On the synthesis of suboptimal, inertia-wheel attitude control systems
Suboptimal attitude control system for Nimbus satellite using motor-driven inertia wheels as control torque source for three dimensional control
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Suboptimal attitude control system for Nimbus satellite using motor-driven inertia wheels as control torque source for three dimensional control
The Unitary Plan Wind Tunnel (UPWT) was modernized to improve performance, capability, productivity, and reliability. Automation systems were installed in all three UPWT tunnel legs and the Auxiliaries facility. Major improvements were made to the four control rooms, model support systems, main drive motors, and main drive speed control. Pressure vessel repairs and refurbishment to the electrical distribution system were also completed. Significant changes were made to improve test section flow quality in the 11-by 11-Foot Transonic leg. After the completion of the construction phase of the project, acceptance and checkout testing was performed to demonstrate the capabilities of the modernized facility. A pneumatic test of the tunnel circuit was performed to verify the structural integrity of the pressure vessel before wind-on operations. Test section turbulence, flow angularity, and acoustic parameters were measured throughout the tunnel envelope to determine the effects of the tunnel flow quality improvements. The new control system processes were thoroughly checked during wind-off and wind-on operations. Manual subsystem modes and automated supervisory modes of tunnel operation were validated. The aerodynamic and structural performance of both the new composite compressor rotor blades and the old aluminum rotor blades was measured. The entire subsonic and supersonic envelope of the 11-by 11-Foot Transonic leg was defined up to the maximum total pressure.
Purpose: Radiotherapy alone is the most common treatment for metastatic spinal cord compression (MSCC) from relatively radioresistant tumors such as renal cell carcinoma, colorectal cancer, and malignant melanoma. However, the results of the 'standard' regimen 30 Gy/10 fractions need to be improved with respect to functional outcome. This study investigated whether a dose escalation beyond 30 Gy can improve treatment outcomes. Methods and Materials: A total of 91 patients receiving 30 Gy/10 fractions were retrospectively compared to 115 patients receiving higher doses (37.5 Gy/15 fractions, 40 Gy/20 fractions) for motor function and local control of MSCC. Ten further potential prognostic factors were evaluated: age, gender, tumor type, performance status, number of involved vertebrae, visceral or other bone metastases, interval from tumor diagnosis to radiotherapy, pretreatment ambulatory status, and time developing motor deficits before radiotherapy. Results: Motor function improved in 18% of patients after 30 Gy and in 22% after higher doses (p = 0.81). On multivariate analysis, functional outcome was associated with visceral metastases (p = 0.030), interval from tumor diagnosis to radiotherapy (p = 0.010), and time developing motor deficits (p < 0.001). The 1-year local control rates were 76% after 30 Gy and 80% after higher doses, respectively (p = 0.64). On multivariate analysis, local control was significantly associated with visceral metastases (p = 0.029) and number of involved vertebrae (p = 0.043). Conclusions: Given the limitations of a retrospective study, escalation of the radiation dose beyond 30 Gy/10 fractions did not significantly improve motor function and local control of MSCC in patients with relatively radioresistant tumors.
Microcomputer-controlled magnetic-bearing test fixture used to develop approaches to design of controls for magnetic bearing actuators designed and constructed. Includes load cells connected to bar, in turn, connected through screw positioners to geared drive motors. Position of equivalent suspended element sensed by position sensors and controlled by drive motors. Provides control of gap in magnetic bearing and of current in electromagnet coil. Measurements made include magnetic-bearing gaps, magnetic flux in bearing gaps, and bearing forces. Approaches to linearization and control developed by use of fixture applicable to wide range of small-gap suspension systems.
Flexibility is one of remarkable characteristics of flexible electronics. Therefore, the analysis of flexible electronics deformation caused by external torques will help its design. In this work, analytical derivation is conducted for flexible electronics treated as multilayer structures. In experiments, an electric motor under computer control exerts a torque to generate torsion, whose twist angles are obtained by using both optical encoder measurement and theoretical calculation. Comparisons are made between experimental and theoretical results for bare PEN (polyethylene naphthalate) substrates of different sizes, multilayer PET (polyethylene terephthalate) substrates, and ITO (indium tin oxide)-coated PET substrates. Finally, a laser displacement sensor is used to measure the out-of-plane deformation for validating the proposed theoretical model.
A balloon-borne winch system has been developed and flight tested which permits the repetitive lowering and hoisting of a stratospheric sampling payload for distances of up to 20 km from a float altitude of 35-40 km. This new approach to in situ stratospheric measurements permits multiple scans of various depths and velocities, closely spaced over a period of hours or days, thus dramatically increasing observational effectiveness. The motor driven winch permits control of ascent velocities from 0-9 m/s with energy derived from a large battery; for descent, the motors are used as generators, velocity is controlled over the same range, and the energy is dumped radiatively to space. The 1.75 mm diameter tether is of braided Kevlar construction with a nylon jacket; it exhibits a 2900 N break strength. Both the winch and the payload suspended by the tether are fully instrumented to evaluate potentially destructive system-induced dynamics and the effects of stratospheric wind shears. The system was successfully flight tested by lowering a 62 kg payload for a distance of 12 km from a float altitude of 38.5 km and hoisting it back up again, both at velocities ranging between 5-9 m/s. Observations indicated minimal system-induced dynamical effects, and no adverse effects due to the 8 m/s wind shear present during flight.
An electron beam test facility, which consists of a precision multidimensional manipulator built into an ultra-high-vacuum bell jar, was designed, fabricated, and operated at Lewis Research Center. The position within the bell jar of a Faraday cup which samples current in the electron beam under test, is controlled by the manipulator. Three orthogonal axes of motion are controlled by stepping motors driven by digital indexers, and the positions are displayed on electronic totalizers. In the transverse directions, the limits of travel are approximately + or - 2.5 cm from the center with a precision of 2.54 micron (0.0001 in.); in the axial direction, approximately 15.0 cm of travel are permitted with an accuracy of 12.7 micron (0.0005 in.). In addition, two manually operated motions are provided, the pitch and yaw of the Faraday cup with respect to the electron beam can be adjusted to within a few degrees. The current is sensed by pulse transformers and the data are processed by a dual channel box car averager with a digital output. The beam tester can be operated manually or it can be programmed for automated operation. In the automated mode, the beam tester is controlled by a microcomputer (installed at the test site) which communicates with a minicomputer at the central computing facility. The data are recorded and later processed by computer to obtain the desired graphical presentations.
Patients with balance disorders want answers to the following basic questions: (1) What is causing my problem? and (2) What can be done about my problem? Information to fully answer these questions must include status of both sensory and motor components of the balance control systems. Computerized dynamic posturography (CDP) provides quantitative assessment of both sensory and motor components of postural control along with how the sensory inputs to the brain interact. This paper reviews the scientific basis and clinical applications of CDP. Specifically, studies describing the integration of vestibular inputs with other sensory systems for postural control are briefly summarized. Clinical applications, including assessment, rehabilitation, and management are presented. Effects of aging on postural control along with prevention and management strategies are discussed.
The International Space Station (ISS) attitude control is provided by two means: The Russian Segment uses thrusters and the U.S. Segment uses double-gimbaled control moment gyroscopes (CMG). CMGs are used as momentum exchange devices, providing non propulsive attitude control for the vehicle. The CMGs are very important for the ISS program because, first, they save propellant - which needs to be transferred to the Station in special cargo vehicles - and, second, they provide the microgravity environment on the Station - which is necessary for scientific experiments planned for the ISS mission. Since 2002, when one of the CMG on the ISS failed, all CMGs are closely monitored. High gimbal rates, vibration spikes, unusual variations of spin motor current and bearing temperatures are of great concern, since these parameters are the CMG health indicators. The telemetry analysis of these and some other CMG parameters is used to determine constrains and make changes to the CMGs operation on board. These CMG limitations, in turn, may limit the ISS attitude control capabilities and may be critical to ISS operation. Therefore, it is important to know whether the CMG parameter is nominal or out of family, and why. The goal of this project is to analyze an important CMG parameter - spin motor current. Some operational decisions are made now based on the spin motor current signatures. The spin motor current depends on gimbal rates, ISS rates, and spin bearing friction. The spin bearing friction in turn depends on the bearing temperatures, wheel rates, normal load - which is a function of gimbal and wheel rates - lubrication, etc. The first task of this project is to create a spin motor current mathematical model based on CMG dynamics model and the current knowledge on bearing friction in microgravity.
Mechanical tele-manipulators reproduce the effects of the hand and arm movements of the worker by means of mechanical transmission elements, installed in a shielding or a containment wall. It shall be constructed in such a manner that the motions, forces and torques, executed by the hand of the worker on the handle of the cold arm, are transmitted respectively to the hot arm and the tongs. The tele-manipulator shall ensure force reflection from the hot arm to the cold arm. The cold arm and hot arm are arranged to have identical kinematics. Additional components are provided on the cold arm, in particular, counter-weights balancing the arms of the tele-manipulators and, where necessary, lockable brakes and/or the control elements for motorized relative motions or off-sets between the hot arm and the cold arm (i.e. indexing). Mechanical tele-manipulators shall be equipped with an electrical indexing of the Y-motion (forward-backward) and X-motion (right-left). For some tele-manipulators with telescopic arm it may also include an electrical extension of the Z-motion (up and down), consisting of a double telescopic arm. The latter is called extended reach. The indexing and extended reach allow the range of action of the hot arm to be increased, while keeping the cold arm in a good ergonomic position.[1] Consequently and in other words the workers are feeling exactly 1:1 the weight of the object handled on the hot arm. Additionally to the forces applied on the mechanical components, it also should be considered the physically effort of the worker to handle objects. How much weight can a worker handle on a short time period and how much weight during whole shift? To answer this question, a description of the mechanical tele-manipulators and the available feature should be made to get a general idea of what is already done to make the work of the workers easier. Interviews of workers will bring their point of view on the situation today. At the end it will be described what kind of solutions are already available to make the work easier and increase the work capacity. (authors)
The Reusable Solid Rocket Motor represents the largest solid rocket motor ever flown and the only human rated solid motor. Each Reusable Solid Rocket Motor (RSRM) provides approximately 3-million lb of thrust to lift the integrated Space Shuttle vehicle from the launch pad. The motors burn out approximately 2 minutes later, separate from the vehicle and are recovered and refurbished. The size of the motor and the need for high reliability were challenges. Thrust shaping, via shaping of the propellant grain, was needed to limit structural loads during ascent. The motor design evolved through several block upgrades to increase performance and to increase safety and reliability. A major redesign occurred after STS-51L with the Redesigned Solid Rocket Motor. Significant improvements in the joint sealing systems were added. Design improvements continued throughout the Program via block changes with a number of innovations including development of low temperature o-ring materials and incorporation of a unique carbon fiber rope thermal barrier material. Recovery of the motors and post flight inspection improved understanding of hardware performance, and led to key design improvements. Because of the multidecade program duration material obsolescence was addressed, and requalification of materials and vendors was sometimes needed. Thermal protection systems and ablatives were used to protect the motor cases and nozzle structures. Significant understanding of design and manufacturing features of the ablatives was developed during the program resulting in optimization of design features and processing parameters. The project advanced technology in eliminating ozone-depleting materials in manufacturing processes and the development of an asbestos-free case insulation. Manufacturing processes for the large motor components were unique and safety in the manufacturing environment was a special concern. Transportation and handling approaches were also needed for the large hardware segments. The reusable solid rocket motor achieved significant reliability via process control, ground test programs, and postflight assessment. Process control is mandatory for a solid rocket motor as an acceptance test of the delivered product is not feasible. Process control included process failure modes and effects analysis, statistical process control, witness panels, and process product integrity audits. Material controls and inspections were maintained throughout the sub tier vendors. Material fingerprinting was employed to assess any drift in delivered material properties. The RSRM maintained both full scale and sub-scale test articles. These enabled continuous improvement of design and evaluation of process control and material behavior. Additionally RSRM reliability was achieved through attention to detail in post flight assessment to observe any shift in performance. The postflight analysis and inspections provided invaluable reliability data as it enables observation of actual flight performance, most of which would not be available if the motors were not recovered. These unique challenges, features of the reusable solid rocket motor, materials and manufacturing issues, and design improvements will be discussed in the paper.
A project in the Advanced Design Program at the University of Arizona is described. The project is named the Autonomous Space Processor for Orbital Debris (ASPOD) and is a Universities Space Research Association (USRA) sponsored design project. The development of ASPOD and the students' abilities in designing and building a prototype spacecraft are the ultimate goals of this project. This year's focus entailed the development of a secondary robotic arm and end-effector to work in tandem with an existent arm in the removal of orbital debris. The new arm features the introduction of composite materials and a linear drive system, thus producing a light-weight and more accurate prototype. The main characteristic of the end-effector design is that it incorporates all of the motors and gearing internally, thus not subjecting them to the harsh space environment. Furthermore, the arm and the end-effector are automated by a control system with positional feedback. This system is composed of magnetic and optical encoders connected to a 486 PC via two servo-motor controller cards. Programming a series of basic routines and sub-routines allowed the ASPOD prototype to become more autonomous. The new system is expected to perform specified tasks with a positional accuracy of 0.5 cm.
This paper is regarding a project in the Advanced Design Program at the University of Arizona. The project is named the Autonomous Space Processor for Orbital Debris (ASPOD) and is a NASA/Universities Space Research Association (USRA) sponsored design project. The development of ASPOD and the students' abilities in designing and building a prototype spacecraft are the ultimate goals of this project. This year's focus entailed the development of a secondary robotic arm and end-effector to work in tandem with an existent arm in the removal of orbital debris. The new arm features the introduction of composite materials and a linear drive system, thus producing a light-weight and more accurate prototype. The main characteristic of the end-effector design is that it incorporates all of the motors and gearing internally, thus not subjecting them to the harsh space environment. Furthermore, the arm and the end-effector are automated by a control system with positional feedback. This system is composed of magnetic and optical encoders connected to a 486 PC via two servo-motor controller cards. Programming a series of basic routines and sub-routines has allowed the ASPOD prototype to become more autonomous. The new system is expected to perform specified tasks with a positional accuracy of 0.5 cm.
We study the opto-mechanical properties of coupled chiral meta-atoms based on a pair of twisted split-ring resonators. By using a simple analytical model in conjunction with the Maxwell stress tensor, we capture insight into the mechanism and find that this structure can be used as a general prototype of subwavelength light-driven actuators over a wide range of frequencies. This coupled structure can provide a strong and tunable torque, and can support different opto-mechanical modes, including uniform rotation, periodically variable rotation and damped oscillations. Our results suggest that chiral meta-atoms are good candidates for creating sub-wavelength motors or wrenches controlled by light.
We are developing an improved gamma camera for molecular breast imaging (MBI) that allows tomographic imaging and improved signal-to-noise over conventional planar methods. We have built a novel gamma camera for MBI that utilizes limited angle tomography, similar to x-ray tomosynthesis, to generate images with depth information and improved signal-to-noise. A unique feature of the gamma tomosynthesis system is a variable-angle slant hole (VASH) collimator. This collimator allows the camera to remain flush against the compression paddle during the tomographic acquisition, which achieves high spatial resolution and simplified detector motion. We constructed a VASH collimator from a stack of tungsten sheets, each sheet containing a matrix of holes created by photo-etching. With the holes of the sheets aligned, a parallel-hole collimator is created; shearing the sheets creates a variable angle slant hole collimator. The shearing is controlled by a motorized mechanism. The collimator was mounted on a commercial MBI camera and projection data were acquired of a set of capillary tube line sources over a 50° range of angles. The projection data were reconstructed using the iterative MLEM method. Results demonstrated the ability of the system to resolve in the depth dimension, and spatial resolution matched expected values. We conclude that the proposed gamma tomosynthesis system has the potential to provide improved signal-to-noise over conventional MBI methods and allow a reduction in the administered radioactivity and patient dose.
Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.
NuMI (Neutrinos at Main Injector) beamline at Fermi National Accelerator Laboratory provides neutrinos to various neutrino experiments. The hadron monitor consisting of a 5 by 5 array of ionization chambers is part of the diagnostics for the beamline. In order to calibrate the hadron monitor, a gamma source is needed. We present the status and progress of the development of the calibration system for the hadron monitor. The system based on Raspberry Pi controlled CNC system, motors, and position sensors would allow us to place the gamma source precisely to calibrate the signal gain of individual pixels. The ultimate outcome of the study is a prototype of the calibration system.
The state-of-the-art hybrid electric vehicles (HEVs) require the inverter cooling system to have a separate loop to avoid power semiconductor junction over temperatures because the engine coolant temperature of 105°C does not allow for much temperature rise in silicon devices. The proposed work is to develop an advanced soft-switching inverter that will eliminate the device switching loss and cut down the power loss so that the inverter can operate at high-temperature conditions while operating at high switching frequencies with small current ripple in low inductance based permanent magnet motors. The proposed tasks also include high-temperature packaging and thermal modeling and simulation to ensure the packaged module can operate at the desired temperature. The developed module will be integrated with the motor and vehicle controller for dynamometer and in-vehicle testing to prove its superiority. This report will describe the detailed technical design of the soft-switching inverters and their test results. The experiments were conducted both in module level for the module conduction and switching characteristics and in inverter level for its efficiency under inductive and dynamometer load conditions. The performance will be compared with the DOE original specification.