At least 811 records · Page 45

Hardware-in-the-Loop Evaluation for Potential High Limit Estimation-Based PV Plant Active Control: Preprint

This paper validates the effectiveness of an Artificial Intelligence (AI)-driven PV plant control and optimization approach, namely, the Automated Learner for Intermittency Control by Extrapolation (ALICE), in empowering PV plant as a dependable grid reliability service provider. The validation is performed in a realistic laboratory controller-hardware-in-the-loop (CHIL) environment, leveraging accurate PV plant modeling and standard industrial communication protocol. Simulation results, considering both varying weather conditions and active control scenarios, demonstrate the superior performance of ALICE in improving the grid service delivery precision and reducing the over-curtailment compared to a state-of-the-art approach, i.e., reference-control grouping based approach. Such a work could help mitigate risks and provide practical guidance during the field deployment of ALICE, while establishing a standardized testing framework for evaluating various PV active control strategies.

hardware-in-the-loop↗

Multi-timescale operations of nuclear-renewable hybrid energy systems for reserve and thermal product provision

In this paper, an optimal operation strategy of a nuclear-renewable hybrid energy system (N-R HES), in conjunction with a district heating network, is developed within a comprehensive multi-timescale electricity market framework. The grid-connected N-R HES is simulated to explore the capabilities and benefits of N-R HES of providing energy products, different reserve products, and thermal products. An N-R HES optimization and control strategy is formulated to exploit the benefits from the hybrid energy system in terms of both energy and ancillary services. A case study is performed on the customized NREL-118 bus test system with high renewable penetrations, based on a multi-timescale (i.e., three-cycle) production cost model. Both day-ahead and real-time market clearing prices are determined from the market model simulation. In conclusion, the results show that the N-R HES can contribute to the reserve requirements and also meet the thermal load, thereby increasing the economic efficiency of N-R HES (with increased revenue ranging from 1.55% to 35.25% at certain cases) compared to the baseline case where reserve and thermal power exports are not optimized.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Additional Capacity Value From Synergy of Variable Renewable Energy and Energy Storage

Current capacity markets often consider capacity credits from each resource independently, irrespective of the portfolio of resources, potentially overvaluing or undervaluing the capacity contribution of variable renewable energy (VRE) and energy storage (ES) in the grid. We propose a method for calculating the standalone and integrated capacity value of an added VRE resource with existing ES resources. The difference between the integrated and standalone value is the portfolio effect. This is the additional capacity value gained by the synergy of VRE and the existing fleet. Using chronological dispatch simulations and two different reliability metrics to estimate firm capacity, we demonstrate on a small test system that the portfolio effect can be substantial.

capacity credit↗

SU-E-T-600: Patient Specific IMRT Verification Using a Phosphor-Screen Based Geometric QA System: A Preliminary Study

Purpose: Raven QA (JPLC, MD) is a unified and comprehensive quality assurance system for QA of TG-142, which use a phosphor screen, a mirror system and a camera. It is to test if this device can be used for IMRT QA dosimetry. Methods: A lung IMRT case is used deliver dose to Raven QA. Accuracy of dose distribution of 5cm slab phantom using Eclipse planning system (Varian) has been confirmed both from a Monte Carlo Simulation and from a MapCheck (SunNuclear) measurement. Geometric distortion and variation of spatial dose response are corrected after background subtraction. A pin-hole grid plate is designed and used to determine the light scatter in the Raven QA box and the spatial dose response. Optic scatter model was not applied in this preliminary study. Dose is normalized to the response of the 10×10 field and the TMR of 5cm depth was considered. Results: Time to setup the device for IMRT QA takes less than 5 minutes as other commercially available devices. It shows excellent dose linearity and dose rate independent, less than 1 %. Background signal, however, changes for different field sizes. It is believed to be due to inaccurate correction of optic scatter. Absolute gamma (5%, 5mm) passing rate was higher than 95%. Conclusion: This study proves that the Raven QA can be used for a patient specific IMRT verification. Part of this study is supported by the Maryland Industrial Partnership Grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Future Nuclear Energy Factual Status Document: Resource Document for the Workshop on Basic Research Needs for Future Nuclear Energy, July 2017

Since commercialization in the mid-1950s, nuclear power has been widely deployed and provides an important clean source of energy, primarily through the generation of electricity. There are currently 449 commercial nuclear power reactors operating in 31 countries with over 390 GWe total capacity, with 99 operating units in the United States with a total generating capacity of about 100 GWe. Nuclear power plants provide over 11% of the world’s electricity production and, as of 2016, thirteen countries rely on nuclear energy to supply at least one-quarter of their total electricity. Virtually all of that power is generated with water-cooled reactor systems. A number of advanced nuclear energy system concepts have been developed to provide improved efficiency, greater fissile fuel utilization, reduced high level waste generation, and increased margins of safety over today’s water-cooled systems. However, there are a number of technical challenges that must be addressed to enable the broad deployment of these systems from concept to the electrical grid. This Technical Document is written to provide workshop participants with an overview of the current status of a number of advanced reactor systems: Key issues for advanced nuclear energy, including coolants, materials in extremes (irradiation, coolant, and/or high temperature) and interfaces; Nuclear fuel technologies for key reactor types and limitations in testing and design; State of science and understanding for nuclear systems, including characterization, testing, and modeling and simulation tools. For each of these technical areas, this document describes the technological challenge, current state of the art for the technology, and barriers to advanced nuclear concepts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Correlation between Mixing Length and Metallicity on the Giant Branch: Implications for Ages in the Gaia Era

In the updated APOGEE- Kepler catalog, we have asteroseismic and spectroscopic data for over 3000 first ascent red giants. Given the size and accuracy of this sample, these data offer an unprecedented test of the accuracy of stellar models on the post-main-sequence. When we compare these data to theoretical predictions, we find a metallicity dependent temperature offset with a slope of around 100 K per dex in metallicity. We find that this effect is present in all model grids tested, and that theoretical uncertainties in the models, correlated spectroscopic errors, and shifts in the asteroseismic mass scale are insufficient to explain this effect. Stellar models can be brought into agreement with the data if a metallicity-dependent convective mixing length is used, with Δ α {sub ML,YREC} ∼ 0.2 per dex in metallicity, a trend inconsistent with the predictions of three-dimensional stellar convection simulations. If this effect is not taken into account, isochrone ages for red giants from the Gaia data will be off by as much as a factor of two even at modest deviations from solar metallicity ([Fe/H] = −0.5).

79 ASTRONOMY AND ASTROPHYSICS↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Release of a High Temperature Engineering Test Reactor (HTTR) Steady State Multiphysics Model to the Virtual Test Bed

In response to climate change, global governments and private industry have established a common goal of achieving net-zero emissions by 2050 \cite{osti_1865910}. This goal requires a reassessment of current energy demands and production methods. Reducing emissions at an affordable cost while maintaining grid reliability requires a nationwide collaborative effort among government and industry in the United States. Nuclear power is the leading low-carbon electricity generation method. In the past 50 years, the use of nuclear power has reduced carbon dioxide emissions by over 60 gigatons and has played a crucial role in the security of energy supply~\cite{IEA}. In the U.S., nuclear power accounts for 20\% of the electrical supply and provides energy reliably. Advanced reactors will operate at higher temperatures, operate more efficiently, utilize more energy stored within fuel, and reduce the amount of waste produced \cite{osti_1616270}. To face these challenges and goals, the U.S. Department of Energy has created an initiative to focus on the modeling and simulation tools to support future nuclear power plant design, licensing, and operations. The Virtual Test Bed (VTB)~\cite{vtb2023} was launched by the National Reactor Innovation Center (NRIC) in collaboration with the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program to support the advanced nuclear reactor community. The VTB involves teams from both Idaho National Laboratory and Argonne National Laboratory and aims to provide example models for a broad range of both current and future advanced reactor designs. A feature of the VTB is the automatic testing of these models to ensure continued functionality as simulation tools are further developed. The VTB and the advanced reactor models documented there are important resources for this initiative. This work describes the inclusion of a new model on the VTB---a High Temperature Engineering Test Reactor (HTTR) steady-state model \cite{LABOURE2023109838}.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of compound flooding in Japan using a nationwide model

For this study, a high-resolution, summit-to-sea unstructured-grid model was used to simulate two compound flooding events in different geomorphic settings in Japan: the July 2012 flood in Kumamoto city and July 2018 flood in Okayama City, both caused by a torrential rainfall during seasonal Meiyu front but otherwise exhibiting quite different compound flood characteristics. The model shows good performance in simulating flooding extent; e.g., the Hit Rate for the inundation event in 2018 exceeds 0.9. Sensitivity tests were conducted to determine the roles/significance of levee structures along major rivers in coastal regions. Our results indicate that riverine and oceanic factors as well as levees significantly contribute to the observed flooding extents, and we are able to quantify the contributions from each factor at different locations. The model has been implemented operationally as the first nationwide 3-day compound flooding forecast system for Japan.

54 ENVIRONMENTAL SCIENCES↗

Design of an advanced energy management system for microgrid control using a state machine

A state machine is proposed as the solution for an automated microgrid energy management system (EMS) to improve transient performance during transition operations. It characterizes microgrid operation by seven states that cover all the operating modes: two for steady-state operation (grid-connected and islanded), four for transition operation (preparing for disconnection, transitioning to islanding, preparing for reconnection, and transitioning to grid-connected), and one for emergency operation (black-start operation). A unique dispatch algorithm is developed for each state to achieve the control objective, and the transition function is implemented in the state machine as control logics to transition the system from one state to the next. The feasibility and effectiveness of the developed state machine is validated by simulation in MATLAB with an example microgrid, and the test results show excellent performance of the state machine to achieve the target control objective in each state and to improve the system's transient performance during transition operation.

36 MATERIALS SCIENCE↗

Fretting wear behaviors of a dual-cooled nuclear fuel rod under a simulated rod vibration

Recently, a dual-cooled fuel (i.e., annular fuel) that is compatible with current operating PWR plants has been proposed in order to realize both a considerable amount of power uprating and an increase of safety margins. As the design concept should be compatible with current operating PWR plants, however, it shows a narrow gap between the fuel rods when compared with current solid nuclear fuel arrays and needs to modify the spacer grid shapes and their positions. In this study, fretting wear tests have been performed to evaluate the wear resistance of a dual-cooled fuel by using a proposed spring and dimple of spacer grids that have a cantilever type and hemispherical shape, respectively. As a result, the wear volume of the spring specimen gradually increases as the contact condition is changed from a certain gap, just contact to positive force. However, in the dimple specimen, just contact condition shows a large wear volume. In addition, a circular rod motion at upper region of contact surface is gradually increased and its diametric size depends on the wear depth increase. Based on the test results, the fretting wear resistance of the proposed spring and dimple is analyzed by comparing the wear measurement results and rod motion in detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mixing model with multi-particle interactions for Lagrangian simulations of turbulent mixing

We report on the numerical study of the mixing volume model (MVM) for molecular diffusion in Lagrangian simulations of turbulent mixing problems. The MVM is based on the multi-particle interaction in a finite volume (mixing volume). A priori test of the MVM, based on the direct numerical simulations of planar jets, is conducted in the turbulent region and the interfacial layer between the turbulent and non-turbulent fluids. The results show that the MVM predicts well the mean effects of the molecular diffusion under various numerical and flow parameters. The number of the mixing particles should be large for predicting a value of the molecular diffusion term positively correlated to the exact value. The size of the mixing volume relative to the Kolmogorov scale η is important in the performance of the MVM. The scalar transfer across the turbulent/non-turbulent interface is well captured by the MVM especially with the small mixing volume. Furthermore, the MVM with multiple mixing particles is tested in the hybrid implicit large-eddy-simulation/Lagrangian-particle-simulation (LES–LPS) of the planar jet with the characteristic length of the mixing volume of O(100η). Despite the large mixing volume, the MVM works well and decays the scalar variance in a rate close to the reference LES. The statistics in the LPS are very robust to the number of the particles used in the simulations and the computational grid size of the LES. Both in the turbulent core region and the intermittent region, the LPS predicts a scalar field well correlated to the LES.

42 ENGINEERING↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guaranteed Phase & Topology Identification in Three Phase Distribution Grids

We present a method for joint phase identification and topology recovery in unbalanced three phase radial networks using only voltage measurements. By recovering phases and topology jointly, we utilize all three phase voltage measurements and can handle networks where some buses have a subset of three phases. Our method is theoretically justified by a novel linearized formulation of unbalanced three phase power flow and makes precisely defined and reasonable assumptions on line impedances and load statistics. We validate our method on three IEEE test networks simulated under realistic conditions in OpenDSS, comparing our performance to the state of the art. In addition to providing a new method for phase and topology recovery, our intuitively structured linearized model will provide a foundation for future work in this and other applications.

42 ENGINEERING↗

Development of a hardware-in-the-loop testbed for laboratory performance verification of flexible building equipment in typical commercial buildings

The goals of reducing energy costs, shifting electricity peaks, increasing the use of renewable energy, and enhancing the stability of the electric grid can be met in part by fully exploiting the energy flexibility potential of buildings and building equipment. The development of strategies that exploit these flexibilities could be facilitated by publicly available high-resolution datasets illustrating how control of HVAC systems in commercial buildings can be used in different climate zones to shape the energy use profile of a building for grid needs. This article presents the development and integration of a Hardware-In-the-Loop Flexible load Testbed (HILFT) that integrates physical HVAC systems with a simulated building model and simulated occupants with the goal of generating datasets to verify load flexibility of typical commercial buildings. Compared to simulation-only experiments, the hardware-in-the-loop approach captures the dynamics of the physical systems while also allowing efficient testing of various boundary conditions. The HILFT integration in this article is achieved through the co-simulation among various software environments including LabVIEW, MATLAB, and EnergyPlus. Although theoretically viable, such integration has encountered many real-world challenges, such as: 1) how to design the overall data infrastructure to ensure effective, robust, and efficient integration; 2) how to avoid closed-loop hunting between simulated and emulated variables; 3) how to quantify system response times and minimize system delays; and 4) how to assess the overall integration quality. Lessons-learned using the examples of an AHU-VAV system, an air-source heat pump system, and a water-source heat pump system are presented.

Chen, zhelun↗

The Increasingly Complex Challenge of Gas Hydrate Reservoir Simulation

Gas hydrate reservoir simulation is a complex endeavor. Reliable simulation capability will allow the proper design of field tests and the interpretation of field test data that are necessary to advance the understanding of the response of gas hydrate reservoirs to production activities. Increasing appreciation of the complexity of gas hydrate reservoirs, as well as continued uncertainty in key petrophysical parameters, requires great care in the design of simulation studies. This report outlines select emerging issues that greatly impact the relevance of numerical simulation resulting, including reservoir heterogeneity, geomechanics, log and core data interpretation, grid size, and others.

Boswell, Ray↗

A generic microgrid controller: Concept, testing, and insights

Microgrids have garnered attention in recent years as a way to increase the reliability of the grid, increase the reliability of electricity service to customers, adapt to an increasing percentage of intermittent renewable generation, and serve both customer critical loads and the needs of adjacent communities in the case of emergencies such as natural disasters. One barrier to microgrids is the historic cost and lack of standardization associated with microgrid controllers. To reduce this cost and address standardization, specifications for a Generic Microgrid Controller (GMC) were developed with the goal to facilitate the design and ease of adaptation of microgrid controllers to various microgrids of different sizes and with different resources. A GMC must address two core functions, Transition and Dispatch, as well as several optional higher level functions such as economic dispatch, and renewable and load forecasting. The GMC specifications were demonstrated and evaluated using a commercial simulation platform for two different microgrids, a 20MW-Class community microgrid and a 10MW-Class medical center microgrid. For each microgrid, the GMC was tested in hardware-in-the-loop (HIL) using an OPAL-RT real-time digital simulator, and the two core functions were assessed. The results established that (1) the GMC is successful in seamlessly transitioning the microgrids to and from an islanded mode, (2) a load/generation mismatch at the time of separation depends on the microgrid configuration and must be lower than a specific value determined by simulation testing, and (3) the GMC Dispatch Function response is acceptable in maintaining, in the islanded mode, 60Hz for a range of load changes.

24 POWER TRANSMISSION AND DISTRIBUTION↗