Exact Light-Cone Wavefunction Representation of Matrix Elements of Electroweak Currents
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A modular, micro-scale, optical array and biodetection device for quantifying fluorescence intensities of a plurality of substantially separated, and dimensionally uniform elements of a bioarray that are located at known positions on a plain support includes a light guide that directs bioarray illumination light from a respective light source to opposing sides of the plain support. An optical module collecting light individually from the bioarray elements includes an optical member, a filter, and a sensor, such as a CCD chip. The optical member collects and transfers emitted light from the bioarray elements via the filter to the sensor. The filter transfers light from the elements having a predefined wavelength spectrum and blocks light outside the predefined wavelength spectrum. The sensor receives transferred light from the elements and produces a signal corresponding to respective elements of the bioarray.
NETL is leading a research effort to investigate, characterize, and extract rare earth elements (REE) from coal and coal by-products, including coal ash. Characterization of geologic core samples, coal mine wastes, and coal ash has led to interesting findings on the mode of occurrence and fate of rare earth minerals, such as monazite, in coal-based materials. Mineral associations and elemental distributions have been investigated and results indicate that Th is associated with light rare earth elements (LREE), possibly as monazite, and Zr is associated with heavy rare earth elements (HREE), possibly as zircon. Preliminary extractions of REE from coal ash using 2M hydrochloric acid (HCl) and sodium hydroxide (NaOH) hydrothermal pretreatment have been investigated. Sodium hydroxide solution pretreatment followed by an acid digestion was shown to increase extraction of REE to nearly 90% for coal ash.
A tube fluid flow rate meter consists of a reservoir divided by flexible diaphragm into two separate isolated compartments. The incoming and outgoing tubes open into the compartments. The orifice is sized to allow maximum tube fluid flow. Opposing compression springs are secured within the two compartments on opposite sides of the orifice to maintain orifice position when the tube fluid pressure is zero. A tapered element is centered in, and extends through the orifice into the compartment, leaving an annular opening between the element and the perimeter of the oriface. The size varies as the diaphragm flexes with changes in the tube fluid pressure to change the fluid flow through the opening. The light source directs light upon the element which in turn scatters the light through the opening into the compartment. The light detector in the compartment senses the scattered light to generate a signal indicating the amount of fluid.
A family of physical correction filters is described. Each filter is designed to correct image content of a photographed scene of limited resolution and includes a first filter element with a pinhole through which light passes to a differential amplifier. A second filter element through which light passes through one or more openings, whose geometric configuration is a function of the cause of the resolution loss included. The light, passing through the second filter element, is also supplied to the differential amplifier whose output is used to activate an optical display or recorder to reproduce a photograph or display of the scene in the original photograph or display of the scene in the original photograph with resolution which is significantly greater than that characterizing the original photograph.
Core-collapse supernovae eject huge amount of flux of energetic neutrinos. We studied the explosive nucleosyn-thesis in supernovae and found that several isotopes {sup 7}Li, {sup 11}B, {sup 92}Nb, {sup 138}La and {sup 180}Ta as well as r-process nuclei are affected by the neutrino interactions. The abundance of these isotopes therefore depends strongly on the neutrino flavor oscillation due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. We discuss first how to determine the neutrino temperatures in order to explain the observed solar system abundances of these isotopes, combined with Galactic chemical evolution of the light nuclei and the heavy r-process elements. We then study the effects of neutrino oscillation on their abundances, and propose a novel method to determine the still unknown neutrino oscillation parameters, mass hierarchy and θ{sub 13}, simultaneously. There is recent evidence that SiC X grains from the Murchison meteorite may contain supernova-produced light elements {sup 11}B and {sup 7}Li encapsulated in the presolar grains. Combining the recent experimental constraints on θ{sub 13}, we show that our method sug-gests at a marginal preference for an inverted neutrino mass hierarchy. Finally, we discuss supernova relic neutrinos that may indicate the softness of the equation of state (EoS) of nuclear matter as well as adiabatic conditions of the neutrino oscillation.
An experimental study of the partitioning of Pu and Sm between diopside/liquid and whitlockite/liquid supports the hypothesis that Pu behaves as a light rare earth element during igneous processes in reducing environments. D-Pu/D-Sm is found to be about 2 for both diopsidic pyroxene and whitlockite, and the amount of fractionation would be decreased further if Pu were compared to Ce or Nd. Data indicate that temperature, rather than melt composition, is the most important control on elemental partitioning, and that P2O5 in aluminosilicate melts serves as a complexing agent for the actinides and lanthanides.
The glioblastoma (GBM) is characterized by a short median survival and an almost 100% tumor related mortality. GBM cells exhibit highly invasive behavior whose mechanisms are not yet fully understood. The present study explores application of X-ray and visible light microscopy to display the elemental and structural images of cells from 3 patient derived GMB samples and an established GMB cell line. Slight differences in elemental concentrations, in actin cytoskeleton organization and cell morphology were noted between all cells types by X-ray fluorescence and full field soft X-ray microscopy, as well as the Structured Illumination Super-resolution Microscope (SIM). Different sample preparation approaches were used to match each imaging technique. While preparation for SIM included cell fixation and staining, intact frozen hydrated cells were used for the trace element imaging by hard X-ray fluorescence and exploration of the structural features by soft X-ray absorption tomography. In conclusion, each technique documented differences between samples with regard to morphology and elemental composition and underscored the importance of use of multiple patient derived samples for detailed GBM study.
This paper is concerned with the application of optics to digital computing. A Hughes liquid crystal light valve is used as an active optical element where a weak light beam can control a strong light beam with either a positive or negative gain characteristic. With this device as the central element the ability to produce bistable states from which different types of flip-flop can be implemented is demonstrated. In this paper, some general comments are first presented on digital computing as applied to optics. This is followed by a discussion of optical implementation of various types of flip-flop. These flip-flops are then used in the design of optical equivalents to a few simple sequential circuits such as shift registers and accumulators. As a typical sequential machine, a schematic layout for an optical binary temporal integrator is presented. Finally, a suggested experimental configuration for an optical master-slave flip-flop array is given.
Context. The astrophysical origin of the rapid neutron-capture process (r-process), responsible for producing roughly half of the elements heavier than iron, remains uncertain. Detailed chemical signatures from the oldest, most metal-poor stars, which act as fossil records of the earliest nucleosynthesis events, can be used to identify the dominant r-process sites. Aims. We present a homogeneous chemical abundance analysis of ten r-process element-enhanced stars. These old and metal-poor stars are strongly enriched in r-process elements with minimal contamination from other nucleosynthetic sources. By focusing on this chemically pure sample, we aim to investigate intrinsic variations in the r-process abundance patterns and explore their implications for the nature and potential diversity of r-process sites. Methods. We performed a detailed chemical abundance analysis of high-resolution, high-signal-to-noise spectra. For each star, we inspected over 1400 individual absorption lines using a combination of equivalent width measurements and spectral synthesis. The analysis was conducted under the assumption of 1D local thermodynamic equilibrium and employing the MOOG radiative transfer code. Results. We derived abundances for 54 chemical species, including 29 neutron-capture (n-capture) elements, covering the full mass range of the r-process abundance pattern. A kinematic analysis reveals that stars likely originated from ten kinematically distinct systems. Based on this assumption, we used the sample to probe the maximum variation expected from ten independent r-process nucleosynthesis events and computed the intrinsic dispersion of each element relative to Zr and Eu for the light and heavy r-process elements, respectively. This exercise resulted in a remarkably low cosmic scatter across the ten r-process sites enriching these stars; for the rare earth and third peak elements, for example, we find σ [La/Eu] = 0.08 and σ [Os/Eu] = 0.11 dex, while the scatter between light and heavy elements, σ [Zr/Eu] , is slightly higher at 0.18 dex. Conclusions. The elemental abundance patterns across the ten independent r-process sites show remarkably small cosmic dispersions. This minimal dispersion suggests a high degree of uniformity in r-process yields across diverse astrophysical environments.
A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.
Light-Front Holography is a remarkable consequence of the correspondence between string theory in AdS space and conformal field theories in physical-space time. It allows string modes {Phi}(z) in the AdS fifth dimension to be precisely mapped to the light-front wavefunctions of hadrons in terms of a specific light-front impact variable {zeta} which measures the separation of the quark and gluonic constituents within the hadron. This mapping was originally obtained by matching the exact expression for electromagnetic current matrix elements in AdS space with the corresponding exact expression for the current matrix element using light-front theory in physical space-time. More recently we have shown that one obtains the identical holographic mapping using matrix elements of the energy-momentum tensor, thus providing an important consistency test and verification of holographic mapping from AdS to physical observables defined on the light-front. The resulting light-front Schrodinger equations predicted from AdS/QCD give a good representation of the observed meson and baryon spectra and give excellent phenomenological predictions for amplitudes such as electromagnetic form factors and decay constants.
A system and method of detecting occupants in a building automation system environment using image based occupancy detection and position determinations. In one example, the system includes an image processing occupancy sensor that detects the number and position of occupants within a space that has controllable building elements such as lighting and ventilation diffusers. Based on the position and location of the occupants, the system can finely control the elements to optimize conditions for the occupants, optimize energy usage, among other advantages.
The unprecedented demand for sophisticated, self-powered, compact, ultrafast, cost-effective, and broadband light sensors for a myriad of applications has spurred a lot of research, precipitating in a slew of studies over the last decade. Apart from the photosensing ability of an active element in the light sensor, the device architecture is crucial in terms of photoinduced charge carrier generation and separation. Since the inception of graphene and the subsequent research growth in the atomically thin 2D materials, researchers have developed and adapted different families of 2D materials and device architectures, including single element 2D, 0D/2D, 2D/2D, 1D/2D stacked structures, and so on. Here this review discusses the recent reports on the light-sensing properties of various 2D materials, their heterostructures, and characteristics applicable to the ultraviolet-near infrared (UV-NIR), short-wave IR (SWIR), mid-wave IR (MWIR), long-wave IR (LWIR), and terahertz (THz) spectral ranges. It highlights the novelty of the burgeoning field, the heightened activity at the boundaries of engineering and materials science, particularly in the generation of charge carriers, their separation, and extraction, and the increased understanding of the underpinning science through modern experimental approaches. Devices based on the simultaneous effects of the pyro-phototronic effect (PPE) and the localized surface plasmon resonance (LSPR) effect, the photothermoelectric effect (PTE)-assisted photodetectors (PDs), waveguide-integrated silicon-2D PDs, metal-2D-metal PDs, and organic material PDs are examined rigorously. Theoretical treatment utilizing various computational approaches to investigate 2D materials and heterostructures for photodetection applications is also briefly discussed. At the end, current challenges and solutions to enhance the figures of merit of photodetectors are proposed.
A telescope with internal scanner utilizing either a single optical wedge scanner or a dual optical wedge scanner and a controller arranged to control a synchronous rotation of the first and/or second optical wedges, the wedges constructed and arranged to scan light redirected by topological surfaces and/or volumetric scatterers. The telescope with internal scanner further incorporates a first converging optical element that receives the redirected light and transmits the redirected light to the scanner, and a second converging optical element within the light path between the first optical element and the scanner arranged to reduce an area of impact on the scanner of the beam collected by the first optical element.
Fracturing of light water reactor (LWR) UO{sub 2} pellet has multiple important effects on fuel performance. One particularly important concern is that cracks in the fuel cause elevated stresses in the cladding when pellet cladding mechanical interaction (PCMI) occurs. The extended finite element method (XFEM) is a powerful method to represent arbitrary propagating discrete cracks in finite element models. The use of XFEM has been previously demonstrated for modeling propagating discrete cracks in the BISON fuel performance code. This paper demonstrates an initial application of XFEM to model stress concentrations induced by fuel fractures at the fuel/cladding interface during PCMI. This is demonstrated on a study of a pre-defined stationary crack in a 2D cross-section model of a LWR fuel rod. The results from a model with a discrete crack defined with XFEM compare favorably with the results from a model with the same crack geometry defined in the finite element mesh. This study focuses on benchmarking the use of XFEM for PCMI modeling with a stationary crack, but this technique will be readily extended in the future to consider PCMI in conjunction with arbitrary, physics-driven crack propagation. (authors)
Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.
We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing five orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering delta-lamda/lamda = 1/7 at a resolution of delta-lamda/lamda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve doppler broadened line emission from external galaxies. FIBRE operates in the 350 micrometer and 450 micrometer bands. These bands cover line emission from the important PDR tracers neutral carbon [CI] and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.