Search NASA⌕ Search

SEARCH · Search NASA

Results for “load frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

On the Stability of Power Transmission Systems Under Persistent Inverter Attacks: A Bi-Linear Matrix Approach

We investigate the stability and robustness properties of a power transmission system under persistent deceiving attacks on inverter-interfaced energy resources. The attacks can corrupt the damping coefficients in the inverters' controllers and measurements of the frequency at the points of coupling. Leveraging tools from hybrid dynamical systems theory, we characterize a broad family of persistent (and not necessarily periodic) attacks acting on the inverters, under which the stability properties of the transmission system can be shown to not be compromised. To address potentially conservative conditions identified through conventional bounding techniques, sufficient conditions on the average activation time of the attacks are identified via Lyapunov theory, as well as the formulation and solution of a class of bilinear matrix inequalities (BMI). The results are obtained for constant and slowly time-varying loads via input-to-state stability (ISS) tools. Numerical simulations on the IEEE 39-bus test system are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SIEMENS ADVANCED QUANTRA FTICR MASS SPECTROMETER FOR ULTRA HIGH RESOLUTION AT LOW MASS

The Siemens Advanced Quantra Fourier Transform Ion Cyclotron Resonance (FTICR) mass spectrometer was evaluated as an alternative instrument to large double focusing mass spectrometers for gas analysis. High resolution mass spectrometers capable of resolving the common mass isomers of the hydrogen isotopes are used to provide data for accurate loading of reservoirs and to monitor separation of tritium, deuterium, and helium. Conventional double focusing magnetic sector instruments have a resolution that is limited to about 5000. The Siemens FTICR instrument achieves resolution beyond 400,000 and could possibly resolve the tritium ion from the helium-3 ion, which differ by the weight of an electron, 0.00549 amu. Working with Y-12 and LANL, SRNL requested Siemens to modify their commercial Quantra system for low mass analysis. To achieve the required performance, Siemens had to increase the available waveform operating frequency from 5 MHz to 40 MHz and completely redesign the control electronics and software. However, they were able to use the previous ion trap, magnet, passive pump, and piezo-electric pulsed inlet valve design. NNSA invested $1M in this project and acquired four systems, two for Y-12 and one each for SRNL and LANL. Siemens claimed a $10M investment in the Quantra systems. The new Siemens Advanced Quantra demonstrated phenomenal resolution in the low mass range. Resolution greater than 400,000 was achieved for mass 2. The new spectrometer had a useful working mass range to 500 Daltons. However, experiments found that a continuous single scan from low mass to high was not possible. Two useful working ranges were established covering masses 1 to 6 and masses 12 to 500 for our studies. A compromise performance condition enabled masses 1 to 45 to be surveyed. The instrument was found to have a dynamic range of about three orders of magnitude and quantitative analysis is expected to be limited to around 5 percent without using complex fitting algorithms. Analysis of low concentration ions, at the ppm level, required a separate analysis using ion ejection techniques. Chemical ionization due to the formation of the MH{sup +} ion or MD{sup +} increased the complexity of the spectra compared to magnetic sector mass spectra and formation of the protonated or deuterated complex was a dynamic function of the trap ion concentration. This made quantitative measurement more of a challenge. However, the resolution of the instrument was far superior to any other mass spectrometry technique that has been applied to the analysis of the hydrogen isotopes. The piezo-electric picoliter injection device offers a new way of submitting small quantities of atmospheric pressure sample gas for analysis. The new software had many improvements over the previous version but significant flaws in the beta codes remain that make the prototype units less than ideal. The instrument is a promising new technology that experience will likely improve. Unfortunately, Siemens has concluded that the technology will not be a commercial success and has decided to stop producing this product.

74 ATOMIC AND MOLECULAR PHYSICS↗

A full-scale wind tunnel investigation of a helicopter bearingless main rotor

A helicopter bearingless main rotor was tested. Areas of investigation included aeroelastic stability, aerodynamic performance, and rotor loads as a function of collective pitch setting, RPM, airspeed and shaft angle. The rotor/support system was tested with the wind tunnel balance dampers installed and, subsequently, removed. Modifications to the rotor hub were tested. These included a reduction in the rotor control system stiffness and increased flexbeam structural damping. The primary objective of the test was to determine aeroelastic stability of the fundamental flexbeam/blade chordwise bending mode. The rotor was stable for all conditions. Damping of the rotor chordwise bending mode increases with increased collective pitch angle at constant operating conditions. No significant decrease in rotor damping occured due to frequency coalescence between the blade chordwise fundamental bending mode and the support system.

Warmbrodt, W.↗

Control approach for power modulation of end-use loads

Methods, apparatus, and systems are disclosed herein for power modulation control of power grids using end-use loads. At the beginning of a coordination period typically lasting a few minutes, a population of end-use loads (water heaters, air conditioners, plug-in electric vehicles, etc.) is interrogated for their willingness to participate in power modulation by undergoing state transitions from on to off, or off to on. Distribution system flexibilities are calculated from the sums of device powers within distribution systems. Area flexibilities are calculated from the sums of device powers within areas. Thresholds for various devices to change state in response to inter-area oscillation damping or frequency regulation are derived from these flexibilities. Two power functions are monitored in real-time and compared with the device thresholds to trigger state changes which then remain locked throughout the remainder of the coordination period, then the devices are released from the lockout state.

Lian, Jianming↗

Deep Learning-Based Data Forgery Detection in Automatic Generation Control

Automatic Generation Control (AGC) is a key control system in the power grid. It is used to calculate the Area Control Error (ACE) based on frequency and tie-line power flow between balancing areas, and then adjust power generation to maintain the power system frequency in an acceptable range. However, attackers might inject malicious frequency or tie-line power flow measurements to mislead AGC to do false generation correction which will harm the power grid operation. Such attacks are hard to be detected since they do not violate physical power system models. In this work, we propose algorithms based on Neural Network and Fourier Transform to detect data forgery attacks in AGC. Different from the few previous work that rely on accurate load prediction to detect data forgery, our solution only uses the ACE data already available in existing AGC systems. In particular, our solution learns the normal patterns of ACE time series and detects abnormal patterns caused by artificial attacks. Evaluations on the real ACE dataset show that our methods have high detection accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Configuration of Paralleled Modular ANPC Multilevel Converter Controlled by an Improved Modulation Method for 1 MHz, 1 MW EV Charger

In this work, a new configuration of the modular multilevel converter (MLC) based on the parallel connection of three-level active-neutral-point-clamped (3L-ANPC) cells as well as its improved modulation method is proposed for 1 MHz, 1 MW electric vehicle (EV) megacharger. In the proposed paralleled modular ANPC-MLC, only six high-frequency silicon carbide (SiC) power switches operating at 333 kHz are required to generate 1 MHz switching frequency spectrum. Moreover, the operating voltage of all power devices is halved, the magnitude of the first switching frequency harmonic cluster is decreased by the factor of five, and the load current is equally distributed between the 3L-ANPC legs by employing the proposed improved modulation method. Hence, the modularity, efficiency, and power density of the proposed converter are notably increased, whereas the value of passive components and the overall switching loss are remarkably decreased. In addition, an optimized design of the one 3L-ANPC cell of the proposed paralleled modular ANPC-MLC for 1 MHz, 1MW EV megacharger using Ansys SIwave, Icepak, and Q3D finite element method platforms is presented and analyzed in detail. The provided experimental results of the down-scaled setup verify the feasibility and viability of the proposed configuration as well as its improved switching pattern.

42 ENGINEERING↗

A Soft-Switching Inverter for High-Temperature Advanced Hybrid Electric Vehicle Traction Motor Drives

The state-of-the-art hybrid electric vehicles (HEVs) require the inverter cooling system to have a separate loop to avoid power semiconductor junction over temperatures because the engine coolant temperature of 105°C does not allow for much temperature rise in silicon devices. The proposed work is to develop an advanced soft-switching inverter that will eliminate the device switching loss and cut down the power loss so that the inverter can operate at high-temperature conditions while operating at high switching frequencies with small current ripple in low inductance based permanent magnet motors. The proposed tasks also include high-temperature packaging and thermal modeling and simulation to ensure the packaged module can operate at the desired temperature. The developed module will be integrated with the motor and vehicle controller for dynamometer and in-vehicle testing to prove its superiority. This report will describe the detailed technical design of the soft-switching inverters and their test results. The experiments were conducted both in module level for the module conduction and switching characteristics and in inverter level for its efficiency under inductive and dynamometer load conditions. The performance will be compared with the DOE original specification.

33 ADVANCED PROPULSION SYSTEMS↗

Nonlinear coupled rotor-fuselage helicopter vibration studies with higher harmonic control

This paper addresses the problem of vibration prediction and vibration reduction in helicopters by means of active control methodologies. The nonlinear equations of a coupled rotor/flexible-fuselage system have been derived using computer algebra, thus relegating this tedious task to the computer. In the solution procedure the trim state and vibratory response of the helicopter are obtained in a single pass by using a harmonic balance technique and simultaneously satisfying the trim and the vibratory response of the helicopter in all the rotor and fuselage degrees of freedom. Using this solution procedure, the influence of the fuselage flexibility on the vibratory response is studied. In addition, it is shown that the conventional single frequency HHC is capable of reducing either the hub loads or only the fuselage vibrations but not both simultaneously. A new scheme called MHHC, having multiple higher harmonic pitch inputs, was used to accomplish this task of simultaneously reducing both the vibratory hub loads and fuselage vibratory response. In addition, the uniqueness of this MHHC scheme is explained in detail.

Friedmann, P. P.↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

The effect of water vapor on fatigue crack Growth in 7475-t651 aluminum alloy plate

The effects of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate at frequencies of 1 Hz and 10 Hz were investigated. Twenty-five mm thick compact specimens were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Fatigue crack growth rates were calculated from effective crack lengths determined using a compliance method. Tests were conducted in hard vacuum and at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. Fatigue crack growth rates were frequency insensitive under all environment conditions tested. For constant stress intensity factor ranges crack growth rate transitions occurred at low and high water vapor pressures. Crack growth rates at intermediate pressures were relatively constant and showed reasonable agreement with published data for two Al-Cu-Mg alloys. The existence of two crack growth rate transitions suggests either a change in rate controlling kinetics or a change in corrosion fatigue mechanism as a function of water vapor pressure. Reduced residual deformation and transverse cracking specimens tested in water vapor versus vacuum may be evidence of embrittlement within the plastic zone due to environmental interaction.

Dicus, D. L.↗

Effect of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate

The effects of water vapor on fatigue crack growth in 7475-T651 aluminum alloy plate at frequencies of 1 Hz and 10 Hz were investigated. Twenty-five mm thick compact specimens were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Fatigue crack growth rates were calculated from effective crack lengths determined using a compliance method. Tests were conducted in hard vacuum and at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. Fatigue crack growth rates were frequency insensitive under all environment conditions tested. For constant stress intensity factor ranges crack growth rate transitions occurred at low and high water vapor pressures. Crack growth rates at intermediate pressures were relatively constant and showed reasonable agreement with published data for two Al-Cu-Mg alloys. The existence of two crack growth rate transitions suggests either a change in rate controlling kinetics or a change in corrosion fatigue mechanism as a function of water vapor pressure. Reduced residual deformation and transverse cracking specimens tested in water vapor versus vacuum may be evidence of embrittlement within the plastic zone due to environmental interaction.

Dicus, D. L.↗

Definition of ground test for verification of large space structure control

Directions regarding the analytical models were received. A counter balance arm with weights was added at the top of the ASTROMAST to offset the arm with the gimbals. In addition to this model, three more models were requested from MSFC: structure as in the revised model with the addition of lumped masses at bays 46 and 91 of the ASTROMAST; cantilevered cruciform structure with lumped masses at bays 46 and 91, and an all up cruciform structure with lumped masses at bays 46 and 91. Figures for each model and their corresponding natural frequencies and general mode shapes associated with these frequencies are included. The drawbar in use in the cruciform models must be incorporated into the antenna and ASTROMAST models. The total tensile load carrying capability of the ASTROMAST is approximately 840 pounds.

Seltzer, S. M.↗

Impacts of Lock-off Time on Virtual Battery Model from Thermostatically Controlled Loads

We test through simulation the influence of lock-off time on the aggregated flexibility of thermostatically controllable loads (TCLs), which is modeled by virtual battery (VB) models. The VB model provides a simple but effective way to quantify the aggregated flexibility of TCLs, but its efficacy is not clear when there is lock-off time for TCLs. TCLs cannot be turned on during the lock-off period, and so lock-off time imposes inevitable restrictions on not only the flexibility of individual TCLs but also the aggregated flexibility of a group of TCLs. We first test the influence of lock-off time on the efficacy of VB models with two artificial signals. One of the signal is of low frequency while the other is of high frequency. We then use real-world data to test the influence. One set of data is from a duck curve from CAISO while the other set of data is from AGC signals from PJM. The duck curve changes slowly while the AGC signals change rapidly over time. From both the artificial signals and real-word data, we find that lock-off time has a more significant impact on rapid signals than on slow signals.

Wang, Peng↗

Safe Deep Reinforcement Learning for Robust Frequency and Voltage-Constrained Networked Microgrid Restoration

Here, this paper proposes a safe soft actor-critic reinforcement learning (RL) algorithm–based controller for networked microgrid restoration. It formulates the post black-start start as a finite-horizon constrained Markov decision process. The RL agent co-optimizes real and reactive power set-points for both grid-forming and grid-following inverters under explicit voltage and frequency constraints, while enforcing proper power sharing via the Mean Active Power Sharing Index (MPSI) and Mean Reactive Power Sharing Index (MQSI). Numerical results obtained on the IEEE 123-bus distribution system show that the proposed method achieves a mean voltage build-up time of 0.01 s without breaching the 5% sharing-violation budget under various load scenarios, considering MPSI and MQSI indices. These findings demonstrate that the proposed method yields fast and safe black-start schedules without resorting to heuristic penalties.

Selim, Alaa [Dartmouth College, Hanover, NH (Unite↗

Output energy parameters of a KULON-10Cu-UV laser

The output energy parameters of an industrial KULON copper vapour laser equipped with a nonlinear frequency converter based on DKDP and BBO crystals are studied. The average and peak powers, as well as the energies and pulse durations of radiation at wavelengths of 510, 578, 255, 271, and 289 nm, are measured in the regime of high-speed pulse modulation, which is used in lasers of this series. The maximum average power was 420 mW at a wavelength of 271 nm (DKDP) and 350 and 110 mW at 255 and 289 nm, respectively (BBO). It is experimentally shown that the average energy characteristics of UV radiation can be controlled on-line by changing the pulse repetition rate of the laser. (lasers and amplifiers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction of High-cycle and Low-cycle Fatigue of Haynes 188 Alloy at 1400 F Deg

The interaction of low-cycle fatigue (LCF) and high-cycle fatigue (HCF) was evaluated at the NASA Lewis Research Center on Haynes 188 alloy at 1400 F. Completely reversed, axial-load, strain-controlled fatigue tests were performed to determine the baseline data for this study. Additional specimens for interaction tests were cycled first at a high strain range for various small portions of expected LCF life followed by a step change to a low strain range to failure in HCF. Failure was defined as complete specimen separation. The resultant lives varied between 10 and 5000 cycles for the low-cycle fatigue tests and between 4500 and 3 million for the high-cycle fatigue tests. For the interaction tests the low-cycle-life portion ranged from 30 and 1000 applied cycles while the high-frequency life ranged from 300 and 300,000 cycles to failure. The step change results showed a significant nonlinear interaction in expected life. Application of a small part of the LCF life drastically decreased the available HCF life as compared with what would have been expected by the classical linear damage rule (LDR).

Peter T Bizon↗

Baseband Digital Network Analyzer Upgrade for LLRF Controllers

Digital Network Analyzers (DNA) have been implemented in many Low-Level Radio Frequency (LLRF) systems, notably NSLS-II and CERN, to help tune feedback loops. DNA characterizes feedback loops by measuring the frequency-dependent magnitude and phase transfer functions. It enables the measurement of open loop gains, gain/phase margins, and loop delays to help fine-tune feedback loops. An FPGA-based DNA has been developed and integrated into the current Relativistic Heavy Ion Collider (RHIC) LLRF infrastructure. Its performance has been tested with an implementation of one-turn delay feedback (OTFB) on the bench to maximize gain and stability. The DNA has been used to characterize a RHIC 28 MHz cavity in a RHIC Accelerator Physics Experiment (APEX) to test transient beam loading compensation strategies.

43 PARTICLE ACCELERATORS↗