Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Scalable Detector Design for a High-Resolution Fast-Neutron Radiography Panel

Development of a scalable flat-panel neutron radiography device is needed to meet the nondestructive testing needs of a growing industrial market. Flood field images from a Cs-137 gamma source and a Cf-252 fission neutron source were generated using a detector composed of a 3-mm-thick sheet of EJ-200, and 3-mm-thick sheet of acrylic light spreader, an 8 $\times$ 8 array of SensL MICROFJ-60035-TSV SiPMs, and an IDEAS ROSSPAD readout module. The readout module can be tiled together with similar systems to create a panel of any size, and is only limited by the number of available Ethernet ports in a switching system. A collimated gamma line image demonstrated a 90% spatial resolution of approximately 0.47 line pairs per centimeter and a 10% spatial resolution of approximately 2.32 line pairs per centimeter. A neutron edge image demonstrated a 90% spatial resolution of approximately 0.70 line pairs per centimeter and a 10% spatial resolution of approximately 3.35 line pairs per centimeter. Both of these images show the ability to generate radiographs with sub-SiPM spatial resolution. Using these readout modules, a large-scale radiographic panel can be developed by tiling ROSSPAD modules together.

36 MATERIALS SCIENCE↗

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES↗

High-resolution absorption spectroscopy of room-temperature and jet-cooled ammonia between 59,000 and 93,000 cm -1

Here, we present new high-resolution photoabsorption spectra of ammonia spanning the region between 59,000 cm -1 and 93,000 cm -1 that were recorded by using the Fourier Transform Spectrometer at the Synchrotron SOLEIL. This region extends from just above the Franck-Condon envelope for the $\tilde{A}$ 1 $A$ 2 " ← $\tilde{X}$ 1 $A$ 1 ' transition to well above the NH 3 + $\tilde{X}$ + 2 $A$ 2 " ionization threshold. The spectra were recorded at a measured resolution of 0.23 cm -1 in both a room-temperature cell (293 K) and in a slit-jet supersonic expansion (~70 K). The absolute photoabsorption cross section with an uncertainty of ±5% is also reported for the room-temperature spectrum. The present resolution is a factor of 10 – 100 times higher than in other recently reported broad band spectra of ammonia, and many of the observed bands show partially resolved rotational structure. We have attempted to assign this structure for a number of these bands. The oscillator strengths extracted from the data are in good agreement with previous measurements but, in the case of structured bands, the present higher resolution measurements return higher peak absorption cross sections, that increase further when the sample is cooled. The present higher resolution spectra suggest that a number of previous vibronic band assignments that were based on quantum defect considerations may require some revision. Finally, we discuss the substantial differences between the photoabsorption and photoionization data just above the first ionization threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of sub-pixel position resolution with time-correlated transient signals in 3D pixelated CdZnTe detectors with varying pixel sizes

Here, we evaluated the sub-pixel position resolution achievable in large-volume CdZnTe pixelated detectors with conventional pixel patterns and for several different pixel sizes: 2.8 mm, 1.72 mm, 1.4 mm and 0.8 mm. Achieving position resolution below the physical dimensions of pixels (sub-pixel resolution) is a practical path for making high-granularity position-sensitive detectors, <100 μμm, using a limited number of pixels dictated by the mechanical constraints and multi-channel readout electronics. High position sensitivity is important for improving the imaging capability of CZT gamma cameras. It also allows for making more accurate corrections of response non-uniformities caused by crystal defects, thus enabling use of standard-grade (unselected) and less expensive CZT crystals for producing large-volume position-sensitive CZT detectors feasible for many practical applications. We analyzed the digitized charge signals from a representative 9 pixels and the cathode, generated using a pulsed-laser light beam focused down to 10 m (650 nm) to scan over a selected 3×3 pixel area. We applied our digital pulse processing technique to the time-correlated signals captured from adjacent pixels to achieve and evaluate the capability for sub-pixel position resolution. As an example, we also demonstrated an application of 3D corrections to improve the energy resolution and positional information of the events for the tested detectors.

36 MATERIALS SCIENCE↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined effects of horizontal and vertical resolution on reliable turbulence prediction at tidal energy sites: A systematic study in the Salish Sea, WA

Predicting turbulence characteristics with coastal ocean models is essential for tidal energy converter deployment. While large eddy simulation provides a detailed turbulence representation, computational limitations restrict its use to smaller domains. We systematically evaluate whether well-configured coastal models can provide reliable turbulence prediction through progressive refinement of 3D model representation. We implemented four model configurations (Levels 1–4) using terrain-following coordinates, isolating the impacts of horizontal resolution, vertical resolution, and layer distribution. We validated all configurations against field measurements from the Salish Sea, WA. Results show that tidal current velocity predictions remain unchanged regarding model configuration, but turbulence properties are sensitive to resolution refinement. Increasing vertical resolution alone proved insufficient; even with vertical sigma-levels rising from 11 to 41, significant underprediction persisted until finer horizontal resolution better captured bathymetric variations. The Level 4 configuration, incorporating geometric sigma-levels distribution, achieved turbulence prediction skill scores exceeding 0.90. Turbulence closure comparison revealed Mellor- Yamada 2.5 outperformed k-epsilon in TKE prediction (skill scores 0.84–0.94 versus 0.72–0.81) due to better boundary layer parameterization. This study shows that well-configured coastal models effectively bridge the gap between simplified tools and costly high-fidelity modeling, offering the tidal energy industry practical and cost-effective turbulence data at commercially relevant scales.

Marine Energy↗

A high-resolution planetary boundary layer height seasonal climatology from GNSS radio occultations

We present a new seasonal planetary boundary layer height (PBLH) climatology product derived from 14 years of Global Navigation Satellite System radio occultation (GNSS-RO) data from multiple missions including COSMIC, TerraSAR-X, KOMPSAT-5, and PAZ. PBLH estimates are derived from the minimum gradients of retrieved refractivity profiles, with a vertical resolution of ~200 m. The climatology is obtained from occultations observed between June 2006 and December 2019, and is divided into land and ocean regimes on a 2-degree grid. We provide seasonal climatologies at 2-degree resolution as well as climatologies of diurnal cycle amplitude and phase at 5-degree resolution. The new GNSS PBLH climatology is compared to radiosonde data from the ship-based Marine ARM GPCI Investigation of Clouds (MAGIC) campaign in the subtropical northeast Pacific ocean and to previous GNSS PBLH climatology estimates. The higher spatial resolution reveals new details such as seasonal PBLH modulation due to sea ice off the coast of Antarctica. The PBLH product is the first publicly available at 2-degree resolution.

54 ENVIRONMENTAL SCIENCES↗

Estimating snow cover from high-resolution satellite imagery by thresholding blue wavelengths

We report the extent and duration of snow cover, a critical component of the hydrologic cycle and the global climate system, is expected to shift dramatically under climate change. Therefore, developing high-resolution assessments of snow cover change is crucial for estimating the impact of changing snow cover on watershed and ecosystems processes in cold regions. Remote sensing tools provide a powerful method for mapping snow-covered area (SCA) across a landscape. The most common method for estimating SCA utilizes the normalized difference snow index (NDSI), which relies on spectral measurements in the shortwave-infrared wavelengths (SWIR). NDSI can effectively estimate catchment- to regional-scale SCA, but it cannot be used to assess fine-scale SCA because of current limitations on the spatial resolution of satellite-derived SWIR measurements. Here, we map SCA using a threshold of blue wavelengths and high-resolution satellite imagery. The thresholding method, which we call the Blue Snow Threshold algorithm (BST), has previously been used with digital camera imagery. We refine and automate the algorithm for use with cloud-free high-resolution satellite imagery and find that the BST can be used to assess fine-scale SCA. For validation, we compared BST-derived estimates of SCA to a) airborne lidar surveys, b) Landsat fractional SCA, and c) snow disappearance dates from Snow Telemetry (SNOTEL) stations. When compared to airborne lidar surveys of SCA, the BST predicted SCA had a range of F-scores between 0.81 and 0.94 in four study areas in California and Colorado. We also found general agreement between SCA and snow disappearance at multiple SNOTEL sites across the western United States. Given the relatively recent availability of high-resolution satellite imagery with spectral measurements in the visible wavelengths but lacking in SWIR, the BST offers a reliable and easy-to-apply tool for examining fine-scale snow-related processes.

54 ENVIRONMENTAL SCIENCES↗

Carbon sequestration in the uplands of Eastern China: an analysis with high-resolution model simulations

Using the DeNitrification-DeComposition (DNDC, version 9.5) model, we investigated the soil organic carbon (SOC) changes from 1980 to 2009 in Eastern China's upland-crop fields (3.7% of the land area of China) in northern Jiangsu Province. A currently most detailed high-resolution soil database, containing 17,024 polygons at a scale of 1:50,000, derived from 983 unique upland soil profiles, was used. A coarser county-level soil database was also used for a pair-wise simulation for comparison. We found that SOC changes modeled with the county-level soil database differ significantly from those with high-resolution soil data, with the deviation ranging from -64% to 8.0% in different counties. This implies that coarse soil data may lead to large biases in SOC simulation. With the high-resolution database, the model estimates a SOC increase of 37.89 Tg C in the top soils (0-50 cm) over the study area of 3.93 Mha for the past three decades, with an average rate of 322 kg C ha-1 year-1. The SOC accumulation in the study region accounts for 10.2% of annual national carbon sequestration, underscoring its significance to national climate mitigation. The annual SOC change varied between 61 to 519 kg C ha-1 year-1, mainly driven by the variations in N-fertilizer and manure applications. This study highlights the significance of high-resolution soil databases in quantifying SOC changes. Our high-resolution estimates of SOC will support farming and carbon management in this region.

Zhang, Liming↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Ultra-High Resolution Ion Mobility Separations Utilizing Traveling Waves in a 13 m Serpentine Path Length Structures for Lossless Ion Manipulations Module

We report the development and initial evaluation of a 13-m path length Structures for Lossless Manipulations (SLIM) module for achieving high resolution separations using traveling waves (TW) with ion mobility (IM) spectrometry. The TW SLIM module was fabricated using two mirror-image printed circuit boards with appropriately configured RF, DC and TW electrodes and positioned with a 2.75-mm inter-surface gap. Ions were effective confined between the surfaces by RF-generated pseudopotential fields and moved losslessly through a serpentine path including 44 “U” turns using TWs. The ion mobility resolution was characterized at different pressures, gaps between the SLIM surfaces, TW and RF parameters. After initial optimization the SLIM IM-MS module provided about 5-fold higher resolution separations than present commercially available drift tube or traveling wave IM-MS platforms. Peak capacity and peak generation rates achieved were 246 and 370 s-1, respectively, at a TW speed of 148 m/s. The high resolution achieved in the TW SLIM IM-MS enabled e.g., isomeric sugars (Lacto-N-fucopentaose I and Lacto-N-fucopentaose II) to be baseline resolved, and peptides from a albumin tryptic digest much better resolved than with existing commercial IM-MS platforms. The present work also provides a foundation for the development of much higher resolution SLIM devices based upon both considerably longer path lengths and multi-pass designs.

Environmental Molecular Sciences Laboratory↗

Approaching Angstrom-Scale Resolution in Lithography Using Low-Molecular-Mass Resists (<500 Da)

Resists that enable high-throughput and high-resolution patterning are essential in driving the semiconductor technology forward. The ultimate patterning performance of a resist in lithography is limited because of the trade-off between resolution, line-width roughness, and sensitivity; improving one or two of these parameters typically leads to a loss in the third. As the patterned feature sizes approach angstrom scale, the trade-off between these three metrics becomes increasingly hard to resolve and calls for a fundamental rethinking of the resist chemistry. Low-molecular-mass monodispersed metal-containing resists of high atom economy can provide not only very high resolution but also very low line-width roughness without sacrificing sensitivity. Here we describe a modular metal-containing resist platform (molecular mass <500 Da) where a molecular resist consists of just two components: a metal and a radical initiator bonded to it. This simple system not only is amenable to high-resolution electron beam lithography (EBL) and extreme ultraviolet lithography (EUVL) but also unites them mechanistically, giving a consolidated perspective of molecular and chemical processes happening during exposure. Irradiation of the resist leads to the production of secondary electrons that generate radicals in the initiator bonded to metal. This brings about an intramolecular rearrangement and causes solubility switch in the exposed resist. We demonstrate record 1.9–2.0 nm isolated patterns and 7 nm half-pitch dense line-space features over a large area using EBL. With EUVL, 12 nm half-pitch line-space features are shown at a dose of 68 mJ/cm 2 . In both of these patterning techniques, the line-width roughness was found to be ≤2 nm, a record low value for any resist platform, also leading to a low-performance trade-off metric, Z factor, of 0.6 × 10 –8 mJ·nm 3 . With the ultimate resolution limited by instrumental factors, potential patterning at the level of a unit cell can be envisaged, making low-molecular-mass resists best poised for angstrom-scale lithography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Vertical Resolution Impacts Explicit Simulation of Deep Convection

Abstract The aggregation of tropical convection greatly influences the mean‐state of the atmosphere, altering humidity distributions, total atmospheric radiative cooling, and cloud amounts. Although studies have demonstrated the sensitivity of convective aggregation to horizontal resolution and domain size, few studies have explored the impact of vertical resolution on convective aggregation. Here, we investigate the impact of vertical resolution on simulations of deep convection and convective aggregation using the System for Atmospheric Modeling convection resolving model. We analyze simulations of tropical radiative‐convective equilibrium with varying vertical levels (32, 64, 128, and 256) across small (100 km), medium (700 km) and large (1,500 km) domains. We demonstrate that relative humidity and cloud fraction decrease with increasing vertical resolution as a result of reduced turbulent mixing. Vertical resolution also influences the occurrence of, onset time, and equilibrium intensity of aggregated convection, and also appears to affect the sensitivity of convective aggregation to domain size. Understanding how simulated convection aggregates, as well as its simulated sensitivity to model formulation, is critical for making and interpreting future predictions of global climate change.

Meteorology & Atmospheric Sciences↗

In-line three-dimensional holography of nanocrystalline objects at atomic resolution

We report that resolution and sensitivity of the latest generation aberration-corrected transmission electron microscopes allow the vast majority of single atoms to be imaged with sub-Ångstrom resolution and their locations determined in an image plane with a precision that exceeds the 1.9-pm wavelength of 300 kV electrons. Such unprecedented performance allows expansion of electron microscopic investigations with atomic resolution into the third dimension. Here we show a general tomographic method to recover the three-dimensional shape of a crystalline particle from high-resolution images of a single projection without the need for sample rotation. The method is compatible with low dose rate electron microscopy, which improves on signal quality, while minimizing electron beam-induced structure modifications even for small particles or surfaces. Lastly, we apply it to germanium, gold and magnesium oxide particles, and achieve a depth resolution of 1–2 Å, which is smaller than inter-atomic distances.

36 MATERIALS SCIENCE↗

Resolution-enhanced X-ray fluorescence microscopy via deep residual networks

Abstract Multimodal hard X-ray scanning probe microscopy has been extensively used to study functional materials providing multiple contrast mechanisms. For instance, combining ptychography with X-ray fluorescence (XRF) microscopy reveals structural and chemical properties simultaneously. While ptychography can achieve diffraction-limited spatial resolution, the resolution of XRF is limited by the X-ray probe size. Here, we develop a machine learning (ML) model to overcome this problem by decoupling the impact of the X-ray probe from the XRF signal. The enhanced spatial resolution was observed for both simulated and experimental XRF data, showing superior performance over the state-of-the-art scanning XRF method with different nano-sized X-ray probes. Enhanced spatial resolutions were also observed for the accompanying XRF tomography reconstructions. Using this probe profile deconvolution with the proposed ML solution to enhance the spatial resolution of XRF microscopy will be broadly applicable across both functional materials and biological imaging with XRF and other related application areas.

36 MATERIALS SCIENCE↗

Quartz-based flat-crystal resonant inelastic x-ray scattering spectrometer with sub-10 meV energy resolution

Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and technological importance. In particular, RIXS is the only alternative tool to inelastic neutron scattering capable of providing fully momentum resolved information on dynamic spin structures of magnetic materials, but is limited to systems whose magnetic excitation energy scales are comparable to the energy resolution. The state-of-the-art spherical diced crystal analyzer optics provides energy resolution as good as 25 meV but has already reached its theoretical limit. For this study, we demonstrate a novel sub-10 meV RIXS spectrometer based on flat-crystal optics at the Ir-L3 absorption edge (11.215 keV) that achieves an analyzer energy resolution of 3.9 meV, very close to the theoretical value of 3.7 meV. In addition, the new spectrometer allows efficient polarization analysis without loss of energy resolution. The performance of the instrument is emonstrated using longitudinal acoustical and optical phonons in diamond, and magnon in Sr 3 Ir 2 O 7 . The novel sub-10 meV RIXS spectrometer thus provides a window into magnetic materials with small energy scales.

36 MATERIALS SCIENCE↗

Multiscale in-situ characterization of static recrystallization using dark-field X-ray microscopy and high-resolution X-ray diffraction

Abstract Dark-field X-ray microscopy (DFXM) is a high-resolution, X-ray-based diffraction microstructure imaging technique that uses an objective lens aligned with the diffracted beam to magnify a single Bragg reflection. DFXM can be used to spatially resolve local variations in elastic strain and orientation inside embedded crystals with high spatial (~ 60 nm) and angular (~ 0.001°) resolution. However, as with many high-resolution imaging techniques, there is a trade-off between resolution and field of view, and it is often desirable to enrich DFXM observations by combining it with a larger field-of-view technique. Here, we combine DFXM with high-resolution X-ray diffraction (HR-XRD) applied to an in-situ investigation of static recrystallization in an 80% hot-compressed Mg–3.2Zn–0.1Ca wt.% (ZX30) alloy. Using HR-XRD, we track the relative grain volume of > 8000 sub-surface grains during annealing in situ. Then, at several points during the annealing process, we “zoom in” to individual grains using DFXM. This combination of HR-XRD and DFXM enables multiscale characterization, used here to study why particular grains grow to consume a large volume fraction of the annealed microstructure. This technique pairing is particularly useful for small and/or highly deformed grains that are often difficult to resolve using more standard diffraction microstructure imaging techniques.

36 MATERIALS SCIENCE↗

Unified treatment and measurement of the spectral resolution and temporal effects in frequency-resolved sum-frequency generation vibrational spectroscopy (SFG-VS)

The emergence of sub-wavenumber high-resolution broadband sum-frequency generation vibrational spectroscopy (HR-BBSFG-VS) [Velarde et al., J. Chem. Phys., 2011, 135, 241102] has offered new opportunities in obtaining and understanding the spectral lineshape and temporal effects on the surface vibrational spectroscopy. Particularly, the high accuracy in the HR-BBSFG-VS spectral lineshape measurement provides detailed information on the complex coherent vibrational dynamics through spectral measurement. Here we present a unified formalism of the theoretical and experimental approaches for obtaining the accurate lineshape of the SFG response, and then present a analysis on the higher and lower spectral resolution SFG spectra as well as their temporal effects of the cholesterol molecules at the air/water interface. With the high spectral resolution and accurate lineshape, it is shown that the parameters from the sub-wavenumber resolution SFG spectra can be used not only to understand but also to quantitatively reproduce the temporal effects in the lower resolution SFG measurement. These not only provide a unified picture in understanding both the frequency-domain and the time-domain SFG response of the complex molecular interface, but also provide novel experimental approaches that can directly measure them.

Environmental Molecular Sciences Laboratory↗