Search NASA⌕ Search

SEARCH · Search NASA

Results for “random processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Controlled Nonlinear Stochastic Delay Equations: Part II: Approximations and Pipe-Flow Representations

This is the second part of a work dealing with key issues that have not been addressed in the modeling and numerical optimization of nonlinear stochastic delay systems. We consider new classes of models, such as those with nonlinear functions of several controls (such as products), each with is own delay, controlled random Poisson measure driving terms, admissions control with delayed retrials, and others. Part I was concerned with issues concerning the class of admissible controls and their approximations, since the classical definitions are inadequate for our models. This part is concerned with transportation equation representations and their approximations. Such representations of nonlinear stochastic delay models have been crucial in the development of numerical algorithms with much reduced memory and computational requirements. The representations for the new models are not obvious and are developed. They also provide a template for the adaptation of the Markov chain approximation numerical methods.

97 MATHEMATICS AND COMPUTING↗

Complex software dedicated for design and simulation of LPCE process for heavy water detritiation

The main purpose of this paper is to present a comprehensive software, SICA, designed to be used in water-hydrogen liquid phase catalytic exchange process (LPCE). The software calculates the water-gas catalytic isotopic exchange process, following the transfer of any H, D or T isotope from water to gas and vice versa. This software is useful for both design and laboratory-based research; the type of the catalytic filling (ordered or random) can be defined for any of these 2 cases, the isotopic calculation being specific to the package type. For the laboratory-based research, the performance of a catalytic packing can be determined by knowing the type and by using experimental results. Performance of the mixed catalytic packing is defined by mass transfer constants for each catalytic and hydrophilic package in that specific arrangement, and also for the isotope whose transfer is studied from one phase to another. Also, it has been established a link between these constants and commonly used parameters for the fillings performance defined by HETP (Height Equivalent of Theoretical Plate). To demonstrate the performance of the software, we present a comparative analysis of water-gas catalytic isotopic exchange on a column equipped with 3 types of filling: successive layers, random and structured (ordered package filled with catalyst). The program can be used for the LPCE process calculation, process used at detritiation facilities for CANDU reactors or fusion reactors. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discrete One-Dimensional Coverage Process on a Renewal Process

Consider the following coverage model on ℕ, for each site i∈ℕ associate a pair (ξ{sub i},R{sub i}) where (ξ{sub i}){sub i≥0} is a 1-dimensional undelayed discrete renewal point process and (R{sub i}){sub i≥0} is an i.i.d. sequence of ℕ-valued random variables. At each site where ξ{sub i}=1 start an interval of length R{sub i}. Coverage occurs if every site of ℕ is covered by some interval. We obtain sharp conditions for both, positive and null probability of coverage. As corollaries, we extend results of the literature of rumor processes and discrete one-dimensional Boolean percolation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Delay-induced stochastic bifurcations in a bistable system under white noise

In this paper, the effects of noise and time delay on stochastic bifurcations are investigated theoretically and numerically in a time-delayed Duffing-Van der Pol oscillator subjected to white noise. Due to the time delay, the random response is not Markovian. Thereby, approximate methods have been adopted to obtain the Fokker-Planck-Kolmogorov equation and the stationary probability density function for amplitude of the response. Based on the knowledge that stochastic bifurcation is characterized by the qualitative properties of the steady-state probability distribution, it is found that time delay and feedback intensity as well as noise intensity will induce the appearance of stochastic P-bifurcation. Besides, results demonstrated that the effects of the strength of the delayed displacement feedback on stochastic bifurcation are accompanied by the sensitive dependence on time delay. Furthermore, the results from numerical simulations best confirm the effectiveness of the theoretical analyses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seed classification with random forest models

Premise: To improve forest conservation monitoring, we developed a protocol to automatically count and identify the seeds of plant species with minimal resource requirements, making the process more efficient and less dependent on human operators. Methods and Results: Seeds from six North American conifer tree species were separated from leaf litter and imaged on a flatbed scanner. In the most successful species-classification approach, an ImageJ macro automatically extracted measurements for random forest classification in the software R. The method allows for good classification accuracy, and the same process can be used to train the model on other species. Conclusions: This protocol is an adaptable tool for efficient and consistent identification of seed species or potentially other objects. Automated seed classification is efficient and inexpensive, making it a practical solution that enhances the feasibility of large-scale monitoring projects in conservation biology.

59 BASIC BIOLOGICAL SCIENCES↗

Flow Intermittency, Dispersion, and Correlated Continuous Time Random Walks in Porous Media

We study the intermittency of fluid velocities in porous media and its relation to anomalous dispersion. Lagrangian velocities measured at equidistant points along streamlines are shown to form a spatial Markov process. As a consequence of this remarkable property, the dispersion of fluid particles can be described by a continuous time random walk with correlated temporal increments. This new dynamical picture of intermittency provides a direct link between the microscale flow, its intermittent properties, and non-Fickian dispersion.

Environmental Molecular Sciences Laboratory↗

Effect of a magnetic field on polarisation of light in an optical fibre with a random distribution of linear birefringence

A numerical model is proposed to describe the evolution of polarisation of a light wave propagating through a telecommunication fibre with random linear birefringence in a magnetic field. As a result of statistical processing of a set of numerical simulation results, a convenient phenomenological formula is obtained for the first time for the dependence of the average value of the polarisation rotation angle on the magnetic field, the fibre parameters and its length. It is found that the average value of the polarisation rotation angle in a long telecommunication fibre in the representation of the Stokes vectors linearly depends on the applied longitudinal magnetic field (as in the classical Faraday effect for an isotropic medium) but is proportional to the root of the fibre length. It is theoretically shown and experimentally confirmed that the polarisation rotation angle for an extended segment of a telecommunication fibre (50 km) is two orders of magnitude less than that for an isotropic fibre of the same length and material. (optical fibres)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

Cascade random-quasi-phase-matched harmonic generation in polycrystalline ZnSe

Here, we experimentally and numerically investigated the cascade random-quasi-phase-matched harmonic generation in polycrystalline zinc selenide with tightly focused mid-infrared nanosecond laser pulses. We observed a sharp transition between two distinct intensity scaling regimes as a function of pump energy from sub I N to super I N , where I is the pump intensity and N is the harmonic order. To gain an understanding of the observations of this complex nonlinear process, we carried out simulations of the coupled three-wave mixing equations with random grain sizes and orientations. We found a grain size dependence of the effective phase-matching condition, suggesting that manipulation of grain size can be an effective pathway to phase-matching optimization. This approach may provide a framework for effectively enhancing high harmonic generation and other wave mixing effects in polycrystalline materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the uncertainty of synchrotron-based lattice strain measurements

Crystallographic lattice strains - measured using diffraction techniques - are the same magnitude as typical macroscopic elastic strains. From a research perspective, the main interest is in measuring changes in lattice strains induced during in-situ loading: either from one macroscopic stress level to another or from one cycle to the next. The hope is to link these measurements to deformation-induced changes in the internal structure of crystals, possibly related to inelastic deformation and damage. These measurements are relatively new - little experimental intuition exists and it is difficult to discern whether observed differences are due to actual micromechanical evolution or to random experimental fluctuations. If the measurements are linked to material evolution on the size scale of the individual crystal, they have the potential to change the ideas about grain scale deformation partitioning processes and can be used to validate crystal-based simulation frameworks. Therefore, understanding the uncertainty associated with the lattice strain experiments is a crucial step in their continued development. If the measured lattice strains are of the same order as the random fluctuations that are part of the measurement process, documenting the strains can create more confusion than understanding. Often lattice strain error is quoted as {+-}1 x 10{sup -4}. This simple value fails to account for the range of factors that contribute to the experimental uncertainty - which, if not properly accounted for, may lead to a false confidence in the measurements. The focus of this paper is the development of a lattice strain uncertainty expression that delineates the contributing factors into terms that vary independently: (i) the contribution from the instrument and (ii) the contribution from the material under investigation. These aspects of uncertainty are described, and it is then possible to employ a calibrant powder method (diffraction from an unstrained material with high-precision lattice constants) to quantify the instrument portion of the lattice strain uncertainty. In these experiments, the instrument contribution to the uncertainty has been found to be a function of the Bragg angle and the intensity of the diffracted peaks. To develop a model for the instrument portion of the lattice strain uncertainty two datasets obtained using a MAR345 online image plate at the Cornell High Energy Synchrotron Source and a GE 41RT amorphous silicon detector at the Advanced Photon Source have been examined.

43 PARTICLE ACCELERATORS↗

GANISP (GAN-assisted Importance SPlitting)

Genealogical importance splitting marches towards a rare event by iteratively selecting and replicating realizations that are headed towards a rare event. The replication step is made difficult when applied to deterministic systems as the initial conditions of the offspring realizations need to be adjusted. Typically, a random perturbation is applied to the offspring. For some cases, this cloning technique may not be adequate and prevent variance reduction in the probability estimate. A GAN-based replication process is proposed to address this limitation. The perturbations applied to the clones are physically consistent instead of being randomly chosen. The proposed method allows reducing the variance in the probability estimation.

Hassanaly, Malik↗

OBSERVATIONAL SIGNATURES OF CORONAL LOOP HEATING AND COOLING DRIVEN BY FOOTPOINT SHUFFLING

The evolution of a coronal loop is studied by means of numerical simulations of the fully compressible three-dimensional magnetohydrodynamic equations using the HYPERION code. The footpoints of the loop magnetic field are advected by random motions. As a consequence, the magnetic field in the loop is energized and develops turbulent nonlinear dynamics characterized by the continuous formation and dissipation of field-aligned current sheets: energy is deposited at small scales where heating occurs. Dissipation is nonuniformly distributed so that only a fraction of the coronal mass and volume gets heated at any time. Temperature and density are highly structured at scales that, in the solar corona, remain observationally unresolved: the plasma of our simulated loop is multithermal, where highly dynamical hotter and cooler plasma strands are scattered throughout the loop at sub-observational scales. Numerical simulations of coronal loops of 50,000 km length and axial magnetic field intensities ranging from 0.01 to 0.04 T are presented. To connect these simulations to observations, we use the computed number densities and temperatures to synthesize the intensities expected in emission lines typically observed with the Extreme Ultraviolet Imaging Spectrometer on Hinode. These intensities are used to compute differential emission measure distributions using the Monte Carlo Markov Chain code, which are very similar to those derived from observations of solar active regions. We conclude that coronal heating is found to be strongly intermittent in space and time, with only small portions of the coronal loop being heated: in fact, at any given time, most of the corona is cooling down.

79 ASTRONOMY AND ASTROPHYSICS↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

DESPERATE: A Python Library for Processing and Denoising NMR Spectra

NMR spectroscopy is an inherently insensitive technique with respect to the amount of observable signal. A common element in all NMR spectra is random thermal noise that is often characterized by a signal-to-noise ratio (SNR). SNR can be generically improved experimentally with repetitive signal averaging or during post-processing with apodization; the former of which often results in long experimental times and the latter results in the loss of spectral resolution. Denoising techniques can instead be used during post-processing to enhance SNR without compromising resolution. The most common approach relies on the singular-value decomposition (SVD) to discard noisy components of NMR data. SVD-based approaches work well, such as Cadzow and PCA, but are computationally expensive when used for large datasets that are often encountered in NMR (e.g., Carr-Purcell/Meiboom-Gill and nD datasets). Herein, we describe the implementation of a new wavelet transform (WT) routine for the fast and robust denoising of 1D and 2D NMR spectra. Several simulated and experimental datasets are denoised with both SVD-based Cadzow or PCA and WT’s, and the resulting SNR enhancements and spectral uniformity are compared. WT denoising offers similar and improved denoising compared with SVD and operates faster by several orders-of-magnitude in some cases. Further, all denoising and processing routines used in this work are included in a free and open-source Python library called DESPERATE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-56: A Novel Approach to Computing Expected Value and Variance of Point Dose From Non-Gated Radiotherapy Delivery

Purpose: Randomness in patient internal organ motion phase at the beginning of non-gated radiotherapy delivery may introduce uncertainty to dose received by the patient. Concerns of this dose deviation from the planned one has motivated many researchers to study this phenomenon although unified theoretical framework for computing it is still missing. This study was conducted to develop such framework for analyzing the effect. Methods: Two reasonable assumptions were made: a) patient internal organ motion is stationary and periodic; b) no special arrangement is made to start a non -gated radiotherapy delivery at any specific phase of patient internal organ motion. A statistical ensemble was formed consisting of patient’s non-gated radiotherapy deliveries at all equally possible initial organ motion phases. To characterize the patient received dose, statistical ensemble average method is employed to derive formulae for two variables: expected value and variance of dose received by a patient internal point from a non-gated radiotherapy delivery. Fourier Series was utilized to facilitate our analysis. Results: According to our formulae, the two variables can be computed from non-gated radiotherapy generated dose rate time sequences at the point’s corresponding locations on fixed phase 3D CT images sampled evenly in time over one patient internal organ motion period. The expected value of point dose is simply the average of the doses to the point’s corresponding locations on the fixed phase CT images. The variance can be determined by time integration in terms of Fourier Series coefficients of the dose rate time sequences on the same fixed phase 3D CT images. Conclusion: Given a non-gated radiotherapy delivery plan and patient’s 4D CT study, our novel approach can predict the expected value and variance of patient radiation dose. We expect it to play a significant role in determining both quality and robustness of patient non-gated radiotherapy plan.

60 APPLIED LIFE SCIENCES↗

A method for patient dose reduction in dynamic contrast enhanced CT study

Purpose: In dynamic contrast enhanced CT (DCE-CT) study, prolonged CT scanning with high temporal resolution is required to give accurate and precise estimates of kinetic parameters. However, such scanning protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce radiation dose to patient, while maintaining high accuracy for kinetic parameter estimates in DCE-CT study. Methods: The method is based on a previous investigation that the arterial impulse response (AIR) in DCE-CT study can be predicted using a population-based scheme. In the proposed method, DCE-CT scanning is performed with relatively low temporal resolution, hence, giving rise to reduction in patient dose. A novel method is proposed to estimate the arterial input function (AIF) based on the coarsely sampled AIF. By using the estimated AIF in the tracer kinetic analysis of the coarsely sampled DCE-CT study, the calculated kinetic parameters are able to achieve a high degree of accuracy. The method was tested on a DCE-CT data set of 48 patients with cervical cancer scanned at high temporal resolution. A random cohort of 34 patients was chosen to construct the orthonormal bases of the AIRs via singular value decomposition method. The determined set of orthonormal bases was used to fit the AIFs in the second cohort (14 patients) at varying levels of down sampling. For each dataset in the second cohort, the estimated AIF was used for kinetic analyses of the modified Tofts and adiabatic tissue homogeneity models for each of the down-sampling schemes between intervals from 2 to 15 s. The results were compared with analyses done with the ''raw'' down-sampled AIF. Results: In the first group of 34 patients, there were 11 orthonormal bases identified to describe the AIRs. The AIFs in the second group were estimated in high accuracy based on the 11 orthonormal bases established in the first group along with down-sampled AIFs. Using the 11 orthonormal bases, the estimated AIFs for the second group were found to have an averaged maximal percentage error of 3.4%{+-} 7.5% in all sampling schemes up to 15 s. The results of kinetic analysis with the proposed method compared with down sampling alone showed that the proposed method is superior in maintaining the accuracy in volume transfer constant (K{sup trans} ) after 9 s down-sampling interval, blood volume (v{sub b} ) for almost all down-sampling intervals, and blood flow (F) after 11 s down-sampling interval. The preliminary results suggested that the proposed method is able to support scanning intervals of 10-15 s at a cost of 6.2%-10.0% loss in accuracy of K{sup trans} and 10.9%-19.4% in v{sub b}, and the scanning intervals of 12-15 s at a cost of 9.7%-14.6% for F in DEC-CT studies for patients with cervix cancer. Conclusions: The proposed method of AIF estimation allows low scanning frequency in DCE-CT study to reduce radiation dose to patient, while maintaining relatively high accuracy in the kinetic parameter estimates. The initial results suggested that the method is applicable for DCE-CT studies for patients with cervical cancer.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-05: Development of an Ultra-Fast High Quality Whole Breast Radiotherapy Treatment Planning System

Purpose: To enable near-real-time (<20sec) and interactive planning without compromising quality for whole breast RT treatment planning using tangential fields. Methods: Whole breast RT plans from 20 patients treated with single energy (SE, 6MV, 10 patients) or mixed energy (ME, 6/15MV, 10 patients) were randomly selected for model training. Additional 20 cases were used as validation cohort. The planning process for a new case consists of three fully automated steps:1. Energy Selection. A classification model automatically selects energy level. To build the energy selection model, principle component analysis (PCA) was applied to the digital reconstructed radiographs (DRRs) of training cases to extract anatomy-energy relationship.2. Fluence Estimation. Once energy is selected, a random forest (RF) model generates the initial fluence. This model summarizes the relationship between patient anatomy’s shape based features and the output fluence. 3. Fluence Fine-tuning. This step balances the overall dose contribution throughout the whole breast tissue by automatically selecting reference points and applying centrality correction. Fine-tuning works at beamlet-level until the dose distribution meets clinical objectives. Prior to finalization, physicians can also make patient-specific trade-offs between target coverage and high-dose volumes.The proposed method was validated by comparing auto-plans with manually generated clinical-plans using Wilcoxon Signed-Rank test. Results: In 19/20 cases the model suggested the same energy combination as clinical-plans. The target volume coverage V100% was 78.1±4.7% for auto-plans, and 79.3±4.8% for clinical-plans (p=0.12). Volumes receiving 105% Rx were 69.2±78.0cc for auto-plans compared to 83.9±87.2cc for clinical-plans (p=0.13). The mean V10Gy, V20Gy of the ipsilateral lung was 24.4±6.7%, 18.6±6.0% for auto plans and 24.6±6.7%, 18.9±6.1% for clinical-plans (p=0.04, <0.001). Total computational time for auto-plans was < 20s. Conclusion: We developed an automated method that generates breast radiotherapy plans with accurate energy selection, similar target volume coverage, reduced hotspot volumes, and significant reduction in planning time, allowing for near-real-time planning.

60 APPLIED LIFE SCIENCES↗

Arbitrarily small amounts of correlation for arbitrarily varying quantum channels

As our main result show that in order to achieve the randomness assisted message and entanglement transmission capacities of a finite arbitrarily varying quantum channel it is not necessary that sender and receiver share (asymptotically perfect) common randomness. Rather, it is sufficient that they each have access to an unlimited amount of uses of one part of a correlated bipartite source. This access might be restricted to an arbitrary small (nonzero) fraction per channel use, without changing the main result. We investigate the notion of common randomness. It turns out that this is a very costly resource – generically, it cannot be obtained just by local processing of a bipartite source. This result underlines the importance of our main result. Also, the asymptotic equivalence of the maximal- and average error criterion for classical message transmission over finite arbitrarily varying quantum channels is proven. At last, we prove a simplified symmetrizability condition for finite arbitrarily varying quantum channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗