Search NASA⌕ Search

SEARCH · Search NASA

Results for “missing values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Encryption for Remote Control via Internet or Intranet

A data-communication protocol has been devised to enable secure, reliable remote control of processes and equipment via a collision-based network, while using minimal bandwidth and computation. The network could be the Internet or an intranet. Control is made secure by use of both a password and a dynamic key, which is sent transparently to a remote user by the controlled computer (that is, the computer, located at the site of the equipment or process to be controlled, that exerts direct control over the process). The protocol functions in the presence of network latency, overcomes errors caused by missed dynamic keys, and defeats attempts by unauthorized remote users to gain control. The protocol is not suitable for real-time control, but is well suited for applications in which control latencies up to about 0.5 second are acceptable. The encryption scheme involves the use of both a dynamic and a private key, without any additional overhead that would degrade performance. The dynamic key is embedded in the equipment- or process-monitor data packets sent out by the controlled computer: in other words, the dynamic key is a subset of the data in each such data packet. The controlled computer maintains a history of the last 3 to 5 data packets for use in decrypting incoming control commands. In addition, the controlled computer records a private key (password) that is given to the remote computer. The encrypted incoming command is permuted by both the dynamic and private key. A person who records the command data in a given packet for hostile purposes cannot use that packet after the public key expires (typically within 3 seconds). Even a person in possession of an unauthorized copy of the command/remote-display software cannot use that software in the absence of the password. The use of a dynamic key embedded in the outgoing data makes the central-processing unit overhead very small. The use of a National Instruments DataSocket(TradeMark) (or equivalent) protocol or the User Datagram Protocol makes it possible to obtain reasonably short response times: Typical response times in event-driven control, using packets sized .300 bytes, are <0.2 second for commands issued from locations anywhere on Earth. The protocol requires that control commands represent absolute values of controlled parameters (e.g., a specified temperature), as distinguished from changes in values of controlled parameters (e.g., a specified increment of temperature). Each command is issued three or more times to ensure delivery in crowded networks. The use of absolute-value commands prevents additional (redundant) commands from causing trouble. Because a remote controlling computer receives "talkback" in the form of data packets from the controlled computer, typically within a time interval < or =1 s, the controlling computer can re-issue a command if network failure has occurred. The controlled computer, the process or equipment that it controls, and any human operator(s) at the site of the controlled equipment or process should be equipped with safety measures to prevent damage to equipment or injury to humans. These features could be a combination of software, external hardware, and intervention by the human operator(s). The protocol is not fail-safe, but by adopting these safety measures as part of the protocol, one makes the protocol a robust means of controlling remote processes and equipment by use of typical office computers via intranets and/or the Internet.

Lineberger, Lewis↗

The abnormally weighting energy hypothesis: the missing link between dark matter and dark energy

We generalize tensor-scalar theories of gravitation by the introduction of an 'abnormally weighting' type of energy. This theory of tensor-scalar anomalous gravity is based on a relaxation of the weak equivalence principle that is currently restricted to ordinary visible matter only. As a consequence, the mechanism of convergence toward general relativity is modified and produces cosmic acceleration naturally as an inescapable gravitational feedback induced by the mass variation of some invisible sector. The cosmological implications of this new theoretical framework are studied. From the Hubble diagram cosmological test alone, this theory provides estimates of the amount of baryons and dark matter in the Universe that are consistent with the independent cosmological tests of the cosmic microwave background and big bang nucleosynthesis. Cosmic coincidence is naturally achieved from an equally natural assumption on the amplitude of the scalar coupling strength. Finally, from the adequacy for supernovae data, we derive a new intriguing relation between the space-time dependences of the gravitational coupling and the dark matter mass, providing an example of a crucial constraint on microphysics from cosmology. This provides glimpses of an enticing new symmetry between the visible and invisible sectors, namely that the scalar charges of visible and invisible matter are exactly opposite.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying Interfraction and Intrafraction Tumor Motion in Lung Stereotactic Body Radiotherapy Using Respiration-Correlated Cone Beam Computed Tomography

Purpose: Stereotactic body radiation therapy (SBRT) is an effective treatment for medically inoperable Stage I non-small-cell lung cancer. However, changes in the patient's breathing patterns during the course of SBRT may result in a geographic miss or an overexposure of healthy tissues to radiation. However, the precise extent of these changes in breathing pattern is not well known. We evaluated the inter- and intrafractional changes in tumor motion amplitude (DELTAM) over an SBRT course. Methods and Materials: Eighteen patients received image-guided SBRT delivered in three fractions; this therapy was done with abdominal compression in four patients. For each fraction, cone beam computed tomography (CBCT) was performed for tumor localization (+- 3-mm tolerance) and then repeated to confirm geometric accuracy. Additional CBCT images were acquired at the midpoint and end of each SBRT fraction. Respiration-correlated CBCT (rcCBCT) reconstructions allowed retrospective assessment of inter- and intrafractional DELTAM by a comparison of tumor displacements in all four-dimensional CT and rcCBCT scans. The DELTAM was measured in mediolateral, superior-inferior, and anterior-posterior directions. Results: A total of 201 rcCBCT images were analyzed. The mean time from localization of the tumor to the end-fraction CBCT was 35 +- 7 min. Compared with the motion recorded on four-dimensional CT, the mean DELTAM was 0.4, 1.0, and 0.4 mm, respectively, in the mediolateral, superior-inferior, and anterior-posterior directions. On treatment, the observed DELTAM was, on average, <1 mm; no DELTAM was statistically different with respect to the initial rcCBCT. However, patients in whom abdominal compression was used showed a statistically significant difference (p < 0.05) in the variance of DELTAM with respect to the initial rcCBCT in the superior-inferior direction. Conclusions: The inter- and intrafractional DELTAM that occur during a course of lung SBRT are small. However, abdominal compression causes larger variations in the time spent on the treatment couch and in the inter- and intrafractional DELTAM values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing the diffuse baryon distribution with the lensing-tSZ cross-correlation

Approximately half of the Universe's baryons are in a form that has been hard to detect directly. However, the missing component can be traced through the cross-correlation of the thermal Sunyaev-Zeldovich (tSZ) effect with weak gravitational lensing. We build a model for this correlation and use it to constrain the extended baryon component, employing data from the Canada France Hawaii Lensing Survey and the Planck satellite. The measured correlation function is consistent with an isothermal β-model for the halo gas pressure profile, and the 1- and 2-halo terms are both detected at the 4σ level. In addition, we measure the hydrostatic mass bias (1−b)=0.79{sup +0.07}{sub −0.10}, which is consistent with numerical simulation results and the constraints from X-ray observations. The effective temperature of the gas is found to be in the range (7×10{sup 5}–3 ×10{sup 8}) K, with approximately 50% of the baryons appearing to lie beyond the virial radius of the halos, consistent with current expectations for the warm-hot intergalactic medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Using compressive sensing to recover images from PET scanners with partial detector rings

Purpose: Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors’ aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. Methods: A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CS model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 °, 90 °, 180 °, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. Results: For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. Conclusions: CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.

60 APPLIED LIFE SCIENCES↗

The anomaly of the CMB power with the latest Planck data

Abstract The lack of power anomaly is an unexpected feature observed at large angular scales in the maps of Cosmic Microwave Background (CMB) produced by the COBE, WMAP andPlancksatellites. This signature, which consists in a missing of power with respect to that predicted by the ΛCDM model, might hint at a new cosmological phase before the standard inflationary era.The main point of this paper is taking into account the latestPlanckpolarisation data to investigate how the CMB polarisation improves the understanding of this feature. With this aim, we apply to the latestPlanckdata, both PR3 (2018) and PR4 (2020) releases, a new class of estimators capable of evaluating this anomaly by considering temperature and polarisation data both separately and in a jointly way. This is the first time that the PR4 dataset has been used to study this anomaly. To critically evaluate this feature, taking into account the residuals of known systematic effects present in thePlanckdatasets, we analyse the cleaned CMB maps using different combinations of sky masks, harmonic range and binning on the CMB multipoles.Our analysis shows that the estimator based only on temperature data confirms the presence of a lack of power with a lower-tail-probability (LTP), depending on the component separation method, ≤ 0.33% and ≤ 1.76% for PR3 and PR4, respectively. To our knowledge, the LTP≤ 0.33% for the PR3 dataset is the lowest one present in the literature obtained fromPlanck2018 data, considering thePlanckconfidence mask. We find significant differences between these two datasets when polarisation is taken into account most likely due to a different level of systematics. Especially, the analysis with PR3 data, unlike that with PR4, seems to point towards a lack of power at large scales also for polarisation.Moreover, we also show that for the PR3 dataset the inclusion of the subdominant polarisation information provides estimates that are less likely accepted in a ΛCDM cosmological model than the only-temperature analysis over the entire harmonic-range considered. In particular, at ℓ max = 26, we found that no simulation has a value as low as the data for all the pipelines.

Astronomy & Astrophysics↗

Monitoring Based Commissioning: Benchmarking Analysis of 24 UC/CSU/IOU Projects

Buildings rarely perform as intended, resulting in energy use that is higher than anticipated. Building commissioning has emerged as a strategy for remedying this problem in non-residential buildings. Complementing traditional hardware-based energy savings strategies, commissioning is a 'soft' process of verifying performance and design intent and correcting deficiencies. Through an evaluation of a series of field projects, this report explores the efficacy of an emerging refinement of this practice, known as monitoring-based commissioning (MBCx). MBCx can also be thought of as monitoring-enhanced building operation that incorporates three components: (1) Permanent energy information systems (EIS) and diagnostic tools at the whole-building and sub-system level; (2) Retro-commissioning based on the information from these tools and savings accounting emphasizing measurement as opposed to estimation or assumptions; and (3) On-going commissioning to ensure efficient building operations and measurement-based savings accounting. MBCx is thus a measurement-based paradigm which affords improved risk-management by identifying problems and opportunities that are missed with periodic commissioning. The analysis presented in this report is based on in-depth benchmarking of a portfolio of MBCx energy savings for 24 buildings located throughout the University of California and California State University systems. In the course of the analysis, we developed a quality-control/quality-assurance process for gathering and evaluating raw data from project sites and then selected a number of metrics to use for project benchmarking and evaluation, including appropriate normalizations for weather and climate, accounting for variations in central plant performance, and consideration of differences in building types. We performed a cost-benefit analysis of the resulting dataset, and provided comparisons to projects from a larger commissioning 'Meta-analysis' database. A total of 1120 deficiency-intervention combinations were identified in the course of commissioning the projects described in this report. The most common location of deficiencies was in HVAC equipment (65% of sites), followed by air-handling and distributions systems (59%), cooling plant (29%), heating plants (24%), and terminal units (24%). The most common interventions were adjusting setpoints, modifying sequences of operations, calibration, and various mechanical fixes (each done in about two-thirds of the sites). The normalized rate of occurrence of deficiencies and corresponding interventions ranged from about 0.1/100ksf to 10/100ksf, depending on the issue. From these interventions flowed significant and highly cost-effective energy savings For the MBCx cohort, source energy savings of 22 kBTU/sf-year (10%) were achieved, with a range of 2% to 25%. Median electricity savings were 1.9 kWh/sf-year (9%), with a range of 1% to 17%. Peak electrical demand savings were 0.2 W/sf-year (4%), with a range of 3% to 11%. The aggregate commissioning cost for the 24 projects was $2.9 million. We observed a range of normalized costs from $0.37 to 1.62/sf, with a median value of $1.00/sf for buildings that implemented MBCx projects. Per the program design, monitoring costs as a percentage of total costs are significantly higher in MBCx projects (median value 40%) than typical commissioning projects included in the Meta-analysis (median value of 2% in the commissioning database). Half of the projects were in buildings containing complex and energy-intensive laboratory space, with higher associated costs. Median energy cost savings were $0.25/sf-year, for a median simple payback time of 2.5 years. Significant and cost-effective energy savings were thus obtained. The greatest absolute energy savings and shortest payback times were achieved in laboratory-type facilities. While impacts varied from project to project, on a portfolio basis we find MBCx to be a highly cost-effective means of obtaining significant program-level energy savings across a variety of building types. Energy savings are expected to be more robust and persistent for MBCx projects than for conventionally commissioned ones. Impacts of future programs can be maximized by benchmarking energy use and targeting the commissioning towards particularly energy-intensive facilities such as laboratories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A MULTIVARIATE FIT LUMINOSITY FUNCTION AND WORLD MODEL FOR LONG GAMMA-RAY BURSTS

It is proposed that the luminosity function, the rest-frame spectral correlations, and distributions of cosmological long-duration (Type-II) gamma-ray bursts (LGRBs) may be very well described as a multivariate log-normal distribution. This result is based on careful selection, analysis, and modeling of LGRBs' temporal and spectral variables in the largest catalog of GRBs available to date: 2130 BATSE GRBs, while taking into account the detection threshold and possible selection effects. Constraints on the joint rest-frame distribution of the isotropic peak luminosity (L{sub iso}), total isotropic emission (E{sub iso}), the time-integrated spectral peak energy (E{sub p,z}), and duration (T{sub 90,z}) of LGRBs are derived. The presented analysis provides evidence for a relatively large fraction of LGRBs that have been missed by the BATSE detector with E{sub iso} extending down to {approx}10{sup 49} erg and observed spectral peak energies (E{sub p} ) as low as {approx}5 keV. LGRBs with rest-frame duration T{sub 90,z} {approx}< 1 s or observer-frame duration T{sub 90} {approx}< 2 s appear to be rare events ({approx}< 0.1% chance of occurrence). The model predicts a fairly strong but highly significant correlation ({rho} = 0.58 {+-} 0.04) between E{sub iso} and E{sub p,z} of LGRBs. Also predicted are strong correlations of L{sub iso} and E{sub iso} with T{sub 90,z} and moderate correlation between L{sub iso} and E{sub p,z}. The strength and significance of the correlations found encourage the search for underlying mechanisms, though undermine their capabilities as probes of dark energy's equation of state at high redshifts. The presented analysis favors-but does not necessitate-a cosmic rate for BATSE LGRBs tracing metallicity evolution consistent with a cutoff Z/Z{sub Sun} {approx} 0.2-0.5, assuming no luminosity-redshift evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Omics-Driven Genome Annotation Refinement: Application across Yersiniae

Genome sequencing continues to be a rapidly evolving technology, yet most downstream aspects of genome annotation pipelines remain relatively stable or are even being abandoned. To date, the perceived value of manual curation for genome annotations is not offset by the real cost and time associated with the process. In order to balance the large number of sequences generated, the annotation process is now performed almost exclusively in an automated fashion for most genome sequencing projects. One possible way to reduce errors inherent to automated computational annotations is to apply data from 'omics' measurements (i.e. transcriptional and proteomic) to the un-annotated genome with a proteogenomic-based approach. This approach does require additional experimental and bioinformatics methods to include omics technologies; however, the approach is readily automatable and can benefit from rapid developments occurring in those research domains as well. The annotation process can be improved by experimental validation of transcription and translation and aid in the discovery of annotation errors. Here the concept of annotation refinement has been extended to include a comparative assessment of genomes across closely related species, as is becoming common in sequencing efforts. Transcriptomic and proteomic data derived from three highly similar pathogenic Yersiniae (Y. pestis CO92, Y. pestis pestoides F, and Y. pseudotuberculosis PB1/+) was used to demonstrate a comprehensive comparative omic-based annotation methodology. Peptide and oligo measurements experimentally validated the expression of nearly 40% of each strain's predicted proteome and revealed the identification of 28 novel and 68 previously incorrect protein-coding sequences (e.g., observed frameshifts, extended start sites, and translated pseudogenes) within the three current Yersinia genome annotations. Gene loss is presumed to play a major role in Y. pestis acquiring its niche as a virulent pathogen, thus the discovery of many translated pseudogenes underscores a need for functional analyses to investigate hypotheses related to divergence. Refinements included the discovery of a seemingly essential ribosomal protein, several virulence-associated factors, and a transcriptional regulator, among other proteins, most of which are annotated as hypothetical, that were missed during annotation.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of New Additions to OLI Software in Predicting Mercuric and Mercurous Species in Liquid Waste Operations

Speciation of mercury during the pretreatment steps of tank waste processing is critical to successful mercury removal prior to vitrification during Liquid Waste Operations (LWO) at SRS. OLI software has been used to predict mercury speciation and activity throughout LWO. The OLI software operates based on a thermodynamic framework called the Mixed Solvent Electrolyte (MSE) framework. The MSE framework allows prediction in theoretically infinitely dilute to concentrated mixtures (e.g., purely solute solutions). Before modification to the MSE framework databanks, certain critical mercury species were missing in the MSE databank, and some thermodynamic data needed to be updated for the OLI software to accurately predict mercury chemical species in SRS waste tanks. To better reflect streams across LWO, new mercury species were integrated into the MSE database. To evaluate the changes to the OLI MSE framework per the Technical Task Request (TTR) and the Task Technical and Quality Assurance Plan (TTQAP), waste stream compositions from Tanks 38, 43, and Tank 50 decontaminated salt solution (DSS) were used as model inputs. Models were developed and executed using both the old and new databases. Compositional analyses from caustic Tank 50 DSS and caustic Tanks 38 and 43 were used as the input streams. These streams represent the most comprehensive chemical data sets where both mercury and tank constituents were measured together. Results for Tank 50 DSS predict HgO as the predominant species in both databases. Both methyl and dimethyl Hg species are present when the new database is ‘on’ and are not predicted with the new database turned ‘off’. The new database predicts a greater amount of HgO and a greater fraction of it in the solid phase. Pourbaix diagrams (potential vs. pH) generated for each Tank 50 DSS were identical regardless of which database was used. Elemental Hg and HgO were predicted in the water stable region under basic conditions. Tanks 38 and 43 follow similar trends as the Tank 50 DSS models. Unlike Tanks 38 and 50 DSS, the Tank 43 Pourbaix plot shows a region of stability for an aqueous HgOHCO3 - species between approximately pH 7-11. In all streams, when MeHg+ is included in the inputs, the new database predicts aqueous MeHgOH as the dominant species. If elemental or dimethyl mercury is in the waste stream, the new database model predicts they are unchanged and remain in those states and quantities. Additionally, the total mercury values are reported for both the measured input data and the OLI output data for all considered tanks. The summary indicates that the percentage error between the measured and calculated values is less than 1% in all cases The reconciliations and generation of the Pourbaix diagrams for Tank 50 DSS took approximately ten times longer with the new database ‘on’. In addition, over the course of that time, models with the new database ‘on’ were more likely to crash or display an error. Some modest performance improvements were noted when modeling with an i7 processor versus an i5. An example error is found in Appendix A. Furthermore, Appendix B provides V&V for two chemical systems analyzed with the OLI software, results were satisfactory. It is recommended to utilize the new databases (i.e., HCO.ddb and SR-Hg.ddb) in future Savannah River Mission Completion applications of OLI to represent pseudo steady-state. Furthermore, the integration and utilization of the new databases (i.e., HCO.ddb and SR-Hg.ddb) in modeling applications (e.g., Aspen) is also recommended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular jet of IRAS 04166+2706

The molecular outflow from IRAS 04166+2706 was mapped with the Submillimeter Array at a 350 GHz continuum and CO J = 3-2 at an angular resolution of ∼1''. The field of view covers the central arcminute, which contains the inner four pairs of knots of the molecular jet. On the channel map, conical structures are clearly present in the low-velocity range (|V – V {sub 0}| < 10 km s{sup –1}), and the highly collimated knots appear in the extremely high velocity range (50 >|V – V {sub 0}| > 30 km s{sup –1}). The higher angular resolution of ∼1'' reveals the first blue-shifted knot (B1) that was missing in previous Plateau de Bure Interferometer observation of Santiago-García et al. at an offset of ∼6'' to the northeast of the central source. This identification completes the symmetric sequence of knots in both the blue- and red-shifted lobes of the outflow. The innermost knots R1 and B1 have the highest velocities within the sequence. Although the general features appear to be similar to previous CO J = 2-1 images in Santiago-García et al., the emission in CO J = 3-2 almost always peaks further away from the central source than that of CO J = 2-1 in the red-shifted lobe of the channel maps. This gives rise to a gradient in the line-ratio map of CO J = 3-2/J = 2-1 from head to tail within a knot. A large velocity gradient analysis suggests that the differences may reflect a higher gas kinetic temperature at the head. We also explore possible constraints imposed by the nondetection of SiO J = 8-7.

79 ASTRONOMY AND ASTROPHYSICS↗

A region-appearance-based adaptive variational model for 3D liver segmentation

Purpose: Liver segmentation from computed tomography images is a challenging task owing to pixel intensity overlapping, ambiguous edges, and complex backgrounds. The authors address this problem with a novel active surface scheme, which minimizes an energy functional combining both edge- and region-based information. Methods: In this semiautomatic method, the evolving surface is principally attracted to strong edges but is facilitated by the region-based information where edge information is missing. As avoiding oversegmentation is the primary challenge, the authors take into account multiple features and appearance context information. Discriminative cues, such as multilayer consecutiveness and local organ deformation are also implicitly incorporated. Case-specific intensity and appearance constraints are included to cope with the typically large appearance variations over multiple images. Spatially adaptive balancing weights are employed to handle the nonuniformity of image features. Results: Comparisons and validations on difficult cases showed that the authors’ model can effectively discriminate the liver from adhering background tissues. Boundaries weak in gradient or with no local evidence (e.g., small edge gaps or parts with similar intensity to the background) were delineated without additional user constraint. With an average surface distance of 0.9 mm and an average volume overlap of 93.9% on the MICCAI data set, the authors’ model outperformed most state-of-the-art methods. Validations on eight volumes with different initial conditions had segmentation score variances mostly less than unity. Conclusions: The proposed model can efficiently delineate ambiguous liver edges from complex tissue backgrounds with reproducibility. Quantitative validations and comparative results demonstrate the accuracy and efficacy of the model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Classifying thermodynamic cloud phase using machine learning models

Vertically resolved thermodynamic cloud-phase classifications are essential for studies of atmospheric cloud and precipitation processes. The Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Thermodynamic Cloud Phase (THERMOCLDPHASE) value-added product (VAP) uses a multi-sensor approach to classify the thermodynamic cloud phase by combining lidar backscatter and depolarization, radar reflectivity, Doppler velocity, spectral width, microwave-radiometer-derived liquid water path, and radiosonde temperature measurements. The measured pixels are classified as ice, snow, mixed phase, liquid (cloud water), drizzle, rain, and liq_driz (liquid+drizzle). We use this product as the ground truth to train three machine learning (ML) models to predict the thermodynamic cloud phase from multi-sensor remote sensing measurements taken at the ARM North Slope of Alaska (NSA) observatory: a random forest (RF), a multi-layer perceptron (MLP), and a convolutional neural network (CNN) with a U-Net architecture. Evaluations against the outputs of the THERMOCLDPHASE VAP with 1 year of data show that the CNN outperforms the other two models, achieving the highest test accuracy, F1 score, and mean intersection over union (IOU). Analysis of ML confidence scores shows that ice, rain, and snow have higher confidence scores, followed by liquid, while mixed, drizzle, and liq_driz have lower scores. Feature importance analysis reveals that the mean Doppler velocity and vertically resolved temperature are the most influential data streams for ML thermodynamic cloud-phase predictions. Lidar measurements exhibit lower feature importance due to rapid signal attenuation caused by the frequent presence of persistent low-level clouds at the NSA site. The ML models' generalization capacity is further evaluated by applying them at another Arctic ARM site in Norway using data taken during the ARM Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) field campaign. The models demonstrated similar performance to that observed at the NSA site. Finally, we evaluate the ML models' response to simulated instrument outages and signal degradation and show that a CNN U-Net model trained with input channel dropouts performs better when input fields are missing.

ARM Aerial Facility↗

Smisc - A collection of miscellaneous functions

A collection of functions for statistical computing and data manipulation. These include routines for rapidly aggregating heterogeneous matrices, manipulating file names, loading R objects, sourcing multiple R files, formatting datetimes, multi-core parallel computing, stream editing, specialized plotting, etc. Smisc-package A collection of miscellaneous functions allMissing Identifies missing rows or columns in a data frame or matrix as.numericSilent Silent wrapper for coercing a vector to numeric comboList Produces all possible combinations of a set of linear model predictors cumMax Computes the maximum of the vector up to the current index cumsumNA Computes the cummulative sum of a vector without propogating NAs d2binom Probability functions for the sum of two independent binomials dataIn A flexible way to import data into R. dbb The Beta-Binomial Distribution df2list Row-wise conversion of a data frame to a list dfplapply Parallelized single row processing of a data frame dframeEquiv Examines the equivalence of two dataframes or matrices dkbinom Probability functions for the sum of k independent binomials factor2character Converts all factor variables in a dataframe to character variables findDepMat Identify linearly dependent rows or columns in a matrix formatDT Converts date or datetime strings into alternate formats getExtension Filename manipulations: remove the extension or path, extract the extension or path getPath Filename manipulations: remove the extension or path, extract the extension or path grabLast Filename manipulations: remove the extension or path, extract the extension or path ifelse1 Non-vectorized version of ifelse integ Simple numerical integration routine interactionPlot Two-way Interaction Plot with Error Bar linearMap Linear mapping of a numerical vector or scalar list2df Convert a list to a data frame loadObject Loads and returns the object(s) in an ".Rdata" file more Display the contents of a file to the R terminal movAvg2 Calculate the moving average using a 2-sided window openDevice Opens a graphics device based on the filename extension p2binom Probability functions for the sum of two independent binomials padZero Pad a vector of numbers with zeros parseJob Parses a collection of elements into (almost) equal sized groups pbb The Beta-Binomial Distribution pcbinom A continuous version of the binomial cdf pkbinom Probability functions for the sum of k independent binomials plapply Simple parallelization of lapply plotFun Plot one or more functions on a single plot PowerData An example of power data pvar Prints the name and value of one or more objects qbb The Beta-Binomial Distribution rbb And numerous others (space limits reporting).

Landon Sego, PNNL↗

Smisc - A collection of miscellaneous functions

A collection of functions for statistical computing and data manipulation. These include routines for rapidly aggregating heterogeneous matrices, manipulating file names, loading R objects, sourcing multiple R files, formatting datetimes, multi-core parallel computing, stream editing, specialized plotting, etc. Smisc-package A collection of miscellaneous functions allMissing Identifies missing rows or columns in a data frame or matrix as.numericSilent Silent wrapper for coercing a vector to numeric comboList Produces all possible combinations of a set of linear model predictors cumMax Computes the maximum of the vector up to the current index cumsumNA Computes the cummulative sum of a vector without propogating NAs d2binom Probability functions for the sum of two independent binomials dataIn A flexible way to import data into R. dbb The Beta-Binomial Distribution df2list Row-wise conversion of a data frame to a list dfplapply Parallelized single row processing of a data frame dframeEquiv Examines the equivalence of two dataframes or matrices dkbinom Probability functions for the sum of k independent binomials factor2character Converts all factor variables in a dataframe to character variables findDepMat Identify linearly dependent rows or columns in a matrix formatDT Converts date or datetime strings into alternate formats getExtension Filename manipulations: remove the extension or path, extract the extension or path getPath Filename manipulations: remove the extension or path, extract the extension or path grabLast Filename manipulations: remove the extension or path, extract the extension or path ifelse1 Non-vectorized version of ifelse integ Simple numerical integration routine interactionPlot Two-way Interaction Plot with Error Bar linearMap Linear mapping of a numerical vector or scalar list2df Convert a list to a data frame loadObject Loads and returns the object(s) in an ".Rdata" file more Display the contents of a file to the R terminal movAvg2 Calculate the moving average using a 2-sided window openDevice Opens a graphics device based on the filename extension p2binom Probability functions for the sum of two independent binomials padZero Pad a vector of numbers with zeros parseJob Parses a collection of elements into (almost) equal sized groups pbb The Beta-Binomial Distribution pcbinom A continuous version of the binomial cdf pkbinom Probability functions for the sum of k independent binomials plapply Simple parallelization of lapply plotFun Plot one or more functions on a single plot PowerData An example of power data pvar Prints the name and value of one or more objects qbb The Beta-Binomial Distribution rbb And numerous others (space limits reporting).

Landon Sego, PNNL↗

XMM-NEWTON OBSERVATIONS OF A COMPLETE SAMPLE OF OPTICALLY SELECTED TYPE 2 SEYFERT GALAXIES

The majority of active galactic nuclei (AGNs) suffer from significant obscuration by surrounding dust and gas. The penetrating power and sensitivity of hard X-ray observations allow obscured AGNs to be probed out to high redshifts. However, X-ray surveys in the 2-10 keV band will miss the most heavily obscured AGNs in which the absorbing column density exceeds approx10{sup 24} cm{sup -2} (the Compton-thick AGN). It is, therefore, vital to know the fraction of AGNs that are missed in such X-ray surveys and to determine if these AGNs represent some distinct population in terms of the fundamental properties of AGNs and/or their host galaxies. In this paper, we present the analysis of XMM-Newton X-ray data for a complete sample of 17 low-redshift Type 2 Seyfert galaxies chosen from the Sloan Digital Sky Survey based solely on the high observed flux of the [O III]lambda5007 emission line. This line is formed in the narrow-line region hundreds of parsecs away from the central engine. Thus, unlike the X-ray emission, it is not affected by obscuration due to the torus surrounding the black hole. It therefore provides a useful isotropic indicator of the AGN luminosity. As additional indicators of the intrinsic AGN luminosity, we use the Spitzer Space Telescope to measure the luminosities of the mid-infrared continuum and the [O IV] 25.89 mum narrow emission line. We then use the ratio of the 2-10 keV X-ray luminosity to the [O III], [O IV], and mid-infrared luminosities to assess the amount of X-ray obscuration and to distinguish between Compton-thick and Compton-thin objects. The various diagnostics of AGN luminosity with heavily obscured hard X-ray emission are in broad agreement. We find that the majority of the sources suffer significant amounts of obscuration: the observed 2-10 keV emission is depressed by more than an order of magnitude in 11 of the 17 cases (as expected for Compton-thick sources). Thus, surveys in the rest-frame 2-10 keV band will be significantly incomplete for obscured AGNs. We find a strong inverse correlation between the ratio of the 2-10 keV X-ray and [O III] (or [O IV] or mid-IR) fluxes and the equivalent width of the 6.4 keV Fe Kalpha line. This demonstrates that the weak hard X-ray continuum emission is due to obscuration (rather than due to intrinsically weak emission). In several cases, the large amount of obscuration is not consistent with the values of absorbing column density derived from simple spectral fits to the data. We run simulations of a more physically realistic model with partial covering of the X-ray source plus Compton scattering, and show that such models are consistent with the data. We show that the distribution of obscuration in the 2-10 keV band in our sample is similar to what is seen in samples selected in the Swift BAT energy band (14-195 keV). This implies that the BAT surveys do recover a significant fraction of the local population of Compton-thick AGNs. Finally, we find no relationship between the amount of X-ray obscuration and the other properties of the AGN and its host galaxy. Hence, Compton-thick and Compton-thin sources do not seem to trace distinct populations.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring Tropospheric Winds from Space Using a Coherent Doppler Lidar Technique

The global measurement of tropospheric wind profiles has been cited by the operational meteorological community as the most important missing element in the present and planned observing system. The most practical and economical method for obtaining this measurement is from low earth orbit, utilizing a Doppler lidar (laser radar) technique. Specifically, this paper will describe the coherent Doppler wind lidar (CDWL) technique, the design and progress of a current space flight project to fly such a system on the Space Shuttle, and plans for future flights of similar instruments. The SPARCLE (SPAce Readiness Coherent Lidar Experiment) is a Shuttle-based instrument whose flight is targeted for March, 2001. The objectives of SPARCLE are three-fold: Confirm that the coherent Doppler lidar technique can measure line-of-sight winds to within 1-2 m/s accuracy; Collect data to permit validation and improvement of instrument performance models to enable better design of future missions; and Collect wind and backscatter data for future mission optimization and for atmospheric studies. These objectives reflect the nature of the experiment and its program sponsor, NASA's New Millennium Program. The experiment is a technology validation mission whose primary purpose is to provide a space flight validation of this particular technology. (It should be noted that the CDWL technique has successfully been implemented from ground-based and aircraft-based platforms for a number of years.) Since the conduct of the SPARCLE mission is tied to future decisions on the choice of technology for free-flying, operational missions, the collection of data is intrinsically tied to the validation and improvement of instrument performance models that predict the sensitivity and accuracy of any particular present or future instrument system. The challenges unique to space flight for an instrument such as SPARCLE and follow-ons include: Obtaining the required lidar sensitivity from the long distance of orbit height to the lower atmosphere; Maintaining optical alignments after launch to orbit, and during operations in "microgravity"; Obtaining pointing knowledge of sufficient accuracy to remove the speed of the spacecraft (and the rotating Earth) from the measurements; Providing sufficient power (not a problem on the Shuttle) and cooling to the instrument. The paper will describe the status and challenges of the SPARCLE project, the value of obtaining wind data from orbit, and will present a roadmap to future instruments for scientific research and operational meteorology.

Miller, Timothy L.↗

Quantitative Representativeness and Constituency of the Long-Term Agroecosystem Research Network and Analysis of Complementarity with Existing Ecological Networks

Abstract Studies conducted at sites across ecological research networks usually strive to scale their results to larger areas, trying to reach conclusions that are valid throughout larger enclosing regions. Network representativeness and constituency can show how well conditions at sampling locations represent conditions also found elsewhere and can be used to help scale-up results over larger regions. Multivariate statistical methods have been used to design networks and select sites that optimize regional representation, thereby maximizing the value of datasets and research. However, in networks created from already established sites, an immediate challenge is to understand how well existing sites represent the range of environments in the whole area of interest. We performed an analysis to show how well sites in the USDA Long-Term Agroecosystem Research (LTAR) Network represent all agricultural working lands within the conterminous United States (CONUS). Our analysis of 18 LTAR sites, based on 15 climatic and edaphic characteristics, produced maps of representativeness and constituency. Representativeness of the LTAR sites was quantified through an exhaustive pairwise Euclidean distance calculation in multivariate space, between the locations of experiments within each LTAR site and every 1 km cell across the CONUS. Network representativeness is from the perspective of all CONUS locations, but we also considered the perspective from each LTAR site. For every LTAR site, we identified the region that is best represented by that particular site—its constituency—as the set of 1 km grid locations best represented by the environmental drivers at that particular LTAR site. Representativeness shows how well the combination of characteristics at each CONUS location was represented by the LTAR sites’ environments, while constituency shows which LTAR site was the closest match for each location. LTAR representativeness was good across most of the CONUS. Representativeness for croplands was higher than for grazinglands, probably because croplands have more specific environmental criteria. Constituencies resemble ecoregions but have their environmental conditions “centered” on those at particular existing LTAR sites. Constituency of LTAR sites can be used to prioritize the locations of experimental research at or even within particular sites, or to identify the extents that can likely be included when generalizing knowledge across larger regions of the CONUS. Sites with a large constituency have generalist environments, while those with smaller constituency areas have more specialized environmental combinations. These “specialist” sites are the best representatives for smaller, more unusual areas. The potential of sharing complementary sites from the Long-Term Ecological Research (LTER) Network and the National Ecological Observatory Network (NEON) to boost representativeness was also explored. LTAR network representativeness would benefit from borrowing several NEON sites and the Sevilleta LTER site. Later network additions must include such specialist sites that are targeted to represent unique missing environments. While this analysis exhaustively considered principal environmental characteristics related to production on working lands, we did not consider the focal agronomic systems under study, or their socio-economic context.

54 ENVIRONMENTAL SCIENCES↗