Search NASA⌕ Search

SEARCH · Search NASA

Results for “flash”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Measuring x-ray spectra of flash radiographic sources [PowerPoint]

The x-ray spectra of flash radiographic sources are difficult to measure. The sources measured were Radiographic Integrated Test Stand-6 (370 rad at 1 m; 50 ns pulse) and Dual Axis Radiographic Hydrodynamic Test Facility (DARHT) (550 rad at 1 m; 50 ns pulse). Features of the Compton spectrometer are described, and spectra are shown. Additional slides present data on instrumental calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods of flash sintering

This disclosure provides methods of flash sintering and compositions created by these methods. Methods for sintering multilayered bodies are provided in which a sintered body is produced in less than one minute. In one aspect, each layer is of a different composition, and may be constituted wholly from a ceramic or from a combination of ceramic and metallic particles. When the body includes a layer of an anode composition, a layer of an electrolyte composition and a layer of a cathode composition, the sintered body can be used to produce a solid oxide fuel cell.

30 DIRECT ENERGY CONVERSION↗

HOM Choice Study with Test Electronics for use as Beam Position Diagnostics in 3.9 GHz Accelerating Cavities in FLASH

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 \mu m was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.

43 PARTICLE ACCELERATORS↗

Flashing ratchets

Provided herein are flashing ratchets that produce transport based on the oscillating application of regularly-spaced, asymmetric potentials. In particular, devices are provided that transport electrons without the requirement of an overall source-drain bias favoring electron transport.

42 ENGINEERING↗

Flash ironmaking drop tube furnace system

A flash ironmaking drop tube furnace includes a primary reaction section having a refractory, an induction coil around the refractory, insulation located between the refractory and the induction coil, and a susceptor located inside the refractory, the susceptor being formed of a material that is heated by induction when electrical current flows through the induction coil, and having at least one interior channel through which particles can pass. The furnace further includes a muffle, located below the primary reaction section; an outer shell surrounding the muffle; at least one heater located adjacent to the muffle; insulation located between the at least one heater and the outer shell; at least one particle feeder that feeds a predetermined volume of particles into the furnace above the primary reaction section; and an inlet port for injecting gas into the furnace, the inlet port being located so that the gas flows through the susceptor and muffle in parallel with the particles.

Green, Edward↗

Flash radiotherapy accelerator

Methods, devices and systems for ultra-high dose radiotherapy are disclosed. The described techniques rely in-part on active switching control of a photoconductive switch during the time the accelerator is accelerating charged particles to produce the output radiation at the desired dose rates. One flash radiotherapy system includes an induction accelerator, and a controllable switch coupled to the induction accelerator. The switch is operable to produce a plurality of voltage pulses to drive the induction accelerator. The radiotherapy system also includes a radiation measurement device to measure output radiation produced by the radiotherapy system and provide feedback to the controllable switch. The controllable switch is operable to, based on the received feedback, modify an amplitude, shape, spacing, number or width of the voltage pulses that are supplied to the particle accelerator to deliver the desired output radiation.

Sampayan, Stephen E.↗

Measurement of thermal gap conductance using the laser flash method

Thermal gap conductance refers to overall heat conductance through a gas-filled gap as interface thermal resistance between the gas and surface has to be considered. The analysis of new ATR (Advanced Test Reactor) fuel experiments requires experimental data and models for the gap conductance of the cladding/fuel capsule gap, which typically varies from 5 μm to 50 μm and is filled with He at 1-3 atm. Although past research has studied the gap conductance between UO{sub 2} fuel and Zircaloy cladding, new experiments are needed to provide the gap conductance data between HT9 and stainless steel 316, and between advanced fuels and advanced cladding in the Accident Tolerant Fuels program. In this paper, the laser flash method is modified to measure the gap conductance. The gap is formed by welding two stainless steel 316 disks with three spacers. The temperature at the rear surface, after exposure to the laser pulse at the front surface, is modeled with 1D heat transfer through three layers. The analytic solution is then fitted with the measured temperature to determine gap conductance. The sensitivity analysis based on the 1D assumption and 3D numerical simulations were performed to assess the sensitivity and uncertainty of the measurement. It is concluded the heat capacity of the gas in the gap has minimal impact on the measurement, which indicates that the thermal property determined by this method is the thermal conductance, instead of the thermal diffusivity. Convective heat loss through sidewalls under the current experimental design has insignificant influences. Heat transfer through spacers may cause up to 10% overestimation of thermal gap conductance, but the effects can be mostly eliminated by the design of grooves on samples. The result established a pathway for gap conductance determination. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scannerless loss modulated flash color range imaging

Scannerless loss modulated flash color range imaging methods and apparatus are disclosed for producing three dimensional (3D) images of a target within a scene. Apparatus and methods according to the present invention comprise a light source providing at least three wavelengths (passbands) of illumination that are each loss modulated, phase delayed and simultaneously directed to illuminate the target. Phase delayed light backscattered from the target is spectrally filtered, demodulated and imaged by a planar detector array. Images of the intensity distributions for the selected wavelengths are obtained under modulated and unmodulated (dc) illumination of the target, and the information contained in the images combined to produce a 3D image of the target.

47 OTHER INSTRUMENTATION↗

Monitoring the FLASH Cryomodule Transportation from DESY Hamburg to CEA Saclay: Coupler Contact, Vacuum, Acceleration and Vibration Analysis

With a view to the series production of one hundred, 12 m long XFEL 1.3 GHz cryomodules and their transportation from the assembly site at CEA Saclay (F) to the installation site at DESY Hamburg (D) a test transportation of a FLASH cryomodule has been performed, in the condition foreseen for the mass transportation. The present study examines the stresses induced on the module and verifies the damping capabilities of the transport frame in order to minimize risk of damage to the most critical components. During the transportation, acceleration and vibration have been monitored as well as coupler antenna contacts and vacuum performances. This paper describes the analysis performed and compares those results to the data of a similar transportation study at Fermilab for the CM1 cryomodule.

43 PARTICLE ACCELERATORS↗

FLASH Beam-Off RF Measurements and Analyses

The FLASH L-band (1.3 GHz) superconducting accelerator facility at DESY has a Low Level RF (LLRF) system that is similar to that envisioned for ILC. This system has extensive monitoring capability and was used to gather performance data relevant to ILC. In particular, waveform data were recorded with beam off for three, 8-cavity cryomodules to evaluate the input rf stability, perturbations to the SC cavity frequencies and the rf overhead required to achieve constant gradient during the 800-s pulses. In this paper, we discuss the measurements and data analysis procedures and present key findings on the pulse-to-pulse input rf and cavity field stability.

43 PARTICLE ACCELERATORS↗

Analysis of DESY-Flash LLRF Measurements for the ILC Heavy Beam Loading Test

In September 2008 the DESY-FLASH accelerator was run with up to 550, 3 nano-coulomb bunches at 5 Hz repetition rate. This test is part of a longer-term study aimed at validating ILC parameters by operation as close as possible to ILC beam currents and RF gradients. The present paper reports on the analysis that has been done in order to understand the RF control system performance during this test. Actual klystron power requirements and beam stability are evaluated with heavy beam loading conditions. Results include suggested improvements for upcoming tests in 2009.

43 PARTICLE ACCELERATORS↗

Scannerless loss modulated flash color range imaging

Scannerless loss modulated flash color range imaging methods and apparatus are disclosed for producing three dimensional (3D) images of a target within a scene. Apparatus and methods according to the present invention comprise a light source providing at least three wavelengths (passbands) of illumination that are each loss modulated, phase delayed and simultaneously directed to illuminate the target. Phase delayed light backscattered from the target is spectrally filtered, demodulated and imaged by a planar detector array. Images of the intensity distributions for the selected wavelengths are obtained under modulated and unmodulated (dc) illumination of the target, and the information contained in the images combined to produce a 3D image of the target.

47 OTHER INSTRUMENTATION↗

Single Particle Difraction at FLASH

Single-pulse coherent diffraction patterns have been collected from randomly injected single particles with a soft X-ray free-electron laser (FEL). The intense focused FEL pulse gives a high-resolution low-noise coherent diffraction pattern of the object before that object turns into a plasma and explodes. A diffraction pattern of a single particle will only be recorded when the particle arrival into the FEL interaction region coincides with FEL pulse arrival and detector integration. The properties of the experimental apparatus coinciding with these three events set the data acquisition rate. For our single particle FLASH diffraction imaging experiments: (1) an aerodynamic lens stack prepared a particle beam that consisted of particles moving at 150-200 m/s positioned randomly in space and time, (2) the 10 fs long FEL pulses were delivered at a fixed rate, and (3) the detector was set to integrate and readout once every two seconds. The effect of these experimental parameters on the rate of data acquisition using randomly injected particles will be discussed. Overall, the ultrashort FEL pulses do not set the limit of the data acquisition, more important is the effective interaction time of the particle crossing the FEL focus, the pulse sequence structure and the detector readout rate. Example diffraction patterns of randomly injected ellipsoidal iron oxide nanoparticles in different orientations are presented. This is the first single particle diffraction data set of identical particles in different orientations collected on a shot-to-shot basis. This data set will be used to test algorithms for recovering 3D structure from single particle diffraction.

36 MATERIALS SCIENCE↗

Investigating two-photon double ionization of D2 by XUV-Pump -- XUV-Probe experiments at FLASH

Using a novel split-mirror set-up attached to a Reaction Microscope at the Free electron LASer in Hamburg (FLASH) we demonstrate an XUV-pump -- XUV-probe ((hbar omega = 38 eV) experiment by tracing the ultra-fast nuclear wave-packet motion in the D2+ (1s sigma g-state) with<10 fs time resolution. Comparison with time-dependent calculations yields excellent agreement with the measured vibrational period of 22+-4 fs in D2+, points to the importance of the inter-nuclear distance dependent ionization probability and paves the way to control sequential and non-sequential two-photon double ionization contributions.

43 PARTICLE ACCELERATORS↗

Experimental investigations on flashing-induced instabilities in one and two-parallel channels: A comparative study

In this investigation, experiments conducted in a natural circulation test facility at low power and low pressure conditions, in the one single and two-parallel channels configuration are presented and discussed in detail. The novel manner of visualizing the results allowed characterizing the facility at any time and position which helped to thoroughly understand the instability mechanisms. Different modes were observed for each configuration. In the case of having two-parallel channels, four different behaviors have been observed: stable flow circulation, periodic high subcooling oscillations, a-periodical oscillations and out-of-phase periodical oscillations. In addition, stability maps were constructed in order to clarify the region in which each mode is dominant. The results obtained from both the one and two-parallel channels configurations are thus analyzed and compared. As a result, some similarities have been observed between the intermittent flow oscillations found in the single channel experiments and the high subcooling oscillations found in the two-parallel channels experiments. Moreover, similarities have also been found between the sinusoidal flow oscillations existing in the single channel experiments and the out-of-phase oscillations from the two-parallel channels experiments. The experiments presented in this work can be used to benchmark numerical codes and modeling techniques developed to study the start-up of natural circulation BWRs. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Investigation of Aerosol Indirect Effects on Simulated Flash-flood Heavy Rainfall over Korea

This study investigates aerosol indirect effects on the development of heavy rainfall near Seoul, South Korea, on 12 July 2006, focusing on precipitation amount. The impact of the aerosol concentration on simulated precipitation is evaluated by varying the initial cloud condensation nuclei (CCN) number concentration in the Weather Research and Forecasting (WRF) Double-Moment 6-class (WDM6) microphysics scheme. The simulations are performed under clean, semi-polluted, and polluted conditions. Detailed analysis of the physical processes that are responsible for surface precipitation, including moisture and cloud microphysical budgets shows enhanced ice-phase processes to be the primary driver of increased surface precipitation under the semi-polluted condition. Under the polluted condition, suppressed autoconversion and the enhanced evaporation of rain cause surface precipitation to decrease. To investigate the role of environmental conditions on precipitation response under different aerosol number concentrations, a set of sensitivity experiments are conducted with a 5 % decrease in relative humidity at the initial time, relative to the base simulations. Results show ice-phase processes having small sensitivity to CCN number concentration, compared with the base simulations. Surface precipitation responds differently to CCN number concentration under the lower humidity initial condition, being greatest under the clean condition, followed by the semi-polluted and polluted conditions.

aerosol↗