Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

CZT detectors used in different irradiation geometries: Simulations and experimental results

The purpose of this work was to evaluate potential advantages and limitations of CZT detectors used in surface-on, edge-on, and tilted angle irradiation geometries. Simulations and experimental investigations of the energy spectrum measured by a CZT detector have been performed using different irradiation geometries of the CZT. Experiments were performed using a CZT detector with 10x10 mm{sup 2} size and 3 mm thickness. The detector was irradiated with collimated photon beams from Am-241 (59.5 keV) and Co-57 (122 keV). The edge-scan method was used to measure the detector response function in edge-on illumination mode. The tilted angle mode was investigated with the radiation beam directed to the detector surface at angles of 90 degree sign , 15 degree sign , and 10 degree sign . The Hecht formalism was used to simulate theoretical energy spectra. The parameters used for simulations were matched to experiment to compare experimental and theoretical results. The tilted angle CZT detector suppressed the tailing of the spectrum and provided an increase in peak-to-total ratio from 38% at 90 degree sign to 83% at 10 degree sign tilt angle for 122 keV radiation. The corresponding increase for 59 keV radiation was from 60% at 90 degree sign to 85% at 10 degree sign tilt angle. The edge-on CZT detector provided high energy resolution when the beam thickness was much smaller than the thickness of CZT. The FWHM resolution in edge-on illumination mode was 4.2% for 122 keV beam with 0.3 mm thickness, and rapidly deteriorated when the thickness of the beam was increased. The energy resolution of surface-on geometry suffered from strong tailing effect at photon energies higher than 60 keV. It is concluded that tilted angle CZT provides high energy resolution but it is limited to a 1D linear array configuration. The surface-on CZT provides 2D pixel arrays but suffers from tailing effect and charge build up. The edge-on CZT is considered suboptimal as it requires small beam thickness and also suffers from charge buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Close-packed Arrays of Transition-edge X-ray Microcalorimeters with High Spectral Resolution at 5.9 keV

We present measurements of high fill-factor arrays of superconducting transition-edge x-ray microcalorimeters designed to provide rapid thermalization of the x-ray energy. We designed an x-ray absorber that is cantilevered over the sensitive part of the thermometer itself, making contact only at normal metal-features. With absorbers made of electroplated gold, we have demonstrated an energy resolution between 2.4 and 3.1 eV at 5.9 keV on 13 separate pixels. We have determined the thermal and electrical parameters of the devices throughout the superconducting transition, and, using these parameters, have modeled all aspects of the detector performance.

Iyomoto, N.↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of BaFCl:Eu2+ scintillating composites for X-ray imaging screens

A cost-effective solution for improving X-ray imaging detectors is presented through the use of a translucent scintillating composite and pixelated screen structure. A large quantity of BaFCl:Eu 2+ polycrystalline scintillator powder was synthesized via flux growth and its optical properties characterized through photoluminescence (PL) and absolute quantum yield (QY). UV-curable composites containing the BaFCl:Eu 2+ material were fabricated with differing amounts of NOA1665 and NOA170 optical adhesives. It was determined that, when the two resins were combined, the translucency of the resulting composite could be enhanced. The BaFCl:Eu 2+ composite was also cast into a pixelated glass screen containing an array of 160 μm x 160 μm holes by two separate methods: composite paste application and powder-resin application. Based on visual inspection, using a composite paste to fill the apertures proved to be more effective in creating a uniform packing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

Radiation Hard CMOS Sensors for Detector at High Energy Colliders

In this project we developed a radiation hard CMOS sensor architecture for High Energy Colliders. The key accomplishments were: 1. Developed a sensor architecture to support very high occupancy rate and hit rates 2. Developed, simulated (TCAD), and fabricated 20 different types of pixelated test structures for the quadruple well high resistivity substrate process. Measured performance of these pixel test structures; Dark currents were found to be close to physical limits; and Quantum efficiency were found to be close to ideal as well 3. Defined the scope for the PDK for the quadruple well process on high resistivity silicon Highlights of the new architecture are: Readout of pixel arrays with reconstruction efficiency >99% at hit rates of 500 MHits/cm 2 and array occupancy of 0.2%; Minimization of in-pixel signal storage requirement (data will be read out at frame rates of 1MHz); Low power dissipation through integration of fragmented projection architecture (Minimum analog power dissipation); Pixel array level data reduction (Hit location is encoded through shape of sub-block projections); Programmable resolution and frame rate (Pixels can be binned to increase frame rate); Minimum data overhead, encoded projection results for all sub-blocks are read out without location information

43 PARTICLE ACCELERATORS↗

Integrated Dual Imaging Detector

A new type of image detector was designed to simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging detector (IDID) consists of a lenslet array and a polarizing beamsplitter bonded to a commercial charge coupled device (CCD). The IDID simplifies the design and operation of solar vector magnetographs and the imaging polarimeters and spectroscopic imagers used, for example, in atmosphere and solar research. When used in a solar telescope, the vector magnetic fields on the solar surface. Other applications include environmental monitoring, robot vision, and medical diagnoses (through the eye). Innovations in the IDID include (1) two interleaved imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 5) electrons per pixel); (3) simultaneous readout and display of both images; and (4) laptop computer signal processing to produce polarization maps in field situations.

Rust, David M.↗

High definition large area mapping of geological samples using a Maia detector array in the Nuclear Microprobe

A Maia detector array has been utilized and installed on the CSIRO-MARC Nuclear Microprobe. Maia uses an annular array of 384 silicon detectors to provide a solid-angle of 1.3 sr to improve the collection of X-rays induced by Particle Induced X-ray Emission (PIXE) using a micron focussed MeV proton beam. It features event-by-event data acquisition with dead-time correction and pileup rejection and a total count-rate capacity above 10 M/s, versatile stage and beam scanning modes (coupled to the DAQ-36 system described previously) to cater for a variety of sample configuration and experimental needs, precise measurement of transit time and integration of beam fluence per pixel, and spectral deconvolution of event data in real-time using the Dynamic Analysis method to provide element images during data collection. In this work we demonstrate the system on thin sections made from geological samples extracted from active seafloor hydrothermal vents in the PACMANUS hydrothermal field in Papua New Guinea.

36 MATERIALS SCIENCE↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗

Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDM configuration the TES is AC voltage biased at a well defined frequencies (between 0.3 to 10 MHz) and acts as an AM modulating element. In this paper we will present a full comparison of the performance of a TES microcalorimeter under DC bias and AC bias at a frequency of 370 kHz. In both cases we measured the current-to-voltage characteristics, the complex impedance, the noise, the X-ray responsivity, and energy resolution. The behaviour is very similar in both cases, but deviations in performances are observed for detector working points low in the superconducting transition (R/R{sub N}<0.5). The measured energy resolution at 5.89 keV is 2.7 eV for DC bias and 3.7 eV for AC bias, while the baseline resolution is 2.8 eV and 3.3 eV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

SPARR: Spiking/Processing Array for Wide Dynamic Range and High Resolution Photonic Sensing

The Spiking/Processing Array (spARR) is a novel photonic focal plane that uses pixels which generate electronic spikes autonomously and without a clock. These spikes feed into a network of digital asynchronous processing elements or DAPES. By building a useful assemblage of DAPES, and connecting them together in the correct way, sophisticated signal processing can be accomplished within the focal plane. Autonomous self-resetting pixels (AsP) enable SPARR to generate electronic response with very small signals--as little as a single photon in the case of Geiger mode avalanche photodiodes to as few as several hundred photons for in-cmos photodetectors. These spiking pixels enable fast detector response, but do not draw as much continuous power as synchronous clocked designs. The spikes emitted by the pixels all have the same magnitude, the information from the scene is effectively encoded into the rate of spikes and the time at which the spike is emitted. The spiking pixels, having converted incident light into electronic spikes, supply the spikes to a network of digital asynchronous processors. These are small state machines which respond to the spikes arriving at their input ports by either remaining unchanged or updating their internal state and possibly emitting a spike on one or more output ports. We show a design that accomplishes the sophisticated signal processing of a Haar spatial wavelet transform with spatial-spectral whitening. We furthermore show how this design results in a data streams which support imaging and transient optical source detection. Two simulators support this analysis: SPICE and sparrow. The CMOS SPICE simulator Cadence provides accurate CMOs design with accounting for effects of circuit parasitics throughout layout, accurate timing, and accurate energy consumption estimates. To more rapidly assess larger networks with more pixels, sparrow is a custom discrete event simulator that supports the non-homogeneous Poisson processes that lie behind photoelectric interaction. Sparrow is a photon-exact simulator that nevertheless performs SPARR system simulator for large-scale systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Principal Component Analysis of Up-The-Ramp Sampled Infrared Array Data

We describe the results of principal component analysis (PCA) of up-the-ramp sampled infrared (IR) array data from the Hubble Space Telescope wide field camera 3 (WFC3 IR), James Webb Space Telescope NIRSpec, and prototype Wide Field Infrared Survey Telescope’s wide field instrument detectors. These systems use, respectively, Teledyne H1R, H2RG, and H4RG-10 near-IR detector arrays with a variety of IR array controllers. The PCA shows that the Legendre polynomials approximate the principal components of these systems (i.e., they roughly diagonalize the covariance matrix). In contrast to the monomial basis that is widely used for polynomial fitting and linearization today, the Legendre polynomials are an orthonormal basis. They provide a quantifiable, compact, and (nearly) linearly uncorrelated representation of the information content of the data. By fitting a few Legendre polynomials, nearly all of the meaningful information in representative WFC3 astronomical datacubes can be condensed from 15 up-the-ramp samples down to 6 compressible Legendre coefficients per pixel. The higher order coefficients contain time domain information that is lost when one projects up-the-ramp sampled datacubes onto two-dimensional images by fitting a straight line, even if the data are linearized before fitting the line. Going forward, we believe that this time domain information is potentially important for disentangling the various nonlinearities that can affect IR array observations, i.e., inherent pixel nonlinearity, persistence, burn in, brighter-fatter effect, (potentially) nonlinear interpixel capacitance, and perhaps others.

Rauscher, Bernard J.↗

Kilopixel X-Ray Microcalorimeter Arrays for Astrophysics: Device Performance and Uniformity

We are developing kilopixel arrays of TES microcalorimeters to enable high-resolution x-ray imaging spectrometers for future x-ray observatories and laboratory astrophysics experiments. Our current array design was targeted as a prototype for the X-ray Microcalorimeter Spectrometer proposed for the International X-ray Observatory, which calls for a 40×40-pixel core array of 300 micron devices with 2.5 eV energy resolution (at 6 keV). Here we present device characterization of our 32×32 arrays, including x-ray spectral performance of individual pixels within the array. We present our results in light of the understanding that our Mo/Au TESs act as weak superconducting links, causing the TES critical current (I(sub c)) and transition shape to oscillate with applied magnetic field (B). We show I(sub c)(B) measurements and discuss the uniformity of these measurements across the array, as well as implications regarding the uniformity of device noise and response. In addition, we are working to reduce pixel-to-pixel electrical and thermal crosstalk; we present recent test results from an array that has microstrip wiring and an angle-evaporated copper backside heatsinking layer, which provides copper coverage on the four sidewalls of the silicon wells beneath each pixel.

Transition-edge sensors A[center dot] Superconduct↗

Investigation of Timing Properties for an Event Driven with Access and Reset Decoder Readout Architecture for a Pixel Array

The large number of data generating sources (data channels) on a single chip requires appropriate techniques to manage a readout from these channels. One of the main methods is sharing a medium of transmission, which requires arbitration to avoid collisions or deadlocks. Existing solutions face several problems such as a dead time, unintended prioritization or metastability. That is why we decided to create a new readout architecture named EDWARD i.e., Event Driven with Access and Reset Decoder. The EDWARD architecture gets rid of the earlier mentioned problems and mitigates the other ones. However, due to the use of logic circuits outside a standard cell library, which are hard to characterize, we were challenged to perform an additional transient analysis to validate the architecture. Here we show a methodology and the results of the simulations. Based on the results obtained we can confirm the functional correctness of the system and plan the optimization of operating conditions in order to achieve better performance. Our goal is to use the EDWARD architecture in the future radiation detectors to be built at Brookhaven National Laboratory.

47 OTHER INSTRUMENTATION↗

Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array

Purpose: The purpose of this study was to determine whether a two-dimensional (2D) ion chamber array detector quickly and accurately measures patient-specific dose distributions in treatment with passively scattered and spot scanning proton beams. Methods: The 2D ion chamber array detector MatriXX was used to measure the dose distributions in plastic water phantom from passively scattered and spot scanning proton beam fields planned for patient treatment. Planar dose distributions were measured using MatriXX, and the distributions were compared to those calculated using a treatment-planning system. The dose distributions generated by the treatment-planning system and a film dosimetry system were similarly compared. Results: For passively scattered proton beams, the gamma index for the dose-distribution comparison for treatment fields for three patients with prostate cancer and for one patient with lung cancer was less than 1.0 for 99% and 100% of pixels for a 3% dose tolerance and 3 mm distance-to-dose agreement, respectively. For spot scanning beams, the mean ({+-} standard deviation) percentages of pixels with gamma indices meeting the passing criteria were 97.1%{+-}1.4% and 98.8%{+-}1.4% for MatriXX and film dosimetry, respectively, for 20 fields used to treat patients with prostate cancer. Conclusions: Unlike film dosimetry, MatriXX provides not only 2D dose-distribution information but also absolute dosimetry in fractions of minutes with acceptable accuracy. The results of this study indicate that MatriXX can be used to verify patient-field specific dose distributions in proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of lunar ilmenite abundance from remotely sensed data

Of fundamental importance in the utilization of indigenous resources for a future permanently manned lunar base is the identification and mapping of the abundance distribution of the mineral ilmenite, which is currently considered the most readily identifiable and most easily accessible source of oxygen needed for human consumables and spacecraft propellant. Solid state detector array technology now permits the use of ground based multispectral remote sensing techniques to produce maps with better than one kilometer spatial resolution and uncertainties of about two weight-percent TiO2 abundance. An empirical relationship between the weight-percent abundance of titanium dioxide and the 400/560 nm spectral ratio measured in returned lunar samples was used. Because this abundance correlation is valid only for mature lunar mare regolith, the distribution of immature mafic minerals which were found to be correlated primarily with steep slopes exposing bedrock was qualitatively mapped. The first mapping phase focused on the entire lunar nearside at 5.3 km per pixel, and on experiments with more sensitive spectral ratios. Relative spectrophotometry was employed to aid in identifying wavelengths that provide greater spectral contrast. It was found that the 400/730 nm ratio improved the abundance sensitivity by 37 percent, while the 950/730 nm ratio improved mafic mineral contrast about 100 percent. The second mapping phase utilized a large experimental CCD at 280 m per pixel to map the high titanium regions identified in the phase one mapping. The high resolution maps provide data on the small scale (500 m) variations in abundance and their relationship to morphological units.

Larson, S. M.↗

GaAs QWIP Array Containing More Than a Million Pixels

A 1,024 x 1,024-pixel array of quantum-well infrared photodetectors (QWIPs) has been built on a 1.8 x 1.8- cm GaAs chip. In tests, the array was found to perform well in detecting images at wavelengths from 8 to 9 m in operation at temperatures between 60 and 70 K. The largest-format QWIP prior array that performed successfully in tests contained 512 x 640 pixels. There is continuing development effort directed toward satisfying actual and anticipated demands to increase numbers of pixels and pixel sizes in order to increase the imaging resolution of infrared photodetector arrays. A 1,024 x 1,024-pixel and even larger formats have been achieved in the InSb and HgCdTe material systems, but photodetector arrays in these material systems are very expensive and manufactured by fewer than half a dozen large companies. In contrast, GaAs-photodetector-array technology is very mature, and photodetectors in the GaAs material system can be readily manufactured by a wide range of industrial technologists, by universities, and government laboratories. There is much similarity between processing in the GaAs industry and processing in the pervasive silicon industry. With respect to yield and cost, the performance of GaAs technology substantially exceeds that of InSb and HgCdTe technologies. In addition, GaAs detectors can be designed to respond to any portion of the wavelength range from 3 to about 16 micrometers - a feature that is very desirable for infrared imaging. GaAs QWIP arrays, like the present one, have potential for use as imaging sensors in infrared measuring instruments, infrared medical imaging systems, and infrared cameras.

Jhabvala, Murzy↗