Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualizing Overall Water Splitting on Single Microcrystals of Phosphorus-Doped BiVO 4 by Photo-SECM

Particulate bismuth vanadate (BiVO4) has attracted considerable interest as a promising photo(electro)catalyst for visible-light-driven water oxidation, however, overall water splitting (OWS) has been difficult to attain because its conduction band is too positive for efficient hydrogen evolution. Using photo-scanning electrochemical microscopy (photo-SECM) with a chemically modified nanotip, we visualized for the first time the OWS at a single truncated bipyramidal microcrystal of phosphorus-doped BiVO 4 . The tip simultaneously served as a light guide to illuminate the photocatalyst and as an electrochemical nanoprobe to observe and quantitatively measure local oxygen and hydrogen fluxes. The obtained current patterns for both O 2 and H 2 agree well with the accumulation of photogenerated holes and electrons on {010} basal and {110} lateral facets, respectively. Furthermore, the developed experimental approach is an important step towards nanoelectrochemical mapping of the activity of photocatalyst particles at the sub-facet level.

bismuth vanadate↗

Electromechanical response of amorphous LaAlO{sub 3} thin film probed by scanning probe microscopies

The electromechanical response of a 3 nm thick amorphous LaAlO{sub 3} layer obtained by molecular beam epitaxy has been studied using scanning probe microscopies. Although this kind of sample is not ferroelectric due to its amorphous nature, the resulting images are identical to what is generally obtained on truly ferroelectric samples probed by piezoresponse force microscopy: domains of apparently opposite polarisation are detected, and perfect, square shaped hysteresis loops are recorded. Moreover, written patterns are stable within 72 h. We discuss in the general case the possible origins of this behaviour in terms of charge injection, ionic conduction and motion of oxygen vacancies. In the case presented in this paper, since the writing process has been conducted with applied voltages lower than the injection threshold measured by conductive atomic force Microscopy, allowing to withdraw the hypothesis of charge injection in the sample, we propose that a bistable distribution of oxygen vacancies is responsible for this contrast.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local p‐ and n‐Type Doping of an Oxide Semiconductor via Electric‐Field‐Driven Defect Migration

Layered oxides exhibit high ionic mobility and chemical flexibility, attracting interest as cathode materials for lithium-ion batteries and the pairing of hydrogen production and carbon capture. Recently, layered oxides emerged as highly tunable semiconductors. For example, by introducing anti-Frenkel defects, the electronic hopping conductance in hexagonal manganites is increased locally by orders of magnitude. Here, local acceptor and donor doping in Er(Mn,Ti)O3 is demonstrated, facilitated by the controlled splitting of anti-Frenkel defects under applied d.c. voltage. By combining density functional theory calculations, scanning probe microscopy, atom probe tomography, and scanning transmission electron microscopy, it is shown that the oxygen defects can readily be moved through the layered crystal structure, leading to nano-sized interstitial-rich (p-type) and vacancy-rich (n-type) regions. The resulting pattern is comparable to dipolar npn-junctions and stable on the timescale of days. These findings reveal the possibility of temporarily functionalizing oxide semiconductors at the nanoscale, giving additional opportunities for the field of oxide electronics and the development of transient electronics in general.

He, Jiali↗

Epitaxial growth and characterization of magnesium gallate (MgGa 2 O 4 ) thin films by pulsed laser deposition

To advance high power device application of MgGa 2 O 4 , it is imperative to achieve crystalline epitaxial thin films and to observe its materials’ characteristics within a wide range of growth conditions. However, there is no published work on the growth of this promising ultrawide bandgap material till this day. In this study, we report the crystalline growth of MgGa 2 O 4 thin films on c-plane (006) sapphire substrates using the pulsed laser deposition (PLD) technique in a broad range of temperature and oxygen pressure. The temperature range for this crystalline growth was within the temperature range of 300°C to 700°C and a pressure range of 1x10 -1 to 1x10 -3 Torr. Within this parameter range, the structural, chemical, optical, and surface property of MgGa 2 O 4 thin films have been investigated. Specifically, the acquired XRD patterns confirmed the film growth along the [111] preferential crystal orientation in the lattice. Here, the rocking curve measurement of the prominent (222) plane showed an increasing trend of the crystallinity with growth temperature and pressure. Furthermore, the XRD phi (φ) scan demonstrated the six-fold rotational symmetry of the MgGa 2 O 4 films and the epitaxial relationship of 30° between the film and the sapphire substrate. The XPS spectra confirmed the presence of +2 and +3 oxidation state for Mg and Ga respectively, in the films. The direct bandgap of MgGa 2 O 4 films was obtained ~5.27±0.03 eV by analyzing the UV-Vis absorbance spectra using the Tauc equation. The SEM images exhibited a granular surface morphology of the MgGa 2 O 4 films with an increasing trend in the grain size from low to high temperature and pressure. The refractive index and thickness of these films were in the range of ~1.90±0.02 and ~70±2.0 nm, respectively determined by fitting the spectroscopic ellipsometry data.

36 MATERIALS SCIENCE↗

Characterization of a wollastonite glass-ceramic material prepared using sugar cane bagasse ash (SCBA) as one of the raw materials

Glass-ceramic material prepared with sugar cane bagasse ash as one of the raw materials was characterized to determine some important properties for its application as a coating material. X-ray diffraction patterns showed that wollastonite-2M (CaSiO{sub 3}) was the major glass-ceramic phase. The Rietveld method was used to quantify the crystalline (60 wt.%) and vitreous (40 wt.%) phases in the glass-ceramic. The microstructure (determined by scanning electron microscopy) of this material had a marble appearance, showing a microporous network of elongated crystals with some areas with dendritic, feather-like ordering. Microhardness data gave a mean hardness value of 564.4 HV (Vickers-hardness), and light microscopy disclosed a greenish brown colored material with a vitreous luster. - Highlights: • We studied the properties of a glass-ceramic material obtained from sugarcane ash. • This material has the appearance and hardness of natural stones. • A refining method gave information about its amorphous and crystalline phases. • This material has potential to be used as coating plates for buildings.

36 MATERIALS SCIENCE↗

Microstructural, optical and electrical investigations of Sb-SnO{sub 2} thin films deposited by spray pyrolysis

Highlights: • We controlled structural, morphological, electrical, optical and physical (such as band gap energy) properties by altering the Sb doping concentration. • Variation in bandgap with Sb concentration is in agreement with the Burstein–Moss hypothesis and this hypothesis was further confirmed by plotting E{sub g} vs n{sup 2/3}. • The resistivity and mobility are in the range of 1.512–6.624 × 10{sup −3} Ω cm and 9.75–22.96 cm{sup 2} V{sup −1} s{sup −1}. The e-density lies between 4.11 × 10{sup 19} and 4.24 × 10{sup 20} cm{sup −3}. • We observed that Sb substitution in SnO{sub 2} lattice decreases the crystallite size and the possible reason for this is the creation of Sb monolayer on the surface of SnO{sub 2} crystallite. - Abstract: The structural, optical and electrical properties of spray deposited antimony (Sb) doped tin oxide (SnO{sub 2}) thin films, prepared from SnCl{sub 4} precursor, have been studied as a function of antimony doping concentration. The doping concentration was varied from 0 to 1.5 wt.% of Sb. The analysis of X-ray diffraction patterns revealed that the as deposited doped and undoped tin oxide thin films are pure crystalline tetragonal rutile phase of tin oxide which belongs to the space group P4{sub 2}/mnm (number 136). The surface morphological examination with field emission scanning electron microscopy (FESEM) revealed the fact that the grains are closely packed and pores/voids between the grains are very few. The resistivity (ρ) and mobility (μ) are in the range of 1.512 × 10{sup −3}–6.624 × 10{sup −3} Ω cm and 9.75–22.96 cm{sup 2} V{sup −1} s{sup −1}. The electron density lies between 4.11 × 10{sup 19} and 4.24 × 10{sup 20} cm{sup −3}. A thorough electrical investigation reveals that the film's resistivity depends on carrier concentration. It is found that ionized impurity scattering is the dominant mechanism, which limits the mobility of the carriers. The transmittance spectra for as-deposited films were recorded in the wavelength range of 200–1000 nm. The transmittance of the films was observed to increase from 57% to 68% (at 800 nm) on initial addition of Sb (up to [Sb]/[Sn] = 0.5 wt.%) and then it is decreased for higher level of antimony doping ([Sb]/[Sn] >0.5 wt.%)

36 MATERIALS SCIENCE↗

Imaging the p-n junction in a gallium nitride nanowire with a scanning microwave microscope

We used a broadband, atomic-force-microscope-based, scanning microwave microscope (SMM) to probe the axial dependence of the charge depletion in a p-n junction within a gallium nitride nanowire (NW). SMM enables the visualization of the p-n junction location without the need to make patterned electrical contacts to the NW. Spatially resolved measurements of S{sub 11}{sup ′}, which is the derivative of the RF reflection coefficient S{sub 11} with respect to voltage, varied strongly when probing axially along the NW and across the p-n junction. The axial variation in S{sub 11}{sup ′} effectively mapped the asymmetric depletion arising from the doping concentrations on either side of the junction. Furthermore, variation of the probe tip voltage altered the apparent extent of features associated with the p-n junction in S{sub 11}{sup ′} images.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Note: An X-ray powder diffractometer with a wide scattering-angle range of 72° using asymmetrically positioned one-dimensional detectors

An X-ray powder diffractometer has been developed for a time-resolved measurement without the requirement of a scattering angle (2θ) scan. Six one-dimensional detector modules are asymmetrically arranged in a vertical line at a designed distance of 286.5 mm. A detector module actually covers a diffraction angle of about 12° with an angular resolution of 0.01°. A diffracted intensity pattern is simultaneously recorded in a 2θ angular range from 1.63° to 74.37° in a “one shot” measurement. We tested the performance of the diffractometer with reference CeO{sub 2} powders and demonstrated diffraction measurements from an operating lithium-air battery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Ghost Imaging

Here in this paper, we report a demonstration of electron ghost imaging. A digital micromirror device directly modulates the photocathode drive laser to control the transverse distribution of a relativistic electron beam incident on a sample. Correlating the structured illumination pattern to the total sample transmission then retrieves the target image, avoiding the need for a pixelated detector. In our example, we use a compressed sensing framework to improve the reconstruction quality and reduce the number of shots compared to raster scanning a small beam across the target. Finally, compressed electron ghost imaging can reduce both acquisition time and sample damage in experiments for which spatially resolved detectors are unavailable (e.g., spectroscopy) or in which the experimental architecture precludes full frame direct imaging.

43 PARTICLE ACCELERATORS↗

Characterization of sub-micrometre-sized voids in fixed human brain tissue using scanning X-ray microdiffraction

Using a 5 µm-diameter X-ray beam, we collected scanning X-ray microdiffraction in both the small-angle (SAXS) and the wide-angle (WAXS) regimes from thin sections of fixed human brain tissue from Alzheimer's subjects. The intensity of scattering in the SAXS regime of these patterns exhibits essentially no correlation with the observed intensity in the WAXS regime, indicating that the structures responsible for these two portions of the diffraction patterns, which reflect different length scales, are distinct. SAXS scattering exhibits a power-law behavior in which the log of intensity decreases linearly with the log of the scattering angle. The slope of the log–log curve is roughly proportional to the intensity in the SAXS regime and, surprisingly, inversely proportional to the intensity in the WAXS regime. We interpret these observations as being due to the presence of sub-micrometre-sized voids formed during dehydration of the fixed tissue. The SAXS intensity is due largely to scattering from these voids, while the WAXS intensity derives from the secondary structures of macromolecular material surrounding the voids. The ability to detect and map the presence of voids within thin sections of fixed tissue has the potential to provide novel information on the degradation of human brain tissue in neurodegenerative diseases.

Chemistry↗

Plate-specific gain map correction for the improvement of detective quantum efficiency in computed radiography

Purpose: The purpose of this work is to improve the noise power spectrum (NPS), and thus the detective quantum efficiency (DQE), of computed radiography (CR) images by correcting for spatial gain variations specific to individual imaging plates. CR devices have not traditionally employed gain-map corrections, unlike the case with flat-panel detectors, because of the multiplicity of plates used with each reader. The lack of gain-map correction has limited the DQE(f) at higher exposures with CR. This current work describes a feasible solution to generating plate-specific gain maps. Methods: Ten high-exposure open field images were taken with an RQA5 spectrum, using a sixth generation CR plate suspended in air without a cassette. Image values were converted to exposure, the plates registered using fiducial dots on the plate, the ten images averaged, and then high-pass filtered to remove low frequency contributions from field inhomogeneity. A gain-map was then produced by converting all pixel values in the average into fractions with mean of one. The resultant gain-map of the plate was used to normalize subsequent single images to correct for spatial gain fluctuation. To validate performance, the normalized NPS (NNPS) for all images was calculated both with and without the gain-map correction. Variations in the quality of correction due to exposure levels, beam voltage/spectrum, CR reader used, and registration were investigated. Results: The NNPS with plate-specific gain-map correction showed improvement over the noncorrected case over the range of frequencies from 0.15 to 2.5 mm{sup -1}. At high exposure (40 mR), NNPS was 50%-90% better with gain-map correction than without. A small further improvement in NNPS was seen from carefully registering the gain-map with subsequent images using small fiducial dots, because of slight misregistration during scanning. Further improvement was seen in the NNPS from scaling the gain map about the mean to account for different beam spectra. Conclusions: This study demonstrates that a simple gain-map can be used to correct for the fixed-pattern noise in a given plate and thus improve the DQE of CR imaging. Such a method could easily be implemented by manufacturers because each plate has a unique bar code and the gain-map for all plates associated with a reader could be stored for future retrieval. These experiments indicated that an improvement in NPS (and hence, DQE) is possible, depending on exposure level, over a wide range of frequencies with this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-401: Feasibility Study of Using ABC to Gate Lung SBRT Treatment

Purpose: The current SBRT treatment techniques include free breathing (FB) SBRT and gated FB SBRT. Gated FB SBRT has smaller target and less lung toxicity with longer treatment time. The recent development of direct connectivity between the ABC and linac allowing for automated beam gating. In this study, we have examined the feasibility of using ABC system to gate the lung SBRT treatment. Methods: A CIRS lung phantom with a 3cm sphere-insert and a moving chest plate was used in this study. Sinusoidal motion was used for the FB pattern. An ABC signal was imported to simulate breath holds. 4D-CT was taken in FB mode and average-intensity-projection (AIP) was used to create FB and 50% gated FB SBRT planning CT. A manually gated 3D CT scan was acquired for ABC gated SBRT planning.An SBRT plan was created for each treatment option. A surface-mapping system was used for 50% gating and ABC system was used for ABC gating. A manually gated CBCT scan was also performed to verify setup. Results: Among three options, the ABC gated plan has the smallest PTV of 35.94cc, which is 35% smaller comparing to that of the FB plan. Consequently, the V20 of the left lung reduced by 15% and 23% comparing to the 50% gated FB and FB plans, respectively. The FB plan took 4.7 minutes to deliver, while the 50% gated FB plan took 18.5 minutes. The ABC gated plan delivery took only 10.6 minutes. A stationary target with 3cm diameter was also obtained from the manually gated CBCT scan. Conclusion: A strategy for ABC gated lung SBRT was developed. ABC gating can significantly reduce the lung toxicity while maintaining the target coverage. Comparing to the 50% gated FB SBRT, ABC gated treatment can also provide less lung toxicity as well as improved delivery efficiency. This research is funded by Elekta.

60 APPLIED LIFE SCIENCES↗

High Energy Neutrino Physics with NOvA

Knowledge of the position of energy deposition in “hit” detector cells of the NOvA neutrino detector is required by algorithms for pattern reconstruction and particle identification necessary to interpret the raw data. To increase the accuracy of this process, the majority of NOvA's 350 000 far detector cell shapes, including distortions, were measured as they were constructed. Using a special laser scanning system installed at the site of the NOvA far detector in Ash River, MN, we completed algorithmic development and measured shape parameters for the far detector. The algorithm and the measurements are “published” in NOνA’s document database (doc #10389, “Cell Center Finder for the NOνA Far Detector Modules”).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherence in Polycrystalline Thin Films of Twisted Molecular Crystals

Helicoidal crystallites in rhythmically banded spherulites manifest spectacular optical patterns in small molecules and polymers. It is shown that concentric optical bands indicating crystallographic orientations typically lose coherence (in-phase twisting) with growth from the center of nucleation. Here, coherence is shown to increase as the twist period decreases for seven molecular crystals grown from the melt. This dependence was correlated to crystallite fiber thickness and length, as well as crystallite branching frequency, a parameter that was extracted from scanning electron micrographs, and supported by numerical simulations. Hole mobilities for 2,5-didodecyl-3,6-di(thiophen-2-yl)pyrrolo[3,4-c]pyrrole-1,4(2H,5H)-dione (DPP-C12) measured by using organic field-effect transistors demonstrated that more incoherent boundaries between optical bands in spherulites lead to higher charge transport for films with the same twist period. This was rationalized by combining our growth model with electrodynamic simulations. This work illustrates the emergence of complexity in crystallization processes (spherulite formation) that arises in the extra variable of helicoidal radial twisting. The details of the patterns analyzed here link the added complexity in crystal growth to the electronic and optical properties of the thin films.

36 MATERIALS SCIENCE↗

Performance of Composite Insulators Used for Electric Transmission under Extreme Climatic Conditions

Composite or polymeric insulators are being used in various parts of the world for high-voltage transmission and distribution lines. In some parts of India, places in the states like Rajasthan and Gujarat experience an increase in the daytime temperature up to 50 °C, while the nighttime temperature reduces as low as 3-5 °C. Because of these extreme temperature variations along with electric stress and humidity conditions, composite insulators have to perform well over their lifetime to ensure the reliability of the transmission network. In the present work, experimental conditions are simulated with temperature variation from 50 to 3-5 °C along with electrical stress, humidity variation, pollution, and ultraviolet radiations. Accelerated aging studies with these stresses are conducted to understand the degradation on the insulator similar to the field conditions. Surface resistivity measurements, leakage current analysis, and surface degradation studies using thermogravimetric analysis, scanning electron microscopy, energy-dispersive x-ray, and Fourier transform infrared spectroscopy (FTIR) are conducted. Some interesting results obtained from the study are presented. Experimentation under extreme conditions with polluted insulators showed considerable degradation which was inferred from the material testing analysis. The insulator slabs on which electrical stress was not applied showed a considerable peak at 1500 cm{sup −1} in the FTIR spectra, indicating the generation of low molecular weight PDMS chains from the bulk due to UV aging and thermal stress, while the degradation pattern of non-polluted sample was severe compared to the slab treated but was considerably less severe in comparison with the polluted insulator sample exhibiting pollution can considerably increase degradation rate.

36 MATERIALS SCIENCE↗

Operando synchrotron X-ray analysis of melt pool dynamics in an Al-Sn immiscible alloy

The melt flow in an Al-50vol.% Sn immiscible alloy, produced by single-track laser melting of Al and Sn elemental powders, was studied in real time. High-speed synchrotron X-ray imaging was used to track Al and Sn liquids’ movements, and also to examine elemental distributions in the laser tracks, complimented by electron microscopy after solidification. Key aspects, including melt pool geometry, keyhole instability, and flow dynamics (flow pattern and velocity), were examined using digital image analysis. Relatively deeper melt pools formed at 400 W and 300 mm/s exhibited greater stability, with smooth surfaces, consistent outward flow, and minor vortices near the keyhole. In contrast, shallower pools produced at higher scanning speeds (>500 mm/s) demonstrated greater instability with increased surface waviness, and stronger velocity fluctuations, leading to numerous micro-vortices and increased Al-Sn heterogeneity. Velocity scale estimations, supported by experimental observations, examined the roles of vapour pressure, Marangoni effect, buoyancy, inertial, and surface tension forces in the flow. The results revealed that vapour pressure and mechanical waves dominated at high scanning speeds (shallow pools), while Marangoni forces were equally significant in deep pools at lower speeds (300 mm/s). Buoyancy was found to have minimal impact in both cases. Furthermore, the interaction between inertial and surface tension forces played a critical role in determining the degree of waviness of the pools’ surfaces. These findings offer valuable insights into melt pool dynamics during laser processing of immiscible alloys and other metallic systems using elemental powders, and provide guidance for developing high-fidelity computational fluid dynamics models.

immiscible alloys↗

Isotoxic Dose Escalation in the Treatment of Lung Cancer by Means of Heterogeneous Dose Distributions in the Presence of Respiratory Motion

Purpose: To test, in the presence of intrafractional respiration movement, a margin recipe valid for a homogeneous and conformal dose distribution and to test whether the use of smaller margins combined with heterogeneous dose distributions allows an isotoxic dose escalation when respiratory motion is considered. Methods and Materials: Twenty-three Stage II-III non-small-cell lung cancer patients underwent four-dimensional computed tomography scanning. The gross tumor volume and clinical target volume (CTV) were outlined in the mid-ventilation phase. The CTV-to-planning target volume (PTV) margin was calculated by use of a standard margin recipe and the patient-specific respiration pattern. Standard three-dimensional treatment plans were generated and recalculated on the remaining respiration phases. The planning was repeated for a CTV-to-PTV margin decreased by 2.5 and 5 mm relative to the initial margin in all directions. Time-averaged dose-volume histograms (four-dimensional dose-volume histograms) were calculated to evaluate the CTV-to-PTV margin. Finally, the dose was escalated in the plans with decreased PTV such that the mean lung dose (predictor of radiation-induced pneumonitis) was equal to mean lung dose in the plan by use of the initially calculated margin. Results: A reduction of the standard margin by 2.5 mm compared with the recipe resulted in too low of a minimum dose for some patients. A combination of dose escalation and use of heterogeneous dose distribution was able to increase the minimum dose to the target by approximately 10% and 20% for a CTV-to-PTV margin reduction of 2.5 mm and 5.0 mm, respectively. Conclusion: The margin recipe is valid for intrafractional respiration-induced tumor motions. It is possible to increase the dose to the target without increased mean lung dose with an inhomogeneous dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗