Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

An investigation of structural, magnetic and dielectric properties of R{sub 2}NiMnO{sub 6} (R = rare earth, Y)

We have investigated the structure, magnetic and dielectric properties of the double perovskite oxides, R{sub 2}NiMnO{sub 6} (R = Pr, Nd, Sm, Gd, Tb, Dy, Ho and Y). We could refine powder X-ray diffraction patterns of all the phases on the basis of monoclinic (P2{sub 1}/n) double perovskite structure where Ni and Mn atoms are ordered at 2c and 2d sites, respectively. All the phases are ferromagnetic insulators exhibiting relatively low dielectric loss and dielectric constants in the range 15-25. The ferromagnetic ordering temperature of the R{sub 2}NiMnO{sub 6} series seems to correlate better with the radius of R{sup 3+} atoms than with the average Ni-O-Mn angle ({phi}) in the double perovskite structure. These results are consistent with all samples having Mn{sup 4+} and Ni{sup 2+} with minimal antisite disorder.

36 MATERIALS SCIENCE↗

Metabolomics approaches for discovering biomarkers of drug-induced hepatotoxicity and nephrotoxicity

Hepatotoxicity and nephrotoxicity are two major reasons that drugs are withdrawn post-market, and hence it is of major concern to both the FDA and pharmaceutical companies. The number of cases of serious adverse effects (SAEs) in marketed drugs has climbed faster than the number of total drug prescriptions issued. In some cases, preclinical animal studies fail to identify the potential toxicity of a new chemical entity (NCE) under development. The current clinical chemistry biomarkers of liver and kidney injury are inadequate in terms of sensitivity and/or specificity, prompting the need to discover new translational specific biomarkers of organ injury. Metabolomics along with genomics and proteomics technologies have the capability of providing translational diagnostic and prognostic biomarkers specific for early stages of liver and kidney injury. Metabolomics has several advantages over the other omics platforms such as ease of sample preparation, data acquisition and use of biofluids collected through minimally invasive procedures in preclinical and clinical studies. The metabolomics platform is reviewed with particular emphasis on applications involving drug-induced hepatotoxicity and nephrotoxicity. Analytical platforms for metabolomics, chemometrics for mining metabolomics data and the applications of the metabolomics technologies are covered in detail with emphasis on recent work in the field.

60 APPLIED LIFE SCIENCES↗

Reexamination of hydrodynamic phonon transport in thin graphite

The recent hydrodynamic phonon transport theory for graphitic materials has been supported by the measurements of the second sound at temperatures up to about 100 K. When boundary scattering becomes comparable to momentum-conserving normal phonon scattering processes that are responsible for phonon hydrodynamics, Poiseuille phonon flow phenomena can emerge to give rise to unique size-dependent thermal conductivity in thin graphite. Here, we examine the thickness range for the Poiseuille phonon flow to become observable in thin graphite with the use of both deviational Monte Carlo simulation of the Peierls-Boltzmann transport equation and four-probe thermal transport measurements. As the basal-plane thermal conductivity calculated by prior first-principles theories saturates to the graphite value when the thickness is increased to five graphene layers, the phonon dispersion of graphite is used in the current calculations of thin graphite of micrometer thickness and a 23-layer thick ultrathin graphite (UTG) sample. The calculations show that diffuse surface scattering by surface defects can lead to Poiseuille phonon flow at 50 K in thin graphite with the thickness close to several micrometers but not in the 65 μm thin graphite and 23-layer UTG, where phonon scattering by the top and bottom surfaces become, respectively, much less and more frequent than the normal processes. In addition, the calculation results with the bulk graphite dispersion and diffuse surface scattering show decreased basal-plane thermal conductivity with decreasing thickness, opposite to recent thermocouple measurements of thin graphite samples. In comparison, the calculation results reveal that partially diffuse surface defect scattering can yield the four-probe measurement results of UTG samples, which are prepared here with an improved process to minimize surface contamination.

36 MATERIALS SCIENCE↗

HST/WFC3 CONFIRMATION OF THE INSIDE-OUT GROWTH OF MASSIVE GALAXIES AT 0 < z < 2 AND IDENTIFICATION OF THEIR STAR-FORMING PROGENITORS AT z {approx} 3

We study the structural evolution of massive galaxies by linking progenitors and descendants at a constant cumulative number density of n{sub c} = 1.4 Multiplication-Sign 10{sup -4} Mpc{sup -3} to z {approx} 3. Structural parameters were measured by fitting Sersic profiles to high-resolution CANDELS HST WFC3 J{sub 125} and H{sub 160} imaging in the UKIDSS-UDS at 1 < z < 3 and ACS I{sub 814} imaging in COSMOS at 0.25 < z < 1. At a given redshift, we selected the HST band that most closely samples a common rest-frame wavelength so as to minimize systematics from color gradients in galaxies. At fixed n{sub c}, galaxies grow in stellar mass by a factor of {approx}3 from z {approx} 3 to z {approx} 0. The size evolution is complex: galaxies appear roughly constant in size from z {approx} 3 to z {approx} 2 and then grow rapidly to lower redshifts. The evolution in the surface mass density profiles indicates that most of the mass at r < 2 kpc was in place by z {approx} 2, and that most of the new mass growth occurred at larger radii. This inside-out mass growth is therefore responsible for the larger sizes and higher Sersic indices of the descendants toward low redshift. At z < 2, the effective radius evolves with the stellar mass as r{sub e} {proportional_to}M {sup 2.0}, consistent with scenarios that find dissipationless minor mergers to be a key driver of size evolution. The progenitors at z {approx} 3 were likely star-forming disks with r{sub e} {approx} 2 kpc, based on their low Sersic index of n {approx} 1, low median axis ratio of b/a {approx} 0.52, and typical location in the star-forming region of the U - V versus V - J diagram. By z {approx} 1.5, many of these star-forming disks disappeared, giving rise to compact quiescent galaxies. Toward lower redshifts, these galaxies continued to assemble mass at larger radii and became the local ellipticals that dominate the high-mass end of the mass function at the present epoch.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-ray bursts trace UV metrics of star formation over 3 < z < 5

We present the first uniform treatment of long duration gamma-ray burst (GRB) host galaxy detections and upper limits over the redshift range 3 −15.6 mag, and with extrapolations of the assumed Schechter-type LF well beyond this range. We review proposed astrophysical and observational biases for our sample, and find that they are for the most part minimal. We therefore conclude, as the simplest interpretation of our results, that GRBs successfully trace UV metrics of cosmic SF over the range 3<z<5. Our findings suggest that GRBs provide an accurate picture of star formation processes from z≈3 out to the highest redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Approaching the intrinsic photoluminescence linewidth in transition metal dichalcogenide monolayers

Excitonic states in monolayer transition metal dichalcogenides (TMDCs) have been the subject of extensive recent interest. Their intrinsic properties can, however, be obscured due to the influence of inhomogeneity in the external environment. Here we report methods for fabricating high quality TMDC monolayers with narrow photoluminescence (PL) linewidth approaching the intrinsic limit. We find that encapsulation in hexagonal boron nitride (h-BN) sharply reduces the PL linewidth, and that passivation of the oxide substrate by an alkyl monolayer further decreases the linewidth and also minimizes the charged exciton (trion) peak. The combination of these sample preparation methods results in much reduced spatial variation in the PL emission, with a full-width-at-half-maximum as low as 1.7 meV. Furthermore, analysis of the PL line shape yields a homogeneous width of 1.43 ± 0.08 meV and inhomogeneous broadening of 1.1 ± 0.3 meV.

36 MATERIALS SCIENCE↗

Role of the likelihood for elastic scattering uncertainty quantification

In the last decade, uncertainty quantification (UQ) for optical model potentials (OMPs) has become a focal point for nuclear reaction theory, and several competing approaches for OMP UQ have recently been developed. Here, we clarify recent efforts to compare frequentist and Bayesian approaches in the context of OMP UQ [G. B. King et al., Phys. Rev. Lett. 122, 232502 (2019)]. We replicate a portion of that OMP UQ study but use independent statistical tools. Specifically, we compare two methods for OMP parameter inference from elastic scattering data: the Levenberg-Marquardt algorithm for χ 2 minimization on one hand and Markov chain Monte Carlo (MCMC) sampling on the other. Separately, we assess the common practice of using a renormalized likelihood (χ 2 /N), N being the number of data points, instead of the canonical weighted-least-squares likelihood (χ 2 ), as a way of accounting for unknown data correlations. Here, we show that for a generic linear model and for a five-parameter OMP analysis, frequentist and uniform-prior Bayesian approaches recover the same optimum and uncertainty estimates—not systematically larger uncertainties for the Bayesian approach, as was concluded in G. B. King et al., Phys. Rev. Lett. 122, 232502 (2019). Further, we show that if an additional, near-degenerate parameter is introduced into the same OMP analysis such that the parameter posterior becomes non-Gaussian, then covariance-based estimates of uncertainty become unreliable. Finally, we show that regardless of optimization approach, if χ 2 /N is used for the likelihood, the resulting parametric uncertainties increase by $\sqrt{N}$, and that this is responsible for the conclusions drawn in the revisited study. Based on our replication results, we find that a fortuitous cancellation of unreported errors and the renormalization factor can lead to improvement in empirical coverages, as was the case in the original comparative study. We emphasize that developing and applying a realistic likelihood function is an essential task in a UQ analysis, and that several recent UQ studies that employed a renormalized likelihood (i.e., including a 1/N factor) may have yielded unrealistically large uncertainties for elastic-scattering observables. If the parameter posterior deviates from multivariate-normal, a sampling-based approach like MCMC has a clear advantage over methods that assume the Laplace approximation holds. We note that empirical coverage can serve as an important internal check for the analyst whose model or data may have additional, unaccounted-for uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Make the Fastest Faster: Importance Mask Synthesis for Interactive Volume Visualization using Reconstruction Neural Networks

Visualizing a large-scale volumetric dataset with high resolution is challenging due to the substantial computational time and space complexity. Recent deep learning-based image inpainting methods significantly improve rendering latency by reconstructing a high-resolution image for visualization in constant time on GPU from a partially rendered image where only a portion of pixels go through the expensive rendering pipeline. However, existing solutions need to render every pixel of either a predefined regular sampling pattern or an irregular sample pattern predicted from a low-resolution image rendering. Both methods require a significant amount of expensive pixel-level rendering. In this work, we provide Importance Mask Learning (IML) and Synthesis (IMS) networks, which are the first attempts to directly synthesize important regions of the regular sampling pattern from the user’s view parameters, to further minimize the number of pixels to render by jointly considering the dataset, user behavior, and the downstream reconstruction neural network. Our solution is a unified framework to handle various types of inpainting methods through the proposed differentiable compaction/decompaction layers. Experiments show our method can further improve the overall rendering latency of state-of-the-art volume visualization methods using reconstruction neural network for free when rendering scientific volumetric datasets. Our method can also directly optimize the off-the-shelf pre-trained reconstruction neural networks without elongated retraining.

Large-scale data↗

Novel Anti-LY6G6D/CD3 T-Cell–Dependent Bispecific Antibody for the Treatment of Colorectal Cancer

Abstract New therapeutics and combination regimens have led to marked clinical improvements for the treatment of a subset of colorectal cancer. Immune checkpoint inhibitors have shown clinical efficacy in patients with mismatch-repair–deficient or microsatellite instability–high (MSI-H) metastatic colorectal cancer (mCRC). However, patients with microsatellite-stable (MSS) or low levels of microsatellite instable (MSI-L) colorectal cancer have not benefited from these immune modulators, and the survival outcome remains poor for the majority of patients diagnosed with mCRC. In this article, we describe the discovery of a novel T-cell–dependent bispecific antibody (TDB) targeting tumor-associated antigen LY6G6D, LY6G6D-TDB, for the treatment of colorectal cancer. RNAseq analysis showed that LY6G6D was differentially expressed in colorectal cancer with high prevalence in MSS and MSI-L subsets, whereas LY6G6D expression in normal tissues was limited. IHC confirmed the elevated expression of LY6G6D in primary and metastatic colorectal tumors, whereas minimal or no expression was observed in most normal tissue samples. The optimized LY6G6D-TDB, which targets a membrane-proximal epitope of LY6G6D and binds to CD3 with high affinity, exhibits potent antitumor activity both in vitro and in vivo. In vitro functional assays show that LY6G6D-TDB–mediated T-cell activation and cytotoxicity are conditional and target dependent. In mouse xenograft tumor models, LY6G6D-TDB demonstrates antitumor efficacy as a single agent against established colorectal tumors, and enhanced efficacy can be achieved when LY6G6D-TDB is combined with PD-1 blockade. Our studies provide evidence for the therapeutic potential of LY6G6D-TDB as an effective treatment option for patients with colorectal cancer.

60 APPLIED LIFE SCIENCES↗

Electroless Plated Nanodiamond Coating for Stainless Steel Passivation

Tritium gas sample bottles and manifold components require passivation surface treatments to minimize the interaction of the hydrogen isotopes with surface contamination on the stainless steel containment materials. This document summarizes the effort to evaluate electroless plated nanodiamond coatings as a passivation layer for stainless steel. In this work, we developed an electroless nanodiamond (ND)-copper (Cu) coating process to deposit ND on stainless steel parts with the diamond loadings of 0%, 25% and 50% v/v in a Cu matrix. The coated Conflat Flanged Vessel Assemblies (CFVAs) were evaluated on surface morphology, composition, ND distribution, residual hydrogen release, and surface reactivity with deuterium. For as-received Cu and ND-Cu coated CFVAs, hydrogen off-gassing is rapid, and the off-gas rates of H 2 was one to two orders of magnitude higher than that for both untreated and electropolished stainless steel CFVAs, and hydrogen and deuterium reacted to form HD as well. These results indicated that residual H 2 was entrapped in the Cu and ND-Cu coated CFVAs during the coating process, and moisture was adsorbed on the surface, and ND and/or Cu might facilitate catalytic isotope exchange reaction for HD formation. However, hydrocarbons (i.e., CH 3 ) did not form, and did not appear to be an issue for the Cu and ND-Cu coated CFVAs. After vacuum heating, residual H 2 and adsorbed H 2 O in the Cu and ND-Cu coated CFVAs were dramatically reduced. The H 2 off-gassing rate after the vacuum treatment of Cu and 50% ND-Cu coated CFVAs was on the level of 10 -14 l mbar/s cm 2 , while H 2 O off-gas rate was on the level of 10 -15 l mbar/s cm 2 , consistent with the untreated or electropolished stainless steel CFVA, but the HD formation remained. The Restek EP bottle was used as a reference for this work. The Restek Electro-Polished (EP) bottle and their SilTek coated bottles tested under a different research project exhibited very little hydrogen off-gassing and unmeasurable HD formation. ND and Cu were initially chosen to develop improved passivation technology, because Cu has a lower permeability of hydrogen, and diamond is more inert than other materials under a hydrogen atmosphere. However, our tests demonstrated that even after an 8-18 day vacuum extraction heat treatment, the electroless plated Cu and ND-Cu coated stainless steel CFVAs exhibited H 2 off-gassing rates that were just comparable to those for the untreated or electropolished stainless steel CFVA, and the HD formation was still observed. Thus, the Restek Electro-Polished (EP) bottle outperformed the electroless plated Cu and ND-Cu coated stainless steel CFVAs, and the electroless plated nanodiamond coating is not promising as a surface passivation technology. However, the ND-Cu coating may be beneficial to another application in which catalyzing the H 2 -D 2 exchange reaction is desired.

08 HYDROGEN↗

Understanding Photon / Free Carrier Interaction in LVP Signals on Ultra-Thin Silicon ICs.

This project investigated a recently patented Sandia technology known as visible light Laser Voltage Probing (LVP). In this effort we carefully prepared well understood and characterized samples for testing. These samples were then operated across a range of configurations to minimize the possibility of superposition of multiple photon carrier interactions as data was taken with conventional and visible light LVP systems. Data consisted of LVP waveforms and Laser Voltage Images (LVI). Visible light (633 nm) LVP data was compared against 1319 nm and 1064 nm conventional LVP data to better understand the similarities and differences in mechanisms for all wavelengths of light investigated. The full text can be obtained by reaching the project manager, Ed Cole or the Cyber IA lead, Justin Ford.

36 MATERIALS SCIENCE↗

CSTT Update: Fuel Quality Analyzer

Presentation summary: A Nafion® based, electrochemical hydrogen contaminant detector was tested at H2Frontier hydrogen filling station in Burbank CA during its refit and recommissioning.; A 100 sccm sample was taken from the H2F production skid and without requiring humidification; both real-time product gas and storage gas was sampled. The selfhumidifying approach using an internal reservoir worked with minimal baseline drift.; The LANL HCD easily detected CO byproduct during reformer restart (as high as 18ppm) and 11, 1ppm challenges were performed during an 850h experiment after initial installation and 10ppm testing/commissioning.; The 10ppm and 1ppm challenges produced ≈ 75% and ≈ 60% reductions in pumping current respectively. Twelve, 1ppm challenges decreased pumping current on average of 59.5% with an error of ±1.4% over 12 challenges during a 6 month time period.; Long term baseline data show a drift rate of 9x10- 7 A/h over a 600h period of testing. The addition of a 1.5V, 600s pulse approximately once a day eliminated any long term drift.; No false positives or false negatives were seen during the field tests to date.; Average water consumption rate is estimated to be ~250μl/day at 100sccm.; Project milestones successfully met.

08 HYDROGEN↗

Improved Joint FHC+RHC Sterile Analysis with Nu-on-E Sample

The NOvA experiment measures neutrino oscillations in a nearly pure muon neutrino beam. The neutral current (NC) and the muon neutrino charged current (CC) interaction disappearance are studied to search for active-to-sterile neutrino oscillations. NOvA consists of two functionally identical detectors placed 14 mrad off-axis of Fermilab's NuMI beamline. The Near Detector (ND) is located 100 m underground on-site at Fermilab, while the Far Detector (FD) sits on the surface 810 km away at Ash River, Minnesota. The NuMI beam is capable of running in forward or reverse horn current modes, creating a predominantly neutrino or antineutrino beam, respectively. For this analysis, a simultaneous near and far detector joint fit approach was utilized. Systematic uncertainties constrain the ND while the statistical uncertainties constrain the FD. For the upcoming analysis, we plan on including a dedicated neutrino-on-electron elastic scattering sample. This interaction is advantageous as it is subject to minimal cross-section uncertainties, which will help reduce degeneracies between other uncertainty categories. This thesis presents the sterile neutrino oscillation sensitivity results using 27.2e+20 POT in FHC mode, 12.6e+20 in RHC mode.

Haejun, Stella Oh [Cincinnati U.]↗

An Integrated Framework for Memory-Centric Analysis: From Trace Collection to Co-Design

The memory wall phenomenon—where advances in processor performance significantly outpace those in memory subsystems—poses a fundamental challenge for contemporary computing systems. In memory-bound applications, memory subsystem behavior dominates performance, yet existing analysis approaches present significant limitations: detailed microarchitectural simulators require days to weeks to simulate modest workloads; hardware performance counters provide only aggregate statistics that obscure temporal and spatial access patterns; and scaled simulation approaches face challenges in capturing certain behaviors that emerge at larger scales. These limitations reflect a processor-centric design philosophy increasingly misaligned with memory-bound workloads where detailed understanding of memory access patterns, cache hierarchy interactions, and contention is critical for effective optimization. This paper presents an integrated framework for memory-centric analysis that enables effective hardware-software co-design. We describe practical trace collection techniques, including hardware-assisted processor tracing with minimal overhead and portable software-based instrumentation with statistical sampling. We present multi-perspective analysis methods that examine memory behavior from temporal, sequential, spatial, and relational viewpoints, revealing distinct optimization opportunities invisible in aggregate metrics. We detail an architectural modeling framework that uses sampled traces with temporal interpolation and confidence-based filtering to evaluate cache and memory configurations. Evaluation on representative benchmarks demonstrates that this framework achieves practical accuracy (L2 cache errors of 2.64\%, confidence-filtered L3 errors of 9.92\%, bandwidth errors of 7.33\%) while providing substantial speedup (26.8×) over cycle-accurate simulation, enabling rapid design space exploration. We demonstrate how this integrated framework enables systematic identification of both hardware optimizations (memory controller tuning, bank partitioning, NUMA configuration) and software optimizations (data layout restructuring, prefetching strategies, memory-aware scheduling). Through this comprehensive treatment of the memory-centric analysis pipeline—from trace collection through architectural modeling to co-design application—we provide researchers and practitioners with practical techniques for addressing memory bottlenecks in contemporary computing systems.

Gajaria, Dhruv Mayur↗

Thermoluminescence: Potential Applications in Forensic Science

In crime laboratories one of the most difficult operations is to determine unequivocally whether or not two samples of evidence of the same type were originally part of the same thing or were from the same source. It has been found that high temperature thermoluminescence (room temperature to 723 K) can be used for comparisons of this type, although work to date indicates that there is generally a finite probability for coincidental matching of glass or soil samples. Further work is required to determine and attempt to minimize these probabilities for different types of materials, and to define more clearly the scope of applicability of thermoluminescence to actual forensic situations.

Ingham, J. D.↗

An evaluation of the use of ERTS-1 satellite imagery for grizzly bear habitat analysis

Multispectral scanner images taken by the ERTS-1 satellite in August and October, 1972, were examined to determine if they would be useful in identifying and mapping favorable habitat for grizzly bears. It was possible to identify areas having a suitable mixture of alpine meadow and timber, and to eliminate those which did not meet the isolation requirements of grizzlies because of farming or grazing activity. High altitude timbered areas mapped from satellite imagery agreed reasonably well with the distribution of whitebark pine, an important food species. Analysis of satellite imagery appears to be a valuable supplement to present ground observation methods, since it allows the most important areas to be identified for intensive study and many others to be eliminated from consideration. A sampling plan can be developed from such data which will minimize field effort and overall program cost.

Varney, J. R.↗