arises in a wide range of scientific and engineering applications, is particularly challenging when the state is high-dimensional and the state-space dynamics are unknown. This paper introduces a machine learning framework for learning dynamical systems in data assimilation. Here, our auto-differentiable ensemble Kalman filters (AD-EnKFs) blend ensemble Kalman filters for state recovery with machine learning tools for learning the dynamics. In doing so, AD-EnKFs leverage the ability of ensemble Kalman filters to scale to high-dimensional states and the power of automatic differentiation to train high-dimensional surrogate models for the dynamics. Numerical results using the Lorenz-96 model show that AD-EnKFs outperform existing methods that use expectation-maximization or particle filters to merge data assimilation and machine learning. In addition, AD-EnKFs are easy to implement and require minimal tuning.

autodifferentiation↗

Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging

Purpose: The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of this study was to measure the spatial resolution of a commercially available IR method using ensemble-averaged images acquired from repeated scans. Methods: A low-contrast phantom containing three rods (7, 14, and 21 HU below background) was scanned on a 128-slice CT scanner at three dose levels (CTDI{sub vol} = 16, 8, and 4 mGy). Images were reconstructed using two filtered-backprojection (FBP) kernels (B40 and B20) and a commercial IR method (sinogram affirmed iterative reconstruction, SAFIRE, Siemens Healthcare) with two strength settings (I40-3 and I40-5). The same scan was repeated 100 times at each dose level. The modulation transfer function (MTF) was calculated based on the edge profile measured on the ensemble-averaged images. Results: The spatial resolution of the two FBP kernels, B40 and B20, remained relatively constant across contrast and dose levels. However, the spatial resolution of the two IR kernels degraded relative to FBP as contrast or dose level decreased. For a given dose level at 16 mGy, the MTF{sub 50%} value normalized to the B40 kernel decreased from 98.4% at 21 HU to 88.5% at 7 HU for I40-3 and from 97.6% to 82.1% for I40-5. At 21 HU, the relative MTF{sub 50%} value decreased from 98.4% at 16 mGy to 90.7% at 4 mGy for I40-3 and from 97.6% to 85.6% for I40-5. Conclusions: A simple technique using ensemble averaging from repeated CT scans can be used to measure the spatial resolution of IR techniques in CT at very low contrast levels. The evaluated IR method degraded the spatial resolution at low contrast and high noise levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Jacobian sparsity detection using Bloom filters

Determining Jacobian sparsity structure is an important step in the efficient computation of sparse Jacobians. We introduce a new method for determining Jacobian sparsity patterns by combining bit vector probing with Bloom filters. In conclusion, we further refine Bloom filter probing by combining it with hierarchical probing to yield a highly effective strategy for Jacobian sparsity pattern determination.

Bloom filter↗

Automated bone removal in CT angiography: Comparison of methods based on single energy and dual energy scans

Purpose: To evaluate dual energy based methods for bone removal in computed tomography angiography (CTA) images and compare these with single energy based methods that use an additional, nonenhanced, CT scan. Methods: Four different bone removal methods were applied to CT scans of an anthropomorphic thorax phantom, acquired with a second generation dual source CT scanner. The methods differed by the way information on the presence of bone was obtained (either by using an additional, nonenhanced scan or by scanning with two tube voltages at the same time) and by the way the bone was removed from the CTA images (either by masking or subtracting the bone). The phantom contained parts which mimic vessels of various diameters in direct contact with bone. Both a quantitative and qualitative analysis of image quality after bone removal was performed. Image quality was quantified by the contrast-to-noise ratio (CNR) normalized to the square root of the dose (CNRD). At locations where vessels touch bone, the quality of the bone removal and the vessel preservation were visually assessed. The dual energy based methods were assessed with and without the addition of a 0.4 mm tin filter to the high voltage x-ray tube filtration. For each bone removal method, the dose required to obtain a certain CNR after bone removal was compared with the dose of a reference scan with the same CNR but without automated bone removal. The CNRD value of the reference scan was maximized by choosing the lowest tube voltage available. Results: All methods removed the bone completely. CNRD values were higher for the masking based methods than for the subtraction based methods. Single energy based methods had a higher CNRD value than the corresponding dual energy based methods. For the subtraction based dual energy method, tin filtration improved the CNRD value with approximately 50%. For the masking based dual energy method, it was easier to differentiate between iodine and bone when tin filtration was applied. The CNRD value decreased only with 4% in that case. Compared to the dual scan based methods, the dual energy based methods had the advantage that only a single scan was made without the need of image registration. This might be easier to implement in clinical practice. Vessel preservation was better with bone subtraction than with bone masking. Smaller vessels were completely occluded by the bone mask. None of the bone removal methods was dose neutral. Conclusions: In general, dual scan based methods that use the lowest tube voltage available, have a higher CNR than the dual energy based approaches at the same dose level. Tin filtration improves the ability to differentiate between iodine and bone for the dual energy based masking method. In clinical practice, the advantages of the dual energy masking method might outweigh its disadvantage of a slightly higher dose penalty compared to the conventional dual scan masking method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRB-05: Automation of the Photon Dosimetric Quality Assurance Program of a Linear Accelerator

Purpose: To develop an automated method to calculate a linear accelerator (LINAC) photon radiation field size, flatness, symmetry, output and beam quality in a single delivery for flattened (FF) and flattening-filter-free (FFF) beams using an ionization chamber array. Methods: The proposed method consists of three control points that deliver 30×30, 10×10 and 5×5cm{sup 2} fields (FF or FFF) in a step-and-shoot sequence where the number of monitor units is weighted for each field size. The IC Profiler (Sun Nuclear Inc.) with 5mm detector spacing was used for this study. The corrected counts (CCs) were calculated and the locations of the maxima and minima values of the first-order gradient determined data of each sub field. Then, all CCs for each field size are summed in order to obtain the final profiles. For each profile, the radiation field size, symmetry, flatness, output factor and beam quality were calculated. For field size calculation, a parameterized gradient method was used. For method validation, profiles were collected in the detector array both, individually and as part of the step-and-shoot plan, with 9.9cm buildup for FF and FFF beams at 90cm source-to-surface distance. The same data were collected with the device (plus buildup) placed on a movable platform to achieve a 1mm resolution. Results: The differences between the dosimetric quantities calculated from both deliveries, individually and step-and-shoot, were within 0.31±0.20% and 0.04±0.02mm. The differences between the calculated field sizes with 5mm and 1mm resolution were ±0.1mm. Conclusion: The proposed single delivery method proved to be simple and efficient in automating the photon dosimetric monthly and annual quality assurance.

61 RADIATION PROTECTION AND DOSIMETRY↗

ATMOSPHERIC IMAGING ASSEMBLY OBSERVATIONS OF CORONAL LOOPS: CROSS-FIELD TEMPERATURE DISTRIBUTIONS

We construct revised response functions for the Atmospheric Imaging Assembly (AIA) using the new atomic data, ionization equilibria, and coronal abundances available in CHIANTI 7.1. We then use these response functions in multithermal analysis of coronal loops, which allows us to determine a specific cross-field temperature distribution without ad hoc assumptions. Our method uses data from the six coronal filters and the Monte Carlo solutions available from our differential emission measure (DEM) analysis. The resulting temperature distributions are not consistent with isothermal plasma. Therefore, the observed loops cannot be modeled as single flux tubes and must be composed of a collection of magnetic strands. This result is now supported by observations from the High-resolution Coronal Imager, which show fine-scale braiding of coronal strands that are reconnecting and releasing energy. Multithermal analysis is one of the major scientific goals of AIA, and these results represent an important step toward the successful achievement of that goal. As AIA DEM analysis becomes more straightforward, the solar community will be able to take full advantage of the state-of-the-art spatial, temporal, and temperature resolution of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Point-of-use filtration units as drinking water distribution system sentinels

Abstract Municipal drinking water distribution systems (DWDSs) and associated premise plumbing (PP) systems are vulnerable to proliferation of opportunistic pathogens, even when chemical disinfection residuals are present, thus presenting a public health risk. Monitoring the structure of microbial communities of drinking water is challenging because of limited continuous access to faucets, pipes, and storage tanks. We propose a scalable household sampling method, which uses spent activated carbon and reverse osmosis (RO) membrane point-of-use (POU) filters to evaluate mid- to long-term occurrence of microorganisms in PP systems that are relevant to consumer exposure. As a proof of concept, POU filter microbiomes were collected from four different locations and analyzed with 16S rRNA gene amplicon sequencing. The analyses revealed distinct microbial communities, with occasional detection of potential pathogens. The findings highlight the importance of local, and if possible, continuous monitoring within and across distribution systems. The continuous operation of POU filters offers an advantage in capturing species that may be missed by instantaneous sampling methods. We suggest that water utilities, public institutions, and regulatory agencies take advantage of end-of-life POU filters for microbial monitoring. This approach can be easily implemented to ensure drinking water safety, especially from microbes of emerging concerns; e.g., pathogenic Legionella and Mycobacterium species.

42 ENGINEERING↗

SU-E-T-525: Ionization Chamber Perturbation in Flattening Filter Free Beams

Purpose: Changing the characteristic of a photon beam by mechanically removing the flattening filter may impact the dose response of ionization chambers. Thus, perturbation factors of cylindrical ionization chambers in conventional and flattening filter free photon beams were calculated by Monte Carlo simulations. Methods: The EGSnrc/BEAMnrc code system was used for all Monte Carlo calculations. BEAMnrc models of nine different linear accelerators with and without flattening filter were used to create realistic photon sources. Monte Carlo based calculations to determine the fluence perturbations due to the presens of the chambers components, the different material of the sensitive volume (air instead of water) as well as the volume effect were performed by the user code egs-chamber. Results: Stem, central electrode, wall, density and volume perturbation factors for linear accelerators with and without flattening filter were calculated as a function of the beam quality specifier TPR{sub 20/10}. A bias between the perturbation factors as a function of TPR{sub 20/10} for flattening filter free beams and conventional linear accelerators could not be observed for the perturbations caused by the components of the ionization chamber and the sensitive volume. Conclusion: The results indicate that the well-known small bias between the beam quality correction factor as a function of TPR20/10 for the flattening filter free and conventional linear accelerators is not caused by the geometry of the detector but rather by the material of the sensitive volume. This suggest that the bias for flattening filter free photon fields is only caused by the different material of the sensitive volume (air instead of water)

60 APPLIED LIFE SCIENCES↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval

We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationship correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generic inference of inflation models by non-Gaussianity and primordial power spectrum reconstruction

We present a generic inference method for inflation models from observational data by the usage of higher-order statistics of the curvature perturbation on uniform density hypersurfaces. This method is based on the calculation of the posterior for the primordial non-Gaussianity parameters f{sub NL} and g{sub NL}, which in general depend on specific parameters of inflation and reheating models, and enables to discriminate among the still viable inflation models. To keep analyticity as far as possible to dispense with numerically expensive sampling techniques a saddle-point approximation is introduced, whose precision is validated for a numerical toy example. The mathematical formulation is done in a generic way so that the approach remains applicable to cosmic microwave background data as well as to large scale structure data. Additionally, we review a few currently interesting inflation models and present numerical toy examples thereof in two and three dimensions to demonstrate the efficiency of the higher-order statistics method. A second quantity of interest is the primordial power spectrum. Here, we present two Bayesian methods to infer it from observational data, the so called critical filter and an extension thereof with smoothness prior, both allowing for a non-parametric spectrum reconstruction. These methods are able to reconstruct the spectra of the observed perturbations and the primordial ones of curvature perturbation even in case of non-Gaussianity and partial sky coverage. We argue that observables like T- and B-modes permit to measure both spectra. This also allows to infer the level of non-Gaussianity generated since inflation.

79 ASTRONOMY AND ASTROPHYSICS↗