Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

UWB Tracking System Design for Lunar/Mars Exploration

This paper describes a design effort for a prototype ultra-wideband (UWB) tracking system that is currently under development at NASA Johnson Space Center (JSC). The system is being studied for use in tracking of lunar/Mars rovers during early exploration missions when satellite navigation systems are not available. The UWB technology is exploited to implement the tracking system due to its properties such as high data rate, fine time resolution, low power spectral density, and multipath immunity. A two-cluster prototype design using commercially available UWB products is proposed to implement the Angle Of Arrival (AOA) tracking methodology in this research effort. An AOA technique using the Time Difference Of Arrival (TDOA) information is utilized for location estimation in the prototype system, not only to exploit the precise time resolution possible with UWB signals, but also to eliminate the need for synchronization between the transmitter and the receiver. After the UWB radio at each cluster is used to obtain the TDOA estimates from the UWB signal sent from the target, the TDOA data is converted to AOA data to find the angle of arrival, assuming this is a far field application. Since the distance between two clusters is known, the target position is computed by a simple triangulation. Simulations show that the average tracking error at a range of 610 meters is 2.7595 meters, less than 0.5% of the tracking range. Outdoor tests to track the SCOUT vehicle (The Science Crew Operations and Utility Testbed) near the Meteor Crater, Flagstaff, Arizona were performed on September 12-13, 2005. The tracking performance was obtained with less than 1% tracking error at ranges up to 2000 feet. No RF interference with on-board GPS, video, voice and telemetry systems was detected. Outdoor tests demonstrated the UWB tracking capability.

Ni, Jianjun↗

X-Ray Imagery as the Record of All Data of Interest in Hypervelocity Impact Fragment Studies

Laboratory study of hypervelocity spacecraft fragmentation has traditionally involved the collection and analysis of fragments that were caught in deceleration material surrounding the impact. This process has typically involved the disintegration of the catchment material either through chemical dissolution, or through physical excavation to recover the fragments. Due to the scale of the three impact tests—the Satellite Orbital Debris Characterization Impact Test (SOCIT), the DebriSat satellite impact test, and the DebrisLV launch vehicle impact test—the latter two using more than 12 cubic meters of polyurethane foam to capture the fragments, hese projects have used x-ray imagery to precisely locate and thus, to more efficiently extract fragments in the soft-catch material. Three years into the DebriSat fragment extraction process, a side study was initiated to explore what additional information could be discerned from the x-rays, with significant results. This study was instrumental to a rapid replacement and retooling as the project was forced to replace the x-ray system around which the extraction process had been based. The revised process continues to map the debris for extraction. The project has, in parallel, systematically addressed the limits/tolerances of what x-rays can reveal about size, shape, density, mass, velocity, energy, and deformation/damage of the fragment during the deceleration in the catchment material while replicating the original extraction mapping function. All of these features have been optimized or have sufficient understanding to characterize the basic factors that will define a complete data set extracted solely from x-ray imagery. It is an ideal time to develop such a process, with extracted fragments providing “ground truth” against image-only data, and abundant available imagery of the same fragments under both the prior and replacement x-ray technologies, which have several fundamentally different characteristics. This paper addresses the types and quality of hypervelocity fragmentation data that can be and has been extracted from x-rays. It further addresses the question of whether and under what circumstances future hypervelocity experiments can use x-ray methods to largely—or to completely—avoid the extraction process in recording all appropriate results. Lastly, this paper addresses lessons learned and how future efforts can be further optimized.

John B. Bacon↗

Flight Demonstration of the Tailored Arrival Manager

A flight demonstration of arrival traffic management automation was conducted in partnership between NASA, FAA and Boeing as an element of the latter’s ecoDemonstrator2020 flight program. For the demonstration, NASA’s prototype Tailored Arrival Manager(TAM) was used to compute efficient trajectory-based solutions to traffic management problems representing those encountered during time-based metering operations today. TAM solutions involving route modifications were uplinked to a Boeing 787 airplane using Controller Pilot Data Link Communications and seamlessly loaded into the airplane’s Flight Management System (FMS). The paper describes the concept and technology behind TAM along with the data exchanges and procedures involved with the demonstration. All TAM solutions were delivered in a timely manner and successfully integrated with the airplane’s FMS, thereby demonstrating the basic feasibility of trajectory-based arrival management using currently available data communications and avionics equipage. Although TAM solutions were not executed during this initial demonstration, a limited study of trajectory prediction accuracy was possible given that the airplane flew uninterrupted, automated descents with known route and speed intent. Analysis revealed that TAM meter-fix arrival time predictions were accurate to within ± 30 seconds for time horizons of 30 minutes or less, which matched closely with FMS predictions acquired through real-time data exchange. Top-of-descent predictions over similar time horizons were found accurate to within ± 5 nautical miles.

Air traffic managment↗

Analysis of Triangular Rollable and Collapsible Composite Booms Under the Effects of Gravity and Twist

Finite element analysis is used to investigate Triangular Rollable and Collapsible (TRAC) composite booms. The TRAC booms are subjected to a suite of loading conditions, including in-plane bending, out-of-plane bending, and axial compression. Simulations containing as-designed boom geometry are performed, as are simulations with geometric deviations associated with the as-built conditions of a sample TRAC boom. Namely, a cross-sectional twist along the length of the boom is incorporated into the analysis to study the effect of the twist on the deformation characteristics of the boom. Twisting in the sample boom was observed after short-term storage in a rolled configuration and may be attributed to differential creep deformation between the inner and outer flanges of the TRAC boom. Simulations are conducted with and without the effects of gravity to understand the significance of gravity on testing conditions. Booms of three lengths are evaluated: 3 meters, 7.5 meters and 30 meters. The mechanical responses of the TRAC booms are discussed with reference to the effects of gravity, boom length and cross-sectional twisting. Gravity is found to have a more significant effect on boom mechanical response as boom length is increased. Cross-sectional twisting is found to have a more significant effect on boom mechanical response in the shorter booms.

High-strain composites↗

Analysis of Triangular Rollable and Collapsible (TRAC) Composite Booms under the Effects of Gravity and Twist

Finite element analysis is used to investigate Triangular Rollable and Collapsible (TRAC) composite booms. The TRAC booms are subjected to a suite of loading conditions, including in-plane bending, out-of-plane bending, and axial compression. Simulations containing as-designed boom geometry are performed, as are simulations with geometric deviations associated with the as-built conditions of a sample TRAC boom. Namely, a cross-sectional twist along the length of the boom is incorporated into the analysis to study the effect of the twist on the deformation characteristics of the boom. Twisting in the sample boom was observed after short-term storage in a rolled configuration and may be attributed to differential creep deformation between the inner and outer flanges of the TRAC boom. Simulations are conducted with and without the effects of gravity to understand the significance of gravity on testing conditions. Booms of three lengths are evaluated: 3 meters, 7.5 meters and 30 meters. The mechanical responses of the TRAC booms are discussed with reference to the effects of gravity, boom length and cross-sectional twisting. Gravity is found to have a more significant effect on boom mechanical response as boom length is increased. Cross-sectional twisting is found to have a more significant effect on boom mechanical response in the shorter booms.

High-strain composites↗

Fast DR: Controlling Small Loads over the Internet

Current state-of-the-art demand response systems are expensive due to extreme reliability constraints in telemetry, control, and metering. The typical cost of enabling a site for regulation services is between $50k and $80k. These costs are orders of magnitude too high for small loads to participate in high-value grid services. Traditional demand response (DR) schedules events in advance and provides basic on/off control. We developed fast DR measurement and communication technologies, which are scalable cost-effective demand response systems with sufficient reliability for real-time control and monitoring of loads over the internet, and we demonstrated an example system for under $100. We installed FastDR systems for lighting, motor, and thermostat control along with power metering at a total of 10 sites, including 6 commercial buildings and 4 residential buildings. This demonstration addressed the following important methodological questions: 1) Can we reliably control loads simultaneously and with low latency across multiple sites within a specified response time; 2) How reliable is using the internet or 4G cellular network as the mode of control and metering; and 3) Can existing Smart Meters provide data for real-time telemetry services. Testing shows fast DR is capable of control to response in 4 seconds and loads complete transition in seconds to less than one minute depending on load type. We demonstrated 4s regulation services and synchronized load control, and we successfully met specifications for ancillary services across the US. Telemetry via the 4G cellular network demonstrated 94.5% success rate, and residential Internet demonstrated a 98% success rate.

Kiliccote, Sila↗

Scaling Building Energy Audits through Machine Learning Methods on Novel Drone Image Data

Building energy audits are time-consuming and labor-intensive. This paper describes a new method using machine learning (ML) techniques on novel data sources (drone images) to improve the identification of building characteristics and retrofit opportunities, and thereby reduce the effort for audits. The new ML method includes: (1) Building footprint extraction using line extraction, polygonization, and polygon-merging, (2) Building envelope extraction using PIX4d modeling software to reconstruct a building 3D model, (3) Visualization tool for viewing images from the 3D model, (4) Window-to-wall ratio (WWR) using state-of-art deep neural network semantic segmentation, (5) Envelope thermal anomaly detection using an unsupervised machine learning clustering algorithm, and (6) Rooftop energy equipment detection based on an object detection algorithm. The testing of this method involved a comparison of additional ML-generated information overlaid on current ‘state-of-practice’ audit and remote assessment baselines using evaluation metrics: labor time and associated cost, marginal benefits of using ML-generated information in workflows for audits and remote assessments, integration potential with existing processes and tools, and replicability/scalability of the method. In two test buildings in California that had comprehensive drawings and meter data available, the ML method effectively generated a building footprint, envelope, rooftop equipment, WWR, and locations of envelope thermal anomalies. Projected target segments of the ML method are sites with minimal drawings and energy data, and underserved sectors such as multistoried housing, disadvantaged communities, and schools for which the ML method can enable identification of building asset characteristics and prioritization of envelope retrofits and decentralized energy equipment retrofits.

Singh, Reshma↗

Wireless Indoor Location Estimation Based on Neural Network RSS Signature Recognition (LENSR)

Location Based Services (LBS), context aware applications, and people and object tracking depend on the ability to locate mobile devices, also known as localization, in the wireless landscape. Localization enables a diverse set of applications that include, but are not limited to, vehicle guidance in an industrial environment, security monitoring, self-guided tours, personalized communications services, resource tracking, mobile commerce services, guiding emergency workers during fire emergencies, habitat monitoring, environmental surveillance, and receiving alerts. This paper presents a new neural network approach (LENSR) based on a competitive topological Counter Propagation Network (CPN) with k-nearest neighborhood vector mapping, for indoor location estimation based on received signal strength. The advantage of this approach is both speed and accuracy. The tested accuracy of the algorithm was 90.6% within 1 meter and 96.4% within 1.5 meters. Several approaches for location estimation using WLAN technology were reviewed for comparison of results.

99 GENERAL AND MISCELLANEOUS↗

Measurement of Resistance and Strength of Conductor Splices in the MICE Coupling Magnets

The superconducting magnets for the Muon Ionization Cooling Experiment [1] (MICE) use a copper based Nb-Ti conductor with un-insulated dimensions of 0.95 by 1.60 mm. There may be as many as twelve splices in one MICE superconducting coupling coil. These splices are to be wound in the coil. The conductor splices produce Joule heating, which may cause the magnet to quench. A technique of making conductor splices was developed by ICST. Two types of 1-meter long of soldered lap-joints have been tested. Side-by-side splices and up-down one splices were studied theoretically and experimentally using two types of soft solder made of eutectic tin-lead solder and tin-silver solder. The resistances of the splices made by ICST were tested at LBNL at liquid helium temperatures over a range of magnetic fields up to 5 T. The breaking strength of 250 mm long splices was also measured at room temperature and liquid nitrogen temperature.

42 ENGINEERING↗

Convergence of Emerging Technologies - Magos Test Results

The Magos SR-1000 is a ground surveillance radar with an advertised detection range up to 1000 meters for a walker, vehicle, or boat at a low power consumption of 11 Watts. Figure 1 shows the Magos SR-1000 installed at Sandia’s Security Technology Test and Evaluation Center (STEC); testing was performed from May-July 2024. Figure 2 shows a close-up of the device.

47 OTHER INSTRUMENTATION↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Density and Cavitating Flow Results from a Full-Scale Optical Multiphase Cryogenic Flowmeter

Liquid propulsion systems are hampered by poor flow measurements. The measurement of flow directly impacts safe motor operations, performance parameters as well as providing feedback from ground testing and developmental work. NASA Marshall Space Flight Center, in an effort to improve propulsion sensor technology, has developed an all optical flow meter that directly measures the density of the fluid. The full-scale sensor was tested in a transient, multiphase liquid nitrogen fluid environment. Comparison with traditional density models shows excellent agreement with fluid density with an error of approximately 0.8%. Further evaluation shows the sensor is able to detect cavitation or bubbles in the flow stream and separate out their resulting effects in fluid density.

Korman, Valentin↗

Effects of a modified leading edge on noise and boundary-layer transition in a rod-wall sound shield at Mach 5

A version of a rod wall sound shield was tested in the Mach 5 pilot quiet tunnel over a range of unit Reynolds numbers from 10 to 35 million per meter. The model was modified by inclining the leading edge plates to produce an initial 2 deg expansion to ascertain the sensitivity of boundary layer transition to leading edge disturbances. Rod surface pitot pressures, mean free stream pitot pressures, and static pressures on the rods and plenum walls were measured. Hot-wire measurements were also made in the model and nozzle free stream at a unit Reynolds number of 15 million per meter. The surface pitot pressures indicated that transition was much farther forward than for the previous tests due to the leading edge modification and minor fabrication flaws in the model. Early boundary layer transition on the rods was confirmed by hot-wire measurements which showed much higher noise levels in the free stream shield flow when compared with results from previous tests. Mean pitot pressure surveys within the shielded region inside the model indicated that there was an overexpansion and recompression that would limit the streamwise length of undisturbed flow to about 13 cm along the centerline.

Creel, T. R., Jr.↗

Reflection type skin friction meter

A housing block is provided having an upper surface conforming to the test surface of a model or aircraft. An oil film is supplied upstream of a transparent wedge window located in this upper surface by an oil pump system located external to the housing block. A light source located within the housing block supplies a light beam which passes through this transparent window and is reflected back through the transparent window by the upper surface of the oil film to a photo-sensitive position sensor located within the housing. This position sensor allows the slope history of the oil film caused by and aerodynamic flow to be determined. The skin friction is determined from this slope history. Internally located mirrors augment and sensitize the reflected beam as necessary before reaching the position sensor. In addition, a filter may be provided before this sensor to filter the beam.

Bandyopadhyay, Promode R.↗

Comparison of Hover/Ground-Effect Characteristics for a Joint Strike Fighter Configuration

Hover and ground-effect tests were conducted with the Lockheed-Martin Large Scale Powered Model (LSPM) during June-November 1995 at the NASA Ames Research Center's Outdoor Aerodynamics Research Facility (OARF). This was done in support of the Joint Strike Fighter (JSF) Program being lead by the Department of Defense. The program was previously metered to as the Joint Advanced Strike Technology (JAST) Program. The tests at the OARF included: engine thrust calibrations out of ground effect, measurements of individual nozzle jet pressure decay characteristics, and jet-induced hover force and moment measurements in and out of ground effect. The engine calibrations provide data correlating propulsion system throttle and nozzle settings to thrust forces and moments for the bare fuselage with the wings, canards, and tails removed. This provides propulsive forces and moments while minimizing any of the effects due to the presence of the airframe. The engine calibrations were used later to determine thrust for hover testing at the OARF and for transition testing which took place in the NASA Ames 80 by 120 foot Wind Tunnel. The jet decay characteristics reflect the jet entrainment properties and are related to the aircraft suckdown characteristics. The JSF program provided the opportunity to obtain model scale effects using two models; one at small scale and one at large scale. Examples of data from these tests will be presented out of ground effect which will demonstrate the effect of scale. For one JSF configuration, two small-scale models and one large-scale model were tested and obtained different values for the lift loss out of ground effect. These differences were examined and are found to be largely dependent on the jet efflux characteristics. The jet-induced hover forces and moments are presented in and out of ground effect. For the hover testing the model is methodically built up from the bare fuselage, to include the wings, canards, and vertical tails, to determine the effects of each. Other components such as weapons bay doors, landing gear doors, and other lift improvement devices and their effect on the jet-induced forces and moments are examined.

Hange, Craig↗

Analysis of the NASA White Sands Test Facility (WSTF) Test System for Friction-Ignition of Metallic Materials

Friction is a known ignition source for metals in oxygen-enriched atmospheres. The test system developed by the NASA White Sands Test Facility in response to ASTM G-94 has been used successfully to determine the relative ignition from friction of numerous metallic materials and metallic materials pairs. These results have been ranked in terms of a pressure-velocity product (PV) as measured under the prescribed test conditions. A high value of 4.1(exp 8) watts per square meter for Inconel MA 754 is used to imply resistance to friction ignition, whereas a low value of 1.04(exp 8) watts per square meter for stainless steel 304 is taken as indicating material susceptible to friction ignition. No attempt has been made to relate PV values to other material properties. This work reports the analysis of the WSTF friction-ignition test system for producing fundamental properties of metallic materials relating to ignition through friction. Three materials, aluminum, titanium, and nickel were tested in the WSTF frictional ignition instrument system under atmospheres of oxygen or nitrogen. Test conditions were modified to reach a steady state of operation, that is applied, the force was reduced and the rotational speed was reduced. Additional temperature measurements were made on the stator sample. The aluminum immediately galled on contact (reproducible) and the test was stopped. Titanium immediately ignited as a result of non-uniform contact of the stator and rotor. This was reproducible. A portion of the stator sampled burned, but the test continued. Temperature measurements on the stator were used to validate the mathematical model used for estimating the interface (stator/rotor) temperature. These interface temperature measurements and the associate thermal flux into the stator were used to distinguish material-phase transitions, chemical reaction, and mechanical work. The mechanical work was used to analyze surface asperities in the materials and to estimate a coefficient of fiction. The coefficient of fiction was analyzed in terms of material properties that is, hardness, Young's modulus and elasticity/plasticity of the material.

Shoffstall, Michael S.↗

Dynamic measurement of total temperature, pressure and velocity in the Langley 0.3-meter transonic cryogenic tunnel

There is theoretical and experimental evidence which indicates that a sudden or step change in the rate at which the liquid nitrogen is injected into the circuit of a cryogenic wind tunnel can cause a temperature front in the flow for several tunnel circuit times. A temperature front, which occurs at intervals equal to the circuit time, is a sudden increase or decrease in the temperature of the flow followed by a nearly constant temperature. Since these fronts can have an effect on the control of the tunnel as well as the time required to establish steady flow conditions in the test section of cryogenic wind tunnel, tests were conducted in the settling chamber in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT) in which high response instrumentation was used to measure the possible existence of these temperature fronts. Three different techniques were used to suddenly change the rate of liquid nitrogen being injected into the tunnel and the results from these three types of tests showed that temperature fronts do not appear to be present in the 0.3-m TCT. Also included are the velocity and pressure fluctuations measured in the settling chamber downstream of the screens and the associated power spectra.

Johnson, C. B.↗

Parachute Decelerator System Performance During the Low Density Supersonic Decelerator Program's First Supersonic Flight Dynamics Test

During the first Supersonic Flight Dynamics Test (SFDT-1) for NASA's Low Density Supersonic Decelerator (LDSD) Program, the Parachute Decelerator System (PDS) was successfully tested. The main parachute in the PDS was a 30.5-meter supersonic Disksail parachute. The term Disksail is derived from the canopy's constructional geometry, as it combined the aspects of a ringsail and a flat circular round (disk) canopy. The crown area of the canopy contained the disk feature, as a large flat circular disk that extended from the canopy's vent down to the upper gap. From this upper gap to the skirt-band the canopy was constructed with characteristics of sails seen in a ringsail. There was a second lower gap present in this sail region. The canopy maintained a nearly 10x forebody diameter trailing distance with 1.7 Do suspension line lengths. During the test, the parachute was deployed at the targeted Mach and dynamic pressure. Although the supersonic Disksail parachute experienced an anomaly during the inflation process, the system was tested successfully in the environment it was designed to operate within. The nature of the failure seen originated in the disk portion of the canopy. High-speed and high-resolution imagery of the anomaly was captured and has been used to aid in the forensics of the failure cause. In addition to the imagery, an inertial measurement unit (IMU) recorded test vehicle dynamics and loadcells captured the bridle termination forces. In reviewing the imagery and load data a number of hypothesizes have been generated in an attempt to explain the cause of the anomaly.

Gallon, John C.↗