Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Evidence for Quasi-Periodic X-ray Dips from an ULX: Implications for the Binary Motion and the Orbital Inclination

We report results from long-term X-ray (0.3-8.0 keY) monitoring of the ultraluminous X-ray source NGC 5408 X-1 with the Swift/X-Ray Telescope. Our primary results are: (1) the discovery of quasi-periodic dips in the X-ray intensity that recur on average every 243 days, (2) the detection of an energy-dependent (variability amplitude decreases with increasing energy), quasi-sinusoidal X-ray modulation with a period of 112.6 +/- 4 days the amplitude of which decreases during the second half of the light curve and (3) energy spectral evidence for an increase in photoelectric absorption during the last continuous segment of the data, possibly due to a change in the ionization state of the circumbinary material. We interpret the X-ray modulations in the context of binary motion in analogy to that seen in high-inclination low-mass X-ray binaries. If correct, this implies that NGC 5408 X-1 is in a binary with an orbital period of 243 +/- 23 days in contrast to the 115.5 day quasi-sinusoidal period previously reported. In addition, if the X-ray modulation is caused by vertically structured obscuring material in the accretion disk (similar to the phenomenon of dipping LMXBs), this would imply a high value for the inclination of the orbit. A comparison with estimates from accreting X-ray binaries suggests an inclination approx > 60 deg. We note that, in principle, a precessing accretion disk could also produce the observed X-ray modulations.

Pasham, Dheeraj R.↗

Electron kinetic effects on optical diagnostics in fusion plasmas

At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP) and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. We calculate electron thermal corrections to the interferometric phase and polarization state of an EM wave propagating along tangential and poloidal chords (Faraday and Cotton-Mouton polarimetry) and perform analysis of the degree of polarization for incoherent TS. The precision of the previous lowest order linear in τ = T{sub e}/m{sub e}c{sup 2} model may be insufficient; we present a more precise model with τ{sup 2}-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH and RF current drive effects. The classical problem of degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of T{sup e} measurement relevant to ITER operational scenarios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

From following edges to pursuing objects

Primates can generate accurate, smooth eye-movement responses to moving target objects of arbitrary shape and size, even in the presence of complex backgrounds and/or the extraneous motion of non-target objects. Most previous studies of pursuit have simply used a spot moving over a featureless background as the target and have thus neglected critical issues associated with the general problem of recovering object motion. Visual psychophysicists and theoreticians have shown that, for arbitrary objects with multiple features at multiple orientations, object-motion estimation for perception is a complex, multi-staged, time-consuming process. To examine the temporal evolution of the motion signal driving pursuit, we recorded the tracking eye movements of human observers to moving line-figure diamonds. We found that pursuit is initially biased in the direction of the vector average of the motions of the diamond's line segments and gradually converges to the true object-motion direction with a time constant of approximately 90 ms. Furthermore, transient blanking of the target during steady-state pursuit induces a decrease in tracking speed, which, unlike pursuit initiation, is subsequently corrected without an initial direction bias. These results are inconsistent with current models in which pursuit is driven by retinal-slip error correction. They demonstrate that pursuit models must be revised to include a more complete visual afferent pathway, which computes, and to some extent latches on to, an accurate estimate of object direction over the first hundred milliseconds or so of motion.

NASA Discipline Neuroscience↗

Image-Guided Radiotherapy for Left-Sided Breast Cancer Patients: Geometrical Uncertainty of the Heart

Purpose: To quantify the geometrical uncertainties for the heart during radiotherapy treatment of left-sided breast cancer patients and to determine and validate planning organ at risk volume (PRV) margins. Methods and Materials: Twenty-two patients treated in supine position in 28 fractions with regularly acquired cone-beam computed tomography (CBCT) scans for offline setup correction were included. Retrospectively, the CBCT scans were reconstructed into 10-phase respiration correlated four-dimensional scans. The heart was registered in each breathing phase to the planning CT scan to establish the respiratory heart motion during the CBCT scan ({sigma}{sub resp}). The average of the respiratory motion was calculated as the heart displacement error for a fraction. Subsequently, the systematic ({Sigma}), random ({sigma}), and total random ({sigma}{sub tot}={radical}({sigma}{sup 2}+{sigma}{sub resp}{sup 2})) errors of the heart position were calculated. Based on the errors a PRV margin for the heart was calculated to ensure that the maximum heart dose (D{sub max}) is not underestimated in at least 90% of the cases (M{sub heart} = 1.3{Sigma}-0.5{sigma}{sub tot}). All analysis were performed in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions with respect to both online and offline bony anatomy setup corrections. The PRV margin was validated by accumulating the dose to the heart based on the heart registrations and comparing the planned PRV D{sub max} to the accumulated heart D{sub max}. Results: For online setup correction, the cardiac geometrical uncertainties and PRV margins were N-Ary-Summation = 2.2/3.2/2.1 mm, {sigma} = 2.1/2.9/1.4 mm, and M{sub heart} = 1.6/2.3/1.3 mm for LR/CC/AP, respectively. For offline setup correction these were N-Ary-Summation = 2.4/3.7/2.2 mm, {sigma} = 2.9/4.1/2.7 mm, and M{sub heart} = 1.6/2.1/1.4 mm. Cardiac motion induced by breathing was {sigma}{sub resp} = 1.4/2.9/1.4 mm for LR/CC/AP. The PRV D{sub max} underestimated the accumulated heart D{sub max} for 9.1% patients using online and 13.6% patients using offline bony anatomy setup correction, which validated that PRV margin size was adequate. Conclusion: Considerable cardiac position variability relative to the bony anatomy was observed in breast cancer patients. A PRV margin can be used during treatment planning to take these uncertainties into account.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Autoresonant excitation of nonlinear beam motion in storage rings

Understanding and controlling of nonlinear beam dynamics are essential to the performance of storage ring light sources. In order to measure and correct limitations due to nonlinear beam dynamics, an effective method is needed to excite the beam oscillation to large amplitudes. Autoresonance is a method that enables the control of the amplitude of a driven nonlinear oscillator by sweeping the frequency of the driver. In this study, autoresonant excitation of beam transverse oscillations in storage rings is studied. The threshold of the drive amplitude for autoresonance is theoretically obtained, for cases with or without damping. The results are in good agreement with simulations for a simple storage ring model, as well as for models of actual storage rings. Application of the theory to experimental data on the SPEAR3 storage ring also validates the results

43 PARTICLE ACCELERATORS↗

Inter- and Intrafraction Uncertainty in Prostate Bed Image-Guided Radiotherapy

Purpose: The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. Methods and Materials: In this prospective study, 14 patients underwent adjuvant or salvage radiotherapy to the prostate bed under image guidance using linac-based kilovoltage cone-beam CT (kV-CBCT). Inter- and intrafraction uncertainty/motion was assessed by offline analysis of three consecutive daily kV-CBCT images of each patient: (1) after initial setup to skin marks, (2) after correction for positional error/immediately before radiation treatment, and (3) immediately after treatment. Results: The magnitude of interfraction PBM was 2.1 mm, and intrafraction PBM was 0.4 mm. The maximum inter- and intrafraction prostate bed motion was primarily in the anterior-posterior direction. Margins of at least 3-5 mm with IGRT and 4-7 mm without IGRT (aligning to skin marks) will ensure 95% of the prescribed dose to the clinical target volume in 90% of patients. Conclusions: PBM is a predominant source of intrafraction error compared with setup error and has implications for appropriate PTV margins. Based on inter- and estimated intrafraction motion of the prostate bed using pre- and post-kV-CBCT images, CBCT IGRT to correct for day-to-day variances can potentially reduce CTV-PTV margins by 1-2 mm. CTV-PTV margins for prostate bed treatment in the IGRT and non-IGRT scenarios are proposed; however, in cases with more uncertainty of target delineation and image guidance accuracy, larger margins are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An energy-conserving and asymptotic-preserving charged-particle orbit implicit time integrator for arbitrary electromagnetic fields

Here we present a new implicit asymptotic preserving time integration scheme for charged-particle orbit computation in arbitrary electromagnetic fields. The scheme is built on the Crank-Nicolson integrator and continues to recover full-orbit motion in the small time-step limit, but also recovers all the first-order guiding center drifts as well as the correct gyroradius when stepping over the gyration time-scale. In contrast to previous efforts in this direction, the new scheme also features exact energy conservation. In the derivation of the scheme, we find that a new numerical time-scale is introduced. This scale is analyzed and the resulting restrictions on time-step are derived. Based on this analysis, we develop an adaptive time-stepping strategy the respects these constraints while stepping over the gyration scale when physically justified. It is shown through numerical tests on single-particle motion that the scheme's energy conservation property results in tremendous improvements in accuracy, and that the scheme is able to transition smoothly between magnetized and unmagnetized regimes as a result of the adaptive time-stepping.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Density-Dependent Relations among Properties of Hadronic Matter and Applications to Hadron-Quark Stars

Density-dependent relations among the saturation properties of symmetric nuclear matter and hyperonic matter, and properties of hadron-(strange) quark stars are shown by applying the conserving nonlinear {sigma}-{omega}-{rho} hadronic mean-field theory. Nonlinear interactions are renormalized self-consistently as effective coupling constants, effective masses, and sources of equations of motion by maintaining thermodynamic consistency to the mean-field approximation. Effective masses and coupling constants at the saturation point of symmetric nuclear matter simultaneously determine the binding energy and saturation properties of hyperonic matter. The coupling constants expected from the hadronic mean-field model and SU(6) quark model for the vector coupling constants are compared by calculating masses of hadron-quark neutron stars. The nonlinear {sigma}-{omega}-{rho} mean-field approximation with vacuum fluctuation corrections and strange quark matter defined by the MIT-bag model were employed to examine properties of hadron-(strange) quark stars. We found that hadron-(strange) quark stars become more stable at high densities compared to pure hadronic and strange quark stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Limited Motion of the Prostate by Carefully Emptying the Rectum as Assessed by Daily MVCT Image Guidance with Helical Tomotherapy

Purpose: To assess setup and organ motion error by means of analysis of daily megavoltage computed tomography (MVCT) of patients treated with hypofractionated helical tomotherapy (71.4-74.2 Gy in 28 fractions). Methods and Materials: Data from 21 patients were analyzed. Patients were instructed to empty the rectum carefully before planning CT and every morning before therapy by means of a self-applied rectal enema. The position of the prostate was assessed by means of automatic bone matching (BM) with the planning kilovoltage CT (BM, setup error) followed by a direct visualization (DV) match on the prostate. Deviations between planning and therapy positions referred to BM and BM + DV were registered for the three main axes. In case of a full rectum at MVCT with evident shift of the prostate, treatment was postponed until after additional rectal emptying procedures; in this case, additional MVCT was performed before delivering the treatment. Data for 522 fractions were available; the impact of post-MVCT procedure was investigated for 17 of 21 patients (410 fractions). Results: Prostate motion relative to bony anatomy was limited. Concerning posterior-anterior shifts, only 4.9% and 2.7% of fractions showed deviation of 3 mm or greater of the prostate relative to BM without and with consideration of post-MVCT procedures, respectively. Interobserver variability for BM + DV match was within 0.8 mm (1 SD). Conclusions: Daily MVCT-based correction is feasible. The BM + DV matching was found to be consistent between operators. Rectal emptying using a daily enema is an efficient tool to minimize prostate motion, even for centers that have not yet implemented image-guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereographic Targeting in Prostate Radiotherapy: Speed and Precision by Daily Automatic Positioning Corrections Using Kilovoltage/Megavoltage Image Pairs

Purpose: A fully automated, fast, on-line prostate repositioning scheme using implanted markers, kilovoltage/megavoltage imaging, and remote couch movements has been developed and clinically applied. The initial clinical results of this stereographic targeting (SGT) method, as well as phantom evaluations, are presented. Methods and Materials: Using the SGT method, portal megavoltage images are acquired with the first two to six monitor units of a treatment beam, immediately followed by acquisition of an orthogonal kilovoltage image without gantry motion. The image pair is automatically analyzed to obtain the marker positions and three-dimensional prostate displacement and rotation. Remote control couch shifts are applied to correct for the displacement. The SGT performance was measured using both phantom images and images from 10 prostate cancer patients treated using SGT. Results: With phantom measurements, the accuracy of SGT was 0.5, 0.2, and 0.3 mm (standard deviation [SD]) for the left-right, craniocaudal, and anteroposterior directions, respectively, for translations and 0.5{sup o} (SD) for the rotations around all axes. Clinically, the success rate for automatic marker detection was 99.5%, and the accuracy was 0.3, 0.5 and 0.8 mm (SD) in the left-right, craniocaudal, and anteroposterior axes. The SDs of the systematic center-of-mass positioning errors ({sigma}) were reduced from 4.0 mm to <0.5 mm for all axes. The corresponding SD of the random ({sigma}) errors was reduced from 3.0 to <0.8 mm. These small residual errors were achieved with a treatment time extension of <1 min. Conclusion: Stereographic targeting yields systematic and random prostate positioning errors of <1 mm with <1 min of added treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Casimir effect within D=3+1 Maxwell-Chern-Simons electrodynamics

Within the framework of the (3+1)-dimensional Lorentz-violating extended electrodynamics including the CPT-odd Chern-Simons term, we consider the electromagnetic field between two parallel perfectly conducting plates. We find the one-particle eigenstates of such a field, as well as the implicit expression for the photon energy spectrum. We also show that the tachyon-induced vacuum instability is negligible when the separation between the plates is sufficiently small though finite. In order to find the leading Chern-Simons correction to the vacuum energy, we renormalize and evaluate the sum over all one-particle eigenstate energies using the two different methods, the zeta function technique and the transformation of the discrete sum into a complex plane integral via the residue theorem. The resulting correction to the Casimir force, which is attractive and quadratic in the Chern-Simons term, disagrees with the one obtained in [M. Frank and I. Turan, Phys. Rev. D 74, 033016 (2006)], using the misinterpreted equations of motion. Compared with experimental data, our result places a constraint on the absolute value of the Chern-Simons term.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mind Your Ps and Qs: The Interrelation between Period (P) and Mass-ratio (Q) Distributions of Binary Stars

We compile observations of early-type binaries identified via spectroscopy, eclipses, long-baseline interferometry, adaptive optics, common proper motion, etc. Each observational technique is sensitive to companions across a narrow parameter space of orbital periods P and mass ratios q = M{sub comp}/M {sub 1}. After combining the samples from the various surveys and correcting for their respective selection effects, we find that the properties of companions to O-type and B-type main-sequence (MS) stars differ among three regimes. First, at short orbital periods P ≲ 20 days (separations a ≲ 0.4 au), the binaries have small eccentricities e ≲ 0.4, favor modest mass ratios 〈q〉≈0.5, and exhibit a small excess of twins q > 0.95. Second, the companion frequency peaks at intermediate periods log P (days) ≈ 3.5 (a ≈ 10 au), where the binaries have mass ratios weighted toward small values q ≈ 0.2–0.3 and follow a Maxwellian “thermal” eccentricity distribution. Finally, companions with long orbital periods log P (days) ≈ 5.5–7.5 (a ≈ 200–5000 au) are outer tertiary components in hierarchical triples and have a mass ratio distribution across q ≈ 0.1–1.0 that is nearly consistent with random pairings drawn from the initial mass function. We discuss these companion distributions and properties in the context of binary-star formation and evolution. We also reanalyze the binary statistics of solar-type MS primaries, taking into account that 30% ± 10% of single-lined spectroscopic binaries likely contain white dwarf companions instead of low-mass stellar secondaries. The mean frequency of stellar companions with q > 0.1 and log P (days) < 8.0 per primary increases from 0.50 ± 0.04 for solar-type MS primaries to 2.1 ± 0.3 for O-type MS primaries. We fit joint probability density functions f(M{sub 1},q,P,e)≠f(M{sub 1})f(q)f(P)f(e) to the corrected distributions, which can be incorporated into binary population synthesis studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Piloted Simulator Evaluation Results of Flight Physics Based Stall Recovery Guidance

In recent studies, it has been observed that loss of control in flight is the most frequent primary cause of accidents. A significant share of accidents in this category can be remedied by upset prevention if possible, and by upset recovery if necessary, in this order of priorities. One of the most important upsets to be recovered from is stall. Recent accidents have shown that a correct stall recovery maneuver remains a big challenge in civil aviation, partly due to a lack of pilot training. A possible strategy to support the flight crew in this demanding context is calculating a recovery guidance signal, and showing this signal in an intuitive way on one of the cockpit displays, for example by means of the flight director. Different methods for calculating the recovery signal, one based on fast model predictive control and another using an energy based approach, have been evaluated in four relevant operational scenarios by experienced commercial as well as test pilots in the Vertical Motion Simulator at NASA Ames Research Center. Evaluation results show that this approach could be able to assist the pilots in executing a correct stall recovery maneuver.

Lombaerts, Thomas↗

Testing a satellite automatic nutation control system

Testing of a particular nutation control system for the synchronous meteorological satellite (SMS) is described. The test method and principles are applicable to nutation angle control for other satellites with similar requirements. During its ascent to synchronous orbit, a spacecraft like the SMS spins about its minimum-moment-of-inertia axis. An uncontrolled spacecraft in this state is unstable because torques due to fuel motion increase the nutation angle. However, the SMS is equipped with an automatic nutation control (ANC) system which will keep the nutation angle close to zero. Because correct operation of this system is critical to mission success, it was tested on an air-bearing table. The ANC system was mounted on the three-axis air-bearing table which was scaled to the SMS and equipped with appropriate sensors and thrusters. The table was spun up in an altitude chamber and nutation induced so that table motion simulated spacecraft motion. The ANC system was used to reduce the nutation angle. This dynamic test of the ANC system met all its objectives and provided confidence that the ANC system will control the SMS nutation angle.

Hrasiar, J. A.↗

Comoving Stars in Gaia DR1: An Abundance of Very Wide Separation Comoving Pairs

The primary sample of the Gaia Data Release 1 is the Tycho-Gaia Astrometric Solution (TGAS): ≈2 million Tycho-2 sources with improved parallaxes and proper motions relative to the initial catalog. This increased astrometric precision presents an opportunity to find new binary stars and moving groups. We search for high-confidence comoving pairs of stars in TGAS by identifying pairs of stars consistent with having the same 3D velocity using a marginalized likelihood ratio test to discriminate candidate comoving pairs from the field population. Although we perform some visualizations using (bias-corrected) inverse parallax as a point estimate of distance, the likelihood ratio is computed with a probabilistic model that includes the covariances of parallax and proper motions and marginalizes the (unknown) true distances and 3D velocities of the stars. We find 13,085 comoving star pairs among 10,606 unique stars with separations as large as 10 pc (our search limit). Some of these pairs form larger groups through mutual comoving neighbors: many of these pair networks correspond to known open clusters and OB associations, but we also report the discovery of several new comoving groups. Most surprisingly, we find a large number of very wide (>1 pc) separation comoving star pairs, the number of which increases with increasing separation and cannot be explained purely by false-positive contamination. Our key result is a catalog of high-confidence comoving pairs of stars in TGAS. We discuss the utility of this catalog for making dynamical inferences about the Galaxy, testing stellar atmosphere models, and validating chemical abundance measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Equations of state for the α and γ polymorphs of cyclotrimethylene trinitramine

Equations of state for the $α$ and $γ$ polymorphs of the energetic molecular crystal cyclotrimethylene trinitramine (RDX) have been developed from their Helmholtz free energies. In this work, the ion motion contribution to the Helmholtz free energy is represented by Debye models with density-dependent Debye temperatures that are parameterized to vibrational densities of states computed from dispersion-corrected density functional theory. By separating the vibrational density of states into low frequency modes of mainly lattice phonon character and high frequency modes of intramolecular character we were able to significantly improve the description of the heat capacity at low temperatures and the thermal contribution to the pressure. The ion motion contribution to the Helmholtz free energy of the high pressure $γ$ polymorph was constructed from that of the a polymorph to reproduce the temperature-independent transformation pressure seen experimentally. The static lattice energies for both polymorphs were constructed to reproduce published isothermal compression data. The equations of state have been applied to the prediction of the path of the principal Hugoniot in the equilibrium phase diagram.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum compositeness of gravity: black holes, AdS and inflation

Gravitational backgrounds, such as black holes, AdS, de Sitter and inflationary universes, should be viewed as composite of N soft constituent gravitons. It then follows that such systems are close to quantum criticality of graviton Bose-gas to Bose-liquid transition. Generic properties of the ordinary metric description, including geodesic motion or particle-creation in the background metric, emerge as the large-N limit of quantum scattering of constituent longitudinal gravitons. We show that this picture correctly accounts for physics of large and small black holes in AdS, as well as reproduces well-known inflationary predictions for cosmological parameters. However, it anticipates new effects not captured by the standard semi-classical treatment. In particular, we predict observable corrections that are sensitive to the inflationary history way beyond last 60 e-foldings. We derive an absolute upper bound on the number of e-foldings, beyond which neither de Sitter nor inflationary Universe can be approximated by a semi-classical metric. However, they could in principle persist in a new type of quantum eternity state. We discuss implications of this phenomenon for the cosmological constant problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Slender-body approach for computing second-order wave loads in the frequency domain

This work presents a slender-body approach to evaluate the second-order wave loads acting on a floating structure in the frequency domain. The approach is in the same spirit as the common use of Morison’s equation to approximate the wave loads without solving the radiation/diffraction problem. To do so, we employ Rainey’s equation, which can be seen as an extension of the inertial part of Morison’s equation to include nonlinear effects. We introduce modifications to Rainey’s formulation in order to evaluate wave kinematics at the mean body position instead of the original approach of considering instantaneous displacements. We also propose a simple approximation to partially account for wave scattering effects on the second-order loads based on the analytical solution of a surface-piercing bottom-mounted vertical circular cylinder. Though limited to structures composed of cylinders, this slender-body approach is orders of magnitude faster than computing second-order wave coefficients with a radiation/diffraction code. We implemented this approach for difference-frequency (slow drift) loads in an open-source frequency-domain floating wind turbine model. We present comparisons against results obtained with radiation/diffraction theory for three reference floating wind turbine designs: the OC3-Hywind spar, the OC4-DeepCwind semisubmersible, and the VolturnUS-S semisubmersible. In general, the results show that the proposed slender-body approach with the correction to approximate wave scattering effects provides useful estimations of the difference-frequency wave loads and the resulting motions of the floater.

17 WIND ENERGY↗