Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

High burn-up spent nuclear fuel transport reliability investigation

Transportation packages for spent nuclear fuel (SNF) must meet safety requirements under normal and accident conditions as specified by federal regulations. During road or rail transportation, SNF will experience unique conditions that could affect the structural integrity of the cladding due to vibrational and impact loading. Lack of SNF inertia-induced dynamic fatigue data, especially for the high burn-up (HBU) SNF systems, has brought significant challenges to quantify the reliability of SNF during transportation with a high degree of confidence. To address this shortcoming, Oak Ridge National Laboratory (ORNL) developed a SNF vibration testing protocol without fuel pellets removal, which has provided significant insight regarding the dynamics of mechanical interactions between pellet and cladding. This research has provided a detailed understanding about the effect of loading rate and loading mode on the fatigue damage evolution of HBU SNF under normal conditions of transport (NCT). Static and dynamic loading experimental data were generated for SNF under simulated transportation environments using a cyclic integrated reversible-bending fatigue tester (CIRFT), an enabling hot-cell testing technology developed at ORNL. SNF flexural tensile strength and fatigue S-N data from pressurized water reactors (PWRs) and boiling water reactor (BWR) HBU SNF are presented in this paper, including the potential effects of pellet-cladding interface bonding, hydride reorientation, and thermal annealing to SNF vibration reliability. The data presented here can be used to meet the nuclear industry and U.S. Nuclear Regulatory Commission needs in safety of SNF transportation operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proposing an Abstracted Interface and Protocol for Computer Systems

While it made sense for historical reasons to develop different interfaces and protocols for memory channels, CPU to CPU interactions, and I/O devices, ongoing developments in the computer industry are leading to more converged requirements and physical implementations for these interconnects. As it becomes increasingly common for advanced components to contain a variety of computational devices as well as memory, the distinction between processors, memory, accelerators, and I/O devices becomes increasingly blurred. As a result, the interface requirements among such components are converging. There is also a wide range of new disruptive technologies that will impact the computer market in the coming years, including 3D integration and emerging NVRAM memory. Optimal exploitation of these technologies cannot be done with the existing memory, storage, and I/O interface standards. The computer industry has historically made major advances when industry players have been able to add innovation behind a standard interface. The standard interface provides a large market for their products and enables relatively quick and widespread adoption. To enable a new wave of innovation in the form of advanced memory products and accelerators, we need a new standard interface explicitly designed to provide both the performance and flexibility to support new system integration solutions

97 MATHEMATICS AND COMPUTING↗

Scale Up of Malonic Acid Fermentation Process: Cooperative Research and Development Final Report, CRADA Number CRD-16-612

The goal of this work is to use the large fermentation vessels in the National Renewable Energy Laboratory's (NREL) Integrated Biorefinery Research Facility (IBRF) to scale-up Lygos' biological-based process for producing malonic acid and to generate performance data. Initially, work at the 1 L scale validated successful transfer of Lygos' fermentation protocols to NREL using a glucose substrate. Outside of the scope of the CRADA with NREL, Lygos tested their process on lignocellulosic sugars produced by NREL at Lawrence Berkeley National Laboratory's (LBNL) Advanced Biofuels Process Development Unit (ABPDU). NREL produced these cellulosic sugar solutions from corn stover using a separate cellulose/hemicellulose process configuration. Finally, NREL performed fermentations using glucose in large fermentors (1,500- and 9,000-L vessels) to intermediate product and to demonstrate successful performance of Lygos' technology at larger scales.

09 BIOMASS FUELS↗

Long-Term Stability Metrics of Photoelectrochemical Water Splitting

Photoelectrochemical (PEC) water splitting, one of the most promising technologies for clean hydrogen generation, has drawn considerable attention over the past few decades. Achieving simultaneous highly efficient and stable unassisted PEC water splitting has been the “holy grail” in clean and renewable fuel generation. State-of-the-art photoelectrodes have shown relatively high efficiencies (∼10–20%). Still, their stability is limited due to photoelectrode chemical instability, electrolyte resistance, mass transfer issues, and an often unoptimized experimental setup. In this work, we present a framework and a set of protocols for conducting long-term stability experiments and further provide details on several critical factors such as light source calibration, choosing the right counter electrode, the configuration of the PEC cell, and photoelectrode sample preparation.

08 HYDROGEN↗

How Should Researchers Measure Perovskite-Based Monolithic Multijunction Solar Cells’ Performance? A Calibration Lab's Perspective

Perovskite multijunctions (PVSK MJs) have made remarkable progress with monolithic PVSK/PVSK tandems surpassing the efficiency of single-junction (1 J) PVSK cells and PVSK/Si cells reported to exceed the 30% efficiency mark. These efficiencies are reported at standard test conditions (STC), established by the photovoltaic (PV) community to facilitate comparison between devices and technologies. Herein, it is discussed why an accurate STC performance measurement for a MJ is more complicated than for a 1 J cell and the special aspects to be considered when measuring the current-voltage characteristics and the performance of PVSK-containing MJ cells are emphasized. It is discussed why a spectrally adjustable solar simulator is needed and the sequence of accurate performance measurement, namely measurement of the spectral response of each junction, adjustment of the spectrum, and appropriate protocols for measuring the power output of the device at STC, is presented. For all these, common errors and pitfalls that sometime lead to misleading interpretation of the results are presented, and the methods to evaluate the accuracy of the data when a spectrally adjustable solar simulator is not available are recommended. Finally, first step is taken toward recommending performance measurement approaches when high throughput is required as will eventually be in a production line.

14 SOLAR ENERGY↗

SetBERT: the deep learning platform for contextualized embeddings and explainable predictions from high-throughput sequencing

MOTIVATION: High-throughput sequencing (HTS) is a modern sequencing technology used to profile microbiomes by sequencing thousands of short genomic fragments from the microorganisms within a given sample. This technology presents a unique opportunity for artificial intelligence to comprehend the underlying functional relationships of microbial communities. However, due to the unstructured nature of HTS data, nearly all computational models are limited to processing DNA sequences individually. This limitation causes them to miss out on key interactions between microorganisms, significantly hindering our understanding of how these interactions influence the microbial communities as a whole. Furthermore, most computational methods rely on post-processing of samples which could inadvertently introduce unintentional protocol-specific bias. RESULTS: Addressing these concerns, we present SetBERT, a robust pre-training methodology for creating generalized deep learning models for processing HTS data to produce contextualized embeddings and be fine-tuned for downstream tasks with explainable predictions. By leveraging sequence interactions, we show that SetBERT significantly outperforms other models in taxonomic classification with genus-level classification accuracy of 95%. Furthermore, we demonstrate that SetBERT is able to accurately explain its predictions autonomously by confirming the biological-relevance of taxa identified by the model. AVAILABILITY AND IMPLEMENTATION: All source code is available at https://github.com/DLii-Research/setbert. SetBERT may be used through the q2-deepdna QIIME 2 plugin whose source code is available at https://github.com/DLii-Research/q2-deepdna.

Ludwig, David W↗

MO-D-213-06: Quantitative Image Quality Metrics Are for Physicists, Not Radiologists: How to Communicate to Your Radiologists Using Their Language

Purpose: A framework for explaining differences in image quality to non-technical audiences in medial imaging is needed. Currently, this task is something that is learned “on the job.” The lack of a formal methodology for communicating optimal acquisition parameters into the clinic effectively mitigates many technological advances. As a community, medical physicists need to be held responsible for not only advancing image science, but also for ensuring its proper use in the clinic. This work outlines a framework that bridges the gap between the results from quantitative image quality metrics like detectability, MTF, and NPS and their effect on specific anatomical structures present in diagnostic imaging tasks. Methods: Specific structures of clinical importance were identified for a body, an extremity, a chest, and a temporal bone protocol. Using these structures, quantitative metrics were used to identify the parameter space that should yield optimal image quality constrained within the confines of clinical logistics and dose considerations. The reading room workflow for presenting the proposed changes for imaging each of these structures is presented. The workflow consists of displaying images for physician review consisting of different combinations of acquisition parameters guided by quantitative metrics. Examples of using detectability index, MTF, NPS, noise and noise non-uniformity are provided. During review, the physician was forced to judge the image quality solely on those features they need for diagnosis, not on the overall “look” of the image. Results: We found that in many cases, use of this framework settled mis-agreements between physicians. Once forced to judge images on the ability to detect specific structures inter reader agreement was obtained. Conclusion: This framework will provide consulting, research/industrial, or in-house physicists with clinically relevant imaging tasks to guide reading room image review. This framework avoids use of the overall “look” or “feel” to dictate acquisition parameter selection. Equipment grants GE Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-P-13: NRG Oncology Medical Physics Manpower Survey Quantifying Support Demands for Multi Institutional Clinical Trials

Purpose: A survey was taken by NRG Oncology to assess Full Time Equivalent (FTE) contributions to multi institutional clinical trials by medical physicists.No current quantification of physicists’ efforts in FTE units associated with clinical trials is available. The complexity of multi-institutional trials increases with new technologies and techniques. Proper staffing may directly impact the quality of trial data and outcomes. The demands on physics time supporting clinical trials needs to be assessed. Methods: The NRG Oncology Medical Physicist Subcommittee created a sixteen question survey to obtain this FTE data. IROC Houston distributed the survey to their list of 1802 contact physicists. Results: After three weeks, 363 responded (20.1% response). 187 (51.5%) institutions reporting external beam participation were processed. There was a wide range in number of protocols active and supported at each institution. Of the 187 clinics, 134 (71.7%) participate in 0 to 10 trials, 28 (15%) in 11 to 20 trials, 10 (5.3%) in 21 to 30 trials, 9 (4.8%) had 40 to 75 trials. On average, physicist spent 2.7 hours (SD: 6.0) per week supervising or interacting with clinical trial staff. 1.25 hours (SD: 3.37), 1.83 hours (SD: 4.13), and 0.64 hours(SD: 1.13) per week were spent on patient simulation, reviewing treatment plans, and maintaining a DICOM server, respectively. For all protocol credentialing activities, physicist spent an average of 37.05 hours (SD: 96.94) yearly. To support dosimetrists, clinicians, and therapists, physicist spend on average 2.07 hours (SD: 3.52) per week just reading protocols. Physicist attended clinical trial meetings for on average 1.13 hours (SD: 1.85) per month. Conclusion: Responding physicists spend a nontrivial amount of time: 8.8 hours per week (0.22 FTE) supporting, on average, 9 active multi-institutional clinical trials.

60 APPLIED LIFE SCIENCES↗

Proposing an Abstracted Interface and Protocol for Computer Systems

While it made sense for historical reasons to develop different interfaces and protocols for memory channels, CPU to CPU interactions, and I/O devices, ongoing developments in the computer industry are leading to more converged requirements and physical implementations for these interconnects. As it becomes increasingly common for advanced components to contain a variety of computational devices as well as memory, the distinction between processors, memory, accelerators, and I/O devices become s increasingly blurred. As a result, the interface requirements among such components are converging. There is also a wide range of new disruptive technologies that will impact the computer market in the coming years , including 3D integration and emerging NVRAM memory. Optimal exploitation of these technologies cannot be done with the existing memory, storage, and I/O interface standards. The computer industry has historically made major advances when industry players have been able to add innovation behind a standard interface. The standard interface provides a large market for their products and enables relatively quick and widespread adoption. To enable a new wave of innovation in the form of advanced memory products and accelerators, we need a new standard interface explicitly designed to provide both the performance and flexibility to support new system integration solutions.

97 MATHEMATICS AND COMPUTING↗

Can Error Mitigation Improve Trainability of Noisy Variational Quantum Algorithms?

Variational Quantum Algorithms (VQAs) are often viewed as the best hope for near-term quantum advantage. However, recent studies have shown that noise can severely limit the trainability of VQAs, e.g., by exponentially flattening the cost landscape and suppressing the magnitudes of cost gradients. Error Mitigation (EM) shows promise in reducing the impact of noise on near-term devices. Thus, it is natural to ask whether EM can improve the trainability of VQAs. In this work, we first show that, for a broad class of EM strategies, exponential cost concentration cannot be resolved without committing exponential resources elsewhere. This class of strategies includes as special cases Zero Noise Extrapolation, Virtual Distillation, Probabilistic Error Cancellation, and Clifford Data Regression. Second, we perform analytical and numerical analysis of these EM protocols, and we find that some of them (e.g., Virtual Distillation) can make it harder to resolve cost function values compared to running no EM at all. As a positive result, we do find numerical evidence that Clifford Data Regression (CDR) can aid the training process in certain settings where cost concentration is not too severe. Our results show that care should be taken in applying EM protocols as they can either worsen or not improve trainability. On the other hand, our positive results for CDR highlight the possibility of engineering error mitigation methods to improve trainability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A standards perspective on genomic data reusability and reproducibility

Genomic and metagenomic sequence data provides an unprecedented ability to re-examine findings, offering a transformative potential for advancing research, developing computational tools, enhancing clinical applications, and fostering scientific collaboration. However, effective and ethical reuse of genomics data is hampered by numerous technical and social challenges. The International Microbiome and Multi’Omics Standards Alliance (IMMSA, https://www.microbialstandards.org/) and the Genomic Standards Consortium (GSC, https://gensc.org) hosted a 5-part seminar series “A Year of Data Reuse” in 2024 to explore challenges and opportunities of data reuse and reproducibility across disparate domains of the genomic sciences. Addressing these challenges will require a multifaceted approach, including common metadata reporting, clear communication, standardized protocols, improved data management infrastructure, ethical guidelines, and collaborative policies that prioritize transparency and accessibility. We offer strategies to enable responsible and technically feasible data reuse, recognition of data reproducibility challenges, and emphasizing the importance of cross-disciplinary efforts in the pursuit of open science and data-driven innovation.

59 BASIC BIOLOGICAL SCIENCES↗

The development and application of the Remotely Monitored Sealing Array (RMSA).

Advanced sealing technologies are often an integral part of a containment surveillance (CS) approach to detect undeclared diversion of nuclear materials. As adversarial capabilities continue to advance, the sophistication of the seal design must advance as well. The intelligent integration of security concepts into a physical technology used to seal monitored items is a fundamental requirement for secure containment. Seals have a broad range of capabilities. These capabilities must be matched appropriately to the application to establish the greatest effectiveness from the seal. However, many current seal designs and their application fail to provide the high confidence of detection and timely notification that can be appreciated with new technology. Additionally, as monitoring needs rapidly expand, out-pacing budgets, remote monitoring of low-cost autonomous sealing technologies becomes increasingly appealing. The Remotely Monitored Sealing Array (RMSA) utilizes this technology and has implemented cost effective security concepts establishing the high confidence that is expected of active sealing technology today. RMSA is a system of relatively low-cost but secure active loop seals for the monitoring of nuclear material containers. The sealing mechanism is a fiber optic loop that is pulsed using a low-power LED circuit with a coded signal to verify integrity. Battery life is conserved by the use of sophisticated power management techniques, permitting many years of reliable operation without battery replacement or other maintenance. Individual seals communicate by radio using a secure transmission protocol using either of two specially designated communication frequency bands. Signals are encrypted and authenticated by private key, established during the installation procedure, and the seal bodies feature both active and passive tamper indication. Seals broadcast to a central 'translator' from which information is both stored locally and/or transmitted remotely for review. The system is especially appropriate for nuclear material storage facilities, indoor or outdoor, enabling remote inspection of status rather than tedious individual seal verification, and without the need for interconnected cabling. A handheld seal verifier is also available for an inspector to verify any particular individual seal in close proximity. This paper will discuss the development of the RMSA sealing system, its capabilities, its application philosophy, and projected future trends.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Science and Technology Review (March 2014)

Over the past few years, Lawrence Livermore has experienced a surge of innovation in radiochemistry—the science of generating, identifying, isolating, and characterizing the radioactive isotopes of chemical elements. For example, Livermore researchers have developed a technique for producing double-sided target foils and built a target surface mapping tool, which increased the productivity of stockpile stewardship experiments. Radiochemists are also using the Laboratory’s particle accelerator to measure nuclear reaction products for reactor safety and nuclear forensics research. Another Livermore team is making synthetic nuclear debris samples with ingredients that more closely match debris from a real explosion for use in isotope identification exercises. Researchers are also refining the chemicals and protocols required to perform wet-chemistry experiments on transactinides, shortlived heavy elements such as flerovium and livermorium. A collaboration with two universities is developing a portable, automated system that can quickly capture, prepare, and chemically test radioisotopes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Critical Parameters for Evaluating Coin Cells and Pouch Cells of Rechargeable Li-Metal Batteries

Lithium ion and lithium metal batteries have received tremendous interest in the last decade for a wide range of energy storage applications. Although great progress has been made in developing new electrode materials and concepts, it is difficult to rapidly incorporate these advances in battery technologies. A key challenge is the knowledge gap between the fundamental materials research and the cell-level understanding of the relationship between high energy and stable cycling. As a result, the literature reports are based on a wide range of experimental conditions that cannot be easily realized in realistic cells. Taking lithium metal batteries as an example, this paper briefly discusses the fundamental mechanisms that lead to the inconsistent observations in battery research. We then propose development of a standard testing protocol based on the requirements of high-energy lithium metal cells. The importance of building a standard testing protocol is emphasized to accelerate the discovery of solutions for real challenges as well as inspire innovations that are readily adaptable to real batteries.

Chen, Shuru↗

VOLTTRON 2016

VOLTTRON is a flexible, reliable, and scalable platform for distributed control and sensing. VOLTTRON serves in four primary roles: •A reference platform for researchers to quickly develop control applications for transactive energy. •A reference platform with flexible data store support for energy analytics applications either in academia or in commercial enterprise. •A platform from which commercial enterprise can develop products without license issues and easily integrate into their product line. •An accelerator to drive industry adoption of transactive energy and advanced building energy analytics. Pacific Northwest National Laboratory, with funding from the U.S. Department of Energy’s Building Technologies Office, developed and maintains VOLTTRON as an open-source community project. VOLTTRON source code includes agent execution software; agents that perform critical services that enable and enhance VOLTTRON functionality; and numerous agents that utilize the platform to perform a specific function (fault detection, demand response, etc.). The platform supports energy, operational, and financial transactions between networked entities (equipment, organizations, buildings, grid, etc.) and enhance the control infrastructure of existing buildings through the use of open-source device communication, control protocols, and integrated analytics.

97 MATHEMATICS AND COMPUTING↗

Comparative Sequence Analysis of Multidrug-Resistant IncA/C Plasmids from Salmonella enterica

Determinants of multidrug resistance (MDR) are often encoded on mobile elements, such as plasmids, transposons, and integrons, which have the potential to transfer among foodborne pathogens, as well as to other virulent pathogens, increasing the threats these traits pose to human and veterinary health. Our understanding of MDR among Salmonella has been limited by the lack of closed plasmid genomes for comparisons across resistance phenotypes, due to difficulties in effectively separating the DNA of these high-molecular weight, low-copy-number plasmids from chromosomal DNA. To resolve this problem, we demonstrate an efficient protocol for isolating, sequencing and closing IncA/C plasmids from Salmonella sp. using single molecule real-time sequencing on a Pacific Biosciences (Pacbio) RS II Sequencer. We obtained six Salmonella enterica isolates from poultry, representing six different serovars, each exhibiting the MDR-Ampc resistance profile. Salmonella plasmids were obtained using a modified mini preparation and transformed with Escherichia coli DH10Br. A Qiagen Large-Construct kitTM was used to recover highly concentrated and purified plasmid DNA that was sequenced using PacBio technology. These six closed IncA/C plasmids ranged in size from 104 to 191 kb and shared a stable, conserved backbone containing 98 core genes, with only six differences among those core genes. The plasmids encoded a number of antimicrobial resistance genes, including those for quaternary ammonium compounds and mercury. We then compared our six IncA/C plasmid sequences: first with 14 IncA/C plasmids derived from S. enterica available at the National Center for Biotechnology Information (NCBI), and then with an additional 38 IncA/C plasmids derived from different taxa. These comparisons allowed us to build an evolutionary picture of how antimicrobial resistance may be mediated by this common plasmid backbone. Our project provides detailed genetic information about resistance genes in plasmids, advances in plasmid sequencing, and phylogenetic analyses, and important insights about how MDR evolution occurs across diverse serotypes from different animal sources, particularly in agricultural settings where antimicrobial drug use practices vary.

59 BASIC BIOLOGICAL SCIENCES↗

A universal setup for active control of a single-photon detector

The influence of bright light on a single-photon detector has been described in a number of recent publications. The impact on quantum key distribution (QKD) is important, and several hacking experiments have been tailored to fully control single-photon detectors. Special attention has been given to avoid introducing further errors into a QKD system. We describe the design and technical details of an apparatus which allows to attack a quantum-cryptographic connection. This device is capable of controlling free-space and fiber-based systems and of minimizing unwanted clicks in the system. With different control diagrams, we are able to achieve a different level of control. The control was initially targeted to the systems using BB84 protocol, with polarization encoding and basis switching using beamsplitters, but could be extended to other types of systems. We further outline how to characterize the quality of active control of single-photon detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of future readout links for the CMS experiment

The Compact Muon Solenoid (CMS) experiment has developed an electrical implementation of the S-LINK64 extension (Simple Link Interface 64 bit) operating at 400 MB/s in order to read out the detector. This paper studies a possible replacement of the existing S-LINK64 implementation by an optical link, based on 10 Gigabit Ethernet in order to fulfil larger throughput, replace aging hardware and simplify an architecture. A prototype transmitter unit has been developed based on the FPGA Altera PCI Express Development Kit with a custom firmware. A standard PC has been acted as receiving unit. The data transfer has been implemented on a stack of protocols: RDP over IP over Ethernet. This allows receiving the data by standard hardware components like PCs or network switches and NICs. The first test proved that basic exchange of the packets between transmitter and receiving unit works. The paper summarizes the status of these studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗