Search NASA⌕ Search

SEARCH · Search NASA

Results for “random response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Information and display requirements for aircraft terrain following

The display design procedure for manned vehicle systems, is applied and validated, for a particular scenario. The scenario chosen is that of zero visibility high speed terrain following (V = 466 ft/sec, H = 200 ft) with an A-10 aircraft. The longitudal (linearized) dynamics are considered. The variations in (command path over) terrain pi(t) are modeled as a third order random process. The display design methodology is based on the optimal control model of pilot response, and employs this model in various ways in different phases of the design process. The overall methodology indicates that the design process is intended as a precursor to manned simulation. It provides a rank ordering of candidate displays through a three level process.

Kleinman, D. L.↗

Structure-borne noise transmission in stiffened structures

The structure-borne noise transmission of stiffened and interconnected structures under random loads is presented. The method is based on the transfer matrix for the structural response and on the modal decomposition for the interior acoustic field. The acoustic enclosure is taken to be rectangular in shape of which portion of the boundaries are elastic while the remaining surface is acoustically rigid. Numerical results are presented for several acousto-structural problems.

Vaicaitis, Rimas↗

Structure-borne noise generation and transmission

The structure-borne noise generation and transmission of stiffened and interconnected structures under random loads is presented. The method is based on the transfer matrix for the structural response and on the modal decomposition for the interior acoustic field. The acoustic enclosure is taken to be rectangular in shape of which portion of the boundaries are elastic while the remaining surface is acoustically rigid. Numerical results are presented for a variety of acousto-structural problems.

Lyrintzis, Constantinos S.↗

Imaging the sun in hard x rays using Fourier telescopes

For several years, solar flares have been observed with a variety of instruments confirming that tremendous amounts of energy are locally stored in the solar magnetic field and then rapidly released during the life of the flare. In concert with observations, theorists have attempted to describe the means by which these energetic events occur and evolve. Two competing theories have emerged and have stood the test of time. One theory describes the flare in terms of nonthermal, electron beam injection into a thick target while the other uses a thermal approach. Both theories provide results which are reasonably consistent with current observations; but to date, none have been able to provide conclusive evidence as to the validity of either model. Imaging on short time scales (1 s) and/or small size scales (1 arc s) should give definitive answers to these questions. In order to test whether a realistic telescope can indeed discriminate between models, we construct model sources based upon the thermal and the nonthermal models and calculate the emission as a function of time and energy in the range from 10 to 100 keV. In addition, we construct model telescopes representing both the spatial modulation collimator (SMC) and the rotating modulation collimator (RMC) techniques of observation using random photon counting statistics. With these two types of telescopes we numerically simulate the instrument response to the above two model flares to see if there are distinct x-ray signatures which may be discernable. We find that theoretical descriptions of the primary models of solar flares do indeed predict different hard x-ray signatures for 1 sec time scales and at 1-5 arc sec spatial resolution. However, these distinguishing signatures can best be observed early in the impulsive phase and from a position perpendicular to the plane of the loop. Furthermore, we find that Fourier telescopes with reasonable and currently attainable design characteristics can image these signatures and that the same sensitive areas and short temporal integration times relative to source evolution (i.e., 1 s), the RMC and the SMC will both provide about the same performance.

Campbell, J. W.↗

Probabilistic Physics-Based Risk Tools Used to Analyze the International Space Station Electrical Power System Output

This paper describes the methods employed to apply probabilistic modeling techniques to the International Space Station (ISS) power system. These techniques were used to quantify the probabilistic variation in the power output, also called the response variable, due to variations (uncertainties) associated with knowledge of the influencing factors called the random variables. These uncertainties can be due to unknown environmental conditions, variation in the performance of electrical power system components or sensor tolerances. Uncertainties in these variables, cause corresponding variations in the power output, but the magnitude of that effect varies with the ISS operating conditions, e.g. whether or not the solar panels are actively tracking the sun. Therefore, it is important to quantify the influence of these uncertainties on the power output for optimizing the power available for experiments.

Patel, Bhogila M.↗

Supersonic/Hypersonic Laminar Heating Correlations for Rectangular and Impact-Induced Open and Closed Cavities

Impact and debris damage to the Space Shuttle Orbiter Thermal Protection System tiles is a random phenomenon, occurring at random locations on the vehicle surface, resulting in random geometrical shapes that are exposed to a definable range of surface flow conditions. In response to the 2003 Final Report of the Columbia Accident Investigation Board, wind tunnel aeroheating experiments approximating a wide range of possible damage scenarios covering both open and closed cavity flow conditions were systematically tested in hypersonic ground based facilities. These data were analyzed and engineering assessment tools for damage-induced fully-laminar heating were developed and exercised on orbit. These tools provide bounding approximations for the damaged-surface heating environment. This paper presents a further analysis of the baseline, zero-pressure-gradient, idealized, rectangular-geometry cavity heating data, yielding new laminar correlations for the floor-averaged heating, peak cavity endwall heating, and the downstream decay rate. Correlation parameters are derived in terms of cavity geometry and local flow conditions. Prediction Limit Uncertainty values are provided at the 95%, 99% and 99.9% levels of significance. Non-baseline conditions, including non-rectangular geometries and flows with known pressure gradients, are used to assess the range of applicability of the new correlations. All data variations fall within the 99% Prediction Limit Uncertainty bounds. Importantly, both open-flow and closed-flow cavity heating are combined into a single-curve parameterization of the heating predictions, and provide a concise mathematical model of the laminar cavity heating flow field with known uncertainty.

Everhart, Joel L.↗

Green Run Modal Test of the NASA Space Launch System Core Stage

The Core Stage of the new NASA Space Launch System (SLS) is a 212-foot tall rocket assembly—consisting primarily of two fuel tanks, an engine section, and four RS-25 rocket engines—capable of sending crew and large payloads to the moon and beyond with 1.6 million pounds of thrust. Currently, the Core Stage is in the B2 Test Stand at Stennis Space Center, undergoing a series of structural and functional tests, designated the Green Run test series. The ultimate goal of Green Run is to verify analytical models and confirm proper subsystem operation of the Core Stage. In January 2020, Green Run testing began with an experimental modal analysis test performed by the Marshal Space Flight Center modal test team. The desired free boundary condition of the Core Stage was achieved by suspending the massive spacecraft from the B2 Test Stand crane. Modal excitation was provided by a pair of 250-lb electro-dynamic shakers for multi-shaker random vibration testing, as well as a 12-pound impact hammer for impact testing. Modal response was measured with 550 accelerometers channels distributed on both the Core Stage and the B2 Test Stand crane. Following one very long night of testing, frequency response functions were calculated from the measured time histories in the target mode frequency range of 2.5 Hz to 15 Hz, and mode shapes, frequencies, and damping values were successfully extracted. The case-study presented in this paper will discuss the SLS Core Stage, the modal test setup and procedure, as well as a brief overview of the test results. Challenges associated with testing such a large, suspended structure in an outdoor environment will be discussed as well.

Green Run↗

Green Run Modal Test of the NASA Space Launch System Core Stage

The Core Stage of the new NASA Space Launch System (SLS) is a 212-foot-tall rocket assembly—consisting primarily of two cryogenic propellant tanks, an engine section, and four RS-25 rocket engines—that will send crew and large payloads to the moon and beyond for NASA’s Artemis program. Prior to SLS assembly, the Core Stage completed a series of structural and functional tests in the B-2 Test Stand at Stennis Space Center, designated Green Run. The goal of Green Run was to verify analytical models, confirm proper subsystem operation, and test-fire all four RS-25 engines of the Core Stage. In January 2020, Green Run testing began with an experimental modal analysis test, performed by the Marshal Space Flight Center modal test team. A free-boundary test condition of the Core Stage was simulated as close as possible by suspending the massive launch vehicle from the B-2 Test Stand crane. Modal excitation was provided by a pair of 250-lb electro-dynamic shakers for multi-shaker random vibration testing, as well as a 12-pound instrumented hammer for impact testing. Modal response was measured with 550 accelerometer channels distributed on both the Core Stage and the B-2 Test Stand derrick crane. Following one very long day of testing, frequency response functions were calculated from the measured time histories in the target mode frequency range of 5 Hz to 15 Hz, and mode shapes, frequencies, and damping values were successfully estimated. The case-study presented in this paper will discuss Green Run, the SLS Core Stage, the modal test setup and execution, as well as a brief overview of the test results. Challenges associated with testing such a large, suspended structure in an outdoor environment will be discussed as well.

Space Launch System↗

The interpretation of SN-v signals in terrestrial experiments through the folding procedure

The convolution (folding) procedure is applied in order to explore the response of Zn isotopes to the energy-spectra of the supernova neutrinos. At first, double differential cross sections are calculated in the context of the quasi-particle random phase approximation (QRPA) and, then, the cross sections obtained are folded with reliable energy distributions of supernova neutrino spectra. This leads to folded double, integrated, cumulative and total cross sections describing the nuclear response of the Zn isotopes as supernova neutrino detectors. Preliminary results of convoluted neutral-current neutrino-nucleus cross sections for the {sup 64}Zn isotope are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessing the Uncertainty in QUANTEC's Dose–Response Relation of Lung and Spinal Cord With a Bootstrap Analysis

Purpose: To apply a statistical bootstrap analysis to assess the uncertainty in the dose–response relation for the endpoints pneumonitis and myelopathy reported in the QUANTEC review. Methods and Materials: The bootstrap method assesses the uncertainty of the estimated population-based dose-response relation due to sample variability, which reflects the uncertainty due to limited numbers of patients in the studies. A large number of bootstrap replicates of the original incidence data were produced by random sampling with replacement. The analysis requires only the dose, the number of patients, and the number of occurrences of the studied endpoint, for each study. Two dose–response models, a Poisson-based model and the Lyman model, were fitted to each bootstrap replicate using maximum likelihood. Results: The bootstrap analysis generates a family of curves representing the range of plausible dose–response relations, and the 95% bootstrap confidence intervals give an estimated upper and lower toxicity risk. The curve families for the 2 dose–response models overlap for doses included in the studies at hand but diverge beyond that, with the Lyman model suggesting a steeper slope. The resulting distributions of the model parameters indicate correlation and non-Gaussian distribution. For both data sets, the likelihood of the observed data was higher for the Lyman model in >90% of the bootstrap replicates. Conclusions: The bootstrap method provides a statistical analysis of the uncertainty in the estimated dose–response relation for myelopathy and pneumonitis. It suggests likely values of model parameter values, their confidence intervals, and how they interrelate for each model. Finally, it can be used to evaluate to what extent data supports one model over another. For both data sets considered here, the Lyman model was preferred over the Poisson-based model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Space shuttle ascent flight turbulence response

A totally reusable space shuttle configuration has been analyzed during ascent flight to determine its response to atmospheric turbulence. Responses in the form of booster and orbiter body accelerations and booster wing root shear, bending moment and turque were obtained due to random and quasi-square-wave discrete turbulence. The configuration was also analyzed with booster aerodynamic surfaces removed to simulate an expendable booster. Symmetric and antisymmetric analyses were performed. Propellant sloshing, gust penetration, and automatic control system effects were included. It was found that the symmetric responses were generally higher than the antisymmetric ones. The stability augmentation system tended to lower the booster accelerations in the symmetric case, while increasing the orbiter accelerations.

Source record↗

Probabilistic structural analysis methods for improving Space Shuttle engine reliability

Probabilistic structural analysis methods are particularly useful in the design and analysis of critical structural components and systems that operate in very severe and uncertain environments. These methods have recently found application in space propulsion systems to improve the structural reliability of Space Shuttle Main Engine (SSME) components. A computer program, NESSUS, based on a deterministic finite-element program and a method of probabilistic analysis (fast probability integration) provides probabilistic structural analysis for selected SSME components. While computationally efficient, it considers both correlated and nonnormal random variables as well as an implicit functional relationship between independent and dependent variables. The program is used to determine the response of a nickel-based superalloy SSME turbopump blade. Results include blade tip displacement statistics due to the variability in blade thickness, modulus of elasticity, Poisson's ratio or density. Modulus of elasticity significantly contributed to blade tip variability while Poisson's ratio did not. Thus, a rational method for choosing parameters to be modeled as random is provided.

Boyce, L.↗

Teal Cycle Ergometer Vibration Isolation and Stabilization System Human-in-the-Loop Ground Evaluation for Long-Duration Spaceflight

Purpose: To counter the deleterious effects of weightlessness on the cardiopulmonary system, astronauts living on the International Space Station exercise on a variety of countermeasure equipment including the Cycle Ergometer Vibration Isolation and Stabilization System (CEVIS). Operational since 2001, the onboard CEVIS will be replaced by a new model, known as Teal CEVIS (TC). As a part of ground evaluation, TC hardware underwent human-in-the-loop (HITL) testing to verify the TC hardware produces workloads that elicit physiologic responses comparable to a laboratory cycle ergometer (LAB). Methods: Seven subjects (5 M/2 F) performed submaximal cycle ergometer testing with indirect calorimetry measures on TC and LAB on separate test days. Testing consisted of graded 30 watt increases in workload until subjects reached 85% of age-predicted max heart rate (HR). Exercise outcomes included rate of oxygen uptake (VO2; liters/min), rate of energy expenditure (REE; kcal/min), and HR (beats/min). Linear mixed models (LMM) were fitted to compare VO2, REE, and HR responses between devices across power outputs with fixed effects for power (P) and device (D) and with random effects for subject. LMM effect coefficients (β), std errors (SE), pseudo-partial R2 of effects (pR2), and model likelihood ratio statistics (χ2, Pr(> chisq); α<.05) are provided. Results: LMM main effects for P and D were observed for VO2 (βp=.0107, SE = .0002, pR2=0.97; βd = -0.075, SE = 0.019, pR2=0.14; χ2(1)= 13.57, p<.001), such that VO2 was higher across stages on TC. Main effects of P and D were observed for REE (βp= .0586, SE = 0.001, pR2= 0.97; βd = -0.33208, SE = 0.099, pR2= 0.056; χ2(1)=10.481, p < .01), such that REE was higher across power outputs on TC. A P x D interaction was observed for HR, along with main effects for P and D (βp x d =-0.048, SE = 0.02, pR2=0.048; βp= 0.42, SE = 0.016, pR2=0.87; χ2(1) = 5.398, p = 0.02), such that higher workloads elicited a greater difference in HR between devices. Conclusions: HITL results show, TC elicits greater physiologic responses across power outputs compared to LAB. However, pR2 for device effects show small differences between devices. Therefore, TC can be expected to provide appropriate physiological stimulus across workloads and be considered a reliable tool to mitigate the effects of weightlessness.

Cycle Ergometer Vibration and Isolation System↗

Array of Bolometers for Submillimeter- Wavelength Operation

A feed-horn-coupled monolithic array of micromesh bolometers is undergoing development for use in a photometric camera. The array is designed for conducting astrophysical observations in a wavelength band centered at 350 m. The bolometers are improved versions of previously developed bolometers comprising metalized Si3N4 micromesh radiation absorbers coupled with neutron- transmutation-doped Ge thermistors. Incident radiation heats the absorbers above a base temperature, changing the electrical resistance of each thermistor. In the present array of improved bolometers (see figure), the thermistors are attached to the micromesh absorbers by indium bump bonds and are addressed by use of lithographed, vapor-deposited electrical leads. This architecture reduces the heat capacity and minimizes the thermal conductivity to 1/20 and 1/300, respectively, of earlier versions of these detectors, with consequent improvement in sensitivity and speed of response. The micromesh bolometers, intended to operate under an optical background set by thermal emission from an ambient-temperature space-borne telescope, are designed such that the random arrival of photons ("photon noise") dominates the noise sources arising from the detector and readout electronics. The micromesh is designed to be a highly thermally and optically efficient absorber with a limiting response time of about 100 s. The absorber and thermistor heat capacity are minimized in order to give rapid speed of response. Due to the minimization of the absorber volume, the dominant source of heat capacity arises from the thermistor.

Bock, James↗

Electrically driven deep ultraviolet MgZnO lasers at room temperature

Semiconductor lasers in the deep ultraviolet (UV) range have numerous potential applications ranging from water purification and medical diagnosis to high-density data storage and flexible displays. Nevertheless, very little success was achieved in the realization of electrically driven deep UV semiconductor lasers to date. Here, we report the fabrication and characterization of deep UV MgZnO semiconductor lasers. These lasers are operated with continuous current mode at room temperature and the shortest wavelength reaches 284 nm. The wide bandgap MgZnO thin films with various Mg mole fractions were grown on c-sapphire substrate using radio-frequency plasma assisted molecular beam epitaxy. Metal-semiconductor-metal (MSM) random laser devices were fabricated using lithography and metallization processes. Besides the demonstration of scalable emission wavelength, very low threshold current densities of 29-33 A/cm 2 are achieved. Furthermore, numerical modeling reveals that impact ionization process is responsible for the generation of hole carriers in the MgZnO MSM devices. The interaction of electrons and holes leads to radiative excitonic recombination and subsequent coherent random lasing.

36 MATERIALS SCIENCE↗

A GATE evaluation of the sources of error in quantitative {sup 90}Y PET

Purpose: Accurate reconstruction of the dose delivered by {sup 90}Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with {sup 90}Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of {sup 90}Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom-containing either {sup 90}Y or {sup 18}F were simulated using GATE. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the {sup 90}Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated {sup 90}Y data was slightly poorer than that for simulated {sup 18}F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of {sup 90}Y PET confirm that quantitative {sup 90}Y is achievable with the same approach as that used for {sup 18}F, and that there is likely very little margin for improvement by attempting to model aspects unique to {sup 90}Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Phase III Randomized Trial of the Timing of Meloxicam With Iodine-125 Prostate Brachytherapy

Purpose: Nonsteroidal anti-inflammatory medication is used to reduce prostate edema and urinary symptoms following prostate brachytherapy. We hypothesized that a cyclooxygenase-2 (COX-2) inhibitor regimen started 1 week prior to seed implant might diminish the inflammatory response, thus reducing edema, retention rates, and symptom severity. Methods and Materials: From March 2004 to February 2008, 316 men consented to an institutional review board-approved randomized study of a 4-week course of meloxicam, 7.5 mg orally twice per day, starting either on the day of implant or 1 week prior to implant. Brachytherapy was performed using iodine-125 seeds and was preplanned and performed under transrectal ultrasound (TRUS) and fluoroscopic guidance. Prostate volume obtained by MR imaging at 1 month was compared to baseline prostate volume obtained by TRUS planimetry and expressed as an edema factor. The trial endpoints were prostate edema at 1 month, International Prostate Symptom Score (IPSS) questionnaire results at 1 and 3 months, and any need for catheterization. Results: Results for 300 men were analyzed. Median age was 61 (range, 45-79 years), and median TRUS prostate volume was 35.7 cc (range, 18.1-69.5 cc). Median IPSS at baseline was 5 (range, 0-24) and was 15 at 1 month, 16 at 3 months, and 10 at 6 months. Catheterization was required for 7% of patients (6.2% day 0 arm vs. 7.9% day -7 arm; p = 0.65). The median edema factor at 1 month was 1.02 (range, 0.73-1.7). 1.01 day 0 arm vs. 1.05 day -7 arm. Baseline prostate volume remained the primary predictor of postimplant urinary retention. Conclusions: Starting meloxicam 1 week prior to brachytherapy compared to starting immediately after the procedure did not reduce 1-month edema, improve IPSSs at 1 or 3 months, or reduce the need for catheterization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distinctive Oxidative Stress Responses to Hydrogen Peroxide in Sulfate Reducing Bacteria Desulfovibrio vulgaris Hildenborough

Response of Desulfovibrio vulgaris Hildenborough to hydrogen peroxide (H2O2, 1 mM) was investigated with transcriptomic, proteomic and genetic approaches. Microarray data demonstrated that gene expression was extensively affected by H2O2 with the response peaking at 120 min after H2O2 treatment. Genes affected include those involved with energy production, sulfate reduction, ribosomal structure and translation, H2O2 scavenging, posttranslational modification and DNA repair as evidenced by gene coexpression networks generated via a random matrix-theory based approach. Data from this study support the hypothesis that both PerR and Fur play important roles in H2O2-induced oxidative stress response. First, both PerR and Fur regulon genes were significantly up-regulated. Second, predicted PerR regulon genes ahpC and rbr2 were derepressedin Delta PerR and Delta Fur mutants and induction of neither gene was observed in both Delta PerR and Delta Fur when challenged with peroxide, suggesting possible overlap of these regulons. Third, both Delta PerR and Delta Fur appeared to be more tolerant of H2O2 as measured by optical density. Forth, proteomics data suggested de-repression of Fur during the oxidative stress response. In terms of the intracellular enzymatic H2O2 scavenging, gene expression data suggested that Rdl and Rbr2 may play major roles in the detoxification of H2O2. In addition, induction of thioredoxin reductase and thioredoxin appeared to be independent of PerR and Fur. Considering all data together, D. vulgaris employed a distinctive stress resistance mechanism to defend against increased cellular H2O2, and the temporal gene expression changes were consistent with the slowdown of cell growth at the onset of oxidative stress.

59 BASIC BIOLOGICAL SCIENCES↗