Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnected systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

System-Level Efficiency Study of Modular DC/DC and Fuel Cell Stack Series–Parallel Configurations

This paper presents a system-level efficiency study of modular DC/DC converter and fuel cell stack configurations under series, parallel, and series–parallel connections. The investigation considers selected DC/DC converter topologies, including isolated and non-isolated architectures, boost, non-inverting buck-boost, and resonant converters, integrated with commercially available fuel cell stacks, including the Accelera FCE150, Ballard FCgen-HPS, and Toyota TFCM2. DC/DC converter modules are evaluated in modular configurations rated at 60 kW and 90 kW and two distinct output voltage ranges, specifically 580–730V and 780–930V, examining how different interconnection schemes impact overall system efficiency. The converters are evaluated under full load (100%), partial load (66%), and light load (33%) conditions, providing a comprehensive assessment of efficiency and operational characteristics across varying power demands. Approximately two-thousand efficiency data points are obtained from laboratory prototype–level component measurements and validated design evaluations across multiple converter topologies, modular configurations, voltage ranges, and load conditions, providing a robust dataset for comparative system-level efficiency analysis. The results highlight the effects of modularity and topology selection on system-level efficiency, offering a “playbook” framework for designers to select appropriate DC/DC converter arrangements and fuel cell stack connections for series, parallel, or hybrid configurations based on efficiency considerations.

DC/DC↗

Great Lakes O shore Wind Project: Utility and Regional Integration Study

This project aims to identify transmission system upgrades needed to facilitate offshore wind projects as well as operational impacts of offshore generation on operation of the regional transmission system in the Great Lakes region. A simulation model of the US Eastern Interconnection was used as the test system as a case study for investigating the impact of the integration of a 1000MW offshore wind farm operating in Lake Erie into FirstEnergy/PJM service territory. The findings of this research provide recommendations on offshore wind integration scenarios, the locations of points of interconnection, wind profile modeling and simulation, and computational methods to quantify performance, along with operating changes and equipment upgrades needed to mitigate system performance issues introduced by an offshore wind project.

17 WIND ENERGY↗

An enhanced SOCP-based method for feeder load balancing using the multi-terminal soft open point in active distribution networks

The integration of distributed generators (DGs) exacerbates the feeder power flow fluctuation and load unbalanced condition in active distribution networks (ADNs). The unbalanced feeder load causes inefficient use of network assets and network congestion during system operation. The flexible interconnection based on the multi-terminal soft open point (SOP) significantly benefits the operation of ADNs. The multi-terminal SOP, which is a controllable power electronic device installed to replace the normally open point, provides accurate active and reactive power flow control to enable the flexible connection of feeders. An enhanced SOCP-based method for feeder load balancing using the multi-terminal SOP is proposed in this paper. Furthermore, by regulating the operation of the multi-terminal SOP, the proposed method can mitigate the unbalanced condition of feeder load and simultaneously reduce the power losses of ADNs. Then, the original non-convex model is converted into a second-order cone programming (SOCP) model using convex relaxation. In order to tighten the SOCP relaxation and improve the computation efficiency, an enhanced SOCP-based approach is developed to solve the proposed model. Finally, case studies are performed on the modified IEEE 33-node system to verify the effectiveness and efficiency of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Instability Problems in North American Interconnections

Alternating current power transmission and distribution systems in the United States operate at a nominal (target) frequency of 60 Hz. Large deviations from this frequency can cause network instability, and even small deviations can adversely affect sensitive end-use devices. Frequency deviations commonly result from a mismatch between energy supply and demand on a power network. If supply is insufficient to meet demand, the system frequency will decrease; if supply exceeds demand, frequency will increase. Over 100 balancing authorities within four electrical interconnections in North America manage power flows so that frequency will remain stable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Dynamic analysis of flexible multibody structures

A system composed of several interconnected elastic components that may experience large angular motion relative to each other during operation is referred to as a flexible multibody structure. Several formulations were proposed for the determination of the dynamic response of controlled flexible multibody structures. In general, these formulations consist of superposing elastic deformations of the component body onto the large rigid body motion of the component. It was shown that this particular methodology for combining linear structural deformations with nonlinear kinematics can lead to erroneous response predictions when either the beam member is very flexible or the rotational speed is high. In addition, previous formulations introduce constraint equations to define the interrelations among system components. This approach increases the number of equations that must be solved, and may result in contraint violation when numerical error accumulates during the integration process. In order to overcome the difficulties, a new approach was suggested. The approach is essentially a finite element formulation which takes advantage of the fact that many multibody structures are joint dominated. The Large Angle Transient Dynamic Analysis (LATDYN) program for clarity of documentation, ease of use, user friendliness, modeling generality, and accuracy of results was evaluated. This required gaining a working familiarity with the code and performing several case studies.

Hernried, Alan G.↗

North American SynchroPhasor Initiative – An Update of Progress

In 2007, the U.S. Department of Energy (DOE) and the North American Electric Reliability Corporation (NERC), along with involved electric utility companies and other organizations, formed the North American SynchroPhasor Initiative (NASPI). This effort combines the previous Eastern Interconnection Phasor Project (EIPP) and various activities associated with Wide Area Measurement System (WAMS) research, development, and deployment activities that have been underway in the North American electric power system for a number of years as the primary focal point for continued DOE and NERC support and facilitation. This paper provides an update on this activity, with current status and research work currently underway

CERTS↗

Performance evaluation of the Engineering Analysis and Data Systems (EADS) 2

The Engineering Analysis and Data System (EADS)II (1) was installed in March 1993 to provide high performance computing for science and engineering at Marshall Space Flight Center (MSFC). EADS II increased the computing capabilities over the existing EADS facility in the areas of throughput and mass storage. EADS II includes a Vector Processor Compute System (VPCS), a Virtual Memory Compute System (CFS), a Common Output System (COS), as well as Image Processing Station, Mini Super Computers, and Intelligent Workstations. These facilities are interconnected by a sophisticated network system. This work considers only the performance of the VPCS and the CFS. The VPCS is a Cray YMP. The CFS is implemented on an RS 6000 using the UniTree Mass Storage System. To better meet the science and engineering computing requirements, EADS II must be monitored, its performance analyzed, and appropriate modifications for performance improvement made. Implementing this approach requires tool(s) to assist in performance monitoring and analysis. In Spring 1994, PerfStat 2.0 was purchased to meet these needs for the VPCS and the CFS. PerfStat(2) is a set of tools that can be used to analyze both historical and real-time performance data. Its flexible design allows significant user customization. The user identifies what data is collected, how it is classified, and how it is displayed for evaluation. Both graphical and tabular displays are supported. The capability of the PerfStat tool was evaluated, appropriate modifications to EADS II to optimize throughput and enhance productivity were suggested and implemented, and the effects of these modifications on the systems performance were observed. In this paper, the PerfStat tool is described, then its use with EADS II is outlined briefly. Next, the evaluation of the VPCS, as well as the modifications made to the system are described. Finally, conclusions are drawn and recommendations for future worked are outlined.

Debrunner, Linda S.↗

Active power control of solar PV generation for large interconnection frequency regulation and oscillation damping

Because of zero greenhouse gas emission and decreased manufacture cost, solar photovoltaic (PV) generation is expected to account for a significant portion of future power grid generation portfolio. Because it is indirectly connected to the power grid via power electronic devices, solar PV generation system is fully decoupled from the power grid, which will influence the interconnected power grid dynamic characteristics as a result. In this study, the impact of solar PV penetration on large interconnected power system frequency response and inter-area oscillation is evaluated, taking the United States Eastern Interconnection (EI) as an example. Furthermore, based on the constructed solar PV electrical control model with additional active power control loops, the potential contributions of solar PV generation to power system frequency regulation and oscillation damping are examined. The advantages of solar PV frequency support over that of wind generator are also discussed. Finally, simulation results demonstrate that solar PV generations can effectively work as ‘actuators’ in alleviating the negative impacts they bring about.

14 SOLAR ENERGY↗

Emergent flat band and topological Kondo semimetal driven by orbital-selective correlations

Flat electronic bands are expected to show proportionally enhanced electron correlations, which may generate a plethora of novel quantum phases and unusual low-energy excitations. They are increasingly being pursued in d-electron-based systems with crystalline lattices that feature destructive electronic interference, where they are often topological. Such flat bands, though, are generically located far away from the Fermi energy, which limits their capacity to partake in the low-energy physics. Here we show that electron correlations produce emergent flat bands that are pinned to the Fermi energy. We demonstrate this effect within a Hubbard model, in the regime described by Wannier orbitals where an effective Kondo description arises through orbital-selective Mott correlations. Moreover, the correlation effect cooperates with symmetry constraints to produce a topological Kondo semimetal. Our results motivate a novel design principle for Weyl Kondo semimetals in a new setting, viz.d-electron-based materials on suitable crystal lattices, and uncover interconnections among seemingly disparate systems that may inspire fresh understandings and realizations of correlated topological effects in quantum materials and beyond.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessing and Promoting Functional Resilience in Flight Crews During Exploration Missions

NASA plans to send humans to Mars in about 20 years. The NASA Human Research Program supports research to mitigate the major risks to human health and performance on extended missions. However, there will undoubtedly be unforeseen events on any mission of this nature - thus mitigation of known risks alone is not sufficient to ensure optimal crew health and performance. Research should be directed not only to mitigating known risks, but also to providing crews with the tools to assess and enhance resilience, as a group and individually. We can draw on ideas from complexity theory and network theory to assess crew and individual resilience. The entire crew or the individual crewmember can be viewed as a complex system that is composed of subsystems (individual crewmembers or physiological subsystems), and the interactions between subsystems are of crucial importance for overall health and performance. An understanding of the structure of the interactions can provide important information even in the absence of complete information on the component subsystems. This is critical in human spaceflight, since insufficient flight opportunities exist to elucidate the details of each subsystem. Enabled by recent advances in noninvasive measurement of physiological and behavioral parameters, subsystem monitoring can be implemented within a mission and also during preflight training to establish baseline values and ranges. Coupled with appropriate mathematical modeling, this can provide real-time assessment of health and function, and detect early indications of imminent breakdown. Since the interconnected web of physiological systems (and crewmembers) can be interpreted as a network in mathematical terms, we can draw on recent work that relates the structure of such networks to their resilience (ability to self-organize in the face of perturbation). There are many parameters and interactions to choose from. Normal variability is an established characteristic of a healthy physiological response. Healthy coupling has been investigated less extensively, but there are cases in which too tight or too loose coupling can be problematic. This might be in inter-individual behaviors, such as sleep cycles, coordination of work and meal times, and coupled motions during communication. Less apparent are couplings of physiological systems, nevertheless examples abound of coupled systems which might be monitored: cardio-respiratory rhythms; circadian rhythms, body temperature, and sleep; stress markers and cognition, sleep, and performance; profiles of biochemical markers related to immune function and nutritional status; sensorimotor aspects such as motion sickness, ataxia, reaction time, and manual control. Tools for resilience are then the means to measure and analyze these parameters, incorporate them into appropriate models of normal variability and interconnectedness, and recognize when parameters or their couplings are outside of normal limits. What to do when a problem is identified depends on its nature. Changes can be made to crew procedures, work pacing, interpersonal interactions, sleep cycles, meal timing and content, as guided by the model. Use and continued development of these methods could not only provide tools for resilience, but also meaningful autonomous work for the crew on an extended flight.

Shelhamer, Mark↗

Damage Spreading in Spatial and Small-world Random Boolean Networks

The study of the response of complex dynamical social, biological, or technological networks to external perturbations has numerous applications. Random Boolean Networks (RBNs) are commonly used a simple generic model for certain dynamics of complex systems. Traditionally, RBNs are interconnected randomly and without considering any spatial extension and arrangement of the links and nodes. However, most real-world networks are spatially extended and arranged with regular, power-law, small-world, or other non-random connections. Here we explore the RBN network topology between extreme local connections, random small-world, and pure random networks, and study the damage spreading with small perturbations. We find that spatially local connections change the scaling of the relevant component at very low connectivities ($\bar{K} \ll 1$) and that the critical connectivity of stability $K_s$ changes compared to random networks. At higher $\bar{K}$, this scaling remains unchanged. We also show that the relevant component of spatially local networks scales with a power-law as the system size N increases, but with a different exponent for local and small-world networks. The scaling behaviors are obtained by finite-size scaling. We further investigate the wiring cost of the networks. From an engineering perspective, our new findings provide the key design trade-offs between damage spreading (robustness), the network's wiring cost, and the network's communication characteristics.

Lu, Qiming↗

A Modular Multilevel Converter with Power Mismatch Control for Grid-Connected Photovoltaic Systems

A modular multilevel power converter configuration for grid connected photovoltaic (PV) systems is proposed. The converter configuration replaces the conventional bulky line frequency transformer with several high frequency transformers, potentially reducing the balance of systems cost of PV systems. The front-end converter for each port is a neutral-point diode clamped (NPC) multi-level dc-dc dual-active bridge (ML-DAB) which allows maximum power point tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is a NPC inverter. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e., 13.8 kV). The cascaded NPC (CNPC) inverters have the inherent advantage of using lower rated devices, smaller filters and low total harmonic distortion required for PV grid interconnection. The proposed converter system is modular, scalable, and serviceable with zero downtime with lower foot print and lower overall cost. A novel voltage balance control at each module based on power mismatch among N-ports, have been presented and verified in simulation. Analysis and simulation results are presented for the N-port converter. The converter performance has also been verified on a hardware prototype.

14 SOLAR ENERGY↗

Exploring DataVortex Systems for Irregular Applications

Emerging applications for data analytics and knowledge discovery typically have irregular or unpredictable communication patterns that do not scale well on parallel systems designed for traditional bulk-synchronous HPC applications. New network architectures that focus on minimizing (short) message latencies, rather than maximizing (large) transfer bandwidths, are emerging as possible alternatives to better support those applications with irregular communication patterns. We explore a system based upon one such novel network architecture, the Data Vortex interconnection network, and examine how this system performs by running benchmark code written for the Data Vortex network, as well as a reference MPI-over- Infiniband implementation, on the same cluster.

Data Vortex, High-Performance Computing, Networkin↗

Generic solar photovoltaic system dynamic simulation model specification

This document is intended to serve as a specification for generic solar photovoltaic (PV) system positive-sequence dynamic models to be implemented by software developers and approved by the WECC MVWG for use in bulk system dynamic simulations in accordance with NERC MOD standards. Two specific dynamic models are included in the scope of this document. The first, a Central Station PV System model, is intended to capture the most important dynamic characteristics of large scale (> 10 MW) PV systems with a central Point of Interconnection (POI) at the transmission level. The second, a Distributed PV System model, is intended to represent an aggregation of smaller, distribution-connected systems that comprise a portion of a composite load that might be modeled at a transmission load bus.

14 SOLAR ENERGY↗