Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Assessment of the displacement field along a surface crack in a flat plate using optical techniques

Structural components may contain cracks, and for these components a crack tip represents a highly singular stress. The evaluation of the associated strain gradient is difficult to achieve with experimental discrete methods. An efficient alternative are the optical techniques which are non-contact, and so delivering continuous information of the displacement fields and associated derivatives for strain evaluation. This paper describes some experimental methods to fully characterize the displacement field near a crack tip existing in flat plates. Three optical field techniques based on image analysis were used in the present work; respectively, Electronic Speckle Pattern Interferometry, Moiré Interferometry, and Digital Image Correlation. These methods allow different resolutions which can be adjusted according to the expected strain gradient. While the first method depends on the laser wavelength and position of the illumination sources, the second depends on the grating pitch and the last on the surface texture or painted speckle. Algorithms to derivate and filtering the displacement field are developed to compute the strain field and will be used for further works.

36 MATERIALS SCIENCE↗

XFEL imaging techniques for high energy density and inertial fusion energy research at HED-HiBEF

The imaging platform developed at the High Energy Density-Helmholtz International Beamline for Extreme Fields (HED-HiBEF) instrument at the European X-ray Free Electron Laser (XFEL) and its applications to HED and fusion related research are presented. The platform combines the XFEL beam with the high-intensity short-pulse laser ReLaX and the high-energy nanosecond-pulse laser DiPOLE-100X. The spatial resolution is better than 500 nm and the temporal resolution of the order of 50 fs. The influence of the XFEL source in the x-ray imaging method is discussed. Free-propagation x-ray phase contrast imaging and Talbot-Lau imaging setups are shown. We show examples of blast waves and converging cylindrical shocks in aluminum, resonant absorption measurements of specific charged states in copper with ReLaX and planar shocks in polystyrene material generated by DiPOLE-100X. For the first time, we show the application of Talbot-Lau interferometry to convergent cylindrical shocks as well as resonant absorption processes. We also discuss the possibilities introduced by combining this imaging platform with a kJ-class laser.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Beauty and Limitations of 10 Micron Heterodyne Interferometry (ISI)

Until recently, heterodyne interferometry at 10 microns has been the only successful technique for stellar interferometry in the very difficult atmospheric window from 9-12 microns. For most of its operational lifetime the U.C. Berkeley Infrared Spatial Interferometer was a single-baseline two telescope (1.65 m aperture) system using CO2 lasers as local oscillators. This instrument was designed and constructed from 1983-1988, and first fringes were obtained at Mt. Wilson in June 1988. During the past few years, a third telescope was constructed and just recently the first closure phases were obtained at 11.15 microns. We discuss the history, physics and technology of heterodyne interferometry in the mid-infrared, and some key astronomical results that have come from this unique instrument.

Danchi, William C.↗

Wavelength independent interferometer

A polychromatic interferometer utilizing a plurality of parabolic reflective surfaces to properly preserve the fidelity of light wavefronts irrespective of their wavelengths as they pass through the instrument is disclosed. A preferred embodiment of the invention utilizes an optical train which comprises three off-axis parabolas arranged in conjunction with a beam-splitter and a reference mirror to form a Twyman-Green interferometer. An illumination subsystem is provided and comprises a pair of lasers at different preselected wavelengths in the visible spectrum. The output light of the two lasers is coaxially combined by means of a plurality of reflectors and a grating beam combiner to form a single light source at the focal point of the first parabolic reflection surface which acts as a beam collimator for the rest of the optical train. By using visible light having two distinct wavelengths, the present invention provides a long equivalent wavelength interferogram which operates at visible light wherein the effective wavelength is equal to the product of the wavelengths of the two laser sources divided by their difference in wavelength. As a result, the invention provides the advantages of what amounts to long wavelength interferometry but without incurring the disadvantage of the negligible reflection coefficient of the human eye to long wavelength frequencies which would otherwise defeat any attempt to form an interferogram at that low frequency using only one light source.

Hochberg, Eric B.↗

Investigation of wire-array Z-pinches by laser probing diagnostics

Laser diagnostics provides powerful tools for the investigation of dense Z-pinches. In this paper, wire-array Z-pinches are investigated at the 1 MA Zebra generator using laser diagnostics at different wavelengths coupled with x-ray diagnostics. Plasma dynamics during the ablation, implosion, and stagnation stages are observed by multiframe diagnostics. Cascading and nonprecursor implosions are studied in wire arrays. Ultraviolet diagnostics allows deep penetration into the Z-pinch plasma at stagnation. End-on probing reveals the complicated structure of the precursor. Strong magnetohydrodynamic instabilities are found in a dense pinch hidden in the trailing plasma. Small-scale instabilities are seen in the Z-pinch plasma with micrometer resolution. Probing of the pinch from four directions shows asymmetrical trailing plasma in some configurations of wire arrays. Faraday rotation diagnostics reveals the magnetic fields and the current distribution in the plasma of the precursor and Z-pinch. Redistribution of current in the trailing plasma is seen during kink and sausage instabilities in the stagnation stage. The formation of micropinches and hot spots in the Z-pinch is analyzed with coupled laser and x-ray diagnostics. Different laser diagnostics allow the study of Z-pinch plasmas in all stages, including fast dynamics and instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating manual holographic interferometry system for 2 x 2 foot transonic wind tunnel

A holographic interferometer system was installed in a 2X2 foot transonic wind tunnel. The system incorporates a modern, 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described as well as the integration of the system into the existing Schieren system. A two plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.

Craig, J. E.↗

Imprinting high-gradient topographical structures onto optical surfaces using magnetorheological finishing: Manufacturing corrective optical elements for high-power laser applications

Corrective optical elements form an important part of high-precision optical systems. We have developed a method to manufacture high-gradient corrective optical elements for high-power laser systems using deterministic magnetorheological finishing (MRF) imprinting technology. Several process factors need to be considered for polishing ultraprecise topographical structures onto optical surfaces using MRF. They include proper selection of MRF removal function and wheel sizes, detailed MRF tool and interferometry alignment, and optimized MRF polishing schedules. Dependable interferometry also is a key factor in high-gradient component manufacture. A wavefront attenuating cell, which enables reliable measurement of gradients beyond what is attainable using conventional interferometry, is discussed. The results of MRF imprinting a 23 μm deep structure containing gradients over 1.6 μm / mm onto a fused-silica window are presented as an example of the technique’s capabilities. As a result, this high-gradient element serves as a thermal correction plate in the high-repetition-rate advanced petawatt laser system currently being built at Lawrence Livermore National Laboratory.

42 ENGINEERING↗

Reconstruction of a three-dimensional, transonic rotor flow field from holographic interferogram data

Holographic interferometry and computerized aided tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2 ft dia view field near the model rotor blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting the fringe order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in several planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three dimensional transonic rotor flow studies.

Kittleson, John K.↗

Interferometric data for a shock-wave/boundary-layer interaction

An experimental study of the axisymmetric shock-wave / boundary-layer strong interaction flow generated in the vicinity of a cylinder-cone intersection was conducted. The study data are useful in the documentation and understanding of compressible turbulent strong interaction flows, and are part of a more general effort to improve turbulence modeling for compressible two- and three-dimensional strong viscous/inviscid interactions. The nominal free stream Mach number was 2.85. Tunnel total pressures of 1.7 and 3.4 atm provided Reynolds number values of 18 x 10(6) and 36 x 10(6) based on model length. Three cone angles were studied giving negligible, incipient, and large scale flow separation. The initial cylinder boundary layer upstream of the interaction had a thickness of 1.0 cm. The subsonic layer of the cylinder boundary layer was quite thin, and in all cases, the shock wave penetrated a significant portion of the boundary layer. Owing to the thickness of the cylinder boundary layer, considerable structural detail was resolved for the three shock-wave / boundary-layer interaction cases considered. The primary emphasis was on the application of the holographic interferometry technique. The density field was deduced from an interferometric analysis based on the Able transform. Supporting data were obtained using a 2-D laser velocimeter, as well as mean wall pressure and oil flow measurements. The attached flow case was observed to be steady, while the separated cases exhibited shock unsteadiness. Comparisons with Navier-Stokes computations using a two-equation turbulence model are presented.

Dunagan, Stephen E.↗

Development and implementation of an aerodynamic holographic interferometry system

An aerodynamic holographic interferometry system has been developed and adapted for use with an existing supersonic wind tunnel. The basis for the system is briefly discussed, and the flow investigation for which the system was developed is outlined. The system is described, including detailed equipment schematics and cost figures. Some details and guidance are given with regard to experience in reducing the interferometry fringe data via the Abel transformation to obtain density fields and, in turn, velocity fields. Finally, representative results are shown together with complementary laser velocimetry measurements and Navier-Stokes computations.

Miles, John B.↗

Measurement of Rotorcraft Blade Deformation using Projection Moire Interferometry

Projection Moire Interferometry (PMI) has been used to obtain near instantaneous, quantitative blade deformation measurements of a generic rotorcraft model at several test conditions. These laser-based measurements provide quantitative, whole field, dynamic blade deformation profiles conditionally sampled as a function of rotor azimuth. The instantaneous nature of the measurements permits computation of the mean and unsteady blade deformation, blade bending, and twist. The PMI method is presented, and the image processing steps required to obtain quantitative deformation profiles from PMI interferograms are described. Experimental results are provided which show blade bending, twist, and unsteady motion. This initial proof-of-concept test has demonstrated the capability of PMI to acquire accurate, full field rotorcraft blade deformation data.

Fleming, Gary A.↗

Design considerations and validation of the MSTAR absolute metrology system

Absolute metrology measures the actual distance between two optical fiducials. A number of methods have been employed, including pulsed time-of-flight, intensity-modulated optical beam, and two-color interferometry. The rms accuracy is currently limited to -5 microns. Resolving the integer number of wavelengths requires a 1-sigma range accuracy of -0.1 microns. Closing this gap has a large pay-off the range (length measurement) accuracy can be increased substantially using the unambiguous optical phase. The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. In this paper, we present recent experiments that use dispersed white light interferometry to independently validate the zero-point of the system. We also describe progress towards reducing the size of optics, and stabilizing the laser wavelength for operation over larger target ranges. MSTAR is a general-purpose tool for conveniently measuring length with much greater accuracy than was previously possible, and has a wide range of possible applications.

Jeganathan, Muthu↗

Insight into the chemistry of TNT during shock compression through ultrafast absorption spectroscopies

Thin films of trinitrotoluene (TNT) were shock compressed using the ultrafast laser shock apparatus at Los Alamos National Laboratory. Visible (VIS) and mid-infrared (MIR) transient absorption spectroscopies were simultaneously performed to probe for electronic and vibrational changes during shock compression of TNT. Additionally, three shock pressures (16 GPa, 33 GPa, and 45 GPa) were selected to observe no reaction, incipient reaction, and strongly developed reactions for TNT within the experimental time scale of <250 ps. Negligible absorption changes in MIR or VIS absorptions were observed at 16 GPa. At 33 GPa, MIR absorptions in the 3000 cm -1 –4000 cm -1 range were observed to increase during the shock and continue to increase during the rarefaction, in contrast to the VIS absorption measurements, which increased during the shock and almost fully recovered during rarefaction. At 45 GPa, both VIS and MIR absorptions were strong and irreversible. The intense and spectrally broad MIR absorptions were attributed to short lived intermediates with strong, spectrally broad absorptions that dominate the spectral response. The MIR and VIS absorption changes observed at 33 GPa and 45 GPa were credited to shock induced chemistry, most likely including the formation of a very broad hydrogenic stretch feature. The results from these experiments are consistent with the chemical mechanisms that include O–H or N–H formation such as CH 3 oxidation or C–N homolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Imaging of Laser Melted SS316 Test Objects with Spatially Resolved Small Angle Neutron Scattering

A novel neutron far field interferometer is explored for sub-micron porosity detection in laser sintered stainless steel alloy 316 (SS316) test objects. The results shown are images and volumes of the first quantitative neutron dark-field tomography at various autocorrelation lengths, ξ . In this preliminary work, the beam defining slits were adjusted to an uncalibrated opening of 0.5 mm horizontal and 5 cm vertical; the images are blurred along the vertical direction. In spite of the blurred attenuation images, the dark-field images reveal structural information at the micron-scale. The topics explored include: the accessible size range of defects, potentially 338 nm to 4.5 μ m, that can be imaged with the small angle scattering images; the spatial resolution of the attenuation image; the maximum sample dimensions compatible with interferometry optics and neutron attenuation; the procedure for reduction of the raw interferogram images into attenuation, differential phase contrast, and small angle scattering (dark-field) images; and the role of neutron far field interferometry in additive manufacturing to assess sub-micron porosity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current polarity effects on laboratory plasma jets

Plasma jets produced by a pulsed power machine were investigated using Thomson scattering and other diagnostics in order to make detailed comparisons to simulations. These jets were produced from a 15 μm thick disc of Al foil on a 1.2 MA, 100 ns rise time, pulsed power machine. Experiments were performed with both a radially inward and a radially outward current ow in the Al foil to investigate the effects of voltage polarity in the experiments and determine how extended magnetohydrodynamic (XMHD) effects, such as the Hall effect, change the formation of the jet. We recorded Thomson scattering spectra with a low enough laser energy to not perturb the plasma, while providing a high enough signal to noise ratio to resolve the scattered features. This enabled the measurement of the electron temperature in the jet region of the plasma, 15.5±4 eV for both current polarities. Jets with a radially outward current ow were heated more from inverse bremsstrahlung when 10 J of laser energy was used, implying that these jets are denser than the ones with a radially inward current. This higher density was con rmed by interferometry measurements. Experimental results were compared with XMHD computer simulations, which predicted electron temperatures 1.5 to 3 σ above those measured, and significantly higher density than experiments in both polarities. In this paper, possible sources of this discrepancy are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of a 3-dimensional transonic rotor flow field from holographic interferogram data

Holographic interferometry and computer-assisted tomography (CAT) are used to determine the transonic velocity field of a model rotor blade in hover. A pulsed ruby laser recorded 40 interferograms with a 2-ft-diam view field near the model rotor-blade tip operating at a tip Mach number of 0.90. After digitizing the interferograms and extracting fringe-order functions, the data are transferred to a CAT code. The CAT code then calculates the perturbation velocity in seeral planes above the blade surface. The values from the holography-CAT method compare favorably with previously obtained numerical computations in most locations near the blade tip. The results demonstrate the technique's potential for three-dimensional transonic rotor flow studies.

Yu, Y. H.↗